Records from 1985 to 1990. Most recent: inspection, 3 October 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
3 October 1990
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 930221
13 June 1990
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1223125
2 April 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1215187
20 December 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1220286
9 November 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1228913
27 October 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1229287
26 October 1989
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1228240
16 September 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1221120
18 August 1989
Drydock Extension · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1205854
3 May 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909817
28 April 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 896736
1 February 1989
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 888200
19 December 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1037274
4 November 1988
Re-Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1041353
10 June 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 889147
15 January 1988
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1336421
20 August 1987
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1023376
12 May 1987
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1029190
5 August 1986
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1015509
23 July 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1292333
23 July 1985
Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306684
Construction/Loadline
Issued 2 April 1990
Resolved
REMOVE RUBRAILS PORT/STBD TO MAKE ACCESS TO INSPECT UNDERLYING PLANKING TO DETERMINE CONDITION
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 April 1990
Resolved
RENEW/REPLACE DECK LONGITUDINAL (THAT IS ROTTEN TO A DEPTH OF TWO INCHES) IN WAY OF PORT HEAD MIDSHIPS
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 April 1990
Resolved
RENEW ROTTEN FRAME BENEATH MIDSHIPS ACCESS HATCH
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 April 1990
Resolved
RENEW SPLIT SEAMS BETWEEN PLANKS 4&5, PORT, AFT JUST FWD OF TRANSOM AND BETWEEN PLANS 3&4, STBDE, AFT OF MIDSHIPS
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 April 1990
Resolved
RENEW SPLIT PLANK (6 STRAKES DOWN FROM RUB RAIL, PORT MIDSHIPS)
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 2 April 1990
Resolved
RENEW BOW FRAMES 1-9, PORT/STBD HAVE ROTTEN ENDS IN WAY OF THE KEEL
Condition: Unknown
Due 15 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 9 November 1989
Resolved
REPLACE BILGE DISCHARGE HOSE FROM AFTER BILGE PUMP IN ENGINE ROOM WITH HOSE THAT IS OIL RESISTANT, NON-COLLAPSIBLE
Condition: Unknown
Due 31 January 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 26 October 1989
Resolved
RENEW WHITE POLYPROPYLENE GRAB LINES ON 12 PERSON BOUYANT APPARATUS CLEARED 27OCT89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Documentation
Issued 26 October 1989
Resolved
RENEW FCC SAFETY CERTIFICATE
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Documentation
Issued 26 October 1989
Resolved
SUBMIT CERTIFICATE OF DOCUMENTATION TO REFLECT CORRECT OWNERSHIP
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Fire Fighting
Issued 26 October 1989
Resolved
REMOVE OIL BASE PAINT/OTHER FLAMMABLE LIQUIDS FROM VESSEL CLEARED 8NOV89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Engineering
Issued 26 October 1989
Resolved
DOUBLE CLAMP ALL BILGE DISCHARGE HOSES AT HULL PENETRATION CLEARED 8NOV89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Engineering
Issued 26 October 1989
Resolved
LABEL LOCATION OF AFT FUEL SHUTOFF VALVE
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Lifesaving
Issued 26 October 1989
Resolved
PROVIDE THREE RED DISTRESS FLARES ON VESSEL
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Lifesaving
Issued 26 October 1989
Resolved
RELOCATE RING BOUY TO AN ACCESSIBLE LOCATION CLEARED 8NOV89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Lifesaving
Issued 26 October 1989
Resolved
PROVIDE 4 ADDITIONAL ADULT PFD'S CLEARED 9NOV89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Navigation
Issued 26 October 1989
Resolved
PROVIDE TIDE TABLES CLEARED 8NOV89
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Engineering
Issued 4 November 1988
Resolved
REMOVE ABSORBENT FUEL PILLOWS BENETH GENRATOR AND TWO MAIN ENGINES
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
RE-ATTACH GROUND WIRE TO STBD FUEL TANK
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Lifesaving
Issued 4 November 1988
Resolved
RENEW 9 COMBINATION DISTRESS FLARES
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
REMOVE LOOSE ELECTRICAL CABLE IN AFT ENGINE ROOM IN WAY OF PORT MAIN ENGINE. CABLE MAY BE LIVE
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
RENEW THREE FLEXIBLE FUEL LINES IN WAY OF GENERATOR FUEL FILTER
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
REPLACE LEAKING FUEL SHUT-OFF VALVE TO GENERATOR FILTER
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Lifesaving
Issued 4 November 1988
Resolved
RENEW ONE BUOYANT APPARATUS FOR 14 PERSONS. RE-ATTACH LIFE LINE TO EXIST- ING BUOYANT APPARATUS
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 4 November 1988
Resolved
PROPERLY WIRE FLOAT-ACTIVATED BILGE PUMP IN MACHINERY SPACE SO THAT LIGHT IS ENERGIZED WHEN FLOAT IS ACTIVATED
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
ELIMINATE WIRE NUTE ON PORT FORCED EXHAUST FAN AND WATER PUMP TO MASTER TOILET
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988
Resolved
ELIMINATE ROMEX - SOLID WIRE USED THROUGHOUT VESSEL. REPLACE WITH U.L. BOAT CABLE
Condition: Unknown
Due 30 September 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 November 1988
Resolved
WIRE ELECTRICAL CABLE FOR WATER SUPPLY PUMP AND 120 VOLT ELECTRICAL LINE INJUNCTION BOX
Condition: Unknown
Due 30 September 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 November 1988
Resolved
PERMANENTLY WIRE AIR CONDITIONER PUMP TO THERMOSTATE OR DIRECT WIRE TO JUNCTION BOX AND SWITCH
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988
Resolved
PROPERLY ATTACH BILGE DISCHARGE LINE ON STBD FORWARD ENGINE ROOM TO ELIMINATE LEAKAGE
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Navigation
Issued 4 November 1988
Resolved
PROVIDE PORT AND STBD RUNNING LIGHTS, MASTHEAD LIGHT AND ANCHOR LIGHT THAT COMPLY WITH 1972 COLREGS. FAIRING BLOCK SHALL BE PROVIDED FOR NAVIGATION LIGHTS LOCATED ON HULL SO THAT LIGHTS SHOW PROPER ARC. THIS REQUIREMENT ISSUED: 10JUN88
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988
Resolved
FREE SHUT OFF TO PORT FUEL TANK IN ENGINE ROOM
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988
Resolved
PROVIDE FOR REMOTE OPERATION OF PORT AND STBD FUEL TANKS FROM MAIN CABIN OROPERATOR STATION.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 10 June 1988
Resolved
ALL FLOAT ACTIVATED BILGE PUMPS SHALL HAVE INDICATOR LIGHTS AND MANUAL SWITCHES AT OPERATORS STATION
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
CONDUCT UNDERWAY EXAM
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Navigation
Issued 10 June 1988
Resolved
PROVIDE PORT & STBD RUNNING LIGHTS, MASTHEAD LIGHT AND ANCHOR LIGHT THAT COMPLY WITH 1972 COLREGS
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
RENEW PLANKS 6 & 7 PORT SIDE FOR APPROXIMATELY 5
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
RENEW PLANKS 12 & 13 ON STBD SIDE FOR APPROXIMATELY 5 FT AFT OF STEM
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Navigation
Issued 10 June 1988
Resolved
RENEW PORT AND STBD SHEER STRAKES AND RUB RAILS WHERE DAMAGED
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Lifesaving
Issued 10 June 1988
Resolved
PROVIDE PENANTS EVERY 18 INCHES ON INTERNAL CIRCUMFERANCE ON BOTH BUOYANT APPARATUS
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
DEMONSTRATE THAT INSTALLED BILGE HOSES ARE REINFORCED AND RESISTANT TO OIL
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 10 June 1988
Resolved
PROVIDE ACCESS TO FRAME NR3 ON STBD SIDE COUNTING AFT FROM STEM. REMOVE INTERIOR CEILING OR PANELLING FOR PROPER ACCESS TO FRAMES
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Construction/Loadline
Issued 20 August 1987
Resolved
MAKE PERMANENT REPAIRS TO FORWARD DECK AREA IN WAY OF FOREPEAK. ENSURE THAT EXISTING DECK AREA REMAIN WATER TIGHT UNTIL PERMANENT REPAIRS ARE COMPLETED.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Construction/Loadline
Issued 20 August 1987
Resolved
RENEW/REPAIR AS ORIGINAL ENTIRE STEM. MONITOR TEMPORARY REPAIRS TO STEM & NOTIFY THIS OFFICE OF ANY EXCESSIVE WORKING OF PLANKS, FRAMES OR STEM, ANY EXCESS LEAKAGE OR ANY CHANGE IN TEMPORARY REPAIR TO STEM WHICH WOULD AD- VERSELY AFFECT SEAWORTHINESS.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987
Construction/Loadline
Issued 20 August 1987
Resolved
REPAIR/RENEW AS ORIGINAL FIRST FRAME ON PORT SIDE AND SECOND FRAM ON STBD IN WAY OF FOREPEAK.
Condition: Unknown
Due 20 August 1987
Resolved 20 August 1987