MAURY USCG vessel records Sign in
← All vessels

ALASKAN GRANDE ISLE

ALASKAN GRANDE ISLE is a 1967 commercial fishing vessel. The Coast Guard has recorded 8 inspections since 1984, most recently in July 1986, along with 45 deficiencies.

Records from 1984 to 1986. Most recent: inspection, 8 July 1986.

Built
1967
Last inspected
8 July 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6806999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CYPRUS
—
Maury page id
psix-45567

Inspections, by type

…with no type recorded5
Years with a record 3 calendar years (1984–1986)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it2581 - Regulatory (Subpart C or D), Net Ton
4445 - Regulatory (Subpart C or D), Gross Ton
5839 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KKFEMMSI not assigned · expired · compulsorily equipped · granted 28 July 1989, cancelled 28 July 1994 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

8 July 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 999359
26 March 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1306138
21 March 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1303601
3 December 1985 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1302370
23 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984855
23 July 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1291798
16 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1285701
20 December 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977899

Deficiency record · 45

Unknown
Issued 3 December 1985 Resolved
[D10] PROVIDE A COPY OF THE FIXED FIRE FIGHTING FOAM CHEMICAL ANALYSIS TO [name withheld].
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Unknown
Issued 3 December 1985 Resolved
[D1] SERVICE ALL FIVE LIFERAFTS AND HYDROSTATIC RELEASES. FIVE YEAR INFLATION TEST HAS BEEN EXTEND TO JUNE 1986.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[D2] SERVICE FIXED CO2 SYSTEM INCLUDING TEST OF CABLE PULLS, TIME DELAY MECHANISM; SIRENS; VENTILATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[D9] PROVIDE TWO TOURNIQUETS FOR HOSPITAL/FIRST AID KIT.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E1] OPEN ALL PRESSURE VESSELS FOR INTERNAL EXAM OR HYDROSTATICALLY TEST AT1.25 X MAWP.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E2] TEST ALL PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[D4] WEIGH ALL CO2 CHARGES AND SPARES FOR PORTABLE DRY CHEMICAL EXTINGUISHERS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E11] POST THE PLACARD REQUIRED BY 33 CFR 155.450 "DISCHARGE OF OIL PROHIBITED" IN A CONSPICUOUS PLACE IN THE MACHINERY SPACE.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E12] TEST AIR PURGE ALARM ON DRILLERS CONSOLE.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E13] PROVIDE DOCUMENTATION OF ASME CODE CONSTRUCTION AND IDENTIFICATION AND/OR USCG APPROVAL FOR THE SIX DRY BULK TANKS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[D3] HYDROSTATICALLY TEST PORTABLE CO2 EXTINGUISHERS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E3] PROVIDE DOCUMENTATION OF ASME DESIGN & CONSTRUCTION OF THE FWD STBD WINCH STARTING AIR TANK. REPLACE THE EXISTING RELIEF VALVE WITH ONE RATED FOR OR BELOW MAWP. THIS TANK IS TO REMAIN DISCONNECTED UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E4] REPLACE INOPERATIVE RELIEF VALVES ON SANITARY TANK, POTABLE WATER TANKAND WASH WATER TANK.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E5] TEST OVERSPEED TRIPS ON ALL MAIN PROPULSION AND SHIPS SERVICE DIESEL GENERATORS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E6] REPAIR INOPERATIVE GENERAL ALARM BELLS #10, #25, #30 AND BELL IN CASING HOLD.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E7] REPLACE BURNED OUT "E" LIGHTS AS NECESSARY THROUGHOUT THE VESSEL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E8] RELABEL "E" LIGHTS WHERE THEY HAVE BEEN PAINTED OVER. (MOON POOL VOIDAND MUD PUMP ROOM)
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E9] LABEL EMERGENCY FUEL OIL SHUT OFF VALVE REACH RODS AT MAIN DECK, PORT AND STARBOARD.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985 Resolved
[E10] LABEL HELO FUELING PUMP EMERGENCY SHUT OFF ON STARBOARD SIDE OF THE HELO DECK.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985 Resolved
ALL MISSING GENERAL ALARM BELLS SHALL BE REPLACED WITH APPROVED BELLS UNLESS IT CAN BE SHOWN THAT THE GENERAL ALARM BELL LOCATIONS ARE IN ACCORDANCE WITH AN APPROVED PLAN.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985 Resolved
THE MISSING GENERAL ALARM BELL AFT OF THE RIG FLOOR SHALL BE REPLACED WITH ONE APPROVED FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985 Resolved
THE GENERAL ALARM BELL IN THE LAUNDRY ROOM ON THE MAIN DECK IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED BELL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985 Resolved
THE GENERAL ALARM BELL ON THE STARBOARD SIDE OF THE GENERATOR IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED BELL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985 Resolved
THE GENERAL ALARM BELL ON THE 'TWEEN DECK FORWARD OF THE MOON POOL IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED TYPE SUITABLE FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 16 January 1985 Resolved
CONDUCT THE 5 YEAR INFLATION TEST FOR THE LIFERAFT AT STATION 5 AT A COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 16 January 1985
Resolved 16 January 1985
Unknown
Issued 20 December 1984 Resolved
REPAIR OR RENEW LEAKING PIPES OVER ELECTRIC MOTOR FOR NO. 2 DESALINATOR.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE TWO ORANGE SMOKE FLOATING DISTRESS SIGNALS FOR THE LIFEBOATS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE USCG APPROVED EMBARKATION LADDERS FOR THE THE TWO FORWARD LIFERAFTS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
REPLACE MISSING HANDRAIL IN WAY OF CO2 FIXED EXTINGUISHING SYSTEM.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE A SECOND ESCAPE FOR WASHROOM AND RECREATION ROOMS ON THE BOW.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
COMPLETE TEMPORARY REPAIRS FOR ISOLATION OF DECK DRAINS IN THE FORWARD WINDLASS SPACE AND A/C ROOM FROM BERTHING AREAS BELOW. SEAL ALL PIPES LEADING TO AND FROM ROSEBOXES IN THE FORWARD BERTING SPACES PORT AND STBD. COMPLETE PERMANENT REPAIRS PRIOR TO NEXT DRYDOCK EXAM.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 December 1984 Resolved
RENEW HELO-DECK PERIPHERAL NETTING AND NETTING FRAME HINGES WHERE WASTED.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
ISOLATE THE 1JV SOUND POWERED TELEPHONE CIRCUIT FROM THE 3JV CIRCUIT AS ORIGINAL. THE STEERING GEAR SPACE MUST BE ON THE 1JV CIRCUIT.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
RENEW AS ORIGINAL THE PATCHED AND LEAKING FIREMAIN PIPING IN THE MUD PUMP ROOM.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 December 1984 Resolved
PROVIDE SIMPLE INSTRUCTIONS INCLUDING SCHEMATIC DIAGRAMS FOR THE FIXED EXTINGUISHING SYSTEM.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE AN AUDIBLE ALARM FOR THE EMERGENCY GENERATOR ENGINE LOW OIL PRESSURE AND HIGH COOLING WATER TEMPERATURE.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE ON BOARD A MINIMUM OF EIGHT USCG APPROVED (UL LISTED MARINE TYPE) PORTABLE FIRE EXTINGUISHERS WITH AII CLASSIFICATION FOR THE ACCOMODATION SPACES.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
WEIGH ALL FIXED AND SEMI-PORTABLE CO2 CYLINDERS. PROVIDE A COPY OF THE SERVICING REPORT SHOWING NET WEIGHTS TO [name withheld].
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE ONE MESA OR MSHA APPROVED FIRST AID KIT ON BOARD.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
RENEW OR REPAIR WASTED AND UNCOVERED BATTERY BOXES.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984 Resolved
PROVIDE RELIEF VALVES WITH HAND LIFTING DEVICES FOR THE THREE INSTALLED AIRDRYER PRESSURE VESSELS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.