Records from 1984 to 1986. Most recent: inspection, 8 July 1986.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 3 December 1985
Resolved
[D10] PROVIDE A COPY OF THE FIXED FIRE FIGHTING FOAM CHEMICAL ANALYSIS TO [name withheld].
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Unknown
Issued 3 December 1985
Resolved
[D1] SERVICE ALL FIVE LIFERAFTS AND HYDROSTATIC RELEASES. FIVE YEAR INFLATION TEST HAS BEEN EXTEND TO JUNE 1986.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[D2] SERVICE FIXED CO2 SYSTEM INCLUDING TEST OF CABLE PULLS, TIME DELAY MECHANISM; SIRENS; VENTILATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[D9] PROVIDE TWO TOURNIQUETS FOR HOSPITAL/FIRST AID KIT.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E1] OPEN ALL PRESSURE VESSELS FOR INTERNAL EXAM OR HYDROSTATICALLY TEST AT1.25 X MAWP.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E2] TEST ALL PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[D4] WEIGH ALL CO2 CHARGES AND SPARES FOR PORTABLE DRY CHEMICAL EXTINGUISHERS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E11] POST THE PLACARD REQUIRED BY 33 CFR 155.450 "DISCHARGE OF OIL PROHIBITED" IN A CONSPICUOUS PLACE IN THE MACHINERY SPACE.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E12] TEST AIR PURGE ALARM ON DRILLERS CONSOLE.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E13] PROVIDE DOCUMENTATION OF ASME CODE CONSTRUCTION AND IDENTIFICATION AND/OR USCG APPROVAL FOR THE SIX DRY BULK TANKS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[D3] HYDROSTATICALLY TEST PORTABLE CO2 EXTINGUISHERS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E3] PROVIDE DOCUMENTATION OF ASME DESIGN & CONSTRUCTION OF THE FWD STBD WINCH STARTING AIR TANK. REPLACE THE EXISTING RELIEF VALVE WITH ONE RATED FOR OR BELOW MAWP. THIS TANK IS TO REMAIN DISCONNECTED UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E4] REPLACE INOPERATIVE RELIEF VALVES ON SANITARY TANK, POTABLE WATER TANKAND WASH WATER TANK.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E5] TEST OVERSPEED TRIPS ON ALL MAIN PROPULSION AND SHIPS SERVICE DIESEL GENERATORS.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E6] REPAIR INOPERATIVE GENERAL ALARM BELLS #10, #25, #30 AND BELL IN CASING HOLD.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E7] REPLACE BURNED OUT "E" LIGHTS AS NECESSARY THROUGHOUT THE VESSEL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E8] RELABEL "E" LIGHTS WHERE THEY HAVE BEEN PAINTED OVER. (MOON POOL VOIDAND MUD PUMP ROOM)
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E9] LABEL EMERGENCY FUEL OIL SHUT OFF VALVE REACH RODS AT MAIN DECK, PORT AND STARBOARD.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 3 December 1985
Resolved
[E10] LABEL HELO FUELING PUMP EMERGENCY SHUT OFF ON STARBOARD SIDE OF THE HELO DECK.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985
Resolved
ALL MISSING GENERAL ALARM BELLS SHALL BE REPLACED WITH APPROVED BELLS UNLESS IT CAN BE SHOWN THAT THE GENERAL ALARM BELL LOCATIONS ARE IN ACCORDANCE WITH AN APPROVED PLAN.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985
Resolved
THE MISSING GENERAL ALARM BELL AFT OF THE RIG FLOOR SHALL BE REPLACED WITH ONE APPROVED FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985
Resolved
THE GENERAL ALARM BELL IN THE LAUNDRY ROOM ON THE MAIN DECK IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED BELL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985
Resolved
THE GENERAL ALARM BELL ON THE STARBOARD SIDE OF THE GENERATOR IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED BELL.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 23 July 1985
Resolved
THE GENERAL ALARM BELL ON THE 'TWEEN DECK FORWARD OF THE MOON POOL IS MISSING AND SHOULD BE REPLACED WITH AN APPROVED TYPE SUITABLE FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 16 January 1985
Resolved
CONDUCT THE 5 YEAR INFLATION TEST FOR THE LIFERAFT AT STATION 5 AT A COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 16 January 1985
Resolved 16 January 1985
Unknown
Issued 20 December 1984
Resolved
REPAIR OR RENEW LEAKING PIPES OVER ELECTRIC MOTOR FOR NO. 2 DESALINATOR.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE TWO ORANGE SMOKE FLOATING DISTRESS SIGNALS FOR THE LIFEBOATS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE USCG APPROVED EMBARKATION LADDERS FOR THE THE TWO FORWARD LIFERAFTS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
REPLACE MISSING HANDRAIL IN WAY OF CO2 FIXED EXTINGUISHING SYSTEM.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE A SECOND ESCAPE FOR WASHROOM AND RECREATION ROOMS ON THE BOW.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
COMPLETE TEMPORARY REPAIRS FOR ISOLATION OF DECK DRAINS IN THE FORWARD WINDLASS SPACE AND A/C ROOM FROM BERTHING AREAS BELOW. SEAL ALL PIPES LEADING TO AND FROM ROSEBOXES IN THE FORWARD BERTING SPACES PORT AND STBD. COMPLETE PERMANENT REPAIRS PRIOR TO NEXT DRYDOCK EXAM.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 December 1984
Resolved
RENEW HELO-DECK PERIPHERAL NETTING AND NETTING FRAME HINGES WHERE WASTED.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
ISOLATE THE 1JV SOUND POWERED TELEPHONE CIRCUIT FROM THE 3JV CIRCUIT AS ORIGINAL. THE STEERING GEAR SPACE MUST BE ON THE 1JV CIRCUIT.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
RENEW AS ORIGINAL THE PATCHED AND LEAKING FIREMAIN PIPING IN THE MUD PUMP ROOM.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 20 December 1984
Resolved
PROVIDE SIMPLE INSTRUCTIONS INCLUDING SCHEMATIC DIAGRAMS FOR THE FIXED EXTINGUISHING SYSTEM.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE AN AUDIBLE ALARM FOR THE EMERGENCY GENERATOR ENGINE LOW OIL PRESSURE AND HIGH COOLING WATER TEMPERATURE.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE ON BOARD A MINIMUM OF EIGHT USCG APPROVED (UL LISTED MARINE TYPE) PORTABLE FIRE EXTINGUISHERS WITH AII CLASSIFICATION FOR THE ACCOMODATION SPACES.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
WEIGH ALL FIXED AND SEMI-PORTABLE CO2 CYLINDERS. PROVIDE A COPY OF THE SERVICING REPORT SHOWING NET WEIGHTS TO [name withheld].
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE ONE MESA OR MSHA APPROVED FIRST AID KIT ON BOARD.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
RENEW OR REPAIR WASTED AND UNCOVERED BATTERY BOXES.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Unknown
Issued 20 December 1984
Resolved
PROVIDE RELIEF VALVES WITH HAND LIFTING DEVICES FOR THE THREE INSTALLED AIRDRYER PRESSURE VESSELS.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984