← All vessels
CROWN OPAL
CROWN OPAL is a 1997 freight ship. The Coast Guard has recorded 43 inspections since 1998, most recently in July 2026, along with 13 deficiencies and 7 operational controls.
Records from 1998 to 2026. Most recent: inspection, 31 July 2026.
- Built
- 1997
- Last inspected
- 31 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9128063 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6DW4
455767
Flag
BAHAMAS, THE
—
Maury page id
psix-455767
Inspections, by type
…with no type recorded18
Years with a record
21 calendar years (1998–2026)
The 43 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it10316 - Dead Weight, Ton
16522 - Displacement, Ton
10519 - Convention (Subpart B), Gross Ton
5406 - Convention (Subpart B), Net Ton
16522 - Displacement, Ton
10519 - Convention (Subpart B), Gross Ton
5406 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 43
31 July 2026
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8450485
8 July 2024
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7940357
29 December 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7843332
17 January 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7622152
24 February 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7401175
4 March 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7150695
7 December 2020
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7107364
3 December 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7105996
16 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6927312
6 September 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6798050
19 April 2019
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6666394
16 February 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6356157
15 February 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6355629
12 February 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6353968
10 January 2012
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 4221600
10 January 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4223732
26 October 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3877854
1 October 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3861298
12 January 2009
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3394732
9 January 2009
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3391166
23 September 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3331101
16 June 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3238499
10 May 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3203189
26 March 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3171619
14 March 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3164692
29 June 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2977774
29 May 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2944444
16 May 2007
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2931847
5 August 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2736998
8 May 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2643613
20 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2519409
19 October 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2517945
23 April 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2381055
26 October 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2228457
1 July 2004
PII Safety Exam · STCW 95 Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2118309
10 January 2004
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1954827
3 May 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611061
2 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 286816
23 January 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 274040
27 November 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812959
5 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 426297
26 March 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414154
16 January 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411877
Deficiency record · 13
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 September 2019
Resolved
After survey, no change shall be made to equipment without the sanction of the Administration. "A" Structural fire protection in the CO2 room was held in place by duct tape, exposing metal overhead. 74SOLAS(14)I/11(b) - 16ac
14 - Pollution Prevention › 147 - Anti-Fouling › Paint condition
Issued 6 September 2019
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks must; remove fouling organism from vessel hull on a regular basis. Vessel hull had several areas of marine growth at and below the waterline. 33CFR151.2050(f) - 40c
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 6 September 2019
Resolved
A daylight signaling lamp using electrical power shall not be solely dependent on ship's power supply. Lamp could only be operated when connected to ships power supply. 74SOLAS(14)V/19.2.2.2 - 50ac
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 September 2019
Resolved
Operating instructions with a block diagram showing change-over procedures for steering shall be permanently displayed in the steering compartment. There was no block diagram present in the steerng compartment. 74SOLAS(14)V/26.3.1 - 10c
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 1 October 2010
Resolved
LIFEBOAT REQUIRED WITH AN OPERATIONAL RUDDER. SHIP STARBOARD LIFEBOAT RUDDER CATCHES FLEXING FIBERGLASS SUPPORT AND CAUSES IRRATIC MOVEMENT.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 January 2009
Resolved
Several sections of deck hand rail on port side adjacent to cargo holds #3 and #4 have been damaged and detached. this condition does not provide adequate protection to the crew and creates a potential safety hazard. Vessel shall repair hand rails and provide statement from master attesting to satisfactory repairs.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 26 March 2008
Resolved
Secondary Radar is not functioning properly according to Class surveyor.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 March 2008
Resolved
Received inbound letter of deviation request for secondary radar. Vessel shall submit certified technician's report attesting to proper operation prior to departure from San Juan.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 16 May 2007
Resolved
Emergency generator is equipped with 1 electric starter and 2 separate sets of batteries. Generator fails to start in the No. 2 set position. Emergency generator must prove to operate from 2 sources of power, to the satisfaction of Coast guard Inspector.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 16 May 2007
Resolved
Provide Class report authorizing the use of Marine Deep Cycle Battery, SRM-29-13" L x 6 -3/4 W x 10" H as starting batteries for the Emergency Generator. Provide fax copy of report to USCG
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 23 April 2005
Resolved
Port and starboard fuel oil vent flame screens wasted. Replace with new screens.
Unknown
Issued 16 January 1998
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR IN PRESENCE OF COAST GUARD BY NEXT U.S. PORT.
Unknown
Issued 16 January 1998
Resolved
CONDUCT BOAT AND FIRE DRILLS IN PRESENCE OF COAST GUARD PERSONNEL AT NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.