Records from 1997 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 52
28 April 2026
Vessel Attendance · Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8356395
17 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8269818
24 April 2025
In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8116221
27 December 2024
In-Service Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Deadweight Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8051199
27 August 2024
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7990511
1 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7905393
1 November 2023
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7819482
26 April 2023
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7676080
8 September 2022
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7554388
20 April 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7435922
31 August 2021
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7302110
28 April 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7184771
29 April 2020
MTSA Verification · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6944333
1 November 2019
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6846921
14 May 2019
Examination of Repairs
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6683935
23 April 2019
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6670279
10 May 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6410683
5 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6197738
19 May 2017
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6150053
22 November 2016
Examination of Repairs
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6045901
21 November 2016
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6045404
2 November 2016
MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6033762
18 October 2016
In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6029345
26 April 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5862619
6 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4335817
15 May 2012
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4311793
16 April 2009
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3453931
29 October 2008
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3361646
28 October 2008
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3354179
15 April 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3168263
30 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2946238
16 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2932208
24 April 2007
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2914785
11 April 2007
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2905715
3 April 2007
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2900885
5 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2641316
19 April 2006
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2628441
22 April 2005
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2340897
26 July 2004
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2145958
27 April 2004
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2053582
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1969266
11 April 2003
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1774636
6 March 2003
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1753655
13 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1615968
9 May 2002
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1614869
3 March 2001
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1453883
4 May 2000
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1448107
3 May 1999
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1450333
6 May 1998
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1125757
5 October 1997
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1416569
21 May 1997
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1404377
7 May 1997
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1097483
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 April 2026
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB battery was found to be out of date. Vessel cannot operate beyond 3 miles from coastline of Great Lakes.
46 CFR 117.64
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 May 2026
Resolution: New cert and battery
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 28 April 2026
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] exit from engineroom side was not marked. 46 CFR 122.606
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: Exit market
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2026
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 1 to § 118.500(b) and other provisions of this section. Machinery space: Minimum required rating 40-B:C, quantity and location 1 in the vicinity of the exit. Vessel did not have portable fire extinguisher in the the vicinity of the exit of the engine room. 46 CFR 118.500(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2026
Resolved 15 May 2026
Resolution: F/E placed at entrance
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 April 2021
Resolved
Floating water light found to be inoperable.
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Waterlight replaced on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021
Resolved
Fire nozzle found unserviceable due to cracked handle.
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Fire nozzle replaced on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2021
Resolved
Fuel leak found on STBD MDE fuel return line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2021
Resolved 28 April 2021
Resolution: Fuel line replaced with approved hose/fittings.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2021
Resolved
Fire pump pressure gauge found inoperable.
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: New gauge installed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 April 2020
Resolved
9 Life floats retro-reflective tape is worn and shall be replaced with the proper SOLAS Retro-reflective as required by the regulations. Vessel owner shall replace the Worn Retro-reflective tape within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: Vessel Rep. sent photos of the Life Floats with new Retro-Reflective tape. All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2019
Resolved
Engine room electrical installation between Main engines needs a non-conductive mat on the deck in front of the electrical installation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 25 April 2019
Resolution: Miller Boat company put a non-conductive mate in front of the electrical installation between the engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 April 2019
Resolved
Water tight door at the entry to the Engine room does not seal properly. Door seal failed a chalk test. door shall be repaired to seal properly when closed and dogged down.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2019
Resolved 25 April 2019
Resolution: Watertight door at the entry to the engine room was ajusted and rechalk tested sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 April 2019
Resolved
Emergency Fuel shut off pull station not operational. Cable is unable to pull valve handle to the closed position. Vessel repaired cable and is now operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2019
Resolved 23 April 2019
Resolution: Emergecy Fuel Shut off pull station was fixed and now operating as designed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 15 May 2012
Resolved
Repair sewage leak on sewage tank discharge pump suction line.
Condition: Damaged By Earlier Event
Due 22 May 2012
Resolved 19 May 2012
Resolution: Suction replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 15 May 2012
Resolved
Replace retroreflective tape on ring buoy on upper deck.
Condition: Damaged By Earlier Event
Due 22 May 2012
Resolved 19 May 2012
Resolution: Retro tape renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2012
Resolved
Replace missing light fixture in sewage tank compartment overhead.
Condition: Damaged By Earlier Event
Due 22 May 2012
Resolved 19 May 2012
Resolution: New light fixture installed.
Lifesaving › Lifefloat › Paddle
Issued 15 May 2012
Resolved
Provide two paddles for each lifefloat on board.
Condition: Damaged By Earlier Event
Due 16 May 2012
Resolved 19 May 2012
Resolution: Paddles replaced and stenciled.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 15 May 2012
Resolved
Update senior deckhand designation list in pilothouse.
Due 22 May 2012
Resolved 19 May 2012
Resolution: Senior deck hand list updated.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2012
Resolved
Conduct man overboard training and conduct a satisfactory man overboard drill.
Action required: 705 - Other - as specified
Due 22 July 2012
Resolved 1 July 2013
Electrical › Electrical Distribution System (service) › Cable
Issued 15 April 2008
Resolved
Vessels has welding cable for generator starting and on battery charger. Must meet requirements in 46 CFR 183.340(d). Must be completed by next drydock.
Action required: 705 - Other - as specified
Due 5 April 2012
Resolved 23 April 2010
Resolution: Verified cable has been replaced
Lifesaving › Lifefloat › Paddle
Issued 15 April 2008
Resolved
Vessels lifefloat paddles not servicable, wood delaminating and plastic cracked in half.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 29 October 2008
Resolution: Replaced as original.
Lifesaving › Lifefloat › Serviceable
Issued 15 April 2008
Resolved
Lifefloat on top of pilot house are discolored from stack soot. Needs to be cleaned/and are renewed to seviceable condition.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 29 October 2008
Resolution: Lifefloat cleaned.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 15 April 2008
Resolved
Vessel's first aid kit had out of date supplies.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 29 October 2008
Resolution: First aid kit renewed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2007
Resolved
Replace port gen set jacket water hose to keel cooler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 10 May 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 April 2007
Resolved
Replace frequency meter.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 10 May 2007
Engineering › Compressed Air System (start air) › Control Gear
Issued 11 April 2007
Resolved
Air compressor high psi cut-out switch missing cap.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 10 May 2007
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 11 April 2007
Resolved
STBD r/g cooler hose chaffing need chaffing gear or hang hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2007
Resolved 10 May 2007
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 April 2007
Resolved
Complete security drill by 23 Apr 07.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 April 2007
Resolved 23 April 2007
Resolution: Vessel conducted security drill, will check log upon checking the rest of the 835 items.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 April 2007
Resolved
Complete annual security plan audit by 16 May 2007
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 11 April 2007
Resolved
Provide proof of fire extinguisher servicing both Portable/fixed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 10 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 3 April 2007
Resolved
Repair damaged area with 18"x18" insert on the port bow forward blow the main deck.
Action required: 705 - Other - as specified
Resolved 16 April 2007
Resolution: Saticfactory inspection of the completed repair on the port bow.
Construction/Loadline › Markings › Load Line Mark
Issued 3 April 2007
Resolved
Permenantly mark the maximum load line mark on the hull.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 16 April 2007
Resolution: The maximum load line was welded to the hull and painted white.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006
Resolved
Ensure new fuel flow meter cables are properly secured in a wire run as per 46 CFR 183.01-15 and not secured to the vessel's installed fire suppression system.
Action required: 705 - Other - as specified
Due 31 December 2006
Resolved 10 May 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 April 2006
Resolved
Ensure that all the vessel's float lights have individual float lights attached as per 46 CFR 180.15-1 and 46 CFR 180-15-5.
Due 4 May 2006
Resolved 4 May 2006
Resolution: Vessels rep''s added new lights to each float, tested all new lights with sat results.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 April 2005
Resolved
Ensure all first aid supplies are current and remove old expired supplies.
Due 19 May 2005
Resolved 17 May 2005
Resolution: Millers crew replaced all expired items, asprin exp date is 05/06, eyewash 06/07.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 April 2005
Resolved
Ensure all main deck vent closures properly line up and close.
Due 19 May 2005
Resolved 17 May 2005
Resolution: Millers crew cleaned up the threads and re-tested all the closures with sat results.
Construction/Loadline › Markings › Load Line Mark
Issued 26 July 2004
Resolved
Next time the vessel is dry-docked for any reason, permanently install (weld or punch) vessel maximum loading mark as per stability letter. Mark is currently painted on the hull.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 10 May 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 27 April 2004
Resolved
Install permanent loading marks on hull.
Condition: Unknown
Due 29 May 2004
Resolved 26 July 2004
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 April 2004
Resolved
Install ventilation closures for Engine Room intake and exhaust.
Condition: Design Flaw
Due 29 May 2004
Resolved 26 July 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 27 April 2004
Resolved
Proper labeling of life float/BA with vessels name, renew retro, stowage of line, and label paddles with vessels na,e. LEGACY COMPONENT DESC: Outfitting
Condition: Improper Installation
Due 29 May 2004
Resolved 26 July 2004
Lifesaving › Visual Distress Signals (General)
Issued 11 April 2003
Resolved
Replace line on two float lights connected to aft life floats
Due 11 April 2003
Resolved 11 April 2003
Stability
Issued 11 April 2003
Resolved
Label upper deck max passengers on top deck limited to 150.
Due 11 April 2003
Resolved 11 April 2003
Stability › Watertight Integrity
Issued 11 April 2003
Resolved
Replace pin in the port side mid ships manual vent cover.
Due 11 April 2003
Resolved 11 April 2003
Deck/Cargo
Issued 11 April 2003
Resolved
Fix and clean vent cover in female head.
Due 11 April 2003
Resolved 11 April 2003
Deck/Cargo
Issued 11 April 2003
Resolved
Clean vent in male head.
Due 11 April 2003
Resolved 11 April 2003
Lifesaving › Buoyant Apparatus
Issued 13 May 2002
Resolved
Condition: Unknown
Due 13 May 2002
Resolved 13 May 2002
Electrical
Issued 6 May 1998
Resolved
HARDWIRE MSD PUMP AND FLOAT SWITCH
Condition: Unknown
Due 15 May 1998
Resolved 21 May 1998
Lifesaving
Issued 7 May 1997
Resolved
Provide proper quantity and type survival craft as per 46 CFR 117.206._x001C_ The vessel's route shall be restricted to a ferry schedule between Catawba and South Bass Island.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997
Lifesaving
Issued 7 May 1997
Resolved
Conduct rescue and emergency drills in the presence of a CG Marine Inspector not later than 30 May 1997.
Condition: Unknown
Due 7 May 1997
Resolved 7 May 1997