Inspection history · 20
2 April 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8345090
7 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8291387
8 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108126
20 June 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7938964
7 December 2023
Simplified Stability Test · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7836222
18 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7671709
14 April 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668435
7 March 2023
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648011
13 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7420347
17 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7228040
3 March 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149548
11 May 2020
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950520
22 April 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6667624
25 February 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6631790
3 December 2018
Drydock Exam · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6591258
23 April 2018
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6397388
26 January 2018
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6341473
19 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6126219
25 April 2016
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5861888
28 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5805156
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 April 2025
Resolved
Vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Update outdated radio safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 20 April 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2025
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041.
Acquire ammonia inhalants.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 20 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 April 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:
Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag;
Acquire appropriate rated link.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 20 April 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 January 2024
Resolved
Stbd engine bottom plating was found holed, crop and renew wasted area.
Action required: 705 - Other - as specified
Resolved 17 January 2024
Resolution: Hull plating was cropped and renewed in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2023
Resolved
Vessel diesel fuel vent IWO stbd gunwale found to be installed without using a flame screen. Install flame screen consisting of single screen of corrosion resistant wire at least 30x30 mesh.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Picture sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2023
Resolved
Engine serpentine belt found to be missing. Install protective covering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 4 May 2023
Resolution: Picture sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 April 2023
Resolved
Galley deep freezer found to be not secured to the deck. Ensure freezer is installed to prevent movement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Pic sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023
Resolved
Electrical outlet IWO galley deep freezer found to be missing protective face plate. Install face plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Pic sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023
Resolved
Electrical outlet IWO galley sink found to be missing protective face plate. Install face plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Picture sent rectifying def
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 April 2022
Resolved
The aft bulkhead penetrations in the bait tank void are not sealed. Provide proper sealant around all penetrations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received pictures of the holes sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022
Resolved
Discovered improperly dead ended electrical conducter in the bait tank void. Remove cable or install into an approved electrical J-box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022
Resolved
Discovered electrical J-box not securely mounted in galley forward void. Re-secure to satisfaction of attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022
Resolved
Humidifier electrical connections not terminated into J-box within the galley forward void. Repair to the satisfaction of the attending USCG marine inspector. Cite: 46 CFR 183.300(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received pictures of the deficiency corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022
Resolved
Forward bulkhead electrical cable found to be improperly dead-ended in galley forward void. Remove or install into an approved J-box. Cite: 46 CFR 183.300(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2022
Resolved
Port & STBD flex tubing from overhead tank missing hose clams at each end in the galley forward void. Install hose clamps to satisfaction of attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of the newly installed clamps.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 April 2022
Resolved
Life float paddles were cracked and weathered. Replace the cracked paddles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of the new vesssel's newly acquired paddles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2021
Resolved
Portable fire extinguisher bracket to bottle missing proper securing strap.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
Engine room electrical panel circuit breaker for generator not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
STBD side light fixture on bulkhead missing light diffuser.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021
Resolved
STBD Aft overhead light fixture not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021
Resolved
Battery box center battery not blocked and chock to prevent movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2021
Resolved
Engine room aft bulkhead penetrations not properly sealed
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 June 2021
Resolved
Provide DSC radio with vessel MMSI number & Lat and Long.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 17 June 2021
Resolved
Provide valid Alcohol swabs on-board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 June 2021
Resolved
Connect remote shut-off to valve in forepeak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 17 June 2021
Resolved
Enroll new crew member in Drug & Alcohol program and update crew list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2021
Resolved
Repair 04 Life Floats and properly display manufactures placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 9 March 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
Show Proper operation of all Navigation Lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 May 2020
Resolved
Replace EPIRB battery. Vessel's route reduced to limited coast-wise until the deficiency is resolved.
Action required: 705 - Other - as specified
Resolved 28 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2020
Resolved
Provide plan for generator replacement. Have a Coast Guard Marine Inspector witness an operational test of the completed generator replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2020
Resolved 2 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2020
Resolved
Reinstall galley vent ducting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2020
Resolved 28 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2020
Resolved
Replace 01 life jacket light as identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2020
Resolved 28 May 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 11 May 2020
Resolved
Replace gasket to galley hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2020
Resolved 28 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019
Resolved
Provide vessel with enough child sized life jackets for every person under 90 lbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 10 May 2019
Resolution: Vessel rep purchased an additional 15 child size life jackets to accomidate larger groups of children.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 February 2019
Resolved
Make the vessel hull ready for inspection in the way of the damage to teh port side rub rail from the allision with the West Mission Bay Bridge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2019
Resolved 25 February 2019
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 April 2018
Resolved
Provide ammeterfor generator more than 50volts
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Ammeter installed
Accommodation/Occupational Safety › Ventilation › General
Issued 23 April 2018
Resolved
Renew galley exhaust vent
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Exhaust vent renewed
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 April 2018
Resolved
Properly secure portside side rail IWO midships
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Rail was properly secured.
Engineering › Bilge Water Management System › Hose
Issued 23 April 2018
Resolved
Install double clamps on bilge and generator hoses
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Hose clamps were added to bilge and generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 April 2018
Resolved
Install guard on bilge pump coupling
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 May 2018
Resolved 24 May 2018
Engineering › Bilge Water Management System › Pump
Issued 23 April 2018
Resolved
Renew lovejoy coupling on bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Coupling renewed
Navigation › Piloting/Steering › Marine Charts
Issued 19 April 2017
Resolved
Provide current charts
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Provided current charts.
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2017
Resolved
Repair top fwd lifefloat IAW manufacturers instructions.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Repaired top forward lifefloat using [name withheld] manufacture recommended repair method.
Engineering › Fuel Oil Service System › Piping
Issued 19 April 2017
Resolved
Label fuel fill
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Labeled fuel fills.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 April 2017
Resolved
Pax count reduced to 56 on lim coastwise route until 60 lifejackets on board.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Provided 04 new lifejackets.