Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCF9320
Flag
UNITED STATES
Maury page id
psix-45587

Documentation record

Registered dimensions (L × B × D)59.7 ft × 20.0 ft × 5.6 ft
Registered tonnagegross 49 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAN DIEGO, CA, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

2 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8345090
7 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8291387
8 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108126
20 June 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7938964
7 December 2023 Simplified Stability Test · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7836222
18 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7671709
14 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668435
7 March 2023 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7648011
13 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7420347
17 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7228040
3 March 2021 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149548
11 May 2020 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950520
22 April 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6667624
25 February 2019 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6631790
3 December 2018 Drydock Exam · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6591258
23 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6397388
26 January 2018 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6341473
19 April 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6126219
25 April 2016 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5861888
28 January 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5805156

Deficiency record · 45

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 April 2025 Resolved
Vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Update outdated radio safety certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 20 April 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 April 2025 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. Acquire ammonia inhalants.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 20 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 8 April 2025 Resolved
The float-free link required by § 180.130(a)(1) must be: Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag; Acquire appropriate rated link.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 20 April 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 January 2024 Resolved
Stbd engine bottom plating was found holed, crop and renew wasted area.
Action required: 705 - Other - as specified
Resolved 17 January 2024
Resolution: Hull plating was cropped and renewed in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2023 Resolved
Vessel diesel fuel vent IWO stbd gunwale found to be installed without using a flame screen. Install flame screen consisting of single screen of corrosion resistant wire at least 30x30 mesh.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Picture sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 April 2023 Resolved
Engine serpentine belt found to be missing. Install protective covering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 4 May 2023
Resolution: Picture sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 April 2023 Resolved
Galley deep freezer found to be not secured to the deck. Ensure freezer is installed to prevent movement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Pic sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023 Resolved
Electrical outlet IWO galley deep freezer found to be missing protective face plate. Install face plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Pic sent rectifying def
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023 Resolved
Electrical outlet IWO galley sink found to be missing protective face plate. Install face plate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2023
Resolved 1 May 2023
Resolution: Picture sent rectifying def
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 April 2022 Resolved
The aft bulkhead penetrations in the bait tank void are not sealed. Provide proper sealant around all penetrations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received pictures of the holes sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
Discovered improperly dead ended electrical conducter in the bait tank void. Remove cable or install into an approved electrical J-box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
Discovered electrical J-box not securely mounted in galley forward void. Re-secure to satisfaction of attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
Humidifier electrical connections not terminated into J-box within the galley forward void. Repair to the satisfaction of the attending USCG marine inspector. Cite: 46 CFR 183.300(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received pictures of the deficiency corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
Forward bulkhead electrical cable found to be improperly dead-ended in galley forward void. Remove or install into an approved J-box. Cite: 46 CFR 183.300(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of proper dead-ending of wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2022 Resolved
Port & STBD flex tubing from overhead tank missing hose clams at each end in the galley forward void. Install hose clamps to satisfaction of attending USCG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of the newly installed clamps.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 April 2022 Resolved
Life float paddles were cracked and weathered. Replace the cracked paddles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 5 May 2022
Resolution: Received picture of the new vesssel's newly acquired paddles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2021 Resolved
Portable fire extinguisher bracket to bottle missing proper securing strap.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021 Resolved
Engine room electrical panel circuit breaker for generator not labeled.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021 Resolved
STBD side light fixture on bulkhead missing light diffuser.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 June 2021 Resolved
STBD Aft overhead light fixture not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2021 Resolved
Battery box center battery not blocked and chock to prevent movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2021 Resolved
Engine room aft bulkhead penetrations not properly sealed
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 27 July 2021
Resolution: Vessel rep emailed pictures.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 June 2021 Resolved
Provide DSC radio with vessel MMSI number & Lat and Long.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 17 June 2021 Resolved
Provide valid Alcohol swabs on-board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 June 2021 Resolved
Connect remote shut-off to valve in forepeak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 17 June 2021 Resolved
Enroll new crew member in Drug & Alcohol program and update crew list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2021 Resolved
Repair 04 Life Floats and properly display manufactures placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 9 March 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021 Resolved
Show Proper operation of all Navigation Lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 July 2021
Resolution: Vessel rep emailed pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 May 2020 Resolved
Replace EPIRB battery. Vessel's route reduced to limited coast-wise until the deficiency is resolved.
Action required: 705 - Other - as specified
Resolved 28 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2020 Resolved
Provide plan for generator replacement. Have a Coast Guard Marine Inspector witness an operational test of the completed generator replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2020
Resolved 2 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2020 Resolved
Reinstall galley vent ducting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2020
Resolved 28 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2020 Resolved
Replace 01 life jacket light as identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2020
Resolved 28 May 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 11 May 2020 Resolved
Replace gasket to galley hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2020
Resolved 28 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019 Resolved
Provide vessel with enough child sized life jackets for every person under 90 lbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 10 May 2019
Resolution: Vessel rep purchased an additional 15 child size life jackets to accomidate larger groups of children.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 February 2019 Resolved
Make the vessel hull ready for inspection in the way of the damage to teh port side rub rail from the allision with the West Mission Bay Bridge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2019
Resolved 25 February 2019
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 April 2018 Resolved
Provide ammeterfor generator more than 50volts
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Ammeter installed
Accommodation/Occupational Safety › Ventilation › General
Issued 23 April 2018 Resolved
Renew galley exhaust vent
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Exhaust vent renewed
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 April 2018 Resolved
Properly secure portside side rail IWO midships
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Rail was properly secured.
Engineering › Bilge Water Management System › Hose
Issued 23 April 2018 Resolved
Install double clamps on bilge and generator hoses
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Hose clamps were added to bilge and generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 April 2018 Resolved
Install guard on bilge pump coupling
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 May 2018
Resolved 24 May 2018
Engineering › Bilge Water Management System › Pump
Issued 23 April 2018 Resolved
Renew lovejoy coupling on bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2018
Resolved 24 May 2018
Resolution: Coupling renewed
Navigation › Piloting/Steering › Marine Charts
Issued 19 April 2017 Resolved
Provide current charts
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Provided current charts.
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2017 Resolved
Repair top fwd lifefloat IAW manufacturers instructions.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Repaired top forward lifefloat using [name withheld] manufacture recommended repair method.
Engineering › Fuel Oil Service System › Piping
Issued 19 April 2017 Resolved
Label fuel fill
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Labeled fuel fills.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 April 2017 Resolved
Pax count reduced to 56 on lim coastwise route until 60 lifejackets on board.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Provided 04 new lifejackets.