MAURY USCG vessel records Sign in
← All vessels

OBERON

OBERON is a 1995 freight ship. The Coast Guard has recorded 73 inspections since 1997, most recently in April 2024, along with 46 deficiencies and 9 operational controls.

Records from 1997 to 2024. Most recent: inspection, 6 April 2024.

Built
1995
Last inspected
6 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9106467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
455877
Flag
GERMANY
—
Maury page id
psix-455877

Inspections, by type

…with no type recorded32
Years with a record 14 calendar years (1997–2024)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8633 - Convention (Subpart B), Gross Ton
3456 - Convention (Subpart B), Net Ton
9200 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 73

6 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890943
30 March 2009 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3442707
28 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3335780
23 April 2008 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3190749
30 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3012398
6 July 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2985654
4 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2951659
10 April 2007 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2904897
3 April 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2900624
27 February 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2878686
12 February 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2870933
2 February 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2865864
29 August 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2762884
6 June 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2671751
5 June 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2670850
25 April 2006 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2632825
11 April 2006 MARPOL Annex V Examination · ISPS II Exam · NPV Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2621809
3 April 2006 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2615228
8 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2598340
28 February 2006 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2594420
25 October 2005 Ballast Water Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2520014
30 September 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2504509
23 June 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2404509
2 June 2005 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2378135
27 May 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2369606
24 May 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2367692
17 May 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2360012
29 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2345780
27 April 2005 Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2342218
19 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2337557
14 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2333564
14 April 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2333757
8 April 2005 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2329329
4 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2326876
3 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2325402
1 April 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2324363
30 March 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2323154
26 March 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2320263
26 March 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2320566
16 March 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2312989
4 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2286503
14 October 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2220584
29 June 2004 ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2110406
20 May 2004 PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2116067
24 February 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2012074
17 February 2004 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2007448
2 December 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1957462
19 June 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1821569
22 April 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1776208
24 March 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1762275
28 February 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1750901
27 January 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1730309
26 August 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1665782
23 July 2002 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1649207
18 February 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1489616
23 January 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1480705
4 October 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 467288
25 July 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 719341
18 June 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 291020
7 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 287689
24 September 2000 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 282605
11 September 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 36351
11 July 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 279450
19 June 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 278997
7 March 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 275343
9 February 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 274397
27 January 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 273458
12 July 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 430488
9 June 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 429398
11 January 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 424878
9 June 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 416652
24 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410307
27 May 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404040

Deficiency record · 46

Electrical › Lighting (service) › Lighting Fixture
Issued 30 March 2009 Resolved
Paint locker and battery room lights are standard fluorescent lights with insufficient shielding. No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those in compartments assigned to accumulator batteries and paint lockers.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 22 April 2011
Resolution: Deficiency found to be rectified during a PII/ISPSII exam by Sec Miami 22APR11.
Fire Fighting › Grease Extraction Hood › General
Issued 23 April 2008 Resolved
Stove top hood and vent duct work have an excessive build up of grease, creating a fire hazard. Hood and vent must be cleaned prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2008
Resolved 30 April 2008
Resolution: Vessel submitted a Class report attesting to the correction of deficiency.
Fire Fighting › Grease Extraction Hood › General
Issued 23 April 2008 Resolved
Stove top hood vent screens are missing, allowing grease to enter the duct work. Replace the screen prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2008
Resolved 30 April 2008
Resolution: Vessel submitted a Class report attesting to the correction of deficiency.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 10 April 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 12 April 2007
Resolution: Received medical fitness report stating that [name withheld] is fit for full duty.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 February 2007 Resolved
Vessel has not submitted a Vessel Response Plan according to the E-VRP website. In accordance with ALCOAST 398/05 a new regulation is going to be issued for non-tank vessels over 400 gross tons to submit a Vessel response plan.
Action required: 705 - Other - as specified
Resolved 27 February 2007
Resolution: Verified in MISLE Interm VRP has been submitted.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 11 April 2006 Resolved
Garbage record book not certified as correct by master/captain since December 2005.
Action required: 705 - Other - as specified
Resolved 11 April 2006
Resolution: Corrected on the spot to the satisfaction of the attending Coast Guard Marine Inspector.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Navigation Watch Rating
Issued 28 February 2006 Resolved
Provide flag state acceptance of personnel with non flag state II/4 and III/4 certificates of competency for " Ratings forming part of a navigational watch " and " Ratings forming part of an engineering watch" as per safe manning certificate.
Due 27 March 2006
Resolved 3 March 2006
Resolution: Def corrected
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 April 2005 Resolved
Fire doors in engine room and steering room held back with rope ties.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 27 May 2005
Resolution: DEF rectified on-scene.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 27 April 2005 Resolved
Emergency escape breathing device by aft engine room door discharged. Replace with charged Device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 2 June 2005
Resolution: def corrected
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 April 2005 Resolved
Leaking fuel oil piping and sludge oil delivery piping to Waste Oil Tank: pipe lagging soaked with oil on fuel oil line forward end of main diesel engine, port side overhead lower level of engine room. Pipe lagging soaked with oil and oil residue on flange of sludge oil delivery piping to waste oil tank, engine room lower level port side. CPP System Gauge Valves leaking oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 17 May 2005
Resolution: Received class report attesting to the fact the above items have been cleared.
Engineering › Bilge Water Management System › Piping
Issued 27 April 2005 Resolved
Section of pipe missing from Discharge Piping from Stern Tube to Tank 16. Soft patch on Bilge System Return Line to Bilge Overflow Tanks 31 and 32.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 17 May 2005
Resolution: Class [name withheld] stating hand pump reinstalled where pipe was missing and soft patch was renewed with new pipe flange to flange.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 14 April 2005 Resolved
Vessel lost STBD anchor, including canter shackle during maneuver in Jacksonville. New/Recovered anchor including canter shackle to be fitted. To sat of class.
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 17 May 2005
Deck/Cargo › Cargo Transfer (solid) › General
Issued 14 April 2005 Resolved
Crane #1: Procedure for repair of cracks at jib lower crossbeam support to be completed by no later than 05/31/2006
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 30 September 2005
Deck/Cargo › Cargo Transfer (solid) › General
Issued 14 April 2005 Resolved
Crane #2: Procedure for repair of cracks at jib lower crossbeam support to be completed by no later than 05/31/2006
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 30 September 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 4 April 2005 Resolved
Anchor Winch on Port Side inoperative. Make repairs to winch to the satisfaction of class prior to 03 MAY 05. SOLAS 74 Amend 1/11
Action required: 705 - Other - as specified
Due 3 May 2005
Resolved 19 April 2005
Resolution: Port Anchor winch on port side operational.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 4 April 2005 Resolved
In reference to item #1 above. Demonstrate proper deployment and retrieval of port anchor to the satisfaction of a coast guard inspector. SOLAS 74 Amend 1/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: Port anchor deployed and retrieved in the presence of a Coast Guard Marine Inspector.
Stability › Weathertight Integrity › General
Issued 4 April 2005 Resolved
Vacuum seals removed from hatch covers creating non weathertight hatch covers. Provide class society recommendation for Coast Guard Review prior to departure. ICLL 1966 ANNEX 1 2/16 and ART 15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: Class Society issued temporary Load line Certificate after conducting on board survey of hatch covers and bilge pumping arrangement. Temporary measures taken ensuring hatch covers are weather tight to the satisfaction of class.
Construction/Loadline › Penetrations › Gasket
Issued 3 April 2005 Resolved
Vacuum seals removed from hatch covers creating a non watertight hatch cover. Return hatch covers to original configuration to the satisfaction of class prior to departure. ICLL 1966 Annex I 2/16 and Article 15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: Reissued requirement as #3 in this activity.
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 3 April 2005 Resolved
Ballast tank level indicators inoperative. Make repairs to ballast tank level indicators to the satisfaction of class. Until corrected make adequate ballast tank soundings not limited to but at a minimum after any ballast operation. SOLAS 74 AMEND 1/11
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 30 September 2005
Deck/Cargo › Cargo Transfer (solid) › General
Issued 3 April 2005 Resolved
#2 cargo crane has serious hydraulic leaks. Make repairs to crane prior to using crane to the satisfaction of class. No operations to be conducted with #2 crane until repaired to the satisfaction of class. SOLAS 74 Amend 1/11 and MARPOL annex I
Action required: 705 - Other - as specified
Resolved 13 April 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 3 April 2005 Resolved
Anchor winch on port side inoperative. Make repairs to winch to the satisfaction of class prior to 03 MAY05. SOLAS 74 Amend I/II
Action required: 705 - Other - as specified
Due 3 May 2005
Resolved 4 April 2005
Resolution: Reissued requirement as deficiency #1 in this activity.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2005 Resolved
Sludge system piping has been altered with the addition of a pneumatic pump and crossover pipe installed between bilge system at the top of drain tank #9. Provide acceptance of current arrangement by class or restore to original approved system prior to 03 MAY 2005. MARPOL ANNEX I
Action required: 705 - Other - as specified
Due 3 May 2005
Resolved 19 April 2005
Resolution: Classification Society approved installation, stating that no overboard discharge of sludge possible with current arrangement. Class Stamped Chief engineers modified drawing of system showing the interconnection of the system.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2005 Resolved
Pipe for OWS discharge has hole in it approximately 2 feet from overboard valve. Make repairs to the satisfaction of class prior to next U. S. Port MARPOL ANNEX I/4
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 13 April 2005
Resolution: Pipe temp repaired by overwelding hole and tested for leaks. Vessel to have permanent repairs 30APR05
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 3 April 2005 Resolved
Echo depth sounder recorder is inoperative. Repair to the satisfaction of a Coast Guard Inspector prior to 17 APR 05. 33 CFR 164.35(i)
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 19 April 2005
Resolution: Proper operation of recorder witnessed by Coast Guard Inspector.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 3 April 2005 Resolved
Maneuvering Fact Sheet does not include time and distance to stop from a loaded condition. Provide information on maneuvering Fact Sheet prior to 17 APR 05 to the satisfaction of a Coast Guard Inspector. 33 CFR 164.35(g)(2)
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 19 April 2005
Resolution: Manuvering fact sheet complete.
Construction/Loadline › Hull › Bottom Plating
Issued 1 April 2005 Resolved
Provide damage assessment with itemized costs for the grounding in the vicinity of Krause Lagoon.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2005
Resolution: Damage assessment with itemized costs received this date.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 26 March 2005 Resolved
Vessel failed to follow proper procedures as required by the SMS, such as adequate watch arrangements and relief of watch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: Vessel was required to conduct External ISM Audit that addressed proper procedures as required in SMS.
Personnel › Training › Familiarization Training
Issued 26 March 2005 Resolved
[name withheld] was unfamiliar with shipboard operations. Officer was newly assigned as [name withheld] to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: ISM External Audit performed vessel received Major non conformity that was downgraded to non conformity after corrective action from company was accepted by the auditor.
Personnel › Training › Watchkeeping
Issued 26 March 2005 Resolved
A proper look-out was not maintained at all times in compliance with rule 5 of the International regulations for preventing collisions at sea, 1972
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: During External ISM Audit vessel received Major non conformity downgraded to non conformity after company corrective action to provide a lookout as required by Flag State during period of darkness was accepted by Auditor.
Personnel › Training › Watchkeeping
Issued 26 March 2005 Resolved
[name withheld] assigned duty as officer in charge of watch was not provided with a minimum of 10 hours of rest in any 24-hour period. Member had a total of four hours of sleep during a 77-hour time period.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2005
Resolution: New [name withheld] has reported aboard vessel, and relief process is in progress. Vessel has been moored since 29 March with only 2 short transits to and from Frederiksted.
Fire Fighting › Ventilation Systems
Issued 2 December 2003 Resolved
VENT CASING IN ENGINE ROOM IS WASTED.
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 12 February 2004
Resolution: CLASS (GL) REPORT RECEIVED FOR CORRECTION. CASING SUPPLY DUCT AIR HANDLING UNIT AND 2 PCS ENG ROOM PORT SIDE AFT RENEWED.
Engineering › Shafting/Propeller Arrangements
Issued 19 June 2003 Resolved
Noted that vessel has problems with controlable pitch propeller system. System controls lag, and vessel will not zero pitch at times. Provide ABB Tech Report regarding findings and repairs to the controlable pitch propeller system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2003
Engineering
Issued 19 June 2003 Resolved
Noted that vessel has problems with controlable pitch propeller system. System controls lag, and vessel will not zero pitch at times. Provide Flag Rep. report regarding findings and repairs to the controlable pitch propeller system.
Due 3 July 2003
Resolved 4 July 2003
Resolution: Received report from class attesting satisfactory repairs to CPP system.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 January 2003 Resolved
Make permanent repairs to safety rail on cargo deck forward starboard side. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Recieved class report attesting to repairs of damage.
Construction/Loadline › Penetrations
Issued 27 January 2003 Resolved
Repack pipe and electric penetrations in fuel oil purifier room bulkhead seperating room from machinery spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 28 February 2003
Resolution: Received class report attesting to repairs of damage.
Navigation › Piloting/Steering
Issued 23 July 2002 Resolved
INLAND AND INTERNATIONAL RULES AND TIDAL CURRENT TABLES WERE MISSING AND WERE ORDERED. VESSEL WAS INSTRUCTED TO FAX COPY OF RECIEPT TO MSO JACKSONVILLE WHEN RECIEVED. LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Unknown
Due 23 August 2002
Resolved 23 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 February 2002 Resolved
Turbocharger damaged after an explosion on cylinder No. 6, Provide Class [name withheld] attesting the proper repair of vsl's turbocharger. As per Class reccom. one time voyage was granted from St. Croix, VI to Pt Everglades, FL for class report, report must be completed and provided prior departure. LEGACY COMPONENT DESC: Turbocharger
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 February 2002
Resolved 27 February 2002
Resolution: Received Class report attesting the proper repair of the vessel''s turbocharger.
Navigation
Issued 24 September 2000 Resolved
Master of the SEA CLOUD almost caused the vessel to ground in the Port of St. Thomas.
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Navigation
Issued 24 September 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 September 2000
Resolved 6 June 2001
Documentation
Issued 24 September 2000 Resolved
Document of compliance expired 20SEP00. Provide valid Document.
Condition: Unknown
Due 24 September 2000
Resolved 27 September 2000
Fire Fighting
Issued 19 June 2000 Resolved
Provide evidence of service of fire fighting foam extinguishers.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 19 June 2000 Resolved
Renew emergency diesel fire fighting instructions.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 19 June 2000 Resolved
Provide operating instructions for paint locker (fwd) and post in the vicinity of the controls.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Navigation
Issued 27 January 2000 Resolved
IMPROPER INSTRUCTIONS FOR EMERGENCY STEERING AND POOR DRILL. CORRECT INSTRUCTIONS AND PROVE DRILLS ARE CONDUCTED IN ACCORDANCE WITH 33 CFR PRIORTO 26FEB00.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Navigation
Issued 27 January 2000 Resolved
LIGHT FOR MAGNETIC COMPASS IS INOPERABLE. REPAIR OR RENEW PRIOR TO 26FEB00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Navigation
Issued 9 June 1999 Resolved
VESSEL HAS NO PERMANENT RECORDING CAPABILITY FOR ITS ECHO DEPTH SOUNDING DEVICE. PROVIDE VESSEL WITH A PERMANENT RECORDING CAPABILITY PRIOR TO 09 JULY 1999.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999

Ownership record