Records from 1997 to 2012. Most recent: inspection, 15 May 2012.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 29.0 ft × 3.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHAW BOATS INC · HOQUIAM WA · built 1997
Hull materialFRP (Fiberglass)
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portZEPHYR COVE, NV
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
15 May 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4382868
22 July 2011
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4097699
6 July 2011
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4085869
10 April 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3450034
10 June 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3228026
29 April 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3207499
30 May 2007
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2991705
19 March 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2889113
9 June 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2675199
10 May 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639865
5 July 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2415933
5 May 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2355239
8 April 2004
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2040370
21 May 2003
Annual Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779736
20 November 2002
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1712192
29 April 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1610571
15 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075590
10 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362341
28 July 2000
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1425036
28 June 2000
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413772
13 September 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429218
16 September 1998
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 799689
20 May 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 803725
30 July 1997
Hull Examination · Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1406331
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 15 May 2012
Resolved
Replace STBD MDE exhaust Hose.
Condition: Improper/Lack of Maintenance
Due 15 June 2012
Resolved 22 May 2012
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 21 August 2011
Resolved 27 October 2011
Resolution: DER faxed a copy of the EAP training roster.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 18 August 2011
Resolution: DER faxed copy of MIS report.
Construction/Loadline › Structures › Superstructure
Issued 6 July 2011
Resolved
Provide rigging survey for all standing rigging by professional rigging surveyor and submit report to USCG Sector San Francisco by 22 Jul 2011.
Due 22 July 2011
Resolved 13 July 2011
Construction/Loadline › Structures › Superstructure
Issued 6 July 2011
Resolved
Replace the thru bolt with a longer bolt to fully engage the locknut.
Due 22 August 2011
Resolved 18 August 2011
Construction/Loadline › Structures › Superstructure
Issued 6 July 2011
Resolved
Replace strap toggle, in kind, adding washers between the toogle straps on both sides of the chainplate to center the toggle and prevent the angled position.
Due 22 August 2011
Resolved 18 August 2011
Engineering › Fuel Oil Service System › Hose
Issued 10 April 2009
Resolved
Properly repair/replace cracked fuel hose stbd engine.
Due 13 April 2009
Resolved 13 April 2009
Electrical › Electric Supply System (service) › Cable
Issued 10 April 2009
Resolved
Replace twist-on electrical type connectors for sewage system macerator pump.
Due 13 April 2009
Resolved 13 April 2009
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 June 2008
Resolved
Renew retro-reflective material on identified lifefloat IAW 46 CFR 160.010-4 (p)
Due 10 June 2008
Resolved 10 June 2008
Lifesaving › Lifefloat › Serviceable
Issued 10 June 2008
Resolved
Make repairs to port life float to fix splits in the foam floatation material.
Due 30 June 2008
Resolved 10 June 2008
Lifesaving › Lifefloat › Float-free Link
Issued 10 May 2006
Resolved
Renew lifefloat weak link as required by 46 CFR 180.137 and NVIC 8-83.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 9 June 2006
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 5 May 2005
Resolved
Remove 2 children type II PFD from the child type I PFD storage.
Due 5 July 2005
Resolved 5 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 May 2005
Resolved
Label the amount of Adult PFDs in the storage compartment in way of the port window.
Due 5 July 2005
Resolved 5 May 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 May 2005
Resolved
Properly separate adult and children PFDs.
Due 5 July 2005
Resolved 5 May 2005
Engineering › Bilge Water Management System › Valve
Issued 5 May 2005
Resolved
Install a metallic positive shutoff valve near the thru hull penetration for each electric bilge pump overboard IAW 46CFR182.150(c)(7)
Due 5 July 2005
Resolved 5 July 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 May 2005
Resolved
Renew the waterlight battery for the lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2005
Resolved 5 May 2005
Documentation › Certificates/Documents › Stability Letter
Issued 5 May 2005
Resolved
Post the stability letter.
Due 5 July 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2005
Resolved
Renew the eye wash.
Due 5 July 2005
Resolved 5 May 2005
Electrical › Electrical Distribution System (service)
Issued 8 April 2004
Resolved
Properly dead end un-used cable located in aft hull support strut, near power inverter as indicated by attending marine inspector. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Resolved 20 April 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 April 2002
Resolved
RENEW LIFELINE WITH MATERIAL THAT IS BOUYANT, RENEW GRAB STRAPS
Due 29 April 2002
Resolved 29 April 2002
Resolution: GRAB STRAPS AND BOUYANT LINE RENEWED.
Lifesaving › Hand Flares › Storage
Issued 29 April 2002
Resolved
LABEL FLARE BOX LOCATION.
Due 29 April 2002
Resolved 29 April 2002
Resolution: LOCATION OF FLARE BOX LABELED.
Documentation
Issued 28 June 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Documentation
Issued 30 July 1997
Resolved
SUBMIT FOR APPROVAL REVISED 12 VOLT ELECTRICAL DRAWINGS WHICH ADDRESS THE COMMENTS OF MSO PORTLAND'S LETTER DATED JULY 18, 1997.
Condition: Unknown
Due 15 August 1997
Resolved 28 May 1998
Documentation
Issued 30 July 1997
Resolved
PROVIDE A COMPLETE SET OF AS BUILT STRUCTURAL DRAWINGS THAT HAVE BEEN REVIEWED AND APPROVED BY THE U.S. COAST GUARD MARINE SAFETY CENTER (MSC) AND SATISFACTORILY ADDRESS ANY COMMENTS GENERATED DURING THE MSC PLAN REVIEW.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997