MAURY USCG vessel records
← All vessels

ELDORADO

Built
1967
Last inspected
8 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK7971
Flag
UNITED STATES
Maury page id
psix-45590

Documentation record

Registered dimensions (L × B × D)79.5 ft × 21.1 ft × 8.0 ft
Registered tonnagegross 88 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA BOAT COMPANY · COSTA MESA, CA, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
68 - Displacement, Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 38 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 38

8 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8070660
15 January 2025 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7917432
29 November 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8023531
23 April 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7870381
30 November 2023 In-Service Inspection · Administrative Inspection · Special Consideration
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7831993
18 August 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7769050
11 April 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655838
23 February 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640901
23 February 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640920
14 February 2023 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7568195
10 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7568193
14 October 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7576843
23 June 2022 Administrative Inspection · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485407
6 April 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403996
13 March 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411456
11 March 2022 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7418134
21 November 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7353174
15 September 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7308733
18 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7201333
9 February 2021 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7166582
14 January 2021 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7134711
19 August 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7037542
21 May 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7078745
27 April 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6944790
10 December 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6872638
21 October 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6825129
25 April 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6683499
27 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6624425
15 January 2019 Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6598119
21 February 2018 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350789
27 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6313302
3 July 2017 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6182375
4 April 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104195
11 January 2017 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6015942
2 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6054892
6 October 2016 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6007938
1 July 2016 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5915871
11 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5833109

Deficiency record · 24

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 January 2023 Resolved
An internal structural examination consists of a complete examination of the vessels main strength members including the major internal framing. Treat/repair areas of wood decay in fwd engine room on PORT side fwd of fuel tank as indicated by MI. 46CFR176.610(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2023
Resolved 14 February 2023
Resolution: MI verified that the wood decay has been scarfed and treated; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 6 April 2022 Resolved
Bridge Navigation Watch Alert System (BNWAS) 46 CFR 185.410 Watchmen. (a) The owner, charterer, master, or managing operator of a vessel carrying overnight passengers shall have a suitable number of watchmen patrol throughout the vessel during the nighttime, whether or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation. (b) Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 14 February 2023
Resolution: Vessel has submitted plans for watch alerter system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 March 2022 Resolved
Electrical equipment on a vessel msut be installed and maintained to protect passengers, crew, otherpersons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Inspector found that electrical outlets within the passenger berthing areas are ungrounded.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2022
Resolved 6 April 2022
Resolution: def cleared
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2021 Resolved
A self priming, power driven fire pump must be installed on each vessel, vessel has Inop fire pump
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Tested sat, Def cleared
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 January 2021 Resolved
Identified gate valve for bait tank in aft engine room unserviceable. Issued 835 worklist to replace valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2021
Resolved 21 February 2021
Resolution: Master Replaced valve with new in kind.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2019 Resolved
Overcurrent protection shall be provided for each conductor for the purpose of opening circuit if a current value will cause excessive/dangerous temperature breaker. #22 in aft ER panel is 20 amp with 14 awg conductor. Breaker shall remain open until replaced with 15 amp breaker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 December 2019
Resolution: Breaker replaced with 15 amp.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 October 2019 Resolved
All mattresses must comply with FF4-72.16 standard for mattress flammability or IMO Res A.688(17). Current mattresses are custom made by boat outfitter with vinyl covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 12 March 2022
Resolution: Operator installed mattresses compliant with Title 16 CFR Part 1633.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2019 Resolved
Prove proper operation of the port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2019
Resolution: vessel proved proper operation of the port MDE.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2018 Resolved
Anchor light not functional. Rectify prior to night ops.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 12 March 2018
Fire Fighting › Fire Pumps › Arrangement
Issued 21 February 2018 Resolved
Gauge on fire pump not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 12 March 2018
Lifesaving › Lifefloat › Painter
Issued 21 February 2018 Resolved
Lifefloat painter not attached to vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 21 February 2018
Resolution: Deficiency corrected on the spot to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 February 2018 Resolved
Lifelines on 02 lifebuoys wasted and in need of replacement. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2018
Resolved 21 February 2018
Resolution: Corrected on the spot to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 April 2017 Resolved
Vessel did not have a deviation table
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 19 April 2017
Resolution: Deviation table provided
Communications › Alarms/Indicators › Fire Alarm
Issued 4 April 2017 Resolved
Berthing did not have smoke detectors
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 19 April 2017
Resolution: Smoke detector provided
Communications › Visual Communication › Red Warning Signal
Issued 4 April 2017 Resolved
vessel did not have pax capacity placard for upper deck
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 19 April 2017
Resolution: Placard provided
Construction/Loadline › Structures › Superstructure
Issued 11 January 2017 Resolved
Crop and renew engine room port side aft of fuel tank frame (shelf).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Crew cropped and renewed rotted area.
Construction/Loadline › Structures › Superstructure
Issued 11 January 2017 Resolved
Crop and renew engine room stbd aft of fuel tank overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Crew cropped and renewed rotted area.
Construction/Loadline › Structures › Superstructure
Issued 11 January 2017 Resolved
Scrape and treat engine room stbd side aft of fuel tank overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Crew treated indicated area in engine room.
Construction/Loadline › Structures › Superstructure
Issued 11 January 2017 Resolved
Scrape and treat engine room main header beam port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Crew scraped and treated area on engine room beam.
Construction/Loadline › Hull › Side Shell
Issued 11 January 2017 Resolved
Replace fasteners as indicated in Laz.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Crew replaced all corroded/broken fasteners in laz.
Construction/Loadline › Hull › Stiffener
Issued 11 January 2017 Resolved
Replace 03 stanchions in forepeak. Replace in kind (steel).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: New stanchions were replaced in forepeak space.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2017 Resolved
Repair most forward stanchion on portside upper deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Upperdeck port side stanchion was cropped and renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2017 Resolved
Secure stanchions on port side upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Upperdeck port side stanchions were all re-fastened and secured properlly.
Construction/Loadline › Hull › Side Shell
Issued 11 January 2017 Resolved
Repair starboard side hole from old generator overboard discharge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 22 February 2017
Resolution: Overboard discharge was repaired using a graving block.

Ownership record