QUAIAPEN is a 1967 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1984, most recently in April 2026, along with 81 deficiencies.

Records from 1984 to 2026. Most recent: inspection, 16 April 2026.

Built
1967
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCB6470
Flag
UNITED STATES
367373790
Maury page id
psix-45591

Inspections, by type

…with no type recorded2
Years with a record 36 calendar years (1984–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.7 ft × 20.3 ft × 7.5 ft
Registered tonnagegross 87 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WARREN, RI, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Simplified, Gross Ton
64 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCB6470MMSI 367373790 · active · compulsorily equipped · granted 15 August 2018, expires 1 November 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 60

16 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8356834
18 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8237374
16 September 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8002000
9 April 2024 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7892236
19 September 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7793620
24 April 2023 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7683940
16 June 2022 Re-Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7458960
8 April 2022 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7426639
22 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7313129
29 September 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7067731
18 September 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7060727
9 June 2020 Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6972211
18 September 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6809215
12 September 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6496652
24 May 2018 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6403526
27 June 2017 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6177849
12 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6173865
23 August 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5980532
29 April 2016 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5865300
3 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5826035
19 August 2015 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5220617
19 August 2014 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4958286
29 May 2014 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4872955
23 May 2012 Hull Examination · Internal Structural Exam · Examination of Repairs · MTSA Verification · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4320069
12 May 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3472940
28 April 2008 Deficiency Check · COI Inspection · Examination of Repairs · MTSA Verification
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3192291
14 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2961701
13 June 2007 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2965625
18 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2910892
12 July 2005 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2422658
29 June 2005 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2407350
20 July 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2139768
19 July 2004 MTSA Verification · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2135591
18 February 2004 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2008337
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972324
1 May 2003 Hull Examination · MARPOL Annex V Examination · Internal Structural Exam · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1779728
10 January 2002 Examination of Repairs · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1478355
20 March 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1432458
5 February 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1057882
3 October 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450532
23 September 1999 Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1438904
21 January 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 787153
23 September 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801857
20 October 1997 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 778155
28 February 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1097531
27 September 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1141421
25 May 1996 Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192409
3 May 1995 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879227
30 September 1993 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840140
11 June 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946170
24 September 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250731
24 May 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939599
12 March 1990 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241649
28 March 1989 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345435
9 March 1988 Hull Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194763
10 December 1986 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013152
10 December 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027867
8 May 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297963
28 April 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297959
2 November 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286886

Deficiency record · 81

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2024 Resolved
During annual inspection it was discovered the vessels MDE had blown a piston and had been out of service approx two weeks. Issued requirement to repair/replace STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2024
Resolved 15 May 2025
Resolution: New MDE installed. Sea trials conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 16 September 2024 Resolved
Two windows that are being used to facilitate cargo are written on the emergency safety plan as emergency exits, but labeled as such on board. Issued requirement to label emergency egress.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2024
Resolved 15 May 2025
Resolution: Labelled emergency exits.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 September 2021 Resolved
Painter line to BA no longer servicable, issued CG-835 to recitify deficiency within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 24 September 2021
Resolution: Received attestment from O/O that painter line to BA's had been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 September 2021 Resolved
A wire from the battery box to navigation station was frayed in the pilothouse. Issued CG-835 to rectify deficiency. The wire was found to go to a gauge that was removed and the wire was deadened. Vsl rep removed frayed wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 22 September 2021
Resolution: Vsl rep removed frayed wire.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 24 September 2020 Resolved
Update the vessel's fire control plan to accurately reflect equipment on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 25 September 2020
Resolution: MI attended vessel and witnessed correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2020 Resolved
Remove non-permanent type connections (wing-nuts) on batteries below the pilot house/ in the forward portion of the passenger compartment.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 25 September 2020
Resolution: MI attended vessel and witnessed correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2020 Resolved
Configure battery compartment cover in the forward passenger compartment with a securing latch to deter passengers from access.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 25 September 2020
Resolution: MI attended vessel and cleared requirement
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2020 Resolved
Prove proper operation of the bilge suction prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2020
Resolved 25 September 2020
Resolution: MI attended vessel and witnessed correction
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 September 2020 Resolved
Provide copy of consortium MIS report for 2020 random testing
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2020
Resolved 25 September 2020
Resolution: MI recieved a copy of the MIS form
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 September 2019 Resolved
Cracked welds found on framing in Lazzerette, make repairs at upcoming dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 January 2020
Resolved 29 September 2020
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 18 September 2019 Resolved
Found that the posted Emergency Procedures was incorrect
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 4 November 2019
Resolution: O/O provide proof of correction to emergency proceedures.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 June 2017 Resolved
Complete MOB and Fire Drills with USCG MI in attendance, prior to carrying passengers. 46CFR185.520
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 28 June 2017
Resolution: Completed at Davis Park Ferry Terminal with USCG MI in attendance.
Engineering › Bilge Water Management System › Not Operational
Issued 27 June 2017 Resolved
Prove proper operation of bilge system prior to carrying passengers. 46CFR182.25-10(a)&(b) [Old T]
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 27 June 2017
Resolution: Completed on the spot after checking line. (too much air in the system initially)
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 June 2017 Resolved
Label electrical panel @ operating station. 46CFR183.220(d)
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 17 August 2017
Resolution: labeled
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2017 Resolved
Provide double hose clamps where possible on flex hose in engine room. 46CFR182.410(d)
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 17 August 2017
Resolution: provided
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 August 2016 Resolved
Stern light inoperable, repair stern light
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 23 September 2016
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Keel
Issued 29 April 2016 Resolved
Submit repair proposal for hole in keel (2nd compt from aft) and repair prior to credit dry dock.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 6 May 2016
Resolution: MI attended vessel and witnessed satisfactory repair.
Construction/Loadline › Hull › Hull Plating
Issued 29 April 2016 Resolved
Submit repair proposal for hole in midships stern, and repair prior to credit drydock.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 6 May 2016
Resolution: MI attended vessel and witnessed satisfactory repair.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 April 2016 Resolved
Repair cracked weld in ladder rung in 2nd compt from fwd.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 6 May 2016
Resolution: MI attended vessel and witnessed satisfactory repair.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 August 2015 Resolved
Repair Starboard running light (DIM)
Condition: Placed in Improper Service
Due 19 August 2015
Resolved 19 August 2015
Resolution: Corrected on the spot.
Engineering › Bilge Water Management System › Manifold
Issued 19 August 2015 Resolved
Label bilge manifold.
Condition: Placed in Improper Service
Due 19 August 2015
Resolved 19 August 2015
Resolution: Corrected on the spot
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 August 2015 Resolved
Relabel ring bouy
Condition: Placed in Improper Service
Due 19 August 2015
Resolved 19 August 2015
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 August 2015 Resolved
Clean and replace retro reflective tape as required. L/J's were extreamly dirty and retro on several jackets was reaching the end of its servicable life.
Condition: Improper/Lack of Maintenance
Due 1 September 2015
Resolved 1 September 2015
Resolution: MI attended vessel and cleared requirement.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 August 2014 Resolved
Provide a copy of the current Coast Pilor for area of operation. 46CFR121.420
Due 2 September 2014
Resolved 11 September 2014
Resolution: MI attended vessel and noted item had been corrected.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 August 2014 Resolved
Provide a copy of the tidal current tables for area of operation. 46 CFR 121.420
Due 2 September 2014
Resolved 11 September 2014
Resolution: MI attended vessel and noted item had been corrected.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 19 August 2014 Resolved
Provide emergency broadcast placard at operating station. 46 CFR 121.506
Due 2 September 2014
Resolved 11 September 2014
Resolution: MI attended vessel and noted item had been corrected.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 19 August 2014 Resolved
Post Emergency Instruction list near operating station. 46 CFR 122.510
Due 2 September 2014
Resolved 11 September 2014
Resolution: MI attended vessel and noted item had been corrected.
Construction/Loadline › Hull › Side Shell
Issued 29 May 2014 Resolved
Crop and renew steel at transom on STB side aprox 12 inches from bottom hull plating.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Area in question was cropped out and renewed in kind.
Construction/Loadline › Hull › Transverse Frame
Issued 29 May 2014 Resolved
Crop and renew transverse from on STB side IVO rudder post on transom. Frame is wasted.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Area cropped and renewed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 29 May 2014 Resolved
Prepare #2 and #6 voids for inspection. Remove excess oil from compartments and make internals available for inspection.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Compartments were cleaned and inspected by CIV GL.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 May 2014 Resolved
Crop and renew port side engine compartment #4 and #5 frames from keel. Frames were found to be wasted.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Frames cropped and renewed.
Stability › Watertight Integrity › General
Issued 29 May 2014 Resolved
Remove fiberglass repair on port side fwd engine room bulkhead; Crop and renew port side fwd engine room bulkhead. Bulkhead extending several frames was found to be wasted.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Area was cropped and renewed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 May 2014 Resolved
Crop and renew STB side longitudinal frames in void fwd of engine room. Frames wasted #1 and #2 from keel.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Frames cropped and renewed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 May 2014 Resolved
Crop and renew wasted frames in compartment fwd of engine room. #4 longitudinal frame found wasted.
Action required: 705 - Other - as specified
Resolved 13 June 2014
Resolution: Frame cropped and renewed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 May 2012 Resolved
Main deck seating is worn. Supports are fractured & wasted.
Action required: 705 - Other - as specified
Resolved 24 May 2012
Accommodation/Occupational Safety › Ventilation › General
Issued 12 April 2012 Resolved
Renew stbd vent for machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 May 2012
Resolution: vent cowl renewed.
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2009 Resolved
Provide FCC documents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 14 May 2009
Resolution: Fax copies provided
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 April 2008 Resolved
Renew worn & missing retro reflective tape on ten adult PFDs. Total passengers reduced by 21 for PFDs.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 14 May 2008
Resolution: Completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2008 Resolved
Renew 11 Adult PFDs. (Note: 1 child and 22 adult failed. 27 child and 232 adult found satisfactory aboard.) Total persons allowed reduced to 232 until defective PFDs replaced to match numbers required on COI. All PFDs aboard require cleaning. They are dust & soot covered from vessel being in lay-up at yard.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 14 May 2008
Resolution: Completed.
Fire Fighting › Fire Pumps › Suction Valve
Issued 28 April 2008 Resolved
Note: Not Suction valve. Clean discharge control valve for combination fire & bilge pump. Prove operation of fire pump, fire main, hoses and nozzles.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 14 May 2008
Resolution: Completed. Frozen valve freed, cleaned and lubricated.
Engineering › Sea-water System (primary cooling) › Pump
Issued 28 April 2008 Resolved
Reinstall pump impeller and prove proper operation of MDE cooling system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 14 May 2008
Resolution: Completed. Engine cooling tested and found satisfactory
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 April 2008 Resolved
Mark draft on vessel so that the restrictions of draft for max load as presented in the stability letter are easily verified by the vessel's master.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 16 May 2008
Resolution: Completed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 April 2008 Resolved
Insure a Lifejacket Instruction Placard for each different style of Lifejacket is posted on the vessel where passengers & crew can readily see.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2008
Resolved 14 May 2008
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 June 2007 Resolved
Repair wiring conduit on port side of passenger accommodations between E/R and fwd bhd IWO side shell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 16 May 2008
Resolution: Completed. Conduit pipe split and fitted in place IWP wasted conduit around wiring and secured.
Construction/Loadline › Hull › Bottom Plating
Issued 18 June 2007 Resolved
C & R stbd top section of bow plane where holed.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 19 June 2007
Resolution: Approximately 7" round spigot insert fitted.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 June 2007 Resolved
Repair middle step from pilothouse to passenger accommodations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 16 May 2008
Resolution: Completed.
Construction/Loadline › Hull › Stiffener
Issued 18 June 2007 Resolved
C & R wasted bottom longs in lazarett as follows; # 2 stbd, # 2, 3, & 5 port.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 28 June 2007
Construction/Loadline › Hull › Stiffener
Issued 18 June 2007 Resolved
C & R wasted transom stiffener stbd of centerline between #1 & 2 vertical frames.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 28 June 2007
Construction/Loadline › Hull › Side Shell
Issued 18 June 2007 Resolved
C & R bulwarks at bow.
Condition: Improper/Lack of Maintenance
Due 28 September 2007
Resolved 16 May 2008
Resolution: Wasted fashion plate removed and railing sections renewed.
Construction/Loadline › Structures › Scuttle
Issued 18 June 2007 Resolved
Renew hatch rings for the aft three hatches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2007
Resolved 28 April 2008
Resolution: Completed.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 18 June 2007 Resolved
Clean all sea valves & spool pieces // recoat internals of seachests with paint. Renew strainer for fire pump sea suction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 19 June 2007
Resolution: Corrected.
Construction/Loadline › Structures › Scuttle
Issued 18 June 2007 Resolved
Grease all hatch dogs.
Condition: Improper/Lack of Maintenance
Due 30 June 2007
Resolved 28 June 2007
Fire Fighting › Fire Main › Valves
Issued 12 July 2005 Resolved
Repair or replace valve handle on fire station located on upper deck, port side.
Due 20 August 2005
Resolved 1 August 2005
Resolution: Cleared over the phone, had valve on scene and started work prior to inspectors leaving.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 July 2005 Resolved
Vsl restricted to 214 total persons until life jacket count is as per requirements of COI are met.
Due 20 July 2005
Resolved 20 July 2005
Resolution: Marked and vsl in compliance with COI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 1 May 2003 Resolved
Provide secure mountings for portable fire extinguishers.
Due 1 May 2003
Resolved 28 May 2003
Electrical
Issued 1 May 2003 Resolved
Secure batteries, battery covers and hardwire the charger.
Due 1 May 2003
Resolved 28 May 2003
Operations/Management
Issued 1 May 2003 Resolved
Update emergency procedures for man overboard, fire , etc.
Due 1 May 2003
Resolved 28 May 2003
Construction/Loadline
Issued 1 May 2003 Resolved
Repair handrails on the starboard embarkation ladder.
Due 1 May 2003
Resolved 28 May 2003
Construction/Loadline
Issued 1 May 2003 Resolved
Repair/renew starboard shaft log or submit proposal.
Due 30 September 2003
Resolved 28 May 2003
Construction/Loadline
Issued 1 May 2003 Resolved
The starboard shaft log is wasted, temporary repair made. Shaft log to be cut and repaired in kind to the satisfaction of attending marine inspector.
Due 30 November 2003
Resolved 12 February 2004
Electrical › Electrical Distribution System (service)
Issued 10 January 2002 Resolved
Renew worn wiring in pilot house electrical distribution system. LEGACY COMPONENT DESC: Conductor
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2002
Resolved 24 May 2002
Communications › Internal Communications System
Issued 10 January 2002 Resolved
Prove proper operation of vessels alarms controls & comms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2002
Resolved 24 May 2002
Navigation
Issued 3 October 2000 Resolved
STEERING RAM LEAKING. REPAIR/RENEW.
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Construction/Loadline
Issued 3 October 2000 Resolved
NO BILGE HIGH LEVEL ALARM IN ENGINE ROO AND LAZARRETT. INSTALL
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Construction/Loadline
Issued 3 October 2000 Resolved
PIPE PENETRATIONS NOT WATER TIGHT. REPAIR/RENEW
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Navigation
Issued 3 October 2000 Resolved
ANCHOR LIGHT & COMPASS LIGHT INOPERABLE. REPAIR/RENEW. VESSEL RESTRICTED TODAYLIGHT OPS.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Fire Fighting
Issued 3 October 2000 Resolved
PIN HOLE IN ELBOW FOR FIRE/BILGE PUMP DISCHARGE. REPAIR/RENEW.
Condition: Unknown
Due 19 October 2000
Resolved 19 October 2000
Lifesaving
Issued 23 September 1999 Resolved
RENEW OR REPAIR AS NEEDED THE 115 ADULT AND 13 CHILD PFDS. VESSEL RESTRICTED TO 139 ADULT AND 13 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 24 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1999 Resolved
LABEL CAPACITY AND VESSEL NAME ON ALL 3 B/As.
Condition: Unknown
Due 24 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1999 Resolved
INSTALL 2 ADDITIONAL STRIPS OF RETRO REFLECTIVE TAPE ON THE ONE B/A MISSINGIT.
Condition: Unknown
Due 24 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1998 Resolved
REPLACE 23 ADULT PFD'S AND 1 CHILD. RENEW REFLECTIVE TAPE ON 11 ADULT AND 3 CHILDREN.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Engineering
Issued 23 September 1998 Resolved
REPAIR EXHAUST PIPE LEAK ON SMDE.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Unknown
Issued 23 September 1998 Resolved
REPAIR FRACTURE IN AFT PORT GANGWAY.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Fire Fighting
Issued 23 September 1998 Resolved
MISSING TAMPER SEAL FOR BII CO2 EXTINGUISHER.
Condition: Unknown
Due 4 December 1998
Resolved 4 December 1998
Lifesaving
Issued 20 October 1997 Resolved
REMARK VESSEL'S NAME AND NUMBER OF PERSONS ON BUOYANT APPARATI.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Fire Fighting
Issued 20 October 1997 Resolved
PROVIDE AN HAND OPERATED FIRE & BILGE PUMP. (NOTE: A SECOND POWER DRIVEN PUMP MAY BE SUBSTITUTED FOR THE HAND PUMP & 3 FIRE BUCKETS MAY BE SUBSTITUTED FOR THE HAND FIRE PUMP.) VESSEL MAY NOT CARRY PASSENGERS UNTILTHIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Documentation
Issued 20 October 1997 Resolved
PROVIDE A VALID FCC CERTIFICATE. VESSEL MAY NOT OPERATE BEYOND 1000' FROM SHORE UNTIL CERT. IS PROVIDED. (COPY MAY BE FAXED TO CG OFFICE AT 732- 1636.)
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Fire Fighting
Issued 20 October 1997 Resolved
SERVICE 1 B-II FIRE EXTINGUISHER. VESSEL NOT TO BE OPERATED UNTIL ALL REQUIRED FIRE EXTINGUISHERS ARE ABOARD.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 20 October 1997 Resolved
REPLACE RING BUOYS. (NOTE YOU HAVE 2 ABOARD. ONLY 1 IS REQUIRED. IFD YOU ONLY PUT 1 BACK ABOARD INSURE THAT IT IS FITTED W/ 60' OF LINE & THE WATER LIGHT IS SECURED W/ A 3'-6' LANYARD FITTED W/ A SNAP CLIP TO ALLOW QUICK REMOVAL OR ATTATCHMENT.) MUST BE ABOARD PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 20 October 1997 Resolved
REPLACE ALL DEFECTIVE PFDS. (APPROX 70 ADULT AND 6 CHILD) RENEW WORN REFECTOR TAPE AS NEEDED. (APPROX 38) INSURE 253 ADULT AND 26 CHILD PFDS AREABOARD VESSEL PRIOR TO SAILING W/ PASSENGERS.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 9 March 1988 Resolved
PROVIDE FIVE ADULT PFD'S.
Condition: Unknown
Due 9 March 1988
Resolved 9 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.