MAURY USCG vessel records
← All vessels

USNS SISLER

USNS SISLER is a 1997 freight ship. The Coast Guard has recorded 46 inspections since 2016, most recently in June 2026, along with 31 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 14 June 2026.

Built
1997
Last inspected
14 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 June 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9117038
455911
Flag
UNITED STATES
Maury page id
psix-455911

Documentation record

Tonnage as PSIX records it26287 - Dead Weight, Ton
72718 - Convention (Subpart B), Gross Ton
26287 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RALPH E POMEROY Freight Ship · MISLE 492326 · 15 February 2024 · activity 7869047

Inspection history · 46

14 June 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8404716
19 February 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312858
17 February 2026 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8311274
22 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8286238
29 November 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8277255
20 July 2025 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8190538
11 June 2025 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8156857
5 December 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8043478
4 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042951
29 October 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8026190
18 July 2024 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7958266
15 February 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7869047
4 September 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7784788
28 July 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7757917
14 July 2023 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7743051
23 June 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798092
22 June 2023 ACP COI Oversight · Re-Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7720092
30 December 2022 ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7614449
8 December 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7605121
15 July 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7507317
13 May 2022 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7449952
1 February 2022 Type not recorded
No type recorded · Activities Europe · Activity 7393270
27 January 2022 Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7386402
20 October 2021 Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7336097
23 September 2021 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7318573
12 July 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7253120
11 May 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7194012
31 March 2021 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7166618
22 February 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7143902
21 January 2021 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7127872
2 November 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7088208
22 October 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7082106
12 June 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6974501
4 October 2019 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6828352
21 August 2019 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6790202
14 August 2019 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6783553
14 August 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6790197
6 August 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6774394
30 April 2019 ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6673180
5 April 2019 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6659050
21 August 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6487699
4 July 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685321
27 February 2018 Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6347513
27 June 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6143532
30 March 2017 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6114131
7 June 2016 ACP Annual Oversight · Examination of Repairs · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5899712

Deficiency record · 31

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 June 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The ship has a safety policy for crew to clean the laundry dryer lint filters before and after use. The marine inspector observed lint clogging the filters in all three of the crew laundry dryers and additional lint in the exhaust ventilation to the dryers on the 01 deck, port side. The build up of lint and fabric particles creates a fire hazard in the space.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 June 2025 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The marine inspector observed an A-15 door and an additional watertight door open with "hold backs." The two doors separate the Ro-Ro cargo space from the battery storage space on the port side of deck 5C.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2025 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Identified a battery charger plugged into a 110V outlet, located in the secure comms room on the stbd side of deck 5C, that is installed directly under a leaking grey water pipe for the vessel. The electrical outlet and battery charger are not protected against the dripping hazard from above creating an electrical fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 4 August 2025
Resolution: ACS Report showing installation of appropriate enclosure.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 June 2025 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The secure comms room located on the stbd side of 5C deck has an entrance door that is secured with two padlocks and a security bar. The space can only be accessed by one individual on the vessel and no other arrangements are in place to open the door by the crew in the event of an emergency. Remote ventilation shut downs for the space below the secure comms locker are located inside of the secure comms locker space. The crew cannot access the ventilation shut downs without the one individual that has sole access to the space, which delays fire response actions required by the crew in the event of a fire in that space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 December 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Per SOLAS 74 (2020 Cons) Ch III Reg 31.2, cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code. A lifeboat may be accepted as a rescue boat, provided that it and its launching and recovery arrangements also comply with the requirements for a rescue boat. The master reported that the crew members were unable to start the rescue boat engine and received an OEM fault code when attempting to remedy the engine failure. The crew members contacted the rescue boat manufacturer and an OEM representative is required to attend in order to clear the OEM code prior to starting the engine. Furthermore, the lifeboats cannot be used as a rescue boat since the powered winch motors do not comply with the lifting capabilities listed in LSA Code Ch VI Reg 6.1.1.9. Provide an ABS class report attesting to the proper operation of the rescue boat. SOLAS 74 (2020 Cons.) Ch III Reg 20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2024
Resolved 11 December 2024
Resolution: ABS surveyor completed a virtual survey and verified operation of the rescue boat after OEM repairs were made by a technician.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 18 July 2024 Resolved
Every chief engineer officer and second engineer officer on a seagoing ship powered by main propulsion machinery of 3,000 KW propulsion power or more shall hold a STCW certificate of competency. The chief engineer's U.S. merchant mariner credential is not endorsed for chief engineer service (STCW III/2) on board the USNS SISLER. The vessel was previously sailing short by one first assistant engineer as per the minimum manning listed on the Certificate of Inspection. The vessel is now sailing short by one first assistant engineer and one chief engineer and is not in compliance with the minimum manning listed on the Certificate of Inspection. SOLAS 74 as amended, regulation V/14 and STCW 78 as amended, Ch III, Reg III/2
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 27 July 2024
Resolution: Sector IO verified C/E meets III/2 and received confirmation that new 1 A/E reported on board. Vessel is in accordance with manning per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 July 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. As per SOLAS 74 (1997 cons.) Ch. III Reg 41.1.6, each lifeboat shall be of sufficient strength to withstand, when loaded with its full compliment of persons and equipment, a lateral impact against the ship's side at an impact velocity of at least 3.5m/s. The #3 starboard lifeboat FRP shell was found fractured on the port side immediately adjacent to the rubber fender installation, approx 5 ft aft of bow. SOLAS 74 (1997 cons.) Ch. III Reg 19.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: ABS surveyor attended: The fracture was ground out and filled with fiberglass and resin compound, smoothed out, recoated with non-slip coating and considered satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 July 2024 Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to avoid over stressing the falls or davits, unless the motor is designed to prevent such over stressing. The forward magnetic operated limit switch on starboard life boat #3 was found with a mounting bracket that was heavily corroded and positioned the magnet at an angle that will prevent the limit switch from making magnetic contact with the davit. The aft magnetic operated limit switch on starboard life boat #3 was found with an electrical enclosure that was not watertight. The conductors inside of the enclosure were found corroded and may create electrical resistance or failure of the limit switch when energized. SOLAS 74 (1997 cons.) Ch. III Reg 48.2.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Limit switch mounting bracket has been replaced and considered satisfactory to the attending ABS surveyor. Electrical housing was sealed and considered satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 July 2024 Resolved
An emergency alarm system complying with the requirements of regulation 50 shall be provided. The system shall be supplemented by either a public address system or other suitable means of communication. The public address speaker installed at the focsle was not operational when tested by the crew. SOLAS 74 (1997 cons.) Ch. III Reg 2.4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: ABS surveyor attended: Speaker has been repaired, operationally tested and considered satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2024 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks, the minimum fire integrity of bulkheads shall be as prescribed in table 44.1. The galley rolling fire door between the galley and corridor does not close and permits the passage of smoke and flame between the "A" class division. The "A" class fire doors between the galley and corridor were found open with hold back hooks and line. SOLAS 74 (1997 cons.) Ch. II-2 Reg 44
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 28 August 2024
Resolution: The "A" class fire doors between the galley and corridor which were found open with hold back hooks and line have been confirmed to be free of operation as per attending ABS surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 18 July 2024 Resolved
Ventilator openings shall be provided with weather tight closing appliances. The weather tight gaskets for intake 02-101-2 were found both wasted and missing. The ventilator hatch is not weather tight. ICLL 1966 Ch. 1 Reg 19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Weather tight gaskets for intake 02-101-2 which were found not weathertight have been replaced and proven weathertight to the satisfaction of the attending Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2024 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame retarding and, where necessary, fire resisting properties of the cable. The grounding conductor for the #4 winch located at the focsle was found disconnected and missing the thermoplastic around the conductor at the termination. SOLAS 74 (1997 cons.) Ch. II-I Reg 45.5.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Grounding conductor has been replaced and considered satisfactory to the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. MI identified external lube oil filtering devices which are in use for steering system pumps; 1A, 1B, 2A, 2B and both stern tube lubrication systems permanently installed without approved plans and using flexible non fire rated hoses and their power source not installed as required. Systems should not be operated in a permanent fashion pending class plan and installation approval. SOLAS 74 (1997 cons.) Ch. II-1 Reg 29.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 14 August 2024
Resolution: The deficiency was accepted as a condition of ABS class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Procedure 2-C-6, Steering Gear Phase Failure Alarm does not work as written in the ABS approved January 10th, 2020 PSTP’s. SOLAS 74 (1997 cons.) Ch. II-1 Reg 46.2 and 46 CFR 61.20-3
Action required: 705 - Other - as specified
Due 18 September 2024
Resolved 14 August 2024
Resolution: The defieciency was accepted as a condition of ABS class.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 18 July 2024 Resolved
Watertight door indicators are to be provided at the control position showing whether the doors are open or closed, and an audible alarm is to be provided at the door closure. Sliding watertight door audible alarms for the engineering operating station and access to the steering gear rooms were not functional when tested. SOLAS 74 (1997 cons.) Ch. II-1 Reg 25-9.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Sliding watertight door audible alarms for the engineering operating station and access to the steering gear rooms have been repaired operationally tested and considered satisfactory to the attending ABS surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 June 2023 Resolved
A food ration totaling not less than 100,000 kj for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. Packing to be hermetically sealed (can) or vacuum packed (flexible package). All lifeboats contained food rations packages that had lost the vacuum. SOLAS III/41.8.12 (1997 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 June 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs: structural fire protection,including fire-resistant divisions, and protection of opening and penetrations in these divisions. Cable penetrations beneath the x band radar and both ECDIS comprimised open. Crew repacked items with approved material but did not have the manufacturer's instruction on how to apply it to the required A60 deck standard. SOLAS II-2/14.2.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 June 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs: structural fire protection,including fire-resistant divisions, and protection of opening and penetrations in these divisions. Stairtower self-closing fire door 3-112-2 and incinerator room self-closing fire door adjacent to galley do not latch closed. SOLAS 74 II-2/14.2.1.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 June 2023 Resolved
The following fire protection spaces shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Found MCT system, on the EDG bulkhead, was compromised with mixed materials, and not IAW manufacturers instruction for A60 penetration. SOLAS 74 II-2/14.2.1.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found installed wiring in the 02 fiddley stack space improperly secured/supported with rope. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Deck drain piping passing through the engineering operating station is holed. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2023 Resolved
Materials readily rendered ineffective by heat shall not be used for fire mains and hydrants unless adequately protected. Material selection for piping and components shall be in accordance with 46CFR56.60 or ASTM F1155. Brass or bronze materials may be used in accordance with these standards. Numerous fire hydrants in the steering gear and engine room spaces have wye gates installed that are constructed out of aluminum. 74SOLAS(97)II-2/4.6.1 U.S. Supplement To ABS Rules For Steel Vessels For Vessels Certificated For International Voyages dated 1 April 2011.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2023 Resolved
Hoses specified in this chapter as “fire hoses” shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Numerous fire hydrants in the steering gear and engine room spaces are missing spanner wrenches. 74SOLAS(97)II-2/4.7.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found extension cords permanently installed in the engine room. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found the ships personnel elevator electrical control panel door open for natural cooling of electrical components, and a portable fan installed on the elevator motor for forced cooling. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023 Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found an electrically powered speaker not properly mounted with its power cord not properly secured in the engine room machinery workshop. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 March 2021 Resolved
Pump in cargo hold OWS has been replaced with a higher rated through put (8 gpm vs 15 gpm). Higher rated overboard water discharge, recorded in ORB. A non-comformity issued for log book entries and pump deficiency. New pump has been ordered
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2021
Resolved 31 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 September 2019 Resolved
There shall be an alternative means consisting of a fixed independently driven emergency pump. The emergency fire pump is leaking excessively from the shaft seal. Make repairs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2019
Resolution: ABS witnessed satisfactory repair operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2019 Resolved
"A" Class divisions shall be capable of preventing passage of smoke and flame for one hour. The incinerator space has three temporary repairs on a HVAC drainage pipe, which affects an Class A-60 fire boundary. Make permanent repairs to piping/insulation and restore fire boundary.
Action required: 705 - Other - as specified
Resolved 24 September 2019
Resolution: The flex hose sections of the HVAC drain piping have been replaced with metallic union fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2019 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements. The rescue boat battery charger cable is not marine grade and is spliced on both ends. Remove unauthorized installation and replace with marine grade cable via a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: The existing battery charging cable was removed. A new, marine grade, cable was installed and secured in a junction box.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2019 Resolved
Doors fitted in boundary bulkheads shall be self closing. Fire Door 7-84.5-2 will not close. Make repairs and prove proper operation.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: The mentioned fire door was repaired and closing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.