Records from 1997 to 2026. Most recent: inspection, 14 June 2026.
Inspection history · 139
14 June 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8404716
19 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8312858
17 February 2026
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8311274
22 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8286238
29 November 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8277255
20 July 2025
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8190538
11 June 2025
Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8156857
5 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8043478
4 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042951
29 October 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8026190
18 July 2024
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7958266
15 February 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7869047
4 September 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7784788
28 July 2023
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7757917
14 July 2023
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7743051
23 June 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798092
22 June 2023
ACP COI Oversight · Re-Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7720092
30 December 2022
ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7614449
8 December 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7605121
15 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7507317
13 May 2022
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7449952
1 February 2022
Type not recorded
No type recorded · Activities Europe · Activity 7393270
27 January 2022
Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7386402
20 October 2021
Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7336097
23 September 2021
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7318573
12 July 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7253120
11 May 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7194012
31 March 2021
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7166618
22 February 2021
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7143902
21 January 2021
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7127872
2 November 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7088208
22 October 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7082106
12 June 2020
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6974501
4 October 2019
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6828352
21 August 2019
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6790202
14 August 2019
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6783553
14 August 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6790197
6 August 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6774394
30 April 2019
ACP Drydock Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6673180
5 April 2019
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6659050
21 August 2018
Annual Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6487699
4 July 2018
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685321
27 February 2018
Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6347513
27 June 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6143532
30 March 2017
Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6114131
7 June 2016
ACP Annual Oversight · Examination of Repairs · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5899712
18 September 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5722736
18 September 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5727504
24 October 2014
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5011213
15 May 2014
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4859936
3 May 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4301044
27 January 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4233167
26 January 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4232821
25 January 2012
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4469507
9 January 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4221558
9 January 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4221994
6 January 2012
COI Inspection · ACP Handover Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4204808
5 December 2011
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4202024
5 July 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4070390
5 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4071793
18 January 2011
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3928080
11 January 2011
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3925507
1 October 2010
In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3861306
13 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3848833
8 September 2010
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4239972
19 December 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3644558
30 December 2008
ACP COI Oversight · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 3366945
3 October 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3338164
23 September 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3330681
15 September 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3325253
15 September 2008
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3325350
27 August 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3310257
3 January 2008
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3124204
20 June 2007
Examination of Repairs · MTSA/ISPS Verification · Internal Structural Exam · Hull Examination · Annual Inspection · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2967817
13 June 2007
Deficiency Check · Drydock Extension
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2960427
17 January 2007
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2857388
15 September 2006
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2779091
25 July 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2790116
8 July 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2708320
12 April 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2622879
20 January 2006
Ballast Water Examination · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2554355
17 January 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2568622
6 January 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2568634
24 September 2005
Type not recorded
No type recorded · Activities Europe · Activity 2592418
7 July 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2418497
23 June 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2404814
26 May 2005
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2361196
18 November 2004
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2265605
12 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2219385
4 October 2004
In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2216685
6 August 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2157801
20 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104857
31 March 2004
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2035400
10 March 2004
Type not recorded
No type recorded · Activities Europe · Activity 2053513
16 January 2004
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2004518
4 January 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1974416
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976318
29 August 2003
Examination of Repairs · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1897685
15 August 2003
Type not recorded
No type recorded · Activities Europe · Activity 1876708
6 August 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1929696
30 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1950416
28 July 2003
Administrative Inspection
Administrative · Activities Europe · Activity 1859145
21 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2017526
28 June 2003
Type not recorded
No type recorded · Activities Europe · Activity 1902243
23 June 2003
Type not recorded
No type recorded · Activities Europe · Activity 1902256
3 May 2003
In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1804382
18 March 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1758305
7 February 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1743625
8 November 2002
Deficiency Check · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1700477
1 August 2002
In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1663693
2 July 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1640534
7 June 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1627729
26 April 2002
Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1609846
15 February 2002
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1491124
10 December 2001
Annual Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1482512
5 November 2001
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1076401
13 March 2001
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1060641
7 March 2001
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362060
4 October 2000
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1055139
4 April 2000
Examination of Repairs · Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361385
20 March 2000
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 79860
29 February 2000
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 39445
2 November 1999
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361570
22 August 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 156157
8 August 1999
Type not recorded
No type recorded · Activities Europe · Activity 189048
24 July 1999
Type not recorded
No type recorded · Activities Europe · Activity 55765
10 June 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1078416
1 June 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 802396
11 May 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1130394
13 April 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1123570
19 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810603
1 February 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 124361
25 January 1999
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397070
10 December 1998
Hull Examination · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1410007
25 September 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 798822
1 July 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1129463
1 April 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 788882
30 September 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1111583
30 June 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 778144
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 June 2025
Resolved
The company should establish procedures to ensure that
the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The ship has a safety policy for crew to clean the laundry dryer lint filters before and after use. The marine inspector observed lint clogging the filters in all three of the crew laundry dryers and additional lint in the exhaust ventilation to the dryers on the 01 deck, port side. The build up of lint and fabric particles creates a fire hazard in the space.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 June 2025
Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The marine inspector observed an A-15 door and an additional watertight door open with "hold backs." The two doors separate the Ro-Ro cargo space from the battery storage space on the port side of deck 5C.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2025
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Identified a battery charger plugged into a 110V outlet, located in the secure comms room on the stbd side of deck 5C, that is installed directly under a leaking grey water pipe for the vessel. The electrical outlet and battery charger are not protected against the dripping hazard from above creating an electrical fire hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 4 August 2025
Resolution: ACS Report showing installation of appropriate enclosure.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 June 2025
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The secure comms room located on the stbd side of 5C deck has an entrance door that is secured with two padlocks and a security bar. The space can only be accessed by one individual on the vessel and no other arrangements are in place to open the door by the crew in the event of an emergency. Remote ventilation shut downs for the space below the secure comms locker are located inside of the secure comms locker space. The crew cannot access the ventilation shut downs without the one individual that has sole access to the space, which delays fire response actions required by the crew in the event of a fire in that space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2025
Resolved 6 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 December 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Per SOLAS 74 (2020 Cons) Ch III Reg 31.2, cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code. A lifeboat may be accepted as a rescue boat, provided that it and its launching and recovery arrangements also comply with the requirements for a rescue boat.
The master reported that the crew members were unable to start the rescue boat engine and received an OEM fault code when attempting to remedy the engine failure. The crew members contacted the rescue boat manufacturer and an OEM representative is required to attend in order to clear the OEM code prior to starting the engine. Furthermore, the lifeboats cannot be used as a rescue boat since the powered winch motors do not comply with the lifting capabilities listed in LSA Code Ch VI Reg 6.1.1.9. Provide an ABS class report attesting to the proper operation of the rescue boat.
SOLAS 74 (2020 Cons.) Ch III Reg 20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2024
Resolved 11 December 2024
Resolution: ABS surveyor completed a virtual survey and verified operation of the rescue boat after OEM repairs were made by a technician.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 18 July 2024
Resolved
Every chief engineer officer and second engineer officer on a seagoing ship powered by main propulsion machinery of 3,000 KW propulsion power or more shall hold a STCW certificate of competency. The chief engineer's U.S. merchant mariner credential is not endorsed for chief engineer service (STCW III/2) on board the USNS SISLER. The vessel was previously sailing short by one first assistant engineer as per the minimum manning listed on the Certificate of Inspection. The vessel is now sailing short by one first assistant engineer and one chief engineer and is not in compliance with the minimum manning listed on the Certificate of Inspection.
SOLAS 74 as amended, regulation V/14 and STCW 78 as amended,
Ch III, Reg III/2
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 27 July 2024
Resolution: Sector IO verified C/E meets III/2 and received confirmation that new 1 A/E reported on board. Vessel is in accordance with manning per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 July 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. As per SOLAS 74 (1997 cons.) Ch. III Reg 41.1.6, each lifeboat shall be of sufficient strength to withstand, when loaded with its full compliment of persons and equipment, a lateral impact against the ship's side at an impact velocity of at least 3.5m/s. The #3 starboard lifeboat FRP shell was found fractured on the port side immediately adjacent to the rubber fender installation, approx 5 ft aft of bow.
SOLAS 74 (1997 cons.) Ch. III Reg 19.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: ABS surveyor attended: The fracture was ground out and filled with fiberglass and resin compound, smoothed out, recoated with non-slip coating and considered satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 July 2024
Resolved
Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to avoid over stressing the falls or davits, unless the motor is designed to prevent such over stressing. The forward magnetic operated limit switch on starboard life boat #3 was found with a mounting bracket that was heavily corroded and positioned the magnet at an angle that will prevent the limit switch from making magnetic contact with the davit. The aft magnetic operated limit switch on starboard life boat #3 was found with an electrical enclosure that was not watertight. The conductors inside of the enclosure were found corroded and may create electrical resistance or failure of the limit switch when energized.
SOLAS 74 (1997 cons.) Ch. III Reg 48.2.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Limit switch mounting bracket has been replaced and considered satisfactory to the attending ABS surveyor. Electrical housing was sealed and considered satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 July 2024
Resolved
An emergency alarm system complying with the requirements of regulation 50 shall be provided. The system shall be supplemented by either a public address system or other suitable means of communication. The public address speaker installed at the focsle was not operational when tested by the crew.
SOLAS 74 (1997 cons.) Ch. III Reg 2.4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: ABS surveyor attended: Speaker has been repaired, operationally tested and considered satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2024
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks, the minimum fire integrity of bulkheads shall be as prescribed in table 44.1. The galley rolling fire door between the galley and corridor does not close and permits the passage of smoke and flame between the "A" class division. The "A" class fire doors between the galley and corridor were found open with hold back hooks and line.
SOLAS 74 (1997 cons.) Ch. II-2 Reg 44
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 28 August 2024
Resolution: The "A" class fire doors between the galley and corridor which were found open with hold back hooks and line have been confirmed to be free of operation as per attending ABS surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 18 July 2024
Resolved
Ventilator openings shall be provided with weather tight closing appliances. The weather tight gaskets for intake 02-101-2 were found both wasted and missing. The ventilator hatch is not weather tight.
ICLL 1966 Ch. 1 Reg 19.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Weather tight gaskets for intake 02-101-2 which were found not weathertight have been replaced and proven weathertight to the satisfaction of the attending Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2024
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame retarding and, where necessary, fire resisting properties of the cable. The grounding conductor for the #4 winch located at the focsle was found disconnected and missing the thermoplastic around the conductor at the termination.
SOLAS 74 (1997 cons.)
Ch. II-I Reg 45.5.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Grounding conductor has been replaced and considered satisfactory to the attending ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024
Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. MI identified external lube oil filtering devices which are in use for steering system pumps; 1A, 1B, 2A, 2B and both stern tube lubrication systems permanently installed without approved plans and using flexible non fire rated hoses and their power source not installed as required. Systems should not be operated in a permanent fashion pending class plan and installation approval.
SOLAS 74 (1997 cons.)
Ch. II-1 Reg 29.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2024
Resolved 14 August 2024
Resolution: The deficiency was accepted as a condition of ABS class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024
Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Procedure 2-C-6, Steering Gear Phase Failure Alarm does not work as written in the ABS approved January 10th, 2020 PSTP’s.
SOLAS 74 (1997 cons.)
Ch. II-1 Reg 46.2
and 46 CFR 61.20-3
Action required: 705 - Other - as specified
Due 18 September 2024
Resolved 14 August 2024
Resolution: The defieciency was accepted as a condition of ABS class.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 18 July 2024
Resolved
Watertight door indicators are to be provided at the control position showing whether the doors are open or closed, and an audible alarm is to be provided at the door closure. Sliding watertight door audible alarms for the engineering operating station and access to the steering gear rooms were not functional when tested.
SOLAS 74 (1997 cons.)
Ch. II-1 Reg 25-9.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 14 August 2024
Resolution: Sliding watertight door audible alarms for the engineering operating station and access to the steering gear rooms have been repaired operationally tested and considered satisfactory to the attending ABS surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 June 2023
Resolved
A food ration totaling not less than 100,000 kj for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. Packing to be hermetically sealed (can) or vacuum packed (flexible package). All lifeboats contained food rations packages that had lost the vacuum.
SOLAS III/41.8.12 (1997 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 June 2023
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs: structural fire protection,including fire-resistant divisions, and protection of opening and penetrations in these divisions. Cable penetrations beneath the x band radar and both ECDIS comprimised open. Crew repacked items with approved material but did not have the manufacturer's instruction on how to apply it to the required A60 deck standard.
SOLAS II-2/14.2.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 June 2023
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if fire occurs: structural fire protection,including fire-resistant divisions, and protection of opening and penetrations in these divisions. Stairtower self-closing fire door 3-112-2 and incinerator room self-closing fire door adjacent to galley do not latch closed.
SOLAS 74 II-2/14.2.1.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 June 2023
Resolved
The following fire protection spaces shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Found MCT system, on the EDG bulkhead, was compromised with mixed materials, and not IAW manufacturers instruction for A60 penetration.
SOLAS 74 II-2/14.2.1.1.1(2020 Edition)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found installed wiring in the 02 fiddley stack space improperly secured/supported with rope.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Deck drain piping passing through the engineering operating station is holed.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2023
Resolved
Materials readily rendered ineffective by heat shall not be used for fire mains and hydrants unless adequately protected. Material selection for piping and components shall be in accordance with 46CFR56.60 or ASTM F1155. Brass or bronze materials may be used in accordance with these standards. Numerous fire hydrants in the steering gear and engine room spaces have wye gates installed that are constructed out of aluminum.
74SOLAS(97)II-2/4.6.1
U.S. Supplement To ABS Rules For Steel Vessels For Vessels Certificated For International Voyages dated 1 April 2011.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2023
Resolved
Hoses specified in this chapter as “fire hoses” shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Numerous fire hydrants in the steering gear and engine room spaces are missing spanner wrenches.
74SOLAS(97)II-2/4.7.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found extension cords permanently installed in the engine room.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found the ships personnel elevator electrical control panel door open for natural cooling of electrical components, and a portable fan installed on the elevator motor for forced cooling.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2023
Resolved
The condition of the ship and its equipment shall be maintained to condition with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found an electrically powered speaker not properly mounted with its power cord not properly secured in the engine room machinery workshop.
74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 25 June 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 March 2021
Resolved
Pump in cargo hold OWS has been replaced with a higher rated through put (8 gpm vs 15 gpm). Higher rated overboard water discharge, recorded in ORB. A non-comformity issued for log book entries and pump deficiency. New pump has been ordered
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2021
Resolved 31 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 September 2019
Resolved
There shall be an alternative means consisting of a fixed independently driven emergency pump. The emergency fire pump is leaking excessively from the shaft seal. Make repairs and prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2019
Resolution: ABS witnessed satisfactory repair operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2019
Resolved
"A" Class divisions shall be capable of preventing passage of smoke and flame for one hour. The incinerator space has three temporary repairs on a HVAC drainage pipe, which affects an Class A-60 fire boundary. Make permanent repairs to piping/insulation and restore fire boundary.
Action required: 705 - Other - as specified
Resolved 24 September 2019
Resolution: The flex hose sections of the HVAC drain piping have been replaced with metallic union fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2019
Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrical requirements. The rescue boat battery charger cable is not marine grade and is spliced on both ends. Remove unauthorized installation and replace with marine grade cable via a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: The existing battery charging cable was removed. A new, marine grade, cable was installed and secured in a junction box.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2019
Resolved
Doors fitted in boundary bulkheads shall be self closing. Fire Door 7-84.5-2 will not close. Make repairs and prove proper operation.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: The mentioned fire door was repaired and closing.
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 May 2014
Resolved
Annual svc extended for new operating company which took over the vsl with 1 week left on the service window.
Due 14 July 2014
Resolved 5 November 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 January 2012
Resolved
Provide all serviced CO2 extinguishers, mounted in position.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2012
Resolved 9 January 2012
Resolution: Witnessed proper placement of CO2 extinguishers.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 January 2012
Resolved
Provide updated fire control plan & place in fire control plan tubes
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2012
Resolved 3 May 2012
Resolution: Provided snapshot of Fire Control Plan showing ABS stamp "ABS approved on behalf of CG under NVIC 2-95"
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 January 2012
Resolved
Prove proper launching, operation, and recovery of rescue boat
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2012
Resolved 9 January 2012
Resolution: Witnessed satisfactory launching, operation and recovery of rescue boat.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 6 January 2012
Resolved
Provide proper documentation from Norsafe, which proves engine model Steyr M0114 K33 has been approved for use in the Midget 530 MK I / MK II SOLAS rigid rescue boat. Provide documents to Sector Hampton Roads
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2012
Resolved 26 January 2012
Resolution: Provided documentation of accepted rescue boat engines.
Lifesaving › Launching Appliances › Padeye
Issued 5 July 2011
Resolved
Vessel limited to 100 persons prior to repair of STBD MES bowsing wire securing padeye. Make repair IAW manufacturer recommendation and to the satisfaction of USCG Marine Inspector.
Due 31 October 2011
Resolved 21 October 2011
Resolution: Attendending Marine Inspector witnessed satisfactory repairs to padeye.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 May 2011
Resolved
Make life jackets readily available and plainly indicated in new berthing located on 03 adn 04 decks. Per Solas 74/78 III/7.2
Due 27 June 2011
Resolved 14 June 2011
Resolution: Life jackets and immersion suits were made available for inspection; all sat.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 27 May 2011
Resolved
Properly stow life rafts on starboard side helo deck to allow for unobstructed launching.
Due 27 June 2011
Resolved 14 June 2011
Resolution: Newly installed cradle allows for unobstructed launching of life rafts on starboard side helo deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 May 2011
Resolved
Paint port and starboard running lights back screen mat black per Colregs Annex 1.
Due 27 June 2011
Resolved 14 June 2011
Resolution: Running light back screen painted in accordance with Colregs Annex 1 as directed during prior inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 May 2011
Resolved
Lower, forward mast head light is not operating. Prove proper operation of the lower, forward mast head light.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2011
Resolved 28 May 2011
Lifesaving › Lifeboat › Propulsion Starting System
Issued 30 December 2008
Resolved
No. 2 Life boat starter failed due to cracked housing.
Condition: Unknown
Due 30 January 2009
Resolved 13 January 2009
Resolution: Vessel received new starter and installed in accordance with manufacturer''s instructions.
Operations/Management › Drills/Instruction › Fire
Issued 20 June 2007
Resolved
Complete fire, abandon ship, man overboard drills
Action required: 705 - Other - as specified
Due 16 January 2008
Resolved 3 January 2008
Resolution: Examined vessel log for drillls conducted; sat.
Construction/Loadline › Hull › Hull Plating
Issued 26 May 2005
Resolved
Provide written documentation that the vessel's current cathodic protection system is operating properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 7 July 2005
Resolution: Operator provided service report indicating that CAPAC power supplies and system is operating properly.
Engineering › Compressed Air System (start air) › Valve
Issued 18 November 2004
Resolved
Hand releasing device missing on relief valve for air receiver.
Condition: Unknown
Due 18 December 2004
Resolved 18 December 2004
Engineering › Compressed Air System (start air) › Compressor
Issued 18 November 2004
Resolved
Cooling fan for ship's air compressor unit failed
Condition: Unknown
Due 18 December 2004
Resolved 18 December 2004
Resolution: renewed fan balde
Fire Fighting › Fire Main
Issued 31 March 2004
Resolved
Main Fire Line piping running through out cargo hold # 3 B leaking at expansion joint which was made of S/S. Vessel to make temp repair and order new part. CG-835 issued to provide class report NLT 31 May 04
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 2 April 2004
Construction/Loadline › Penetrations
Issued 28 July 2003
Resolved
Make permanent repairs to waster piece at low sea suction strainer to the satisfaction of cognizant OCMI on next maintenance repair availability 01SEP03. LEGACY COMPONENT DESC: Waster Piece
Due 1 September 2003
Resolved 29 August 2003
Documentation › Certificates/Documents
Issued 8 November 2002
Resolved
SMC not endorsed since 30JUL99. LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Due 8 February 2003
Resolved 18 March 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 April 2002
Resolved
Provide written report showing testing results and cause of leaks from low pressure CO2 tank. Prior to departure prove proper operation of system components and prove tank is able to maintain correct level as per manufacturer's recommendation. (No sail cleared. Op test conducted 12Jun02)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2002
Resolved 12 June 2002
Fire Fighting
Issued 26 April 2002
Resolved
Provide approved plans for modifications to the galley fire suppression system addressing relocation of pull switch and electrical modifications for shutoffs. (1st extension granted to 8/11/02)
Due 28 February 2003
Resolved 3 May 2003
Resolution: Sigfhted Ltr from MSC on Approval.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 April 2002
Resolved
Prior to departure, provide Coast Guard approved installation plans for low pressure CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2002
Resolved 12 June 2002
Resolution: Vessel provided approval letters showing Coast Guard review of all revisions up to revision "C". Vessel unable to provide stamped approved plans but this office satisfied to let vessel sail.
Documentation › Safety/Response Plans/Programs
Issued 26 April 2002
Resolved
Submit for approval ship's fire control plan. Ensure all symbols meet IMO Resolution A.654(16). LEGACY COMPONENT DESC: Fire Control Plans
Due 28 February 2003
Resolved 18 March 2003
Lifesaving › Lifeboat
Issued 26 April 2002
Resolved
Prior to getting underway, conduct weight test of all lifeboats and rescue boat falls in presence of Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2002
Resolved 11 June 2002
Resolution: Witnessed sat test of all lifeboat and rescue boat falls using 19,176 lbs.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 April 2002
Resolved
Submit to USCG Marine Safety Center revision to fixed fire suppression system for approval addressing new valve type and modifications to piping system. (ist extension granted to 8/11/02)
Due 11 August 2002
Resolved 31 July 2002
Resolution: Received approval letter from CG MSC for modifications.
Engineering › Steering Gear System
Issued 12 December 2001
Resolved
Take rudder clearances as per CFR requirement. LEGACY COMPONENT DESC: Rudder Bearing
Due 15 February 2002
Resolved 14 January 2002
Resolution: Clearance reading given to CG.
Fire Fighting
Issued 4 April 2000
Resolved
MAKE PERMANENT REPAIRS TO LOW PRESSURE CO2 FIXED FIRE FIGHTING SYSTEM VAPORRELIEF LINE. TEMP PATCH MAY BE INSTALLED. REPAIRS MUST BE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 4 April 2000
Resolved
MAKE PERMANENT REPAIRS TO LEVEL INDICATING SYSTEM FOR FIXED LOW PRESSURE CO2 SYSTEM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Construction/Loadline
Issued 2 November 1999
Resolved
REPAIR OIL WATER SEPERATOR FOR MACHINERY SPACES. THIS MUST BE COMPLETED NLT02DEC99. THIS ITEM MAY BE CLEARED BY PROVIDING EVIDENCE THAT THE ORDERED PART HAS BEEN RECEIVED AND A STATEMENT THAT IT HAS BEEN INSTALLED AND TESTED.
Condition: Unknown
Due 2 December 1999
Resolved 28 June 2000
Fire Fighting
Issued 2 November 1999
Resolved
ALL PORTABLE FIRE EXTINGUISHERS MUST BE SERVICED NO LATER THAN 02DEC99. NOTE, THE LAST SERVICE WAS 22MAY98.
Condition: Unknown
Due 2 December 1999
Resolved 28 June 2000
Navigation
Issued 2 November 1999
Resolved
REPAIR OR REPLACE PARTS, AND MAKE OPERATIONAL THE SHIPS HORN. THIS MUST BECOMPLETED NO LATER THAN 02DEC99. THIS ITEM MAY BE CLEARED AS DESCRIBED IN REQUIREMENT #1.
Condition: Unknown
Due 29 February 2000
Resolved 28 June 2000
Engineering
Issued 2 November 1999
Resolved
REPAIR LEAK IN FLANGE IN SALT WATER TO FRESH WATER COOLER. THIS ITEM MUST BE CORRECTED NO LATER THAN 02DEC99. THIS REQUIREMENT MAY BE EXTENDED PROVIDED THE LEAK DOES NOT INCREASE AND THE OWS IN THE MACHINERY SPACE IS REPAIRED, PROVIDING THE ABILITY OF DISPOSAL OF THE ACCUMULATED SEAWATER.
Condition: Unknown
Due 29 February 2000
Resolved 28 June 2000
Navigation
Issued 13 April 1999
Resolved
EVALUATE CAUSE OF STEERING SYSTEM HIGH HYDRALIC OIL TEMP ALARM. MAKE NECESSARY REPAIRS AND PROVE PROPER OPERATION OF THE STEERING SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTION
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Engineering
Issued 25 January 1999
Resolved
EVALUATE CAUSE OF POWER TURBINE BRAKE HIGH TEMP. ON PORT SHAFT. MAKE REPAIRS TO SAME. SUBMIT REPORT TO LOCAL [name withheld] OF ALARM & ACTIONS TAKEN TO CORRECT IT. PROVIDE LOCAL OCMI W/CLASS REPORT INDICATING SATISFACTORY REPAIRS ARE COMPLETE.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Navigation
Issued 25 January 1999
Resolved
EVALUATE CAUSE OF HIGH HYDRAULIC OIL TEMPERATURE ALARM STEERING SYSTEM. TAKE MEASURES NECESSARY TO CORRECT HIGH TEMPERATURE. SUBMIT REPORT TO LOCALOCMI DETAILING CORRECTIVE MEASURES TAKEN AND STATING STEERING SYSTEM OPERATES PROPERLY.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Navigation
Issued 10 December 1998
Resolved
Provide replacement GMDSS receiver screen.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Lifesaving
Issued 10 December 1998
Resolved
Provide proper type and number of line throwing app.
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999