← All vessels
KENNEDY
KENNEDY is a 1967 school ship. The Coast Guard has recorded 166 inspections since 1981, most recently in October 2025, along with 227 deficiencies — 3 with no resolution recorded —, 1 operational control and 5 casualty investigations between 2008 and 2025.
Records from 1981 to 2025. Most recent: inspection, 28 October 2025.
- Built
- 1967
- Last inspected
- 28 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 166
- Deficiencies
- 227 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2008–2025
Identity
509652
6621662 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
KVMU
45599
Flag
UNITED STATES
338919000
Maury page id
psix-45599
Inspections, by type
…with no type recorded37
…past their stated due date3
Years with a record
42 calendar years (1981–2025)
The 166 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13886 - Convention (Subpart B), Gross Ton
4165 - Convention (Subpart B), Net Ton
4165 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
KVMUMMSI 338919000 · active · compulsorily equipped · granted 24 November 2022, expires 27 November 2032
KVMUMMSI not assigned · expired · compulsorily equipped · granted 27 January 1993, cancelled 27 January 1998 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 166
28 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8319288
16 July 2025
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8200100
23 June 2025
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8168625
22 April 2025
Administrative Inspection · Excursion Permit
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8117075
10 February 2025
Drydock Extension
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8099512
5 January 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8121607
11 September 2024
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8008737
31 May 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7904785
6 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7907396
19 April 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7898347
1 April 2024
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7888135
12 February 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7864961
17 January 2024
Excursion Permit
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7850544
12 December 2023
COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7838143
9 November 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7815237
5 June 2023
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7703313
30 May 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7700941
5 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7681941
7 April 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7664665
24 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7656137
3 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7631704
14 December 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7604440
8 September 2022
Internal Structural Exam · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7554053
31 August 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7549012
17 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7536536
24 May 2022
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7457899
4 April 2022
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7424323
23 February 2022
Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7402940
27 September 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7324441
6 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7227284
28 May 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7215413
14 December 2020
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7111555
6 October 2020
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7073703
16 March 2020
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6927585
10 January 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6887030
9 December 2019
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6883255
12 June 2019
Administrative Inspection · In-Service Inspection · COI Inspection · Examination of Repairs · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6706456
25 September 2018
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6545751
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524185
27 August 2018
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6524572
24 July 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6489640
1 May 2018
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6403069
13 March 2018
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6371098
26 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6361903
19 September 2017
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6270251
1 September 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6256877
1 September 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6269983
30 August 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6255077
30 August 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6257101
21 August 2017
COI Inspection · Excursion Permit · MTSA Verification · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6242178
27 July 2017
In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6214959
19 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6216197
18 May 2017
Drydock Extension
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6149594
28 February 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6096375
27 September 2016
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6010380
22 August 2016
COI Inspection · MTSA Verification · Excursion Permit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5980556
25 May 2016
Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5886660
22 March 2016
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5839078
17 August 2015
MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Excursion Permit · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5218440
19 August 2014
COI Inspection · MARPOL Annex V Examination · Excursion Permit · Examination of Repairs · MARPOL Annex I Examination · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4961258
25 June 2014
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4922087
16 June 2014
Deficiency Check · Welding Related Inspections Qualification Testing · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4890532
1 December 2011
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4199648
20 September 2011
Administrative Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4151814
30 August 2011
In-Service Inspection · Examination of Repairs · Deficiency Check · Excursion Permit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4131923
4 August 2011
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4105911
1 August 2011
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4101918
5 January 2011
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3933660
16 September 2010
MARPOL Annex VI Survey · Examination of Repairs · Deficiency Check · Administrative Inspection · MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3858000
1 September 2010
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3839396
19 March 2009
Deficiency Check · Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3436135
6 January 2009
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3389715
30 September 2008
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3330368
21 August 2008
Excursion Permit
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3302447
9 July 2008
Construction Oversight
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3262583
23 March 2008
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3184699
24 September 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3065081
4 June 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2951407
28 March 2007
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2896869
15 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2888621
18 September 2006
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2734626
31 May 2006
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2666544
16 September 2005
Deficiency Check · In-Service Inspection · COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2493793
9 September 2005
In-Service Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2488202
2 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448704
20 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363429
12 May 2005
Deficiency Check · MTSA/ISPS Verification
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2350732
3 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2348224
4 January 2005
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2268698
1 September 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2190903
26 August 2004
Permit to Proceed
Administrative · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2179353
7 August 2004
Attraction Vessel Exam
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2160705
24 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2109087
22 March 2004
COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2030478
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996761
14 April 2003
Underwater Inspection in lieu of Drydock
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1824853
2 April 2003
COI Inspection · MARPOL Annex I Examination · Internal Structural Exam · Construction Oversight · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1700590
14 August 2002
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1661481
8 May 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063693
20 February 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058073
12 October 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 823561
14 July 2000
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1051795
5 May 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818139
3 December 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1463537
25 October 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397260
25 November 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805861
12 November 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 35305
10 November 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1111385
23 October 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 777402
1 October 1997
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368436
25 September 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378192
14 April 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092697
8 April 1997
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1104756
28 March 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096242
7 November 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1170612
21 June 1996
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390373
2 April 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1422658
7 March 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1078523
23 February 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885078
2 November 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1175594
8 August 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866452
1 June 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852717
23 March 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1148493
19 March 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1448416
26 February 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1463038
22 January 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1447209
17 December 1992
Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356162
14 February 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961919
6 February 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 955493
17 December 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953211
22 October 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245831
16 September 1991
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1244502
31 July 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251190
23 July 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 528240
2 July 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1002427
7 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922877
22 March 1991
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 500618
31 December 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1226339
6 December 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924651
8 September 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 929584
9 August 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213030
10 January 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 910422
18 July 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 890808
17 March 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041627
11 February 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1021822
9 March 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1320272
27 February 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312671
5 February 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011452
13 May 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987089
13 May 1986
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988302
8 March 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 440346
18 June 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982386
4 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289562
17 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979565
4 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285902
25 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974895
23 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978268
4 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975878
19 March 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280593
9 November 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1276604
8 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967296
21 January 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1276534
14 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277033
19 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968351
21 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963543
12 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967871
Deficiency record · 227
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 April 2024
Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of section 5.1 of the Code. The rescue boat has a crack IVO the keel. Temporary repairs are authorized, permanent repairs to be conducted at next dockside availability. Permanent repairs to be made to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 April 2024
No resolution recorded
The fire integrity of the divisions shall be maintained at openings and penetrations. The Officer Laundry, Aft upper, door casing is misaligned, cannot be closed properly. Vessel to overhaul and provide closure to meet the regulation at next drydock.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 April 2024
Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. Numerous stair tower self-closing doors need adjustments to ensure they close even under any supplied ventilation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2024
No resolution recorded
Metallic band strapping used for cable support should be steel and corrosion treated if not a corrosion-resistant material. Cable retention devices should be installed not less than every 610 mm on vertical runs and not less than every 2.5 m on horizontal runs. Vertical wire runs in the machinery space noted for plastic zip-tie type fasteners. Provide metallic IAW with regulation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 April 2024
No resolution recorded
Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in paragraph
2.2.3.2.2 shall be fitted with: suitably located hatches for inspection and cleaning. The dryer exhausts in the Officer laundry are of vertical installation. Process for scheduled clean/inspection to be implemented to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2024
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship ...The purpose of this regulation is to limit the fire growth potential in every space of the ship. Vessel had high alcohol content hand sanitizer being stored in linen closest. Relocated all flammable products to the appropriate storage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 December 2022
Resolved
Complete underway testing of the main turbine low lube oil trip, and overspeed trip. Provide objective evidence of completion to the CGMI to include statement from the Chief Engineer, License number and signature.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2022
Resolved
MSC Letter E2-1904271 directed the submittal of Periodic Safety Test Procedures for the alarm and monitoring system upgrade in accordance with 46 CFR 61.40. Submit PSTP to the Marine Safety Center for approval and provide approval documentation to the local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2022
Resolved
PSTP for Burner Management and Combustion Control, Rev. 7 is Not Approved by the USCG. Further more MSC Letter E2-1704764 for Rev. 6 was returned for revision. Submit ICI Doc No: TSK 800-03, Rev. 7, "Burner Management and Combustion Control System Periodic Safety Test Procedure", dated 07JAN2018 or most current version witnessed by a Coast Guard Marine Inspector to the Marine Safety Center for approval and provide approval documentation to the local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2022
Resolved
Number one main feed / coffin pump has high vibration alarm. Upon investigation the pump will need to be rebuilt due to water in oil, Tech rep onsite. Complete repairs and test to the satisfaction of the Coast Guard Marine Inspector (CGMI).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2022
Resolved
Piping, Including Flanges, conveying vapors, gases or liquids whose temperature exceeds 150'F shall be suitably insulated where necessary to preclude injury to personnel. Multiple areas of missing or damaged insulation. Replace or repair insulation on all piping systems that exceed 150'F to the satisfaction of the CGMI.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 28 November 2022
Resolved
Onboard a seagoing vessel to which this subpart applies, no person may assign any person to perform shipboard duties, and no person may perform those duties, unless the person performing them has received - (1) Training in personal survival techniques as set out in the standard of competence under Regulation VI/1 of the STCW Convention (incorporated by reference, see § 15.103 of this part); or (2) Sufficient familiarization training or instruction.
two OS and 3 other crew did not have STCW endorsement. Replacements were brought on board for OS.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 February 2022
Resolved
If, during an internal structural examination, damage or deterioration to the hull plating or structural members is discovered, the OCMI may require the vessel to be drydocked. Diesel fuel was disovered in the port side cofferdam hotwell.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 February 2022
Resolved
If, during an internal structural examination, damage or deterioration to the hull plating or structural members is discovered, the OCMI may require the vessel to be drydocked. Deflection of 05 bulkheads, as well as minor cracking near the top longitudinals as a result, was discovered in the #6 Port side Dry Ballast tank. Must be repaired at vessel's next drydock.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 February 2022
Resolved
If, during an internal structural examination, damage or deterioration to the hull plating or structural members is discovered, the OCMI may require the vessel to be drydocked. A cracked weld was discovered in Port Side Dry Ballast tank #6 at frame 155, at the 3rd longitudinal inboard, roughly 7 feet inboard of the tank inner wall. Must be repaired at vessel's next drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2021
Resolved
“E” lighting signage is missing throughout the vessel. Apply the appropriate signage as per 46 CFR 131.840
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 October 2020
Resolved
PSTPs shall be conducted PTCP
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 October 2020
Resolved
Vessel must conduct MOB, Fire and Abandon ship and security drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 October 2020
Resolved
Operationally test engineering equipment to include, SSTGs, Safety valve easing gear and safety valves.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 December 2019
Resolved
Aft peak tank top plating for the upper tween deck and fwd peak chain locker sump bottom #1 & #2 breast hooks plating gauging indicates remaining thickness in localized areas does not meet ABS rules. The aft peak upper tween tank top was found to be over 30% wastage, which is conidered excessive allowable limits.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 November 2018
Resolved
Vessel must complete a fire and abandonship drill with vessel crew and cadets prior to getting underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 November 2018
Resolved
Vessel must demonstrate PSTPs for both main boilers, steam turbines, SSTGs, and Aux Generator.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 November 2018
Resolved
Vessel must provide licenses and documents for ship's crew.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 25 September 2018
Resolved
Vessel must demonstrate ship's OWS.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V).
Lifesaving › Launching Appliances › Falls
Issued 19 September 2017
Resolved
Renew falls for LB/RB #5, LB/RB #6, and FASS/FSR at next dry-dock NLT 31 March 2018. Not to exceed 5 years from 13 SEP 2013.
Electrical › Electric Generation Source (service) › Generator
Issued 30 August 2017
Resolved
Auto regulator on #2 steam turbine generator failed.
Engineering › Steam Boiler (propulsion) › Fuel Oil Burner
Issued 21 August 2017
Resolved
Tag out LSMGO system for both boilers. In addition, install new and approved fuel oil hoses for the LSMGO burner front. Test system with USCG prior to putting new system in service.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 January 2017
Resolved
The class III sliding watertight door located between # and #4 hold has small hydraulic weep within the hydraulic cylinder behind the bulkhead. The bulkhead will need to be removed to identify the exact location of the weep. ABS, CG, and MARAD Rep are confident the door still operates as designed; however, it needs to be corrected. Vessel is to provide a corrective action to the CG.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 January 2017
Resolved
The portside supply fan flex joint coupling is wasted. Repair or replace during credit drydock.
Fire Fighting › Fire Hoses › Condition
Issued 27 September 2016
Resolved
Hydrostatically test 73 (43 1.5" and 30 2.5") fire hoses in the presence of a CG Marine Inspector. Prior to getting U/W.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 September 2016
Resolved
Service fixed fire fighting system, semi-portable systems, and portable extinguishers prior to getting U/W.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 September 2016
Resolved
Demonstrate fixed system C02 time delay to the satisfaction of a CG Marine Inspector. Prior to getting u/w.
Lifesaving › Lifeboat › Propulsion Engine
Issued 25 May 2016
Resolved
Lifeboat #6 does not function/operate as designed. Reduced overall passenger count by the amount #6 lifeboat is designed to carry.
Engineering › Steam Turbine (propulsion) › Casing
Issued 22 March 2016
Resolved
Several cracks found in casing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 September 2015
Resolved
AMR spac delay failed the test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2015
Resolved
Stanchion base fwd of hawse pipes middle was wasted.
Fire Fighting › Ventilation Systems › Ducts
Issued 23 September 2015
Resolved
Supply ventialtion automatic damper in EDG space would not close when EDG was shutdown.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 23 September 2015
Resolved
rate and rise of heat actuator not functioning in battery.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 23 September 2015
Resolved
venilation dampers not functioning in the UPS room.
Deck/Cargo › Towing › Chocks
Issued 23 September 2015
Resolved
Renewe stanchion base fwd of hawse pipe middle stanchion.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 24 August 2015
Resolved
LED light did not illuminate when test was conducted nor did the alarm activate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 August 2015
Resolved
AMR and OIL transfer delays failed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 August 2015
Resolved
3m Radar was not integrated with AIS.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 18 August 2015
Resolved
The switch board panel is missing a blank.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 August 2015
Resolved
the engine room door displayed a yellow light kighlighting a failure.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 August 2015
Resolved
Ring buoy lights batteries have expired.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 17 August 2015
Resolved
The embarkation lighting is out in several areas.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 17 August 2015
Resolved
life boat #1 battery is dead.
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 17 August 2015
Resolved
Multiple items were missing from rescue boat.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 17 August 2015
Resolved
Orange smoke on ring buoy is not CG approved.
Fire Fighting › Fire Hydrants › Condition
Issued 17 August 2015
Resolved
#1 fire pump does not work in remote operation.
Engineering › Steam Boiler (propulsion) › Superheater
Issued 17 August 2015
Resolved
Steam pipe in super heater escaping through a pin hole leak.
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 17 August 2015
Resolved
Conduct PSTP using approved PSTP rev 5.
Communications › Public Address System › Loudspeaker
Issued 22 November 2011
Resolved
Prove proper operation of public address speakers in list provided to [name withheld].
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 20 September 2011
Resolved
Complete DVTP/FMEA & PSTP revision & documentation process for Boiler Burner Management/Combustion Control systems, to wit: Inclusion of field changes to FMEA & test procedures; Addition of summary indicator audible/visual alarm for loss of PLC output control; Resubmission of FMEA & test documentation with changes to OCMI & MSC for verification & final approval.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 20 September 2011
Resolved
Prove proper operation of UPS room ventilation damper closure caused by under/low voltage to vent damper control circuit . Provide prior to end of scheduled dry-dock.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 December 2010
Resolved
Correct emergency lighting fixtures and/or labels in the attached list.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 5 November 2010
Resolved
Replace damaged stanchion on starboard aft quarter of lifeboat #5
Stability › Weathertight Integrity › General
Issued 27 October 2010
Resolved
Repair light/leaks in cargo hatches as identified with vessel representatives.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 October 2010
Resolved
Conduct maintenance, documentation and operational testing of all lifeboats IAW 46 CFR 167.35-1 and 46 CFR 199.190.
Fire Fighting › Automatic Sprinkler System › Testing Means for Pump
Issued 27 October 2010
Resolved
Conduct satisfactory PMS and testing IAW NFPA 25 on the automatic sprinkler pump.
Documentation › Markings/Placards › Warning Signs
Issued 27 October 2010
Resolved
Provide missing instruction placards for manual operation in the quarterdeck cabinet.
Stability › Weathertight Integrity › General
Issued 16 September 2010
Resolved
Conduct chalk tests to the engine room hatch on port side and two vents on starboard forward main deck.
Stability › Watertight Integrity › General
Issued 16 September 2010
Resolved
Properly repair the open/close indicator light on the #140 Upper 'tween sliding watertight door.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 16 September 2010
Resolved
Replace batteries on the #7 lifeboat or demonstrate satisfactory operation (maintain a charge).
Fire Fighting › Automatic Sprinkler System › Pump
Issued 16 September 2010
Resolved
Make permanent repairs to sprinkler pump packing gland fasteners. A licensed engineer is to perform daily examination of packing gland retaining bolts to ensure they remain tight and have not shifted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2010
Resolved
Provide a automatic CO2 activated pressure switch to secure the F/O transfer pump upon activation of the CO2 fixed firefighting system
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 September 2010
Resolved
Provide approved plans, and address SFP for EGEN Space; existing steel door not rated/ not self closing, ventilation trunk no damper, bulkhead insulation. (door is orig construction, ventilation new install and insulation new install 2003 (voluntary SOLAS p/MARAD).
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 16 September 2010
Resolved
Provide approved plans, and address SFP for UPS Space : ventilation trunk no damper, bulkhead insulation, ventilation /cooling not adequate for space heat dissipation.(Installed in 2003 voluntary SOLAS p/MARAD).
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 16 September 2010
Resolved
Provide "A" class door between chart room/bridge and corridor, as depicted on FCP.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2009
Resolved
Transverse bulkhead frame 42, pinhole fuel oil leak in oil tight collar. 2nd tank top long outboard of inboard long bulkhead. Cause appears to be start stop of weldment when installed.
Stability › Watertight Integrity › General
Issued 8 January 2009
Resolved
Submit proposal for permanent repairs for the wasted area on Focsle deck IWO port anchor windlass.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 January 2009
Resolved
Ensure all vessel documents reflect name change of vessel.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 January 2009
Resolved
Ensure vessel is fully secured for sea.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 September 2008
Resolved
Ensure EAP is fully implemetned onboard vessel (training/signage).
Engineering › Steam Boiler (propulsion) › Blowdown System
Issued 9 July 2008
Resolved
Prior to lighting fires in ships boilers a NDT of all 12 header drains inside these boilers shall be performed and all necessary repairs made to satisfaction of USCG Marine Inspector.
Engineering › Steam Boiler (propulsion) › Blowdown System
Issued 9 July 2008
Resolved
Make permanent repair proposla to USCG Sector SENE which addresses permanent correcive actions to be taken to rectify the corroded conditions found on stbd boiler superheater inlet drain adn fwd watewall header drain and port boiler fwd sidewall header drain. This repair proposal and rpairs must be accomplished to the USCG satisfaction prior to lighting fires in these boilers.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 March 2007
Resolved
The remote controlled motor operated ventilation supply damper for the Oil Handling Room does not work. As such, there shall be no fuel oil or lube oil processing and/or handling operations in this space until permanent repairs have been made to this damper assembly to the satisfaction of an attending USCG Marine Inspector.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 15 March 2007
Resolved
The vessel's cargo gear shall be placed in an out of commission status and shall not be operated until such time as a Cargo Gear Certificate has been issued to the ship upon completion of satisfactory permanent repairs to same.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 12 January 2007
Resolved
Remote motor operated ventilation supply damper for Oil Handling Room does not work. Manual damper to be employed at upper boat deck until repairs have been made but no later than March 15, 2007.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 12 January 2007
Resolved
Cargo gear certificate is not issued due to no weight test being performed after major overhaul during dockside availblity of 2006. Cargo gear not to be operated until such certificate is produced.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 October 2006
Resolved
Greater than 20 main vertical zone fire screen doors were found to be tied open, blocked open with wooden wedges, and otherwise physically obstructed during COI exam. Ship's master to address situation with ship wide policy note NLT Friday October 13, 2006.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 October 2006
Resolved
18 Fire screen doors noted to be inoperative as discussed in Activity # 2734626. Permanent repairs to these doors shall be accomplished prior to embarking passengers to satisfaction of USCG.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 12 October 2006
Resolved
General Alarm contactor is being used as Engineer [name withheld] contactor in lower level of engine room. replace improper contactor with correct unit prior to being placed in service to satisfaction of USCG.
Engineering › Steam Turbine (propulsion) › Casing
Issued 12 October 2006
Resolved
Numerous coffee cans were noted hung under bearing journal caps on main reduction gear fwd casing on lower level in engine room. Remove fire hazards created by these cans, fix the leaks and demonstrate to USCG satisfactory conditions upon completion of this job and prior to starting turbine on steam.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 October 2006
Resolved
Emergency Generator found with an intermittent "failure to start" problem. This shall be trouble shot by qualified personnel and rectified prior to departing to sea to the satisfaction of an attending USCG inspector.
Fire Fighting › Automatic Sprinkler System › Connection to Fire Main
Issued 29 September 2006
Resolved
The vessel's "Nav Lab" sprinkler system Marine Safety Center approval remains outstanding this date. This space shall remain unoccupied AND this sprinkler system is NOT to be tied into the remainder of the ship's system until such time as this approval is received from the USCG Marine Safety Center.
Fire Fighting › Fire Main › Condition
Issued 18 September 2006
Resolved
Ship's crew shall rig and prove a satisfactory secondary means of fire main supply from the ship's pier. The ship currently does not have 2 operational fire pumps as required by 46 CFR 167.45-5(c)(1). This secondary source of fire main shall be independent of any potable water supply and solely dedicated to the fire main of the vessel.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 18 September 2006
Resolved
The vessel's "Nav Lab" sprinkler system Marine Safety Center approval remains outstanding this date. This space shall remain unoccupied AND this sprinkler system is NOT to be tied into the remainder of the ship's system until such time as this approval is received from the USCG Marine Safety Center.
Fire Fighting › Fire Pumps › Power Source
Issued 18 September 2006
Resolved
Ship's crew shall rig and prove a satisfactory secondary means of fire main supply from the ship's pier that will serve as the vessel's second required fire pump as the ship currently does not have 2 operational fire pumps as required by 46 CFR 167.45-5(c)(1).
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 18 September 2006
Resolved
4 Light fixtures found to be not explosion-proof as required in the aft paint locker. This to be corected prior touse to satisfaction of USCG.
Engineering › Steam Turbine (propulsion) › Valve, Regulating
Issued 18 September 2006
Resolved
Chief Engineer to provide a written affadavit attesting to the satisfactory operational testing of the vessels main unit overspeed limiting device within the first 72 hours of underway operations.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 18 September 2006
Resolved
New sprinkler system zone does not accurately reflect ont he fire control panel on the bridge when tested. This system to be reprogrammed prior to the vessel sailing on it's upcoming cadet cruise.
Lifesaving › Lifeboat › Carriage Requirement
Issued 13 December 2005
Resolved
For sea-trial purposes only, vessel may reduce lifeboat capacity provided that crew & persons in addition to crew do not exceed aggregate life boat capacity. Reduced life boat carriage requirement is allowed to expedite the completion of item #24 of 21OCT05.
Fire Fighting › Fire Main › Material
Issued 13 December 2005
Resolved
Prior to sailing with cadets, replace pipe elbow (in way of temporary repair) on discharge side of newly installed fire pump.
Electrical › Electric Generation Source (service) › Panelboard
Issued 13 December 2005
Resolved
Prior to sailing with cadets repair frequency (cycle) meter on main board.
Engineering › Pressure Vessel › Piping
Issued 13 December 2005
Resolved
Prior to sailing with cadets, provide proof of hydrostatic testing of all new ship service air piping to 1.5 times MAWP.
Engineering › Pressure Vessel › Marking and Stamping
Issued 13 December 2005
Resolved
Submit for approval, the design and installation plans for the newly installed ship service air compressor and associated piping to USCG marine safety center.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 December 2005
Resolved
Submit for approval, change specifications and installation details of newly installed electric fire pump that replaced steam driven pump.
Lifesaving › Launching Appliances › Release Mechanism
Issued 21 October 2005
Resolved
Lifeboat #1 and #5 found with damaged or inoperative releasing gear. Both boats are to be repaired and demonstrated to be fully operational prior to the vessel sailing with cadets.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
AMR CO2 system emergency shutdown pressure switches (2) did not work when testing system. Switches as follows; Ventilation, FSD closures, WTD controllers. 46CFR/76.15
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
60 second time delay for AMR did not work when tested. Renew and retest. 46CFR/76.15-30
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
Audible alarms for AMR space and control room did not work when tested. Renew and retest. 46CFR/167.45
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
Tine delay for fwd bosn' stores is unreasonably short @ 30 seconds, replace with a 60 second delay to account for personnel working in bow thruster space. 46CFR/76.15-30
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 16 September 2005
Resolved
Provide documentation proving plan review and subsequent approval has been completed on main emergency shutdown circuit junction box and panel board trunk lines located in AMR control room in the form of an ABS approved wiring diagram or other acceptable method. 46CFR/111.01-1(3).
Construction/Loadline › Structures › Machinery Space Opening
Issued 16 September 2005
Resolved
Shaft alley WTD is inoperative both on activation of CO2 system and/or activation of local operating control. Repair same and retest. 46CFR/76.15
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
Data logger room automatic ventilation shutdown on CO2 activation is inoperative. Prove proper operation of this system. 46CFR/76.15-35.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 September 2005
Resolved
Data logger room has open and unprotected high voltage circuits, improperly dead-ended cicuits, open panel boards, missing panel covers, spare parts / boxes / file cabinets / misc junk all located in same room. Correct these listed items to comply with 46CFR111.01-1(1)(2)(3) and (4).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 16 September 2005
Resolved
Smoke detection system for cargo holds and data logger room found to be inoperative. This system is to be fully overhauled and demonstrated fully operational. 46CFR76.33-20
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 16 September 2005
Resolved
Flexible loops for CO2 system have not been hydro tested to 1000 PSIG as required. Vessel is to test 12 loops and properly label the tested loops and provide servicing report to OCMI at conclusion of these tests. 46CFR147.65(d)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 16 September 2005
Resolved
Labels for the various local actuating bottle stations in the CO2 room are missing or illegible. Permanently mark these operating stations to satisfaction of USCG inspector. 46CFR78.47-17
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 16 September 2005
Resolved
Provide a servicing report for the missing 9 bottles of CO2 from CO2 room. 46CFR76.15-5(a)
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 16 September 2005
Resolved
Found sprinkler zone for main deck aft in mess deck zone valve tamper switch and zone flow switch to both be inoperative. This zone to be overhauled and retested to satisfaction of USCG inspector. 46CFR/76.25-35
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 16 September 2005
Resolved
Found sprinkler zone for upper deck aft house ladder well fan room zone valve tamper switch and zone flow switch to both be inoperative. This zone to be overhauled and retested to satisfaction of USCG inspector. 46CFR/76.25-35
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 16 September 2005
Resolved
Found sprinkler zone upper tween deck #6 hold zone valve tamper switch and zone flow switch to both be inoperative. This zone to be overhauled and retested to satisfaction of USCG inspector. 46CFR/76.25-35
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 16 September 2005
Resolved
Found hold #3 lower level being used as a store room for life saving gear, engine spare parts, gaskets, boxes paper goods etc. No fire detection or fire supression system in place or operational in this area. Remove flammables or reclassify space to allow stowage of this gear and fix the FF system, 46CFR72.05
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 September 2005
Resolved
Provide a receipt for missing pyrotechincs and food rations for all life boats to [name withheld]. 46CFR199.175.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 September 2005
Resolved
Proprly label ALL staterooms and berthing areas with IMO Res A760(18) style labeling the location of each lifejacket (AND immersion suit if so equipped) to comply with 46CFR199.178.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 September 2005
Resolved
Galley automatic fire damper and ventilation shutdowns for fixed gas fire fighting system found to be inoperative upon testing. Overhaul and restes the is system to satisfaction of USCG inspector. 46CFR/76.15-35
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 16 September 2005
Resolved
Provide labels outside of all doors giving access to interior of hospital spaces that indicate that stowage of oxygen tanks is in the hospital area and that the stowage of greater than 85 M3 of oxygen is prohibited by law. 46CFR147.85.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 16 September 2005
Resolved
Complete COI exam all items of section 3 exam booklet CG840HI and as noted in joint COI exam booklets. 46CFR/71.25-10
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 16 September 2005
Resolved
Found oxygen bottles in storage in hospital space and an operating room designation in place without the space being rated as a hazardous location and equipped with Class I Division I expolsion proof fittings and fixtures. Retrofit this space to meet Class I Div I ratings or reclassify the space and use to meet non-Haz classification. 46CFR/111.105
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 September 2005
Resolved
Engine room CO2 system emergecny shutdown pressure switches (6) did not work when testing system. Switches as follows; WTD, Motor driven F/O pup, Turbine driven F/O pump, Ventilation, P&S Forced draft blowers. Repair all and retest same. 46CFR/76.15
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 January 2005
Resolved
Due to CO2 smothering system, holds #1 and #2 are to be designated as "unmanned spaces" and shall not be utilized as workshops, classrooms, or training spaces. This requirement does not prohibit occasional and limited entry associated with a hold or storage space. Requirement maintains in effect until vessel compliant with 46 CFR 167.45-1(c)(4)
Fire Fighting › Automatic Sprinkler System › Pump
Issued 15 January 2005
Resolved
Complete plan approval for sprinkler installation to navigation laboratory per MSC letter dated 30 SEPT 04. (Serial # E1-0402606).
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 January 2005
Resolved
Label physical locations of fire control dampers and ensure they are identified on the fire control plan (FCP). 46 CFR 78.45-1 During inspection noted that ventilation damper controls were marked on FCP, but that actual damper locations within system were not identified.
Engineering › Diesel Engine (auxiliary)
Issued 2 April 2003
Resolved
Prove proper operation of auxiliary generator after installing new speed control module. LEGACY COMPONENT DESC: Overspeed Device
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 2 April 2003
Resolved
Prior to sailing with cadets onboard, conduct fire and boat drills, davit launched liferaft deployment and abandon ship drill to the satisifaction of the attending marine inspector. Per aggreement with MSO Providence.
Lifesaving
Issued 3 December 1999
Resolved
PRIOR TO DEPARTURE FROM NEXT PORT, BOTH LIFEBOAT FALLS ARE TO BE RENEWED.
Engineering
Issued 3 December 1999
Resolved
SUBMIT NEXT 3 (THREE) SHAFT OIL ANALYSIS REPORTS TO THIS OFFICE (MOBMS), ONE EVERY 6 MONTHS.
Engineering
Issued 1 October 1997
Resolved
Demonstrate a proper test of the relief valve for DC Heater.
Construction/Loadline
Issued 1 October 1997
Resolved
Demonstrate proper operation of starboard deep bilge well pump.
Construction/Loadline
Issued 2 April 1996
Resolved
Conduct water hose test of hatch covers that were repaired, in presence of marine inspector.
Electrical
Issued 2 April 1996
Resolved
Replace electrical outlets in crew laundry on main deck with water tight type._x001C_
Fire Fighting
Issued 2 April 1996
Resolved
Replace firemain pressure gage on bridge._x001C_
Navigation
Issued 2 April 1996
Resolved
Provide means for conducting alcohol testing._x001C_
Engineering
Issued 2 April 1996
Resolved
Provide accurate boiler feedwater level indicators per 46CFR62.35-20(b)_x001C_
Engineering
Issued 2 April 1996
Resolved
Provide approved automation test procedures per 46CFR61.40._x001C_
Fire Fighting
Issued 2 April 1996
Resolved
Make fire damper closure operable in fan room aft main deck, just behind door._x001C_
Navigation
Issued 2 April 1996
Resolved
Provide training certification for operator of alcohol testing device._x001C_
Construction/Loadline
Issued 2 April 1996
Resolved
Provide documentation to prove nonmetallic expansion joints, in systems which penetrate the hull and both the penetration and expansion joint are below deepest load waterline, have been manufactured within 10 years or replace at deactivation per 46 CFR 61.15-12.
Electrical
Issued 1 June 1994
Resolved
RELAMP SHAFT ALLEY EMERGENCY ESCAPE.
Documentation
Issued 1 June 1994
Resolved
PROVIDE OIL TRANSFER PROCEDURES IAW 33CFR155.728
Navigation
Issued 1 June 1994
Resolved
INSTALL STATION DIRECTORY FOR FWD LOOKOUT PHONE.
Lifesaving
Issued 1 June 1994
Resolved
PROVIDE PROOF THAT LIFEBOAT FALLS WERE END FOR ENDED AND WEIGHT TESTED IN PRESENSE OF COAST GUARD.
Documentation
Issued 1 June 1994
Resolved
PROVIDE UP TO DATE RADIO TELEGRAPHY CERTIFICATE.
Electrical
Issued 1 June 1994
Resolved
REPAIR/REPLACE BURNT OUT EMERGENCY LIGHTS.
Unknown
Issued 26 February 1993
Resolved
REPLENISH MEDICAL SUPPLIES UPON VESSEL'S ACTIVATION OR AT THE NEXT INSPECTION FOR CERTIFICATION BUT NOT LATER THAN 17 DECEMBER 1994.
Electrical
Issued 22 January 1993
Resolved
UPDATE VESSEL'S ELECTRICAL ONE LINE DIAGRAM TO INCLUDE THE NEW HOT WATER HEATER AND LUBRICATING OIL HEATER. SUBMIT PLANS FOR APPROVAL. (46 CFR 110.25-1)._x001C_ _x001C_
Construction/Loadline
Issued 17 December 1992
Resolved
REPAIR HOLE IN AFT BULKHEAD OF NO. 1 CARGO HOLD AT THE UPPER TWEEN'DECK NEAR THE BOTTOM OF THE VERTICAL LADDER FROM THE MAINDECK HATCH._x001C_ _x001C_ _x001C_
Navigation
Issued 17 December 1992
Resolved
RENEW STEERING GEAR PORT UNIT LEFT RUDDER PRESSURE GUAGE._x001C_ _x001C_ _x001C_ _x001C_
Unknown
Issued 17 December 1992
Resolved
RENEW OUTDATED MEDICAL SUPPLIES._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE SOLAS APPROVED LIGHTS FOR ALL PFDS AND EXPOSURE SUITS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE NEW CONDENSED MILK SUPPLIES FOR BOTH LIFEBOATS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE 1 GALLON OF STORM OIL FOR EACH LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE ONE 8" ADJUSTABLE WRENCH FOR STARBOARD LIFEBOAT TOOL KIT._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE NEW WATER RATIONS TO REPLACE THOSE RATIONS OLDER THAN 5 YEARS._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE NEW BATTERIES FOR ALL RINGBUOYS WITH LIGHTS ATTACHED (9) TOTAL._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
ENSURE ALL PFDS AND EXPOSURE SUITS HAVE VESSEL NAME STENCILED ON THEM, APPROXIMATELY 10 WERE MISSING PROPER NAME._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE/RENEW RETROREFLECTIVE TAPE ON FOUR PFDS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
RENEW SUCTION AND DISCHARGE SIDE PIPING TO FUEL OIL SERVICE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 17 December 1992
Resolved
RENEW RADIOTELEGRAPH CERTIFICATE WITH FCC._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 17 December 1992
Resolved
RENEW RADIOTELEPHONE CERTIFICATE WITH FCC_x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
RENEW BATTERIES IN EMERGENCY GEAR LOCKER HAND LATERNS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
CALIBRATE DC HEATER HIGH LEVEL ALARM._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
CALIBRATE STARBOARD BOILER SUPERHEATER OUT TEMPERATURE GUAGE._x001C_ _x001C_ _x001C_ _x001C_
Unknown
Issued 17 December 1992
Resolved
PROVIDE AFFIDAVIT ON PROPER OPERATION OF THE A/C SYSTEM, EVAPORATOR, AND OWS WHILE ON SEA TRIALS._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE RECERTIFICATION PLACARD FOR NO. 2 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 17 December 1992
Resolved
REPAIR HOLE ON BACK SIDE OF FOREPEAK GOOSENECK VENT ON STARBOARD SIDE OF THE FOC'SLE._x001C_ _x001C_ _x001C_
Documentation
Issued 17 December 1992
Resolved
PROVIDE UNDERWATER SURVEY PLAN (REFERENCE MARKS PLAN, VIDEO, COATING SYSTEMDATA) TO MSO PORTLAND FOR REVIEW AND FORWARDING TO CG HEADQUARTERS (G-MVI)_x001C__x001C_ _x001C_
Electrical
Issued 17 December 1992
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR HIGH JACKET WATER TEMPERATUREALARM ON REMOTE ALARM PANEL IN ENGINEROOM._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 17 December 1992
Resolved
PROVIDE OPEN DOOR LATCHES AND LABEL DOORS "LATCH DOOR OPEN WHEN OCCUPIED" FOR THOSE COMPARTMENTS WITH CO2 BOTTLES STORED IN THEM AND THE DOORS OPEN INTO THE COMPARTMENT._x001C_ _x001C_
Electrical
Issued 17 December 1992
Resolved
REPAIR/RENEW FAN MOTOR FOR FORWARD BOS'N LOCKER VENTILATION SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 17 December 1992
Resolved
Demonstrate proper operation of power actuated sea valve for emergency firepump._x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
REPAIR MAIN CONDENSER DISCHARGE VALVE BODY AND HYDROTEST._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
MAKE PROPER FRP REPAIRS ON LIFEBOAT HULLS IN ACCORDANCE WITH FILE WORKLIST_x001C__x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
RENEW SUPERHEATER TUBES IN BOTH BOILERS WHICH HAVE EXCESSIVE WASTAGE AS DETERMINED BY U.T., SEE FILE ,FOR EXACT NUMBER OF TUBES RENEWED._x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
RENEW COLLAPSED CONDENSER TUBE INLET INSERTS._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 17 December 1992
Resolved
REPAIR HOLES IN BULKHEAD BETWEEN CARGO HOLDS NO. 5 AND 6 AT FIRST DECK LEVEL BELOW THE MAINDECK_x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
REPAIR BROKEN REFRACTORY IN BOTH BOILER FIREBOXES._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 17 December 1992
Resolved
REPAIR TWO FIRE DAMPERS AND SHOW PROPER OPERATION OF THE SAME._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE NEW BATTERIES FOR LIFEBOAT FLASHLIGHTS AND SPARES._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
PROVIDE THREE ADDITIONAL PARACHUTE FLARES FOR THE STARBOARD LIFEBOAT_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
RENEW THE STARBOARD AFT SUPPLY FAN MOTOR FOR THE ENGINEROOM SUPPLY VENTILATION._x001C_ _x001C_ _x001C_
Engineering
Issued 17 December 1992
Resolved
PROVIDE CG APPROVED PIPING AND ELECTRICAL PLANS ON THE LUBE OIL PURIFIER HEATER._x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
PROVIDE CG APPROVED PIPING AND ELECTRICAL PLANS FOR THE SEWAGE SYSTEM MODIFICATIONS._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 December 1992
Resolved
END FOR END BOTH SETS OF FALLS ON LIFEBOAT DAVITS._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
PROVIDE CG APPROVED PIPING AND ELECTRICAL PLANS ON THE INSTALLATION OF THE POTABLE WATER SYSTEM HEATER._x001C_ _x001C_ _x001C_
Electrical
Issued 17 December 1992
Resolved
PROVIDE CG APPROVED ELECTRICAL PLANS ON THE 230 VOLT REEFER CONTAINER DECK WIRING INSTALLATIONS._x001C_ _x001C_ _x001C_
Engineering
Issued 22 October 1991
Resolved
SUBMIT TAILSHAFT LUBE OIL ANALYSIS TO [name withheld] OIL ANALYSIS MUSTSTATE IF LUBE OIL IS SATISFACTORY OR NOT FOR SERVICE INTENDED AND INCLUDE METALS CONTENT AND WATER CONTENT._x001C_ _x001C_
Construction/Loadline
Issued 16 September 1991
Resolved
MAKE PERMANENT REPAIRS TO THE WASTED ROSE BOXES IN HOLD #2 PORT AND STBE, AND HOLD #6 STBD.
Engineering
Issued 16 September 1991
Resolved
MAKE OPERABLE OR REMOVE ENTIRELY THE BRIDGE THROTTLE CONTROL SYSTEM. THE SYSTEM IS NOT TO BE USED FOR ANY REASON UNTIL COMPLETED.
Engineering
Issued 16 September 1991
Resolved
PROVIDE A SUITABLE HIGH TEMPERATURE ALARM FOR THE #1 MAIN FEED PUMP LUBE OIL.
Engineering
Issued 16 September 1991
Resolved
MAKE OPERABLE THE HIGH LEVEL ALARMS FOR BOTH FUEL OIL SETTLER TANKS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 16 September 1991
Resolved
SUBMIT FOR APPROVAL THE MODIFICATIONS DONE ON THE ENGINE ROOM ALARM PANEL.
Navigation
Issued 6 December 1990
Resolved
PROVE PROPER OPERATION OF STEERING MOTOR POWER FAILURE AUDIBLE ALARM ON BRIDGE.
Engineering
Issued 6 December 1990
Resolved
PROVE OPERATION OF MACHINERY SPACE AND SHAFT ALLEY BILGE ALARMS.
Electrical
Issued 6 December 1990
Resolved
PROVE PROPER OPERATION OF #2 SSTG REVERSE POWER TRIP INDICATOR.
Fire Fighting
Issued 6 December 1990
Resolved
REPAIR LEAK IN FIRE MAIN BLANKS AFT OF 6"X4" REDUCER.
Engineering
Issued 6 December 1990
Resolved
RE-CALIBIRATE THE FOLLOWING GAUGES: 1) #1 FEED PUMP DISCH PRES 2) P&S SUPHTR OUTLET PRES 3) STBD DESUPHTR OUTLET TEMP 4) PORT SUPHTR OUTLET TEMP 5) MAIN STEAM TEMP
Navigation
Issued 6 December 1990
Resolved
MAKE REPAIRS AND PROVE THE OPERATION OF THE RUDDER ANGLE INDICATOR ON THE BRIDGE COLUMN.
Lifesaving
Issued 6 December 1990
Resolved
GENERAL ALARM BELLS IN ENGINE ROOM WEAK. VERY DIFFICULT TO HEAR. ALL DEFICIENT BELLS TO BE REPAIRED BEFORE LEAVING SAN FRANCISCO BAY.
Lifesaving
Issued 6 December 1990
Resolved
MAKE REPAIRS TO FIBERGLASS IN PORT LIFEBOAT.
Lifesaving
Issued 6 December 1990
Resolved
MAKE REPAIRS TO LEAKING EXHAUST ON STARBOARD LIFEBOAT.
Electrical
Issued 6 December 1990
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM AND TRIP ON #2 SSTG. ENSURE THAT LOW LUBE OIL ALARM SOUNDS BEFORE THE GENERATOR TRIPS.
Engineering
Issued 6 December 1990
Resolved
LIFT RELIEF VALVES ON THE FOLLOWING PRESSURE VESSELS: 1) DC HEATER 50 PSIG MAWP 2) CONTROL AIR RECEIVER 110 PSIG MAWP
Engineering
Issued 6 December 1990
Resolved
RE-PACK PORT PISTON ON STEAM RECIPROCATING FEED PUMP.
Engineering
Issued 6 December 1990
Resolved
LIFT RELIEF VALVE ON CONTAMINATED EVAP.
Lifesaving
Issued 9 August 1990
Resolved
SERVICE INFLATABLE LIFERAFT IAW 46 CFR 91.25-15(A)(6).
Fire Fighting
Issued 9 August 1990
Resolved
REPAIR OR RENEW THE CO2 TIME DELAY FOR SHAFT ALLEY.
Fire Fighting
Issued 9 August 1990
Resolved
PROVIDE ONE ADDITIONAL FIREMAN'S OUTFIT IAW 46 CFR 96.35-10(B).
Fire Fighting
Issued 9 August 1990
Resolved
LABEL DOOR TO EMERGENCY GENERATOR ROOM TO READ "LASH DOOR OPEN WHEN ROOM ISOCCUPIED."
Fire Fighting
Issued 9 August 1990
Resolved
LABEL CO2 PULLS OUTSIDE OF SHAFT ALLEY IAW 46 CFR 95.15-10(H).
Engineering
Issued 5 February 1987
Resolved
PROVIDE USCG APPROVED PLANS ON OILY WATER SEPARATOR & BILGE MONITOR INSTALLATION (INCLUDING PIPING & ELECTRICAL MODIFICATIONS)
Construction/Loadline
Issued 5 February 1987
Resolved
PROVIDE APPROVED PLANS ON SIDESHELL MOORING BIT INSTALLATION.
Engineering
Issued 5 February 1987
Resolved
PROVIDE INFORMATION ON WHEN & WHERE THE OILY WATER SEPARATOR & BILGE MONITOR WERE INSTALLED AND WHICH COAST GUARD OFFICE WITNESSED THE INSTALLATION.
Engineering
Issued 23 January 1985
Resolved
SHOW SATISFACTORY OPERATION OF BRIDGE THROTTLE CONTROL.
Engineering
Issued 23 January 1985
Resolved
PROVIDE A RELIEF VALVE OF THE PROPER SIZE AND CAPACITY FOR THE SHIP'S SERVICE AIR RECEIVER.
Unknown
Issued 23 January 1985
Resolved
MAKE OPERABLE WATER LEVEL INDICATOR FOR STARBOARD BOILER AT THE CONTROL PANEL.
Electrical
Issued 23 January 1985
Resolved
MAKE NECESSARY REPAIRS TO THE #2 MAIN CONDENSATE PUMP MOTOR CONTROLLER.
Engineering
Issued 23 January 1985
Resolved
SHOW SATISFACTORY OPERATION OF THE OILY WATER SEPARATOR.
Fire Fighting
Issued 23 January 1985
Resolved
PROVIDE PROPER PROTECTIVE CLOTHING FOR THE FIREMAN'S OUTFIT IN THE MACHINERY SPACE.
Documentation
Issued 23 January 1985
Resolved
POST THE REQUIRED OIL POLLUTION PLACARDS.Y 33 CFR 155.440.
Lifesaving
Issued 23 January 1985
Resolved
CONDUCT A SUSPENSION/WEIGHT TEST OF THE PORT LIFEBOAT IN THE PRESENSE OF A U. S. COAST GUARD MARINE INSPECTOR.
Engineering
Issued 23 January 1985
Resolved
SHOW PROPER OPERATION OF THE THROTTLE WRONG DIRECTION ALARM.
Construction/Loadline
Issued 14 October 1982
Resolved
MAKE PERMANENT REPAIRS TO THE RIVETED SEA OR AT THE J-11 AND K-11 PLATES INTHE #4 CARGO HOLD PORT SIDE TO THE SATISFACTION OF A COAST GUARD MIO INSPEC
Casualty record · 5
23 March 2008Routine · role: Involved in a Marine Casualty · activity 3184699
12 February 2013Routine · role: Involved in a Marine Casualty · activity 4539736
12 February 2013Routine · role: Involved in a Marine Casualty · activity 4597439
23 June 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8168625
16 July 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8200100
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 2
ENTERPRISE (2008), T S KENNEDY (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.