← All vessels
FV TIGER
Commercial Fishing Vessel · Fishing Vessel class · Built 1960s · USCG Northwest District (CGD-NW) · Other hulls named FV TIGER
FV TIGER is a 1967 commercial fishing vessel. The Coast Guard has recorded 50 inspections since 1985, most recently in June 2017, along with 58 deficiencies and 4 casualty investigations between 2009 and 2013.
Records from 1985 to 2017. Most recent: inspection, 7 June 2017.
- Built
- 1967
- Last inspected
- 7 June 2017
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 58 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2009–2013
Identity
509741
WDG9131
45602
Flag
UNITED STATES
367584650 (licence lapsed)
Maury page id
psix-45602
Inspections, by type
…with no type recorded10
Years with a record
18 calendar years (1985–2017)
The 50 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)46.6 ft × 16.0 ft × 6.6 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKAZULIN-COLE SHIPBUILDING · TACOMA, WA, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHARLESTON, OR
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDG9131MMSI 367584650 · expired · voluntarily equipped · granted 25 July 2013, cancelled 30 September 2023
WN3984MMSI not assigned · expired · compulsorily equipped · granted 17 September 1996, cancelled 17 February 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 50
7 June 2017
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6195869
13 January 2017
Type not recorded
No type recorded · Station Coos Bay · USCG Northwest District (CGD-NW) · Activity 6070909
16 February 2012
Type not recorded
No type recorded · Station Yaquina Bay · USCG Northwest District (CGD-NW) · Activity 4245986
16 February 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4273260
4 July 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3575570
9 April 1999
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 788182
30 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 785206
22 July 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1424632
13 February 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112643
6 August 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1118472
15 July 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1378105
5 June 1997
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1450032
21 May 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1102265
29 April 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1091143
10 April 1997
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1098266
20 February 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1107431
13 September 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1435787
30 April 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1081310
4 April 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1079504
2 April 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1078174
8 March 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 885218
2 February 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 871680
11 December 1995
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1371237
31 July 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394346
1 May 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031389
8 June 1994
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382789
12 August 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1158290
12 August 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385121
9 April 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1459802
12 August 1992
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 945146
27 February 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1270906
29 January 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 958588
16 December 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1262822
29 August 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1249161
12 July 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1248693
12 June 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 892937
8 April 1991
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 949942
8 April 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1236365
21 December 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1240884
10 August 1990
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1232056
9 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1214431
7 June 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1226840
30 May 1989
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1206753
28 February 1989
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1196901
28 June 1988
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030731
13 June 1988
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030926
22 May 1987
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334022
12 December 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1008085
16 September 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1020275
2 July 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1291132
Deficiency record · 58
Fire Fighting
Issued 30 March 1999
Resolved
SUBMIT PLANS FOR APPROVAL OF FIXED FIREFIGHTING SYSTEM. UPON APPROVAL OF_x001C_ PLANS, COMPLETE INSTALLATION OF SYSTEM AND MAKE AVAILABLE FOR INSPECTION.
Electrical
Issued 22 July 1998
Resolved
MAKE A/C OUTLETS AND SWITCH BOXES, IN ENGINE ROOM, DRIP PROOF.
Navigation
Issued 22 July 1998
Resolved
PROVE PROPER OPERATION OF STEERING GEAR.
Electrical
Issued 22 July 1998
Resolved
PROVIDE PROPER SUPPORT AND CONNECTIONS FOR WIRING IN ENGINE ROOM.
Construction/Loadline
Issued 22 July 1998
Resolved
PROPERLY REPAIR OR REPLACE AS ORIGINAL, FORWARD ESCAPE HATCH TO ENSURE WATERTIGHT INTEGRITY.
Engineering
Issued 22 July 1998
Resolved
PROVE PROPER OPERATION OF MAIN PROPULSION.
Construction/Loadline
Issued 15 July 1997
Resolved
PROVE PROPER OPERATION OF THE ENGINE DRIVEN BILGE PUMP.
Lifesaving
Issued 15 July 1997
Resolved
REPAIR OR REPLACE THE NET ON THE 7 PERSON LIFEFLOAT.
Lifesaving
Issued 5 June 1997
Resolved
REPLACE THE DRYROTTED NET FOR THE 10 PERSON CAPACITY LIFEFLOAT. UNTIL CORRECTED, MAXIMUM PERSONS ONBOARD LIMITED TO 7 PERSONS; OR 14 PERSONS ON LIMITED COASTWISE ROUTES.
Construction/Loadline
Issued 5 June 1997
Resolved
PROPERLY MARK THE VALVES FOR THE BILGE MANIFOLD AND PROVIDE STOP/CHECK VALVES AT THE MANIFOLD OR CHECK VALVES IN EACH BILGE COMPARTMENT.
Construction/Loadline
Issued 5 June 1997
Resolved
PROVIDE A WATERTIGHT COVER FOR THE ANCHOR CHAIN FAIRLEAD.
Lifesaving
Issued 5 June 1997
Resolved
PROVIDE INFORMATION ON THE COMPANY DRUG TESTING EMPLOYEE ASSISTANCE PROGRAM.
Lifesaving
Issued 5 June 1997
Resolved
PROVE PROPER OPERATION OF THE BILGE, PROPULSION, AND STEERING SYSTEMS.
Navigation
Issued 5 June 1997
Resolved
PROVIDE CURRENT NAUTICAL CHARTS AND PUBLICATIONS.
Accommodation/Occupational Safety
Issued 5 June 1997
Resolved
TIGHTEN THE PORT AND STARBOARD RAILS.
Lifesaving
Issued 5 June 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 5 June 1997
Resolved
REPAIR OR REPLACE THE SPLIT PADDLE FOR THE LIFEFLOAT.
Construction/Loadline
Issued 5 June 1997
Resolved
PROPERLY REPAIR THE FRAME/POST IN THE AFT PORT SCUPPER--CURRENTLY NECKED DOWN AND ROTTED NEAR CONNECTION WITH DECK.
Construction/Loadline
Issued 5 June 1997
Resolved
PROPERLY REPAIR THE HOLES IN THE DECK AT PORT BOW NEAR THE ANCHOR CHAIN FAIRLEAD AND PORT AFT NEAR FISH HOLD.
Electrical
Issued 5 June 1997
Resolved
PROPERLY SECURE THE LOOSE WIRING IN THE MID-CABIN VOID.
Electrical
Issued 5 June 1997
Resolved
REPLACE THE WIRE NUT UNDER THE STOVE WITH A PROPER PRESSURE TYPE CONNECTOR.
Lifesaving
Issued 5 June 1997
Resolved
PROVIDE A FIRST AID KIT IN COMPLIANCE WITH 46 CFR 160.041 OR EQUIVALENT.
Accommodation/Occupational Safety
Issued 5 June 1997
Resolved
MARK THE INSIDE OF THE FORWARD EMERGENCY ESCAPE HATCH, ALL LIFEJACKET STOWAGE AREAS, AND EMERGENCY FUEL SHUT OFFS.
Lifesaving
Issued 21 May 1997
Resolved
TOTAL PERSONS ALLOWED ON OCEANS ROUTE LIMITED TO 17 PERSONS UNTIL THE PRIMARY LIFESAVING CAPACITY IS RESTORED TO 18 PERSONS.
Construction/Loadline
Issued 10 April 1997
Resolved
INSTALL BUTT BLOCKS AT PLANK 5 BETWEEN FRAMES 4 AND 5 ON PORT AND STARBOARDSIDES COUNTING FROM FIRST SISTERED FRAME AT MIDSHIPS FORWARD. REMOVE ALL ROT FROM EXISTING FRAMES AND INSTALL BUTT BLOCKS BETWEEN REMAINING GOOD WOOD OF ALL 4 FRAMES.
Unknown
Issued 13 September 1996
Resolved
PROVE PROPER OPERATION OF MAIN DIESEL AND STEERING GEAR.
Unknown
Issued 13 September 1996
Resolved
CONDUCT UNDERWAY MAN OVERBOARD DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Unknown
Issued 13 September 1996
Resolved
SISTER OR REPLACE IN LIKE KIND AND QUALITY AS ORIGINAL THE FRAMEHEADS IN BOW WHERE NECKED DOWN, AS DIRECTED BY MARINE INSPECTOR. REPAIRS ARE TO BE APPROVED PRIOR TO STARTING. REPAIRS SHALL BE MADE AT OR PRIOR TO NEXT DRYDOCK.
Construction/Loadline
Issued 11 December 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, WITH COAST GUARD MARINE INSPECTOR PRESENT, CONDUCT OPERATIONAL TEST OF HULL IN SEAWAY._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 11 December 1995
Resolved
CROP OUT ROTTED WOOD BACK TO GOOD WOOD AND REPLACE USING GOOD MARINE PRACTICE WOOD IN WAY OF PORT BRIDGE DOOR, TRUNK CABIN WINDOW, AND REAR PORTION CABIN STRINGER, AFT (ALONG MAIN DECK).
Construction/Loadline
Issued 8 June 1994
Resolved
PROVE PROPER OPERATION OF BILGE PUMPS.
Construction/Loadline
Issued 8 June 1994
Resolved
CONDUCT AN OPERATIONAL TEST OF THE VESSEL'S HULL TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR.
Lifesaving
Issued 8 June 1994
Resolved
OBTAIN THREE ADULT LIFE PRESERVERS OR LIMIT THE NUMBER OF PASSENGERS TO 21 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Engineering
Issued 8 June 1994
Resolved
PROVE PROPER OPERATION OF THE MAIN PROPULSION ENGINE.
Navigation
Issued 8 June 1994
Resolved
PROVE PROPER OPERATION OF ELECTRONIC NAVIGATION EQUIPMENT.
Documentation
Issued 12 August 1992
Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Documentation
Issued 12 June 1991
Resolved
CONDUCT STABILITY TEST FOR EXPOSED WATERS.
Lifesaving
Issued 12 June 1991
Resolved
INSTALL NEW FLOAT LIGHT ON LIFEFLOAT.
Engineering
Issued 12 June 1991
Resolved
REPLACE BOTH FUEL OIL TANKS WITH PROPER SIZE AND MATERIAL TO THE SATISFACTION OF THE OCMI.
Lifesaving
Issued 12 June 1991
Resolved
INSTALL NEW RETROREFLECTIVE TAPE ON LIFEFLOAT.
Construction/Loadline
Issued 21 December 1990
Resolved
RE-CORK SEAMS BETWEEN KEEL AND GARBOARD PLANK THE ENTIRE LENGTH OF VESSEL_x001C_ BOTH PORT AND STBD SIDES.
Construction/Loadline
Issued 21 December 1990
Resolved
PULL AT LEAST SIX FASTENERS FROM FWD PART OF VESSEL BELOW WATERLINE._x001C_ COAST GUARD INSPECTOR TO EXAMINE FASTENERS.
Construction/Loadline
Issued 21 December 1990
Resolved
MAKE READY FOR INSPECTION BOTTOM PLANK AFT IN WAY OF RUDDER POST AND PLANK_x001C_JUST FORWARD OF STRUT. CLEAN OUT ALL DEBRIS AND ENSURE PLANKS ARE VISIBLE.
Engineering
Issued 21 December 1990
Resolved
REPAIR CRACK ON ONE OF PROP FLUMES. IF REPAIR CANNOT BE MADE, REPLACE_x001C_ PROP.
Construction/Loadline
Issued 21 December 1990
Resolved
UNDERGO SEA TRIALS.
Engineering
Issued 7 June 1990
Resolved
PROVE SATISFACTORY OPERATION OF MAIN ENGINE AND ENGINE DRIVEN BILGE PUMP.
Engineering
Issued 7 June 1990
Resolved
PROVIDE CG APPROVED FUEL HOSE FOR OIL STOVE.
Construction/Loadline
Issued 7 June 1990
Resolved
RENEW FLEXIBLE BILGE LINE ON BILGE PUMP IN MID-SHIPS COMPT.
Construction/Loadline
Issued 7 June 1990
Resolved
DOUBLE CLAMP ALL FLEXIBLE HOSES ON THROUGH HULL FITTINGS ESPECIALLY ON PUMPS IN LAZARETTE AND MID-SHIPS COMPT.
Construction/Loadline
Issued 7 June 1990
Resolved
LABEL VALVES ON BILGE MANIFOLDS.
Engineering
Issued 13 June 1988
Resolved
REPLACE SHAFT TO PREVENT LEAKAGE.
Electrical
Issued 13 June 1988
Resolved
PUT IN-LINE FUSE IN BILGE PUMP WIRING FROM BATTERY.
Engineering
Issued 13 June 1988
Resolved
PROVIDE NEW CLUTCH CABLE.
Fire Fighting
Issued 13 June 1988
Resolved
PERFORM HYDROSTATIC TEST OF 3RD B-II FIRE EXTINGUISHER. OIL STOVE NOT TO BE OPERATED UNTIL THIS REQUIREMENT IS MET.
Navigation
Issued 22 May 1987
Resolved
MAKE THE LORAN C RECEIVER OPERATE PROPERLY.
Electrical
Issued 16 September 1986
Resolved
UPGRADE WIRING UNDER PILOT HOUSE AND REPLACE SWITCHBOX COVERS.
Lifesaving
Issued 16 September 1986
Resolved
PROVIDE 6 ORANGE APPROVED FLARES.
Fire Fighting
Issued 16 September 1986
Resolved
SERVICE 2-BI FIRE EXTINGUISHERS AND PROVIDE ADDITIONAL B-II FOR GALLEY STOVE.
Casualty record · 4
4 July 2009Routine · role: Involved in a Marine Casualty · activity 3575570
16 February 2012Routine · role: Involved in a Marine Casualty · activity 4273260
17 January 2013Routine · role: Involved in a Marine Casualty · activity 4532368
17 August 2013Routine · role: Involved in a Marine Casualty · activity 4690287
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
TIGER (2009–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.