MAURY USCG vessel records
← All vessels

TONKAWA

Built
1967
Last inspected
24 May 2017
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 24 May 2017
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1983–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCP5527
Flag
VANUATU
Tonnage
2825 - Convention (Subpart B), Gross Ton 847 - Convention (Subpart B), Net Ton
Maury page id
psix-45622
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 53

24 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6154532
21 April 2004 Deficiency Check
Physical examination · Activities Europe · Activity 2048916
21 April 2004 Deficiency Check
Physical examination · Activities Europe · Activity 2048921
16 January 2004 Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 1986185
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972225
7 February 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1741515
23 January 2003 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1734332
26 November 2002 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1685766
25 September 2002 Permit to Proceed
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1680232
7 March 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410522
25 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213071
28 December 2000 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058943
26 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049807
13 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818480
12 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 776251
28 June 1999 Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447976
16 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811421
21 January 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212102
6 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 673105
25 June 1998 Drydock Extension · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423035
15 June 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416721
5 May 1998 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790624
6 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212980
22 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438624
15 May 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400363
23 May 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355244
26 May 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401894
11 April 1994 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389773
2 August 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158542
21 June 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370638
23 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 675885
16 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 87439
30 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 675884
23 June 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 169128
18 June 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391777
17 July 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249480
8 March 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901144
4 October 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223001
18 July 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911291
20 July 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198417
2 February 1989 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032668
22 July 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034693
7 July 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021020
18 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293359
7 March 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999341
1 November 1985 Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993490
14 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987286
24 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283526
17 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283470
6 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280326
21 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972401
15 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275304
4 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271823

Deficiency record · 26

Fire Fighting › Firemans Outfit
Issued 23 February 2004 Resolved
1. Fireman's outfits incomplete. Provide complete fireman's outfits to comply with 46CFR 96.35-10. LEGACY COMPONENT DESC: Lantern (Electric Safety Lamp)
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 21 April 2004
Resolution: Received notification that fireman''s outfit was provided on board. Verifiy at next visit to the vessel.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 February 2004 Resolved
2. Properly service liferafts at a U.S. Coast Guard Approved Facility. LEGACY COMPONENT DESC: LIFERAFTS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 13 July 2004
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 23 February 2004 Resolved
3. Properly mount all liferafts. Provide weak links and hydrostatic releases. LEGACY COMPONENT DESC: Designated Location
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 23 February 2004
Operations/Management › Lifesaving
Issued 23 February 2004 Resolved
4. Properly mark liferaft areas with number of persons and raft numbers. In accordance with 46CFR 199.178.
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 21 April 2004
Resolution: Received notification requirement completed. Verifiy at next visit to the vessel.
Electrical › Lighting (emergency)
Issued 23 February 2004 Resolved
5. Provide proper lighting for liferaft embarkation areas IAW 46CFR 111.75-16 and 46CFR 199.110. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 21 April 2004
Resolution: Received notification requirement completed. Verifiy at next visit to the vessel.
Operations/Management › FireFighting
Issued 23 February 2004 Resolved
6. Properly mount portable fire extinguisher in the crane, renew broken windows, provide and post hand signal chart, provide legible control markings, LEGACY COMPONENT DESC: Crane portable fire extinguisher.
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 21 April 2004
Resolution: Received notification requirement completed. Verifiy at next visit to the vessel.
Operations/Management › FireFighting
Issued 23 February 2004 Resolved
7. Complete annual servicing of the fixed CO2 system and semi-portable fire extinguishing systems. Restore fixed CO2 system to compliance with approved plans. LEGACY COMPONENT DESC: Fixed CO2 semi portable CO2
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 3 May 2004
Resolution: Received e mail copies of sevicing certificates. Verify satisfactory at next visit to the vessel.
Operations/Management › Drills/Instruction › Fire
Issued 23 February 2004 Resolved
8. Provide and post proper operating instructions for the fixed CO2 system and the semi-portable fire extinguishing systems. LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 13 July 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 February 2004 Resolved
9. Trouble shoot repair and prove proper operation of the oily water separator prior to returning vessel to service. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2004
Resolved 13 July 2004
Electrical › Electric Generation Source (service)
Issued 26 November 2002 Resolved
Prove proper operation and test alarms and shutdownds on nr2 diesel generator. LEGACY COMPONENT DESC: Number of Sources
Due 10 February 2003
Resolved 10 February 2003
Resolution: Tested generator operation, alarms and shutdowns.
Operations/Management › FireFighting
Issued 26 November 2002 Resolved
Update fire safety plan for equipment onboard and IMO symbology. LEGACY COMPONENT DESC: Fire Safety Plan
Due 10 February 2003
Resolved 16 April 2003
Resolution: Reviewed and approved updated fire and safety plan.
Pollution Prevention/Response › Prevention Equipment
Issued 26 November 2002 Resolved
Prove proper operation of second OWS or remove from service. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 10 February 2003
Resolved 10 February 2003
Resolution: Tested OWS operation and alarms.
Deck/Cargo › Cargo Transfer (solid)
Issued 26 November 2002 Resolved
Provide third party certification for both deck cranes after repairs are complete. LEGACY COMPONENT DESC: Deck Crane
Condition: Unknown
Due 10 February 2003
Resolved 11 April 2003
Resolution: Received and reviewed copy of ABS statement of fact for load test on Derrick crane ABSID 6703757, test satisfactory.
Engineering › Pressure Vessel
Issued 26 November 2002 Resolved
Make ready for inspection and prove proper operation of relief valve for divers air pressure vessel. LEGACY COMPONENT DESC: Relief Valve
Due 10 February 2003
Resolved 10 February 2003
Resolution: Received third party reports for relief valve test, all satisfactory.
Lifesaving
Issued 26 May 1994 Resolved
STENCIL "BEWARE OF TAIL ROTOR" ON STAIR RISERS APPROACHING HELO DECK.
Condition: Unknown
Due 23 June 1994
Resolved 8 June 1994
Engineering
Issued 26 May 1994 Resolved
RENEW AIR RECEIVER LOCATED WITHIN GANTRY DUE TO EXCESSIVE CORROSION TO THE_x001C_SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 June 1994
Resolved 5 July 1994
Electrical
Issued 26 May 1994 Resolved
RENEW STUFFING TUBES IN PAINT LOCKER LIGHT FIXTURES WITH EXPLOSION-PROOF_x001C_ TYPE.
Condition: Unknown
Due 23 June 1994
Resolved 8 June 1994
Engineering
Issued 26 May 1994 Resolved
RENEW EXHAUST LAGGING FOR EMERGENCY GENERATOR AND EMERGENCY FIRE PUMP_x001C_ PRIMEMOVERS.
Condition: Unknown
Due 23 June 1994
Resolved 8 June 1994
Engineering
Issued 26 May 1994 Resolved
RENEW FUEL HOSES WITH APPROVED TYPE HOSE/FITTING ASSEMBLIES ON ALL GENER-_x001C_ ATOR PRIMEMOVERS AND ON EMERGENCY FIRE PUMP PRIMEMOVER.
Condition: Unknown
Due 23 June 1994
Resolved 8 June 1994
Electrical
Issued 26 May 1994 Resolved
RENEW CLEAR PLASTIC METER FACE COVER OF AMMETER IN BATTERY CHARGER SERVING_x001C_GENERAL ALARM SYSTEM.
Condition: Unknown
Due 23 June 1994
Resolved 8 June 1994
Unknown
Issued 18 July 1990 Resolved
PROVIDE ON BOARD A COPY OF VESSEL STABILITY LETTER DATED 19FEB70, MAIL A COPY TO THE ADDRESS ABOVE TO CLEAR THE REQUIREMENTS.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Construction/Loadline
Issued 1 November 1985 Resolved
MAKE PERMENANT REPAIRS TO DAMAGED TRAMSVERE BULKHEAD IN WAY OF #2 AND #3 STBD BALLAST TANKS IN ACCORDANCE WITH GOOD MARINE PRACTICE TO THE SATIS- FACTION OF A CG MARINE INSPECTION ON OR BEFORE 01MAR86
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Construction/Loadline
Issued 1 November 1985 Resolved
MAKE PERMENANT REPAIRS TO DAMAGED TRANSVERSE FRAMES AND ASSOCIATED SHELL PLATE IN WAY OF #2 IS BASLLAST TANKS IS SPECIFICALLY THE 1ST AND SECOND FRAMES FROM THE AFT BHD IN ACCORDANCE WITH GOOD MARINE PRACTICE TO THE SATISACTION OF A CG MARINE
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Construction/Loadline
Issued 1 November 1985 Resolved
MAKE PERMENANT REPAIRS TO DAMAGED SIDE SHELL AND BILGE KNUCKLE IN WAY OF CEMENT BOX PATCHES IN #2 AND #3 STBD BALLAST TANKS AT THE COMMON TRANSVERSEBHD IN ACCORDANCE WITH GOOD MARINE PRACTICE TO THE SATISFACTION OF A CG INSPECTOR ON OR BEFORE 01MAR86.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Electrical
Issued 17 August 1984 Resolved
INSTALL AND PROVE PROPER OPERATION OF A HIGH WATER TEMPERATURE ALARM ON THE#3 SERVICE GENERATOR ENGINE.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Unknown
Issued 4 April 1983 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL TONKAWA, DN510178.
Condition: Unknown
Due 4 April 1983
Resolved 4 April 1983

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.