← All vessels
ENLIGHTENED ENERGY
ENLIGHTENED ENERGY is a 1967 tank barge. The Coast Guard has recorded 26 inspections since 1985, most recently in November 1996, along with 16 deficiencies.
Records from 1985 to 1996. Most recent: inspection, 6 November 1996.
- Built
- 1967
- Last inspected
- 6 November 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
510254
45624
Flag
UNITED STATES
—
Maury page id
psix-45624
Inspections, by type
…with no type recorded7
Years with a record
11 calendar years (1985–1996)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it2776 - Regulatory (Subpart C or D), Net Ton
2776 - Regulatory (Subpart C or D), Gross Ton
2776 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
6 November 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1430305
29 August 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871061
19 May 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929280
18 May 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 179942
24 February 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 67907
13 January 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132521
8 July 1994
COI Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866285
6 July 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174677
24 March 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946287
15 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916847
26 February 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1240146
17 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900674
10 April 1990
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1212965
22 March 1990
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918365
13 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216275
9 February 1990
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 904881
1 November 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341746
21 March 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340516
11 May 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039323
3 February 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323437
8 January 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317877
5 November 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024351
23 March 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327852
22 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1307258
20 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979762
4 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283200
Deficiency record · 16
Construction/Loadline
Issued 19 May 1995
Resolved
GAS FREE AND MAKE AVAILABLE FOR INSPECTION CARGO TANKS 1 - P,S, 3P, AND VOIDS 1-P,S, 3P AND FOREPEAK. VESSEL NOT TO CARRY CARGO UNTIL INSPECTION AND ANY REQUIRED REPAIRS ARE COMPLETED TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Fire Fighting
Issued 8 July 1994
Resolved
PROVIDE TWO (2) B-II PORTABLE FIRE EXTINQUISHERS. NOTE: VSL IS RESTRICTEDFROM LOADING CARGO PRIOR TO MEETING THESE REQUIREMENTS.
Deck/Cargo
Issued 8 July 1994
Resolved
PROVE PROPER OPERATION OF THE TANK LEVEL ALARM SYSTEM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Documentation
Issued 22 March 1990
Resolved
VESSEL MAY BE USED AS A RETENTION FACILITY PIER SIDE ONLY.
Construction/Loadline
Issued 22 March 1990
Resolved
#3 VOID SPACE STBD SIDE MUST BE VISUALLY INSPECTED FOR LEAKAGE TWICE DAILY AND CONDITION LOGGED.
Construction/Loadline
Issued 22 March 1990
Resolved
REQ 1, 2 & 3 ISSUED BY NYCMI ON 21MAR90 ARE PREDICATED UPON SATISFACTORY COMPLETION OF TEMPORARY REPAIR DESCRIBED IN NYCMI REQ #1 THIS DATE.
Construction/Loadline
Issued 22 March 1990
Resolved
VESSEL IS ALLOWED TO PROCEED BETWEEN YONKERS TREATMENT FACILITY AND REPAIR FACILITY AS NEEDED TO COMPLETE PERMANENT IN WAY OF BILGE WRAPPER #3 STBD VOID SPACE.
Construction/Loadline
Issued 21 March 1989
Resolved
IN CONJUNCTION WITH REQ #5 THE PERSON IN CHARGE OF BARGE MUST VISUALLY INSPTHE CONDITION OF THE TEMP REPAIR PRIOR TO LOADING & IMMEDIATELY AFTER DISCHARGING CARGO. THE CONDITION OF THE REPAIR MUST BE LOGGED. ANY BREACH OF CRACKING OF THE REPAIR MUST BE REPORTED IMMEDIATELY TO [name withheld].
Construction/Loadline
Issued 21 March 1989
Resolved
PRIOR TO LOADING CARGO PUMP OUT WATER IN FORWARD RAKE AND CONDUCT EXAMINATION OF THE SAME, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Construction/Loadline
Issued 21 March 1989
Resolved
CROP TO GOOD METAL AND INSERT WASTED AREA IN WAY OF TEMPORARY WELD REPAIR IN FORWARD BULKHEAD OF NO. 1 CARGO TANK. TEMPORARY REPAIR IS A WELDED 9" CRACK APPROXIMATELY 5FT DOWN FROM DECK (IMMEDIATELY BELOW ENTRANCE TO FORWARD RAKE).
Documentation
Issued 21 March 1989
Resolved
PROVIDE UPDATED LOAD LINE CERTIFICATE.
Accommodation/Occupational Safety
Issued 21 March 1989
Resolved
PROVIDE APPROVED MSD ON BOARD AND REMOVE ALL EXISTING PIPING UNDER DECK.
Construction/Loadline
Issued 21 March 1989
Resolved
REPAIR AS NEEDED GOOSE NECK VENTS: STARBOARD SIDE NUMBERS 1 AND 3 (FORE TO AFT), PORT SIDE NUMBERS 1,3, AND 4; ALSO MAKE REPAIRS TO AFT PEAK VENT STARBOARD SIDE.
Navigation
Issued 21 March 1989
Resolved
PROPERLY MOUNT STERN LIGHT.
Accommodation/Occupational Safety
Issued 8 January 1988
Resolved
REMOVE DRAIN LINE FROM HEAD SHOWER , AND SINK INSTALLATION. THIS OPENING TO THE CARGO TANK IS NOT PERMITTED IN ACCORDANCE WITH 46 CFR 32.60-10(C)(2)INSERT NEW PLATE IN WAY OF DRAIN LINE TO RESTORE CARGO TANK WALL INTEGRITY.
Accommodation/Occupational Safety
Issued 5 November 1987
Resolved
PROVIDE APPROVED PLANS FOR SEWAGE HOLDING SYSTEM OR REMOVE TOILET FROM VESSEL. UNTIL THIS REQUIREMENT IS COMPLIED WITH TOILET PIPING MUST BE SECURED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.