MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 02

STRETCH DUCK 02 is a 1944 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 1997, most recently in December 2017, along with 8 deficiencies.

Records from 1997 to 2017. Most recent: inspection, 14 December 2017.

Built
1944
Last inspected
14 December 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

456292
Flag
UNITED STATES
—
Maury page id
psix-456292

Inspections, by type

…with no type recorded6
Years with a record 20 calendar years (1997–2017)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

14 December 2017 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6326053
30 January 2017 Administrative Inspection · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6079941
23 February 2016 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5820181
8 December 2015 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5777671
26 October 2015 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5750758
24 October 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5750921
14 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4815970
21 February 2012 Damage Survey · COI Inspection · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4255066
26 September 2011 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4154792
22 December 2010 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3914725
8 December 2010 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3897155
19 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653000
22 October 2008 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3346134
22 February 2007 In-Service Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891264
26 October 2006 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2797830
25 October 2005 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2498209
1 March 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301488
23 August 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2173978
16 December 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965091
17 September 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1876335
9 July 2002 Construction Oversight · Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1626737
28 January 2002 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1480429
14 September 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 211967
27 April 2000 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 819365
17 April 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214751
24 May 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 806376
13 April 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1463478
31 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 810150
8 April 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442696
16 April 1997 COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1371785

Deficiency record · 8

Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 October 2015 Resolved
On 10/24 recieved phone call from [name withheld] that SD 02 had lost propulsion.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2015
Resolved 27 October 2015
Resolution: Received email verfication of findings and repairs. In/out water test was completed. Test SAT.
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2010 Resolved
Water intrusion noted during waterborne portion of inspection. Small amount of water was accumulating just forward of the axle hump under the engine. Internal and external inspection counld not determine source. Possible fracture in laminated frame or shock mounts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2011
Resolved 6 April 2011
Resolution: All hull repairs have been completed and tested sat. Vessel returned to service.
Engineering › Pressure Vessel › Marking and Stamping
Issued 19 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 22 December 2010
Resolution: 12 PSI pressure switch and 25 PSI relief valve installed in air axle presurrization system.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007 Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 August 2008
Resolution: Company modified heat detcection system to now include electrical supervision and 2 sources of power.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2006 Resolved
Have vessel inspected by the CG prior to placing back into service. This vessel missed it's annual by more than ninety days.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 October 2006
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 25 August 2004 Resolved
Properly mount vapor detector in engine compartment.
Condition: Improper/Lack of Maintenance
Due 26 August 2004
Resolved 25 August 2004
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 16 December 2003 Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460.
Condition: Improper Installation
Due 17 March 2004
Resolved 25 August 2004
Construction/Loadline › Hull › Hull Plating
Issued 9 July 2002 Resolved
Found support bracket for forward drive shaft tube welded only 50%.
Due 12 July 2002
Resolved 10 July 2002
Resolution: Company re-welded bracket.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.