Records from 1981 to 2011. Most recent: operational control imposed, 20 September 2011.
Stability › Unintentional Flooding › General
Issued 18 September 2011
Resolved
Provide check valves for port and stbd galley deck drains IAW 46 CFR115.430.
Due 23 December 2011
Resolved 22 December 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 September 2011
Resolved
Identify and properly repair exhaust leak in the lazarette IAW 46 CFR 119.430.
Due 23 December 2011
Resolved 18 January 2012
Documentation › Markings/Placards › Warning Signs
Issued 18 September 2011
Resolved
Update and post upper deck max capacity signs IAW 46 CFR122.
Due 23 December 2011
Resolved 22 December 2011
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 September 2011
Resolved
Provide drug test results for 3 remaining crew IAW 46CFR16.
Action required: 705 - Other - as specified
Resolved 22 December 2011
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2010
Resolved
Make permanent repairs to the galley deck in way of the two clad welded holes on the port side of CL and for the drill stopped deck fracture just stbd of CL. Repairs must be completed by 30 September 2012.
Due 30 September 2012
Resolved 21 February 2013
Construction/Loadline › Hull › Weld
Issued 26 February 2010
Resolved
Provide repair proposals for aft deck plating identified during drydock of March 2010. Enact repairs in accordance with approved repair proposals.
Due 30 September 2010
Resolved 30 September 2011
Construction/Loadline › Hull › Bottom Plating
Issued 26 February 2010
Resolved
Identify source of water intrusion into the port aft corner of the lazarette. Provide repair proposal and encat repairs in accordance with approved proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2010
Resolution: Vessel found and repaired small crack in lazarette IAW NVIC 7-68.
Construction/Loadline › Structures › Door
Issued 26 February 2010
Resolved
Properly repair stbd side galley door coaming.
Due 30 September 2010
Resolved 25 March 2010
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 26 February 2010
Resolved
Repair port propeller (tune, clean, remove debris).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2010
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company has signed up with a consortium. Both the company and consortium receive pre-employment results.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Company did not have records of pre-employments as required by 46 CFR 16.210.
Due 5 July 2008
Resolved 7 October 2009
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR part 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium is currently using a computer based selection program for the company''s random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Company and consortium drafted a list of all safety-sensative personnel to be tested.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP policy posted on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: Consortium provided 2 hours worth of EAP training to company''s supervisors.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employer does not have a Substance Abuse Professional (SAP) name and contact information as required by 49 CFR 40.287.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 5 July 2008
Resolved 25 August 2008
Resolution: EAP hotline phone number posted with EAP policy on all vessels.
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2008
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 5 July 2008
Resolved 3 July 2008
Documentation › Certificates/Documents › FCC SSL
Issued 8 April 2008
Resolved
Provide current FCC Safety License.
Due 8 May 2008
Resolved 17 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 April 2008
Resolved
Provide current first aid kit.
Due 8 May 2008
Resolved 17 April 2008
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 8 April 2008
Resolved
Repair/renew structural fire protection missing in the second deck storage/service closet overhead IAW the original plans.
Due 8 May 2008
Resolved 23 May 2008
Resolution: Corrected deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 8 April 2008
Resolved
Remove old vessel name and properly mark all life jackets with current vessels name.
Due 8 May 2008
Resolved 17 April 2008
Stability › Watertight Integrity › General
Issued 8 April 2008
Resolved
Replace broken window in the scullery on the port side.
Due 8 May 2008
Resolved 17 April 2008
Lifesaving › Lifebuoys › Stowage
Issued 8 April 2008
Resolved
Properly stow, label, and replace retro reflective tape on life buoy that was found in the galley on the deck.
Due 8 May 2008
Resolved 17 April 2008
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 April 2008
Resolved
Provide corrosion resistant clip for ring life buoy lanyard for buoy on upper most deck.
Due 8 May 2008
Resolved 17 April 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 April 2008
Resolved
Properly support electrical wiring in compartment under the pilot house.
Due 8 May 2008
Resolved 17 April 2008
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 8 April 2008
Resolved
Replace missing structural fire protection in storage compartment on bow IAW original plans.
Due 8 May 2008
Resolved 23 May 2008
Resolution: Corrected deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 April 2008
Resolved
Properly support electrical wiring in storage compartment on bow.
Due 8 May 2008
Resolved 23 May 2008
Resolution: Corrected deficiency.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 April 2008
Resolved
Replace current light fixture in storage closet on bow with an approved fixture and materials.
Due 8 May 2008
Resolved 17 April 2008
Engineering › Bilge Water Management System › Interface Detector
Issued 8 April 2008
Resolved
Repair engine room high water alarm visual indicator at the operating station.
Due 8 May 2008
Resolved 17 April 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 April 2008
Resolved
Replace broken window in starboard side door leading to the bow.
Due 8 May 2008
Resolved 17 April 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 8 April 2008
Resolved
Repair exhaust leak on port side main diesel engine turbo.
Due 8 May 2008
Resolved 17 April 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 April 2008
Resolved
Renew/ install lagging on starboard side generator exhaust in engine room.
Due 8 May 2008
Resolved 17 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 8 April 2008
Resolved
Post proper placarding fire fixed fire system pull on the port side main deck.
Due 8 May 2008
Resolved 17 April 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 April 2008
Resolved
Properly service portable extinguishers on board and properly mount IAW 46CFR 181.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2007
Resolved
Install proper wire connections on VHF Marine Radio IAW 46 CFR 120.340.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 7 June 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 May 2007
Resolved
Provide copy of 2006 MIS report.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 May 2007
Resolved
Update coast pilot and light list with latest edition.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 May 2007
Resolved
Install corrosion resistant clip on life ring waterlight.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Stability › Incline Test › General
Issued 1 May 2007
Resolved
Install placard to indicate 204 maximum persons allowed on 01 deck and above.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 1 May 2007
Resolved
Install sea rails on galley stove.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Resolution: operator elected to remove stove since they never used it.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2007
Resolved
Properly wire both refrigerators in wet bar area.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 1 May 2007
Resolved
Repair overhead structural fire protection insulation in the engine room above both main diesel engines.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electric Generation Source (service) › Generator Cable
Issued 1 May 2007
Resolved
Properly install marine grade battery cables on generator and reroute cables to prevent contact with bilge.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 May 2007
Resolved
Repair and make auxiliary generator operational.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 1 May 2007
Resolved
Properly install hose clamps on the fire pump line.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Engineering › Lubricating Oil Service System › Hose
Issued 1 May 2007
Resolved
Replace hydraulic lines on port side engine.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 May 2007
Resolved
Repair exhaust leak in lazarette.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 May 2007
Resolved
Remove oil from engine room bilge.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 May 2007
Resolved
Properly secure electrical panel in galley.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Stability › Weathertight Integrity › General
Issued 1 May 2007
Resolved
Make repairs to window in galley.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2007
Resolved
Properly dead end wires under bridge console.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2007
Resolved
Permanently install PA system with approved wiring in junction boxes.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2007
Resolved
Properly install decorative lighting on 02 deck with approved wiring in junction boxes.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Resolution: Operator elected to remove lighting.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2007
Resolved
Permanently install bilge high level alarm switches with approved wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2007
Resolved 2 May 2007
Resolution: Alarms were permanently affixed to the bilge, and were fitted with approved wiring.
Engineering › Lubricating Oil Service System › Pump
Issued 1 May 2007
Resolved
Repair hydraulic fluid leak for steering pump under bridge console.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 1 May 2007
Resolved
Repair lube oil leak on compressor in pilot house.
Action required: 705 - Other - as specified
Due 31 May 2007
Resolved 7 June 2007
Stability › Watertight Integrity › General
Issued 1 May 2007
Resolved
Prove proper operation of bilge valve in forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2007
Resolved 2 May 2007
Documentation › Certificates/Documents › FCC SSL
Issued 15 March 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 15 April 2006
Resolved 6 April 2006
Electrical › Lighting (service) › Outlet Box
Issued 15 March 2006
Resolved
Replace broken electrical outlet cover in way of 02 deck bar area.
Due 15 April 2006
Resolved 6 April 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 15 March 2006
Resolved
Replace missing voltmeter lense cover in way of port side engine room battery charger.
Due 15 April 2006
Resolved 6 April 2006
Electrical › Electric Supply System (service) › Battery Charger
Issued 15 March 2006
Resolved
Provide plans to replace starboard side battery charger in way of engine room. Charger must be approved for "Marine" use.
Due 14 July 2006
Resolved 2 May 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 March 2006
Resolved
Display Lifesaving donning placard on 01 and 02 decks in vicinity of PFD stowage lockers.
Due 15 April 2006
Resolved 15 March 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 15 March 2006
Resolved
Secure CO2 cylinder in way of 02 deck bar serving area.
Due 15 April 2006
Resolved 15 March 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 15 March 2006
Resolved
Fold back, tape dead ended electrical cable under bridge console in way of the pilot house, port side.
Due 15 April 2006
Resolved 15 March 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 15 March 2006
Resolved
Install missing globe for lighting fixture on starboard side in way of 02 deck dining area.
Due 15 April 2006
Resolved 15 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2006
Resolved
Replace burnt out navigational lights (2) for Mast and Stern Lights.
Due 15 April 2006
Resolved 15 March 2006
Construction/Loadline › Structures › Door
Issued 15 March 2006
Resolved
Replace broken door window, port side 02 deck dining area.
Condition: Improper/Lack of Maintenance
Due 15 April 2006
Resolved 15 March 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 March 2006
Resolved
Install divider between Adult & Child PFD storage locker, port side, 01 deck.
Condition: Improper Installation
Due 15 April 2006
Resolved 15 March 2006
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 15 March 2006
Resolved
Remove all paint thinner and numerous Brasso containers in way of 01 deck storage space.
Due 15 April 2006
Resolved 15 March 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 March 2006
Resolved
Provide Lifesaving Maintenance Records in accordance with 46CFR122.702.
Due 15 April 2006
Resolved 6 April 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 March 2006
Resolved
Provide current Training Logbook in accordance with 46CFR122.420.
Due 15 April 2006
Resolved 6 April 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 March 2006
Resolved
Install missing electrical junction box cover in way of pilot house under console, port side.
Due 15 April 2006
Resolved 6 April 2006
Engineering › Compressed Air System (control) › Valve
Issued 15 March 2006
Resolved
Replace 100 psi relief valve for air horn receiver under pilot house.
Due 15 April 2006
Resolved 6 April 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 22 February 2005
Resolved
Provide plans to repair Starboard rudder assembly as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 February 2005
Resolved
Properly mount bilge high level alarms in way of Aft void and forward mid void.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Stability › Watertight Integrity › General
Issued 22 February 2005
Resolved
Prove watertight integrity in way of forward mid void scuttle gasket.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Stability › Watertight Integrity › General
Issued 22 February 2005
Resolved
Prove watertight integrity in way of forward void scuttle. No gasket or securing device.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Stability › Watertight Integrity › General
Issued 22 February 2005
Resolved
Prove watertight integrity in way of forward peak (focsle) scuttle and remove excess water out of bilge.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 February 2005
Resolved
Remove oil from bilges in way of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2005
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 February 2005
Resolved
Remove excess water from bilge in way of lazarrate
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 February 2005
Resolved
Renew handrail in way of starboard aft fantail.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Construction/Loadline › Structures › Superstructure
Issued 22 February 2005
Resolved
Renew cracked deck support and bulwark in way of focsle just below main deck.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 25 February 2005
Construction/Loadline › Structures › Superstructure
Issued 22 February 2005
Resolved
Renew wasted deck frame support in way of port side focsle marked in yellow.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 25 February 2005
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 22 February 2005
Resolved
Install galley range metallic filter screen IAW 46CFR 121.200.
Action required: 705 - Other - as specified
Due 7 March 2005
Resolved 26 February 2005
Engineering › Steering Gear System › Rudder Bearing
Issued 22 February 2005
Resolved
Repair STBD rudder post/bearings as new.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 18 February 2005
Resolved
Remove orange extension cord from back side of 110 Volt AC receptacle box, for the 02 deck bar cash register, in way of port side PFD locker.
Due 18 March 2005
Resolved 26 February 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 February 2005
Resolved
Replace toilet tank cover in the stbd side fore deck head.
Due 18 March 2005
Resolved 26 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 February 2005
Resolved
Provide label for the fwd peak bilge suction valve in way of fore deck.
Due 18 March 2005
Resolved 26 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 February 2005
Resolved
Remove debris beneath galley ovens.
Due 18 February 2005
Resolved 18 February 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 February 2005
Resolved
Replace the 110 Volt AC receptacle and face plate on the 01 deck dining compartment port side.
Due 18 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 February 2005
Resolved
Provide guard for drive pulleys on #1 Stbd SSDG.
Due 18 March 2005
Resolved 31 March 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 February 2005
Resolved
Permanently mount bilge alarm float switch in way of engine room bilge.
Due 18 March 2005
Resolved 26 February 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 February 2005
Resolved
Investigate and repair machinery exhaust leak in way of lazarette. Upon completion, provide proof of repairs.
Due 18 March 2005
Resolved 26 February 2005
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 18 February 2005
Resolved
Perform hydrostatic test of air horn receiver.
Due 18 March 2005
Resolved 24 March 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 February 2005
Resolved
Provide life jacket donning placard for 01 deck accommodation space
Due 18 February 2005
Resolved 18 February 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 18 February 2005
Resolved
Service BII dry chemical fire extinguisher for 01 deck accommodation space.
Due 18 February 2005
Resolved 18 February 2005
Navigation › Piloting/Steering › Marine Charts
Issued 18 February 2005
Resolved
Provide current edition of navigation charts for routes specified on COI and current local notice to mariners.
Due 18 March 2005
Resolved 26 February 2005
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 18 February 2005
Resolved
Provide 13 child size life jackets for total count of 36, IAW 46 CFR 180.71(b). Vessel limited to carry 23 children until corrected.
Due 18 March 2005
Resolved 24 March 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 18 February 2005
Resolved
Repair fan blades on the 02 deck port side aft accommodation space ceiling fan.
Due 18 February 2005
Resolved 18 February 2005
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 29 November 2004
Resolved
MAKE REPAIRS TO PORT GENERATOR ELECTRICAL WINDINGS, END BELL AND ASSOCIATED WIRING TO MEET MANUFACTURER'S SPECIFICATIONS.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Construction/Loadline › Structures › Superstructure
Issued 29 November 2004
Resolved
RENEW BROKEN WINDOW FORWARD IN WAY OF PILOT HOUSE, STARBOARD SIDE.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 November 2004
Resolved
PROPERLY MOUNT PORTABLE FIRE EXTINGUISHER IAW MANUFACTURER'S INSTRUCTIONS IN WAY OF PILOT HOUSE.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 November 2004
Resolved
LABEL BOTH LIFEBUOYS IN WAY OF PILOT HOUSE WITH VESSEL'S NAME.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 November 2004
Resolved
SECURE ALL PORTABLE FIRE CO2 & NITROGEN CYLINDERS IN WAY OF 3RD DECK BAR AREA.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Documentation › Markings/Placards › Certificate of Number (state)
Issued 29 November 2004
Resolved
REMOVE EXPIRED CG INSPECTION DECALS AND INSTALL NEW (2 EACH) ON WINDOWS.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2004
Resolved
PROVIDE FIRST AID KIT.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 29 November 2004
Resolved
Replace brown "Zip Cord" with marine approved cable in way of battery charger to bilge pump. Ensure bilge pump is using appropriate 12 volt power supply, i.e., battery not battery charger.
Due 29 December 2004
Resolved 5 January 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 29 November 2004
Resolved
Replace brown "Zip Cord" with marine approved cable in way of battery charger to bilge pump. Ensure bilge pump is using appropriate 12 volt power supply, i.e., battery not battery charger.
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 29 November 2004
Engineering › Electric Propulsion System › Measurement Circuitry
Issued 29 November 2004
Resolved
Make repairs to starboard main engine high coolant temperature alarm in way of the pilot house.
Due 29 November 2004
Resolved 29 November 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 25 October 2004
Resolved
Repair and prove proper operation of the starboard main propulsion engine.
Action required: 705 - Other - as specified
Due 25 November 2004
Resolved 29 November 2004
Documentation › Logs/Records › Report of Marine Accident, Injury or Death
Issued 25 October 2004
Resolved
Provide completed report of marine casualty (CG-2692) for starboard engine failure, including the name of the operator, and the date of the failure.
Action required: 705 - Other - as specified
Due 31 October 2004
Resolved 27 October 2004
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 1 October 2004
Resolved
MAKE REPAIRS TO PORT GENERATOR ELECTRICAL WINDINGS, END BELL AND ASSOCIATED WIRING TO MEET MANUFACTURER'S SPECIFICATIONS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 1 October 2004
Resolved
LOAD TEST PORT GENERATOR CIRCUIT BREAKER TO MEET MANUFACTURER'S SPECIFICATIONS; PROVIDE RESULTS TO COAST GUARD PLANNING OFFICE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 6 October 2004
Fire Fighting › Fire Pumps › Pressure
Issued 1 October 2004
Resolved
SHOW PROPER OPERATION OF FIREPUMP, GAUGE, AND HIGHEST HYDRANT IAW 46CFR118.300.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2004
Resolved 2 October 2004
Construction/Loadline › Structures › Superstructure
Issued 1 October 2004
Resolved
RENEW BROKEN FORWARD STARBOARD WINDOWN IN WAY IN THE PILOT HOUSE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 1 October 2004
Resolved
PROPERLY MOUNT PORTABLE FIRE EXTINGUISHER IAW MANUFACTURER'S INSTRUCTIONS IN WAY ON PILOT HOUSE.
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 4 November 2004
Resolution: Extension given until 29NOV04.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 October 2004
Resolved
LABEL BOTH LIFE RING BUOYS IN WAY OF PILOT HOUSE WITH VESSEL'S NAME.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 October 2004
Resolved
RENEW BROKEN LIGHT BULB IN WAY OF 3RD DECK BAR AREA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 1 October 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 1 October 2004
Resolved
SECURE ALL PORTABLE FIRE CO2 & NITROGEN CYLINDERS IN WAY OF 3RD DECK BAR AREA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 October 2004
Resolved
PROVIDE ORIGINAL COD & COI DOCUMENTS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2004
Resolved 1 October 2004
Documentation › Markings/Placards › Certificate of Number (state)
Issued 1 October 2004
Resolved
REMOVE EXPIRED CG INSPECTION DECALS AND INSTALL NEW (2 EACH) ON WINDOWS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 October 2004
Resolved
REPLACE SPENT PORTABLE EXTINGUISHER THAT WAS USED DURING RECENT ELECTRICAL GENERATOR FIRE. PROVIDE ALL REQUIRED PORT. EXTINGUISHERS AS PER COI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2004
Resolved 2 October 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 October 2004
Resolved
PROVIDE FIRST AID KIT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2004
Resolved 1 November 2004
Resolution: Extension given until 29NOV04.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 January 2004
Resolved
Renew gasket for port engine fuel pump to eliminate excessive leakage. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Due 28 February 2004
Resolved 3 February 2004
Resolution: Gasket renewed.
Electrical › Electric Supply System (service)
Issued 29 January 2004
Resolved
Renew 12V DC parallel battery cables (currently using welding cables) with marine grade battery cables for all three starting battery packs. LEGACY COMPONENT DESC: Cable
Due 28 February 2004
Resolved 3 February 2004
Resolution: Battery cables installed.
Engineering › Bilge Water Management System
Issued 29 January 2004
Resolved
Prove proper operation of the engine room high bilge water visual/audible alarm.
Due 28 February 2004
Resolved 29 January 2004
Resolution: Cleared on spot.
Personnel › Training
Issued 28 January 2003
Resolved
Show proof that 50% of vessels required crew are CPR qualified. LEGACY COMPONENT DESC: First Aid/CPR
Due 28 February 2003
Resolved 11 March 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 January 2003
Resolved
Update contents of the vessels first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 28 February 2003
Resolved 7 February 2003
Navigation
Issued 28 January 2003
Resolved
Repair as new stern navigation light (vessel is restricted to daylight hours and periods of unrestricted visability only)
Due 7 February 2003
Resolved 7 February 2003
Accommodation/Occupational Safety › Potable Water System
Issued 28 January 2003
Resolved
Renew hot water heaters pressure/temperature valves using a PT valve of not more than 100psig.
Due 28 February 2003
Resolved 31 January 2003
Electrical › Electrical Distribution System (service)
Issued 28 January 2003
Resolved
Install Blanks in all openings in way of missing breakers on all AC power panels. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 January 2003
Resolved
Relocate the vessel's fire extinguishers in the following manner, provide (1) B-ll for 3rd deck, provide (1) B-ll for 2nd deck on interior, provide (1) B-ll for 1st deck on interior, and provide (1) B-ll for galley.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2003
Resolved 24 June 2003
Communications › Alarms/Indicators
Issued 28 January 2003
Resolved
Install bilge alarms in the following spaces IAW 46 CFR 119.530
A. Both port & stbd shaft wells.
B. #3 and #5 holds. LEGACY COMPONENT DESC: Bilge Alarm
Due 28 February 2003
Resolved 14 August 2003
Resolution: Inspected and tested new alarms.
Accommodation/Occupational Safety › Ventilation
Issued 28 January 2003
Resolved
Install screen on ventilation located in galley.
Condition: Improper/Lack of Maintenance
Due 28 February 2003
Resolved 7 February 2003
Engineering › Shafting/Propeller Arrangements
Issued 28 January 2003
Resolved
Adjust port & stbd shaft packing glands. LEGACY COMPONENT DESC: Stern Gland
Condition: Improper/Lack of Maintenance
Due 28 February 2003
Resolved 11 March 2003
Fire Fighting › Ventilation Systems
Issued 28 January 2003
Resolved
Remove exhaust fan in engine room in way of port side egress. LEGACY COMPONENT DESC: Fans
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2003
Resolved 7 February 2003
Engineering › Diesel Engine (auxiliary)
Issued 28 January 2003
Resolved
Repair as new oil leak on auxilary generator in way of turbo. LEGACY COMPONENT DESC: Turbocharger
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2003
Resolved 7 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 January 2003
Resolved
Repair as new exhaust leak on stbd engine in way of flexible bellows. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2003
Resolved 24 June 2003
Engineering › Diesel Engine (auxiliary)
Issued 28 January 2003
Resolved
Repair as new and show proper operation of the stbd generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 14 August 2003
Resolution: Tested generator, start/stop and under load.
Engineering › Diesel Engine (auxiliary)
Issued 28 January 2003
Resolved
Renew all f/o supply and return lines on port generator IAW 46 CFR 119.710 and SAE J-1942. LEGACY COMPONENT DESC: Distributor (fuel injection)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 24 June 2003
Electrical
Issued 28 January 2003
Resolved
Provide straps for aa eletrical wire found loose or not properly strapped in way of engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 11 March 2003
Electrical › Electrical Distribution System (service)
Issued 28 January 2003
Resolved
Install wire conduit connectors & jam nuts on all AC wiring throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 11 March 2003
Electrical › Electric Generation Source (service)
Issued 28 January 2003
Resolved
Repair as new main conduit & electrical box in way of port generator. LEGACY COMPONENT DESC: Generator Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Fire Fighting › Combustible Materials
Issued 28 January 2003
Resolved
Remove carpet and rubber matting from front of switchboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Fire Fighting › Fire Pumps
Issued 28 January 2003
Resolved
Renew short rubber hose (pedro) on discharge side of fire pump using A-1 or A-2 fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Electrical › Electric Supply System (service)
Issued 28 January 2003
Resolved
Renew battery charger amp meter in way of stbd side battery charger. LEGACY COMPONENT DESC: Battery Charger
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Electrical › Electric Supply System (service)
Issued 28 January 2003
Resolved
Submit proposal and renew all internal combustion battery starting cables using approved marine grade electrical wire. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 14 August 2003
Resolution: Renewed cable using Ancor 2/0 AWG marine grade.
Accommodation/Occupational Safety › Potable Water System
Issued 28 January 2003
Resolved
Renew check valve in way of port side potable water pump.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
Submit proposal to install UL approved bilge pumps with controls and monitoring capabilities at the operating station as required by 46 CFR 119.530. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 14 August 2003
Resolution: Plan approved.
Construction/Loadline › Structures
Issued 28 January 2003
Resolved
Renew forward peak scuttle with hatch that can be operated from above deck. As an interim fix the vessel owner was allowed to swap the deteriorated scuttle with a scuttle from the interior of the vessel. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 29 January 2004
Construction/Loadline › Structures
Issued 28 January 2003
Resolved
Repair as new exterior steel bulkhead to stbd tool locker in way of corrosion. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2004
Resolved 29 January 2004
Lifesaving › Lifejacket/PFD (General)
Issued 28 January 2003
Resolved
Renew retroreflective tape on 257 adult & 19 child PFDs. vessel is restricted to no more than 106 adult & 17 child passengers until this requirement is satisfied. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 11 March 2003
Lifesaving › Lifebuoys
Issued 28 January 2003
Resolved
renew lifering buoy light. Vessel is restricted to daylight operations only until this requirement is satisfied. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Fire Fighting › Fire Pumps
Issued 28 January 2003
Resolved
Provide pressure guage in way of discharge side of port fire pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 7 February 2003
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
Relocate bilge pump strainer in lazarette. LEGACY COMPONENT DESC: Strainer
Due 31 January 2003
Resolved 31 January 2003
Resolution: Bilge pump strainer placed in proper position.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 January 2003
Resolved
Provide proper electrical connection in way of fuel solenoid on port MDE.
Due 31 January 2003
Resolved 31 January 2003
Resolution: O/O replaced faulty electrical connection with acceptable connector.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 January 2003
Resolved
Reroute fuel supply line away from port MDE starter solenoid.
Due 31 January 2003
Resolved 31 January 2003
Resolution: Fuel supply to port MDE rerouted away from starter.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 January 2003
Resolved
Provide as original crank case vent tube in way of stbd MDE.
Due 31 January 2003
Resolved 31 January 2003
Resolution: Vent tube installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 January 2003
Resolved
Provide proper electrical connection in way of engineroom bilge alarm float switch wiring.
Due 31 January 2003
Resolved 31 January 2003
Resolution: O/O replaced improper connector with acceptable replacement.
Operations/Management › Drills/Instruction
Issued 23 January 2002
Resolved
Properly log crew training and drills IAW 46 CFR 122.420.
Due 23 January 2002
Resolved 23 January 2002
Stability › Watertight Integrity
Issued 23 January 2002
Resolved
Install retaining device on all void hatch covers (five). IAW 46 CFR 116.1160 (b).
Due 23 January 2002
Resolved 23 January 2002
Documentation › Markings/Placards › Capacity Marking
Issued 23 January 2002
Resolved
Mark upper most deck with maximum occupancy (100). IAW Stability letter.
Due 23 January 2002
Resolved 23 January 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 January 2002
Resolved
Replace damaged and worn retroreflective tape on lifejackets. IAW 46 CFR 122.604 (h) LEGACY COMPONENT DESC: Marking
Due 23 January 2002
Resolved 23 January 2002
Engineering › Bilge Water Management System
Issued 23 January 2002
Resolved
Label reach rod to forpeak bilge suction valve. IAW 46 CFR 56.50 (g)(2)(i) LEGACY COMPONENT DESC: Valve
Due 23 January 2002
Resolved 23 January 2002
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 23 January 2002
Resolved
Adjust port and starboard shaft packing for proper flow.
Due 23 January 2002
Resolved 23 January 2002
Electrical › Lighting (service)
Issued 23 January 2002
Resolved
Replace Starboard navigation light bulb. IAW 46 CFR 120.420
Due 23 January 2002
Resolved 23 January 2002
Electrical › Lighting (service)
Issued 23 January 2002
Resolved
Install Bulb, Globe and cage, on forward deck light. IAW 46 CFR 120.410
Due 23 January 2002
Resolved 23 January 2002
Fire Fighting
Issued 25 January 2001
Resolved
CONDUCT ANNUAL SERVICE ON FIXED FIREFIGHTING CO2 SYSTEM.
Condition: Unknown
Due 26 January 2001
Resolved 9 February 2001
Construction/Loadline
Issued 25 January 2001
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN ENGINE ROOM AND AUDIBLE/VISUAL ALARM IN PILOT HOUSE/OPERATING STATION.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Construction/Loadline
Issued 25 January 2001
Resolved
REPAIR FOREPEAK BILGE SUCTION PIPING AND REACH ROD. ENSURE PROPER OPERATION.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Navigation
Issued 16 June 1998
Resolved
REPAIR STEERING EQUIPMENT
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Electrical
Issued 29 January 1998
Resolved
PROVIDE DRIPSHIELD AND ADEQUATE HAND RAIL FOR SWITCHBOARD IN THE ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 January 1998
Resolved 29 January 1998
Construction/Loadline
Issued 21 March 1997
Resolved
PROVE PROPER OPERATION OF THE VESSEL'S BILGE PUMPING SYSTEMS IAW 46 CFR 115.804.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROVIDE AND INSTALL SHUTOFF VALVES WHERE COOLER PIPING PENETRATES THE SIDE/BOTTOM SHELL IAW 46 CFR 119.422(b).
Condition: Unknown
Due 25 June 1997
Resolved 19 May 1997
Engineering
Issued 21 March 1997
Resolved
RENEW EXHAUST BLANKETS/LAGGING IAW 46 CFR 116.970.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 21 March 1997
Resolved
HAVE LIFERAFT SERVICED AT AN APPROVED SERVICING FACILITY IAW 46 CFR 117.175
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 21 March 1997
Resolved
RENEW EXPIRED HYDRO-STATIC RELEASE ON LIFERAFT IAW 46 CFR 117.150.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW PORTSIDE AFT FUEL TANK GOOSE NECK VENT IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROPERLY REPAIR HOLE ABOVE THIRD PORTSIDE MAINDECK SUPERSTRUCTURE WINDOW IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT WASTED TRANSOM IWO THE #5 VOID STBD SIDE IAW COST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
REMOVE SIX DOUBLER PLATES ON THE PORT SIDE SHELL IN THE #5 VOID AND PROPERLY INSERT IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW BUCKELED GOOSE NECK VENT LOCATED ON THE PORT SIDE MAINDECK IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Deck/Cargo
Issued 21 March 1997
Resolved
CROP AND RENEW FOURTH PORTSIDE BOW CLEAT AS ORIGINAL IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
RENEW ALL EXHUAST BLANKETS/LAGGING ON ALL DRY EXHAUST PIPING WITHIH THE #5 VOID IAW 46 CFR 116.970.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROPERLY COMPLETE A FULL PENETRATE WELD ON THE MAINDECK INSERT PORT OF THE CENTER LINE IN THE #5 VOID IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
REMOVE TEMPORARY FUEL TANK FILLS AND PROPERLY INSERT MAIN DECK IWO VOID'S 3AND 4 IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Electrical
Issued 21 March 1997
Resolved
MAKE PROPER REPAIRS TO THE 110V LIGHTING SYSTEM THROUGH-OUT THE VESSEL IAW 46 CFR 183.10-20.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Navigation
Issued 21 March 1997
Resolved
PROVE PROPER OPERATION OF THE BRIDGE NAVIGATIONAL SYSTEMS INCLUDING NAVIGATION LIGHTS AND STEERING IAW 46 CFR 115.814 AND 115.816.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
ENSURE THAT ALL WATERTIGHT SUBDIVISION BULKHEADS ARE WATERTIGHT IAW 46 CFR 171.070 THROUGH 171.073.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROVIDE AND PROPERLY INSTALL GASKETS ON ALL MAINDECK WATERTIGHT HATCHES IAW46 CFR 116.1160.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
U/T GAUGING INDICATED SERIOUS WASTAGE ON 98% OF THE BOTTOM PLATE. THE BOTTOM PLATE WAS RENEWED AS ORIGINAL W/THE EXCEPTION OF THE PLATE LOCATED BETWEEN THE PROP SHAFTS WHICH WAS LOWERED IAW APPROVED PLANS. ALL RENEWED HULL PLATING WAS HOSE OR AIR TESTED PRIOR TO THE END OF THE INSPECT
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
THE PLATE IN WAY OF THE SIDE SHELL MAIN ENGINE AND GENERATOR COOLERS WAS WASTED AND HOLED. ALL OF THE SIDE SHELL PLATE WAS RENEWED IWO THE COOLERS ON BOTH THE PORT AND STBD SIDES. PLATE RENEWAL WAS AIR AND WATER TESTED PRIOR TO THE END OF THE INSPECTION. ALL RENEWED PLATE WAS .25" STEEL.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW BENT LONGITUDINAL AND TRANSVERSE BOTTOM/KEEL FRAMING IN FOREPEAK IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
REPAIR OR RENEW FOREPEAK BILGE VALVE REACH ROD AND PROVE PROPER OPERATION IAW 46 CFR 182.25-5 (d).
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW SQUARE INSERT ON MAIN DECK IN THE #1 VOID IAW COAST GUARD NVIC 7-68. INSERT DID NOT HAVE RADIUS CORNERS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT HOLED PORT AND STBD SIDE SHELL LOCATED IN THE #1 VOID IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
THE UNDER SIDE OF THE MAIN DECK IWO THE FORWARD KING POST WAS NOT WELDED AND DID NOT APPEAR TO BE A FULL PENETRATE WELD. PROPERLY PREPARE AND WELD IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW TWO TRIPPED TRANSVERSE FRAMES LOCATED WITHIN THE FUEL TANK AT THE CENTERLINE IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
REPAIR OR RENEW SOUNDING TUBE BRACKETS WERE FRACTURED AND PROPERLY WELD TOPS OF THE SOUNDING TUBES IN THE FUEL TANK IAW APPROVED PLANS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
RENEW MISSING AND DAMAGED FUEL TANK MANHOLE COVER STUDS. TANK WAS AIR TESTED WITH NO LEAKS PRIOR TO THE END OF THE INSPECTION.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPELY INSERT 18"X24" WASTED PORT AND STBD SIDE SHELL LOCATED IN THE #2 VOID IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT #2 VOID AFT WATERTIGHT BULKHEAD IWO THE FUEL PIPING PENETRATION WERE WASTED AND THE LADDER WERE BUCKLED IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FUEL SHUT OFF VALVES LOCATED WITHINTHE #3 VOID IAW 46 CFR 182.20-40 (b)(3).
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT BUCKLED #3 VOID AFT WATERTIGHT BULKHEAD STBD SIDE IAW COAT GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT BUCKLED #4 VOID FORWARD PORT WATERTIGHT BULKHEAD IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT 18"X24" PORT AND STBD WASTED SIDE SHELL LOCATED WITHIH THE #4 VOID IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPELY INSERT WASTED MAINDECK IWO THE #4 VOID STBD SIDE AND PROPERLY PREPARE AND COMPLETE FULL PENETRATION WELDS ON ALL EXISITING MAINDECK INSERTS IN THE SAME SPACE IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT #4 VOID WASTED STBD FORWARD WATERTIGHT BULKHEAD IWO PENETRATIONS IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND PROPERLY INSERT PORT SIDE #4 VOID MAINDECK IWO THE CHILL WATER PIPING IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
RENEW ALL WASTED STBD SIDE SHELL IWO THE #4 VOID AS ORIGINAL IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
REWELD INSUFFICIENT WELDS IWO BEVERAGE LINE CONDUIT AND CROP/PROPERLY INSERT BUCKLED PORT AFT WATERTIGHT BULKHEAD LOCATED IN VOID #4 IAW COAT GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Engineering
Issued 21 March 1997
Resolved
PROVIDE AND PROPERLY INSTALL FUEL SHUT OFF VALVES SO AS TO CLOSE AGAINST THE FUEL FLOW, FITTED AT THE ENGINE END OF THE FUEL LINE TO STOP FUEL FLOW WHEN SERVICING ACCESSORIES IAW 46 CFR 182-20-40 (b)(3) ON ALL MAIN ENGINES AND GENERATOR PRIME MOVERS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Electrical
Issued 21 March 1997
Resolved
RENEW ENGINE ROOM BATTERY BOX IAW 46 CFR 120.350.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Accommodation/Occupational Safety
Issued 21 March 1997
Resolved
CROP AND RENEW WASTED HAND RAILING ON SECOND AND THIRD DECKS IAW 46 CFR 116.900 (d) AND COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Fire Fighting
Issued 21 March 1997
Resolved
SUBMITT STRUCTURAL FIRE PROTECTION DETAILS AND FIRE LOAD CALCULATION PLANS FOR VESSEL MODIFICATIONS ie:GALLEY AND HEADS TO MSC WASHINGTON VIA COGNIZANT [name withheld] 46 CFR 116.202(b)(2) & (3).
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROVIDE A REPAIR PROPOSAL FOR THE MAIN DECK, WERE WASTED IWO BOTH THE PORT AND STBD PADDLE WHEEL MOUNTINGS AND APPROXIMATELY 20 FEET FORWARD.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Electrical
Issued 21 March 1997
Resolved
REMOVE ALL WIRENUTS FROM THE ELECTRICAL SYSTEMS THROUGHOUT THE VESSEL IAW 46 CFR 183.05-50(2)/120.340(g) AND (h).
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Engineering
Issued 21 March 1997
Resolved
RENEW GENERATOR EXHAUST BLANKETS/LAGGING IAW 46 CFR 116.970.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROVIDE AND INSTALL CHECK VALVES ON ALL BILGE LINES IAW 46 CFR 182.25-5(c).
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROPERLY REPAIR PORT OUTBOARD STANTION AT THE MAIN DECK ON THE FIFTH STANTION FROM THE SECOND DECK MAIN TRANSVERSE BEAM DOWN TO THE MAIN DECK IAW COAST GUARD NVIC 7-68._x001C_ X
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Engineering
Issued 21 March 1997
Resolved
PROVIDE AND INSTALL 30X30 MESH SCREENS ON ALL FUEL TANK AND MSD TANK VENTS IAW 46 CFR 119.450(d) AND 33 CFR 159.95 (a)(2).
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Engineering
Issued 21 March 1997
Resolved
PROVE PROPER OPERATION OF THE PILOT HOUSE MAIN ENGINE CONTROLS AND SERVICE GENERATORS IAW 46 CFR 115.804, 115.808 AND 115.816.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROPERLY INSTALL FLANGE PLATES ON ENGINE ROOM MAINDECK ACCESS PANELS AND PROVE THAT ACCESSES MEET THE REQUIREMENTS FOR A-60 DECKS IAW 46 CFR 116.415.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 21 March 1997
Resolved
BOTH THE PORT AND STBD MAIN DECK TO SUPERSTRUCTURE CONNECTION WAS WASTED ALLOWING FLOODING OF THE INTERIOR SPACES. SUPERSTUCTURE PLATE WAS RENEWED FROM THE MAINDECK UP TO THE WINDOW BOTTOMS ON BOTH THE PORT AND STBD SIDES AFT THO THE LAST WINDOW.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 March 1997
Resolved
CROP AND RENEW WASTED #3 VOID SIDE SHELL ON BOTH THE PORT AND STBD SIDES IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Electrical
Issued 21 March 1997
Resolved
PROVIDE AND PROPERLY INSTALL A WX TIGHT FITTING ON CONDUIT ABOVE SHORETIE POWER PLUG LOCATED ON THE MAINDECK PORTSIDE IAW 46 CFR 183.10-20 (
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Electrical
Issued 21 March 1997
Resolved
PROVIDE DOCUMENTATION THAT BOTH SERVICE GENERATORS RATED AT 40 DEGREES C AMBIENT AIR TEMP ARE DERATED IAW 46 CFR 183.10-5 (f)/120.320 (b)(1) AND PROVIDE AND POST A PLACARD IAW 46 CFR 183.10-5 (f)(2)/120.320(d).
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Electrical
Issued 21 March 1997
Resolved
PROVIDE AND INSTALL METAL WIRE RUN CLAMPS ON ALL OVERHEAD WIRE RUNS IAW 46 CFR 120.340 (d)(4).
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROPERLY WELD INSERT IN MAIN DECK ABOVE MSD TANK IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Electrical
Issued 21 March 1997
Resolved
PROVIDE DOCUMENTATION THAT THE INSTALLED BATTERY CHARGER MEETS THE REQUIREMENTS OF 46 CFR 120.350.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Lifesaving
Issued 21 March 1997
Resolved
CONDUCT AS REQUIRED BY THE COGNIZANT OCMI A DEADWEIGHT SURVEY OR STABILITY TEST IAW 46 CFR 170.175, 170.180 AND 170.185.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Accommodation/Occupational Safety
Issued 21 March 1997
Resolved
RENEW MAIN DECK A-60 INSULATION IN ENGINE ROOM.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Lifesaving
Issued 21 March 1997
Resolved
PROPERLY INSTALL RETRO-REFLECTIVE TAPE ON ALL LIFERING BUOYS IAW 46 CFR 122.604(i).
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 21 March 1997
Resolved
EVALUATE AND PROVIDE A REPAIR PROPOSAL FOR THE SUPERSTRUCTURE/MAIN DECK CONNECTION ON BOTH THE PORT AND STBD SIDES IWO GALLEY IAW COAST GUARD NVIC 7-68.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Fire Fighting
Issued 21 March 1997
Resolved
PROPERLY REINSTALL FIXED CO2 FIRE FIGHTING SYSTEM IN THE ENGINE ROOM IAW 46CFR 118.400.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Construction/Loadline
Issued 21 March 1997
Resolved
PROVIDE A REPAIR PROPOSAL TO REMOVE IMPROPER INSERTS ON THE SUPERSTRUCTURE AND PROPELY RENEW.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Navigation
Issued 21 March 1997
Resolved
REMOVE TEMPORARY WIRING TO THE STERN NAVIGATION LIGHT IAW 46 CFR 120.340.
Condition: Unknown
Due 21 March 1997
Resolved 21 March 1997
Lifesaving
Issued 23 February 1996
Resolved
WORK LIST ITEM #9: PROVIDE 13 ADULT AND 04 CHILD PFD'S TO SATISFY FULL NUMBER OF PFD'S REQUIRED BY COI.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 23 February 1996
Resolved
WORK LIST ITEM #1: REPAIR/REPLACE BROKEN LIGHT FIXTURE MAIN DECK FORWARD PORT SIDE. SAFETY HAZARD DUE TO SHARP GLASS EDGES.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 23 February 1996
Resolved
WORK LIST ITEM #5: REPLACE BURNED OUT EMERGENCY LIGHT, 3RD DECK PASSENGER AREA.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 23 February 1996
Resolved
WORK LIST ITEM #6: CLEAN/REMOVE/REPLACE OIL-SOAKED LAGGING ABOVE STBD MAINENGINE.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 23 February 1996
Resolved
WORK LIST ITEM #7: PROPERLY REPAIR POWER SUPPLY FEEDER CABLE TO PORT SIDE MACHINERY SPACE TO PREVENT CHAFING AND SHOCK HAZARD.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Navigation
Issued 23 February 1996
Resolved
WORK LIST ITEM #8: REPAIR OR REPLACE NAVIGATIONAL RUNNING LIGHTS TO BRING INTO COMPLIANCE WITH COLREGS VERTICAL SECTOR HEIGHTS.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 23 February 1996
Resolved
CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN 01 JUN 96.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Fire Fighting
Issued 23 February 1996
Resolved
WORK LIST ITEM #10: DEMONSTRATE SATISFACTORY OPERATION OF ENGINE ROOM EXHAUST FAN SHUT DOWN BY MANUALLY ACTUATING SHUT DOWN SWITCH TO FIXED CO2 SYSTEM.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Construction/Loadline
Issued 23 February 1996
Resolved
WORK LIST ITEM #2: DEMONSTRATE SATISFACTORY OPERATION OF BILGE PUMP BY DEWATERING FORWARD COMPARTMENT OF EXCESS WATER.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 23 February 1996
Resolved
WORK LIST ITEM #3: PROPERLY SERVICE BII FIRE EXTINGUISHER, PORT SIDE MACHINERY SPACE.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 23 February 1996
Resolved
WORK LIST ITEM #4: PROPERLY LABEL PFD STORAGE BOX, STARBOARD SIDE, UPPER DECK.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 8 February 1995
Resolved
PROPERLY LABEL "PULL STATION" LOCATED IN GALLEY FOR MACHINERY SPACE FIXED CO2 FIREFIGHTING SYSTEM.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Engineering
Issued 8 February 1995
Resolved
INSTALL CAP/PLUG TO FUEL OIL TANK DRAIN VALVE.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Electrical
Issued 8 February 1995
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF BACK-UP GENERATOR. VOLTAGE REGULATORBOARD NEEDS REPLACING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Fire Fighting
Issued 8 February 1995
Resolved
HYDROSTATICALLY TEST FIXED CO2 CYLINDERS FOR ENGINEROOM SYSTEM.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Lifesaving
Issued 8 February 1995
Resolved
CONDUCT UNDERWAY DRILLS NO LATER THAN 08MAR95
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Lifesaving
Issued 8 February 1994
Resolved
PROVIDE 8 ADDITIONAL ADULT LIFE PRESERVERS NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Lifesaving
Issued 8 February 1994
Resolved
CONDUCT SATISFACTORY UNDERWAY MAN OVERBOARD DRILL, NO LATER THAN COMPLIANCEDATE._x001C_
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Electrical
Issued 12 February 1993
Resolved
REPLACE 20-AMP LIGHTING CIRCUIT BREAKER IN GALLEY WITH 15-AMP CAPACITY BREAKER NOT LATER THAN THE COMPLIANCE DATE. _x001C_ _x001C_ 46 CFR 183.10-35 (d)
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Electrical
Issued 12 February 1993
Resolved
RECONNECT AND DEMONSTRATE SATISFACTORY OPERATION OF MAIN GENERATOR ALARM SYSTEM NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Lifesaving
Issued 10 February 1992
Resolved
RENEW TWO LIFE RING BUOYS WHICH HAVE ROTTED GRAB LINES, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 March 1992
Resolved 13 February 1992
Construction/Loadline
Issued 10 February 1992
Resolved
MAKE PERMANENT REPAIRS TO WASTED DECK IN AIR COMPRESSOR COMPARTMENT, STARBOARD SIDE, MAIN DECK, NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Electrical
Issued 10 February 1992
Resolved
REPAIR OR REPLACE DAMAGED, PORT MAIN DIESEL ENGINE, STARTING BATTERY NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Electrical
Issued 10 February 1992
Resolved
REPAIR FUEL LEAK ON AUXILIARY GENERATOR ENGINE FUEL INJECTOR PUMP PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 March 1992
Resolved 13 February 1992
Construction/Loadline
Issued 10 February 1992
Resolved
MAKE PERMANENT REPAIRS (BY WELDING) TO TWO ONE-FOURTH INCH DRILL HOLES IN THE AFT TRANSVERSE WATERTIGHT BULKHEAD OF THE NUMBER 5 VOID COMPARTMENT NOTLATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Construction/Loadline
Issued 10 February 1992
Resolved
REMOVE DEBRIS, EXTRANEOUS MATERIAL AND ACCUMULATED SCALE FROM BILGES IN NOS. 5 AND 7 VOID COMPARTMENTS NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Electrical
Issued 10 February 1992
Resolved
REPLACE INCORRECT (VOLTAGE) BULBS IN EMERGENCY LIGHTING SYSTEM AND ENSURE SYSTEM OPERATES SATISFACTORILY PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 10 March 1992
Resolved 13 February 1992
Navigation
Issued 11 February 1991
Resolved
PROPERLY TIGHTEN PORT AND STARBOARD REMOTE STEERING STATION CHAIN DRIVE ASSEMBLIES PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Lifesaving
Issued 11 February 1991
Resolved
REPLACE 24 ADULT AND 5 CHILDS LIFE PRESERVERS, OR PROVE DAMAGED PFD's CAN PASS REQUIRED BUOYANCY TEST PRIOR TO CARRYING MORE THAN 376 PASSENGERS, BUTNOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Engineering
Issued 11 February 1991
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF MSD AIR COMPRESSOR UNIT BY THE COMPLIANCE DATE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Electrical
Issued 11 February 1991
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF ENGINE ROOM EMERGENCY LIGHT FIXTURE BY THE COMPLIANCE DATE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Engineering
Issued 11 February 1991
Resolved
PROPERLY SECURE PORT MAIN ENGINE COOLING PIPE TO PREVENT RUBBING ON ENGINE FLYWHEEL PRIOR TO ENGINE OPERATION BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Construction/Loadline
Issued 29 January 1991
Resolved
REPAINT DRAFT MARKS PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
CROP AND RENEW WASTED SIDE PLATE FROM STEM TO AFT OF FRAME NUMBER THREE PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Engineering
Issued 29 January 1991
Resolved
PROPERLY REPOSITION AND SECURE BILGE SUCTION STRAINER IN NUMBER TWO VOID COMPARTMENT AND CLEAN SCALE AND DEBRIS FROM BILGE PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
CROP AND RENEW AREA OF SET-UP BULKHEAD LOCATED AT AFT STARBOARD CORNER OF NUMBER FOUR VOID COMPARTMENT ADJACENT TO BOTTOM AND SIDE PLATE, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
PLUG AND MAKE WATERTIGHT SIX HOLES IN NUMBER FOUR VOID COMPARTMENT AFT WATERTIGHT BULKHEAD PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
CROP AND RENEW AREA OF SET-UP BULKHEAD LOCATED AT FORWARD PORT CORNER OF THE ENGINE ROOM, ADJACENT TO BOTTOM AND SIDE PLATE, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Navigation
Issued 29 January 1991
Resolved
RENEW UPPER PORT AND STARBOARD RUDDER SHAFT BUSHINGS, AND REBUILD BOTH RUDDER SHAFT BEARING SURFACES TO ORIGINAL DIAMETER PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Navigation
Issued 29 January 1991
Resolved
REMOVE ALL SCALE AND DEBRIS FROM LAZARETTE BILGE PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Electrical
Issued 29 January 1991
Resolved
SECURE LOOSE ELECTRIC WIRING AND TERMINATE ENDS IN JUNCTION BOX, OR REMOVE SAME FROM LAZARETTE PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Engineering
Issued 29 January 1991
Resolved
REMOVE UNUSED SEA VALVES FROM PORT AND STARBOARD SEACHESTS AND CAP OR PLUG OPENING AS APPROPRIATE, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
PLUG AND MAKE WATERTIGHT ALL HOLES AND ELECTRIC WIRE STUFFING TUBES IN AFT ENGINE ROOM BULKHEAD PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE._x001C_
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 29 January 1991
Resolved
CROP AND RENEW EIGHT (MARKED) OF ELEVEN WASTED BOTTOM LONGS ADJACENT TO LAZARETTE FORWARD BULKHEAD, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Engineering
Issued 29 January 1991
Resolved
REPOSITION LAZARETTE BILGE SUCTION STRAINER TO EFFECT PROPER COMPARTMENT DEWATERING, PRIOR TO CARRYING PASSENGERS, BUT NOT LATER THAN THE COMPLIANCEDATE.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Lifesaving
Issued 7 February 1990
Resolved
PROVIDE 38 APPROVED ADULT LIFE PRESERVERS AND 4 APPROVED CHILD LIFE PRESERVERS PRIOR TO THE COMPLIANCE DATE. TOTAL PERSONS ABOARD IS RESTRICTEDTO 349 WITH NO MORE THAN 36 CHILDREN UNTIL LIFE PRESERVERS ARE ON BOARD.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Lifesaving
Issued 7 February 1990
Resolved
DEMONSTRATE A FIRE AND MAN OVERBOARD DRILL TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR PRIOR TO OPERATING THE VESSEL BUT NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Electrical
Issued 7 February 1990
Resolved
PROVIDE BLANK COVERS FOR ALL OPEN SPACES IN VESSEL CIRCUIT BREAKER PANEL BOXES, TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 7 February 1990
Resolved 7 February 1990
Deck/Cargo
Issued 10 March 1989
Resolved
RAISE STAGE PLATFORM AND REMOVE HINGE BOLTS FOR VISUAL INSPECTION OF THE BOLTS AND MAIN SWIVEL PIN. THIS IS TO BE COMPLETED TO THE SATISFACTION OF THE OMCI PRIOR TO 10 APRIL, 1989.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Electrical
Issued 23 February 1988
Resolved
PROVIDE WARNING SIGNS FOR ELECTRICAL BOXES THAT ARE PROVIDED WITH MORE THANONE SOURCE OF ELECTRICAL POWER.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Construction/Loadline
Issued 23 February 1988
Resolved
PROVIDE SEPARATE SOURCES OF POWER FOR THE BILGE PUMPS.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Electrical
Issued 23 February 1988
Resolved
PROVIDE GLOBES FOR ALL DECORATIVE LIGHTS.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 2 April 1987
Resolved
PROVIDE A PROPER MARINE BRACKET FOR THE FIRE EXTINGUISHER ON THE 2ND DECK PORT SIDE.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Construction/Loadline
Issued 2 April 1987
Resolved
REPLACE THE ALLEN SOCKET FOR THE REACH ROD ON THE BILGE PIPING VALVE ON THE BOW VOID.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Electrical
Issued 2 April 1987
Resolved
PLACE THE DEAD END WIRES IN THE AUXILIARY MACHINERY SPACE IN A JUNCTION BOXOR REMOVE THE CABLE FROM THE SOURCE OF POWER
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Unknown
Issued 2 April 1987
Resolved
INSTALL GUARDS ON ALL BELTS AND PULLEYS IN THE ENGINE ROOM.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Engineering
Issued 2 April 1987
Resolved
CLEAN AND RELINE THE BATTERY BOXES FOR THE MAIN ENGINE STARTING BATTERIES AND CHOCK THE BATTERIES FIRMLY INTO POSITION.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Construction/Loadline
Issued 2 April 1987
Resolved
REWORK AS NECESSARY TO ACCOMMODATE A FULL STREAM OF WATER THE OVERBOARD DISCHARGE FOR THE BILGE PUMP OVERBOARD DISCHARGE ON THE PORT SIDE.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Electrical
Issued 2 April 1987
Resolved
REPLACE THE "SHORE POWER AVAILABLE" BULB ON THE ELECTRICAL SWITCHBOARD IN THE ENGINE ROOM.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Fire Fighting
Issued 2 April 1987
Resolved
CARRY ON BOARD THE VESSEL TWO PORTABLE FIRE/BILGE PUMPS UNTIL THE FIXED FIRE/BILGE PUMPS ARE TESTED AND PROVEN TO OPERATE SATISFACTORILY.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Lifesaving
Issued 4 April 1986
Resolved
THE VESSEL IS RESTRICTED TO THE CARRIAGE OF 396 ADULTS UNTIL THE FOUR (04) ADDITIONAL LIFE JACKETS ARE INSPECTED, STAMPED, AND PLACED ON BOARD THE VESSEL.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
MAKE OPERABLE THE PILOT HOUSE SHUTDOWN FOR THE PORT GENERATOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
SWITCH THE ALARM LIGHT FOR THE STARBOARD GENERATOR FROM THE FUEL OIL SYSTEMTO THE LUBE OIL SYSTEM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
COMPLETE THE BULKHEAD REPAIRS AT THE VENT FORWARD OF THE MEN'S BATHROOM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 6 May 1985
Resolved
RENEW THE FLAME SCREEN ON BOTH FUEL OIL TANK VENTS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE RESTRAINTS TO PREVENT THE GLOBES ON THE LIGHTING SYSTEM ON THE SECOND LEVEL PASSENGER SPACES FROM FALLING.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE GLOBES FOR EXTERIOR DECORATIVE LIGHTING; REPLACING ALL BROKEN GLOBES. THIS ITEM IS TO BE CORRECTED PRIOR TO OPERATING THESE ELECTRICAL FIXTURES.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Navigation
Issued 6 March 1985
Resolved
REWORK THE RUDDER STOPS ON BOTH THE PORT AND STARBOARD SWING TO PREVENT THE STEERING SYSTEM FROM TWO BLOCKING ON THE CABLE CLAMPS.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 6 March 1985
Resolved
PROPERLY MARK THE VESSEL'S HULL IN ACCORDANCE WITH 46 CFR 67.15-1.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Accommodation/Occupational Safety
Issued 6 March 1985
Resolved
RECONNECT THE SEWAGE LINE FROM THE MEN'S RESTROOM TO THE SEWAGE TREATMENT AND PROVIDE PROPER TREATMENT FOR THE SEWAGE SYSTEM. THIS ITEM IS TO BE CORRECTED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Accommodation/Occupational Safety
Issued 6 March 1985
Resolved
CONNECT THE URINAL DRAIN LINE IN THE MEN'S RESTROOM TO THE SEWAGE SYSTEM.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Navigation
Issued 6 March 1985
Resolved
REPLACE THE COTTER PIN FOR THE DROP PIN IN THE STEERING SYSTEM IN THE STARBOARD SIDE. THIS ITEM IS TO BE COMPLETED PRIOR TO OPERATING THE VES- SEL.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PRIOR TO PLACING IN SERVICE AND FOLLOWING ITS COMPLETE INSTALLATION AND HOOKUP, PROVIDE FOR A COAST GUARD INSPECTION OF THE 80 KW GENERATOR AND ASSOCIATED, NEWLY-INSTALLED ELECTRICAL DEVICES.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
RELINE BOTH BATTERY BOXES IN THE ENGINE ROOM, COVERING MOUNTING BOLTS AND SEALING ALL LEAKS.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
BOLT THE 80 KW GENERATOR TO SUPPORT FRAMING. THIS ITEM IS TO BE CORRECTED PRIOR TO OPERATING THE UNIT.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROPERLY BOLT DOWN THE 30 KW GENERATOR; REPLACE MISSING BOLTS AND TIGHTEN LOOSE BOLTS AS NECESSARY. THIS ITEM IS TO BE CORRECTED PRIOR TO OPERATING THE GENERATOR.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE GUARDS FOR THE PULLIES ON THE FRONT END OF BOTH GENERATORS.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 6 March 1985
Resolved
REPLACE THE STRAINERS ON BILGE SUCTION LINES AS NECESSARY. THIS ITEM IS TOBE CORRECTED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Engineering
Issued 6 March 1985
Resolved
REMOVE OIL CONTAINED BY THE FRAMING AND SUPPORTS FOR THE PROPULSION ENGINESAND CLEAN ALL OIL FROM THE ENGINE ROOM DECKS. THIS ITEM IS TO BE CORRECTEDPRIOR TO OPERATING THE ENGINES.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
REPLACE THE POWER AVAILABLE LIGHTS ON THE GENERATOR CONTROL PANEL. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Fire Fighting
Issued 6 March 1985
Resolved
PROVIDE A PROPER HAND-OPERATED FIRE PUMP IN ACCORDANCE WITH 46 CFR 181.10- 05. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Fire Fighting
Issued 6 March 1985
Resolved
MAKE REPAIRS AS NECESSARY TO THE STARBOARD MAIN ENGINE FIRE/BILGE PUMP TO BRING IT TO ITS PROPER PUMPING RATE. THIS ITEM IS TO BE CORRECTED PRIOR TOPLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Unknown
Issued 6 March 1985
Resolved
HYDRO TEST BOTH AIR RECEIVERS AT 1-1/4 TIMES WORKING PRESSURE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 6 March 1985
Resolved
PROVIDE PROTECTION FOR THE HULL PENETRATION FOR THE FATHOMETER AFTER SUB- MITTING PLANS FOR APPROVAL.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Unknown
Issued 6 March 1985
Resolved
REMOVE ALL CARPET FROM THE ENGINE ROOM. THIS ITEM IS TO BE CORRECTED PRIORTO OPERATING THE VESSEL.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE CLIPS FOR THE NEWLY-INSTALLED RECESSED LIGHTING JUST FORWARD OF THEBAR.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
REPLACE THE RENEWABLE TYPE FUSES IN THE HEATING SYSTEM PANEL WITH PROPER FUSES. THIS ITEM IS TO BE CORRECTED PRIOR TO OPERATING APPLICABLE ELEC- TRICAL SYSTEM.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985
Resolved
PROVIDE PROPER NUMBER AND TYPE OF LIFE RINGS IN ORDER TO COMPLY WITH 46 CFR180.30. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING THE VESSEL IN SER- VICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Fire Fighting
Issued 6 March 1985
Resolved
PROVIDE A FIRE EXTINGUISHER FOR THE FIRE STATION ON THE SECOND LEVEL. THISITEM IS TO BE CORRECTED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROPERLY SPLICE THE WIRE LEAD TO THE SPEAKER ON THE FRONT OF THE PILOT HOUSE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985
Resolved
PROPERLY MARK ALL LIFE JACKET STOWAGE LOCKERS. THIS ITEM IS TO BE COR- RECTED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 6 March 1985
Resolved
ADEQUATELY PROTECT THE HULL PENETRATIONS FOR THE KEEL COOLERS WHERE THEY ARE GASKETED AND BOLTED TO THE HULL AFTER SUBMITTING PLANS FOR APPROVAL.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 18 December 1984
Resolved
MAKE PERMANENT REPAIRS TO THE THROUGH HULL FITTING FOR THE STBD SHAFT VENT,MAINTAINING TEMPORARY REPAIRS.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984