Inspection history · 21
7 May 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8368056
18 September 2025
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8227839
2 January 2025
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8043664
17 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7896690
8 November 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7821993
20 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7611258
18 October 2022
Annual Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7578995
22 July 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7513732
24 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7294373
3 December 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7105759
19 November 2020
Hull Examination · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7097856
7 October 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7072659
21 September 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7059968
18 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6815832
8 July 2019
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6742394
19 September 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6544190
15 August 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6750749
19 September 2017
Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6270335
8 August 2017
Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6234376
2 August 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5990220
18 July 2016
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5945599
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 September 2025
Resolved
Fire pump was inoperable due to worn short-run flexible hose on the fire main. Demonstrate proper operation of fire pump prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Flexible hose was replaced. Proper operation and pressure was observed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 18 September 2025
Resolved
Higher than usual water level noticed in the forepeak and lazarette space due to faulty watertight hatch covers. Replace/repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2025
Resolved 30 September 2025
Resolution: Forepeak hatch was repaired and lazarette hatch was replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 November 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in the lazarette. The water alarm was inop on the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 29 November 2023
Resolution: Alarm is now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2023
Resolved
Electrical equipment must be installed and maintained to provide services necessary for the safety under normal conditions. Three out of five lights were inop in the ER
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 29 November 2023
Resolution: Lights are now operable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2023
Resolved
Each lifering must be marked with the vessel's name in clearly legible block capital letters. The lifering near the bridge's starboard entrance is missing the vessel's name.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 29 November 2023
Resolution: Lifering is properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2023
Resolved
Exhaust gas must not leak from the piping or any connections. There was an exhaust leak in the lazarette.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2023
Resolved 29 November 2023
Resolution: Exhaust silencer was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 October 2022
Resolved
The vessel had a SART EPIRB mounted on the bridge (for the life raft). This was mounted within one meter of the compass which according to placard and manufacturers guidance could affect compass. Issued requirement to move it further than one meter away.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2022
Resolved 20 October 2022
Resolution: Moved.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 October 2022
Resolved
Vessels EPIRB hydrostatic release had expired. Vessel limited to 3nm until replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 20 October 2022
Resolution: Had one on order. Replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 October 2022
Resolved
STBD side MDE vent closure would not move. Issued requirement to fix it.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2022
Resolved 20 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 October 2022
Resolved
The required spanner wrench was not in the vicinity of the fire hose connection and was not immediately available. Issued requirement to secure a spanner wrench at the connection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2022
Resolved 18 October 2022
Resolution: Fixed on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 August 2021
Resolved
Replace gasket in WTD to accomodations.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 25 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 24 August 2021
Resolved
Replace light fixture in shower space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2021
Resolved 25 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 24 August 2021
Resolved
Provide a means to secure oven door
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 25 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2020
Resolved
Missed dry dock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020
Resolved 19 November 2020
Resolution: Dry dock exam completed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 September 2020
Resolved
Provide flame inpingement bowl for generator fuel filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2020
Resolved 25 September 2020
Resolution: New flame bowl installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2020
Resolved
Prove proper operation of fixed fire fighting manual override device.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2020
Resolved 25 September 2020
Resolution: Fixed fire fighting override tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 21 September 2020
Resolved
Prove proper operation of port navigation light.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2020
Resolved 25 September 2020
Resolution: New navigation lights installed and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 September 2020
Resolved
The man overboard "Jasons Cradle" does not reach the water. Adjust and prove proper operation of cradle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2020
Resolved 25 September 2020
Resolution: Jasons cradle strap was renewed and is now the proper length.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2018
Resolved
Install junction box IWO operating station in pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2018
Resolved 24 September 2018
Resolution: Junction box installed.
Engineering › Bilge Water Management System › Valve
Issued 18 July 2016
Resolved
Secure reach rod to forepeak bilge shut off valve.
Due 25 July 2016
Resolved 19 September 2016
Resolution: Reach rod secured.
Engineering › Steering Gear System › Ram
Issued 18 July 2016
Resolved
Repair excessive play and movement in steering ram/hull connection and yoke/tiller connection.
Due 18 August 2016
Resolved 30 August 2016
Resolution: Steering system rebuilt at yard period. Steering tested satisfactorily.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 July 2016
Resolved
Provide eyewash for first aid kit.
Due 18 August 2016
Resolved 30 August 2016
Resolution: Eyewash provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 July 2016
Resolved
Provide updated FCC Safety Radio Certificate.
Due 18 August 2016
Resolved 30 August 2016
Resolution: Safety radio certificate updated.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 18 July 2016
Resolved
Repair generator tachometer in wheelhouse.
Due 19 August 2016
Resolved 30 August 2016
Resolution: Tach repaired.
Stability › Watertight Integrity › General
Issued 18 July 2016
Resolved
Plug holes in aft cargo deck.
Due 18 August 2016
Resolved 30 August 2016
Resolution: Holes plugged.