NYACK BOAT CLUB II

NYACK BOAT CLUB II is a 1997 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1997, most recently in May 2026, along with 43 deficiencies.

Records from 1997 to 2026. Most recent: inspection, 14 May 2026.

Built
1997
Last inspected
14 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

456577
Flag
UNITED STATES
—
Maury page id
psix-456577

Inspections, by type

…with no type recorded1
Years with a record 24 calendar years (1997–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

14 May 2026 Drydock Exam · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8359160
25 June 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8166883
28 May 2024 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7918465
21 June 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7719668
28 June 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489413
23 May 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7458159
23 May 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7458178
21 May 2021 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7200845
18 June 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973981
20 February 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912389
29 May 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915446
17 May 2018 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6416597
23 May 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6153620
25 May 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5886191
25 May 2016 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5886196
20 August 2015 DAPI Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5227956
20 May 2014 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4866321
6 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4202761
22 April 2009 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458002
28 April 2006 COI Inspection · Hull Examination · MARPOL Annex V Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2637747
1 November 2005 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2521946
8 November 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2236811
22 June 2004 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2106532
28 October 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1937390
15 November 2002 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1706123
13 November 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1706131
15 October 2001 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397746
21 August 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071918
5 October 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195727
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1123251
30 November 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805330
17 September 1998 COI Inspection · Plan Review "T" Boat
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1364868
2 September 1998 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 797850
29 April 1997 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1091437

Deficiency record · 43

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed active leak on the shaft seal. Repair shaft seal to the satisfaction of OCMI. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Tested main and brought up RPMs, no leak found
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 May 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed active leak on upper bearing of rudder post post vessel was maneuvering. Repair bearing on rudder post to the satisfaction of OCMI. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Tested steering with new bearing, no leak found
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 May 2026 Resolved
Vessel must carry adequate and up-to-date: charts of large enough scale to make safe navigation possible; U. S. Coast Pilot or similar publication, Coast Guard Light List, Tide Tables; and Current Tables. Operator could not provide charts or publications. Provide charts and publications to the satisfaction of MI.46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 1 June 2026
Resolution: Operator provided photo of charts and pubs.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 May 2026 Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Operator posted outdated stability letter on vessel. Provide updated stability letter and post as practicable. 46 CFR 176.306
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 1 June 2026
Resolution: Operator sent photo of stability letter page 2 which has been laminated with a sticky backing so it can adhere to the launch.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Operator could not provide alcohol testing devices. Provide alcohol testing devices onboard or in office.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 1 June 2026
Resolution: Operator sent photo of alcohol swabs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2026 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Operator could not provide servicing for pre-engineered fixed gas fire extinguishing system. Provide servicing report for pre-engineered fixed gas fire extinguishing system. 46 CFR 176.810(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 28 May 2026
Resolution: Operator provided service report letter. MI called Rockland Fire and Safety Co. INC to confirm inspection on May 7, 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2026 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI observed degraded placards for donning life jackets. Replace placards for donning life jackets. 46 CFR 185.516(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2026
Resolved 3 June 2026
Resolution: Operator sent photo of new placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 June 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MIs observed multiple items in the first-aid kit were expired. Replace all expired first-aid items within one week. 46 CFR 184.710
Action required: 705 - Other - as specified
Resolved 31 July 2025
Resolution: Vessel sent email showing def cleared, see documents tab to see def correspondence.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 June 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MIs observed the vessel only had 2 buckets on board and they were only 2 gallons. Replace all buckets with the right size and number of buckets within one week.
Action required: 705 - Other - as specified
Resolved 31 July 2025
Resolution: Vessel sent email showing def cleared, see documents tab to see def correspondence.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 28 May 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: (1) Be approved by the Commandant; (2) Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector; (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and (4) Be installed in accordance with the manufacturer's instructions. (b) A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Vessel's pre engineered system has a independent toggle switch spliced in to overide function and does not have an audible alarm when it is actviated.
Action required: 705 - Other - as specified
Due 28 May 2024
Resolved 1 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 May 2021 Resolved
Vessel completed a repower prior to inspection, fill out the attached word document and return to the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2021 Resolved
Ring life buoy grablines were wasted, purchase and install a new ring life buoy approved in accordance with 46 CFR 160.050.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2021 Resolved
Bilge pump indicator light was inoperable, complete repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 May 2021 Resolved
Forward masthead light housing was cracked, install new housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2021 Resolved
Electrical wiring in forepeak obstructed lifejacket access, mount electrical wiring to forepeak overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2018 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space. Engine did not shut down during simulated activation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: Proved proper operation of system via operational test.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 May 2018 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions.
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 1 June 2018
Resolution: Posted Emergency Instructions.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 23 May 2017 Resolved
Provide means to demonstrate emergency steering.
Condition: Improper/Lack of Maintenance
Due 30 May 2017
Resolved 12 June 2017
Resolution: Tiller installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 May 2016 Resolved
SH01: Provide new first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 26 May 2016
Resolution: Provided new first aid kit.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 May 2016 Resolved
SH02: Prove proper operation of Fireboy System.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2016
Resolved 26 May 2016
Resolution: Proved proper operation of Fireboy System.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2016 Resolved
SH03: Post copy of COI on boat, visible to passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Posted COI.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 25 May 2016 Resolved
SH04: Provide Coast Pilot [name withheld], and up to date chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Provided new coast pilot, light list & up to date chart for area.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2016 Resolved
SH05: Organize forward life jacket storage area.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Organized forward life jacket storage area.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 25 May 2016 Resolved
SH06: Provide CAPT license, unable to get underway for drills.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 8 June 2016
Resolution: Provided captain's license.
Documentation › Certificates/Documents › Stability Letter
Issued 6 December 2011 Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum persons allowed to 21 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Action required: 705 - Other - as specified
Resolved 5 April 2012
Resolution: Owner/operator submitted letter requesting Weight Ratio method to reduce passenger count. Issued an addendum to the Stability Letter which reduces passenger count in compliance with 185 lb AAWPP.
Engineering › Bilge Water Management System › Hose
Issued 22 April 2009 Resolved
Renew red bilge pump hose line.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 27 May 2009
Resolution: Received signed letter attesting to repair.
Engineering › Bilge Water Management System › Not Operational
Issued 22 April 2009 Resolved
Properly rewire white bilge pump.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 27 May 2009
Resolution: Received signed letter attesting to repair.
Engineering › Steering Gear System › Follow-up Assembly
Issued 22 April 2009 Resolved
Provide emergency steering tiller.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 27 May 2009
Resolution: Received signed letter attesting to a quick release pin being provided for vessel''s steering arm.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 April 2006 Resolved
Make repairs to secondary bilge suction system that is presently not electrically connected to system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 30 March 2008
Resolution: Deficiencies were cleared on 13 Nov 06.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 April 2006 Resolved
Make necessary repairs to bilge high level system in order to have visual indication of high water level in bilge at the operating station.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 30 April 2008
Resolution: Deficiencies were cleared on 13 Nov 06.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 April 2006 Resolved
Renew name of vessel on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 30 April 2008
Resolution: Deficiencies were cleared on 13 Nov 06.
Lifesaving
Issued 15 October 2001 Resolved
Provide first aid kit that complies with 46 CFR 160.041.
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Documentation
Issued 15 October 2001 Resolved
Provide proof of supervisory training (60 min).
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Lifesaving
Issued 15 October 2001 Resolved
Post lifejacket donning placard.
Condition: Unknown
Due 29 October 2001
Resolved 6 November 2001
Documentation
Issued 5 October 1999 Resolved
Provide a vessel log book, ensure training, safety equipment checks and passenger counts get logged, Provide faxed copy of receipt to clear.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Engineering
Issued 5 October 1999 Resolved
Prove proper operation of the emergency fuel shut off valve. Fax copy of the work order from marina.
Condition: Unknown
Due 1 November 1999
Resolved 1 November 1999
Documentation
Issued 17 September 1998 Resolved
Provide proof of vessel being operated by a licensed master. Vessel restricted from operating with passengers until cleared.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Lifesaving
Issued 17 September 1998 Resolved
Provide Type II retroreflective tape for ring buoy.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Documentation
Issued 17 September 1998 Resolved
Provide plan to OCMI for compliance with chemical testing program. Vessel restricted from operating with passengers until cleared.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Documentation
Issued 17 September 1998 Resolved
Provide Oil Pollution placard for vessel.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Documentation
Issued 17 September 1998 Resolved
Provide 46 CFR subchapter T and Rules of the Road handbook.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Fire Fighting
Issued 17 September 1998 Resolved
Provide proof of servicing for fire extinguishing equipment.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Unknown
Issued 29 April 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING REQUIREMENTS.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.