Documentation record
Registered dimensions (L × B × D)61.7 ft × 30.4 ft × 6.1 ft
Registered tonnagegross 67 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN RI, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portALGONAC, MI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 2 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
23 September 2025
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8238654
3 October 2024
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8013156
19 September 2023
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7794288
20 September 2022
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7562936
15 September 2022
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7559335
14 October 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7332368
7 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7073026
16 October 2019
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6836392
21 February 2019
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6629609
20 September 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6545109
5 April 2018
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6385842
23 March 2018
Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6380469
3 January 2018
Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6332073
20 September 2017
COI Inspection · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6240077
7 July 2017
Excursion Permit
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6200904
7 June 2016
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5902068
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2021
Resolved
The owner/operator shall instruct each crew member at least once every three months as to the duties they are expected to perform in an emergency. Vessel crew needs familiarization training on bilge pumping arrangement and use of foam eductor, as they were unsure of use/set-up.
CITE
46 CFR 185.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 1 November 2021
Resolution: Use of the foam applicator has been incorporated into the training program for the crew.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 October 2021
Resolved
Foam eductor threads were worn and could not connect to hose. Renew/replace and test to satisfaction of local marine inspector.
CITE
49 CFR 176.315
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 1 November 2021
Resolution: The nozzle on board the North channel had different threads, owner ordered an adaptor and placed it in service on the vessel. Owner also verified the other vessels did not require an adaptor.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 October 2021
Resolved
At every vessel inspection the bilges and other spaces, see there is no excessive accumulation of oil that might create a fire hazard. Found oil misted throughout engine space. Clean oil.
CITE
46 CFR 176.830(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 1 November 2021
Resolution: Engine room has been cleaned
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 October 2021
Resolved
Found alcohol swabs were expired in Aug 2021. Company has new swabs on order. Upon delivery, provide evidence to satisfaction of local marine inspector.
CITE
46 CFR 185.212
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 3 November 2021
Resolution: Received email photo of new alcohol test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 October 2020
Resolved
THE BILGE SUCTIONS SHALL BE FITTED WITH SUITABLE STRAINERS HAVING AN OPEN AREA NOT LESS THAN 3X THE AREA OF THE BILGE PIPE. NO STRAINER WAS FOUND ON EITHER BILGE SUCTION IN THE ENGINE ROOM.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 30 October 2020
Resolution: Received pictures via email showing installation of strainers on the bilge suction lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 October 2020
Resolved
AN ADULT LIFEJACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD A VESSEL. ONE LIFE JACKET WAS FOUND TO HAVE DETERIORATED FOAM. LIFEJACKET WAS DESTROYED AND IMMEDIATELY REPLACED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 October 2020
Resolution: Cleared on the spot
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 September 2018
Resolved
Vessel shall keep an accurate passenger count on shore for each voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 17 October 2019
Resolution: The vessel has agreed to keep a passenger count and call it in to a voice recording system prior to each voyage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2018
Resolved
Vessels name needs to be in block letters on lifebouy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 29 October 2018
Resolution: Exemption given to company.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2018
Resolved
Water light on/for lifebouy shall be attached with a 3' lanyard with quick disconnect.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 29 October 2018
Resolution: Water light was installed in the correct location.
Construction/Loadline › Hull › Side Shell
Issued 20 September 2017
Resolved
MAKE PERMANENT REPAIRS TO TWO 1" APPOX. HOLES WITHIN THE STARBOARD MAINLAND SIDE PEAK AND #2 WITHIN BEHIND THE RUBRAIL NEAR TRANS BULKHEAD BY CROP AND RENEWAL TO GOOD STEEL.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 17 October 2019
Resolution: This deficiency was rectified before the vessel went back into the water after drydock inspection. New steel was put in place and drainage holes were installed in rubrail to avoid future corrosion.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 June 2016
Resolved
Seperate childrens and adult pfds.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2016
Resolved 7 June 2016
Resolution: Jackets properly stowed.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 June 2016
Resolved
Clean, make appropriate repairs to retroflective material on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 June 2016
Resolved 7 June 2016
Resolution: New retroflective tape added to 12 floatation devices.