MAURY USCG vessel records Sign in
← All vessels

MATT KAHEALANI

MATT KAHEALANI is a 1959 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1984, most recently in January 2026, along with 38 deficiencies and 1 casualty investigation in 2006.

Records from 1984 to 2026. Most recent: inspection, 29 January 2026.

Built
1959
Last inspected
29 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45669

Inspections, by type

…with no type recorded3
Years with a record 38 calendar years (1984–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.1 ft × 3.0 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WAILUA KAUAI, HI, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWAILUA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 58

29 January 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8303582
16 February 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8084031
26 August 2024 In-Service Inspection · Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7991552
3 April 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7889640
7 November 2023 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7821052
10 October 2022 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7574729
14 October 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7333216
25 March 2021 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7189492
22 September 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7063266
16 October 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6836048
29 October 2018 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6570736
14 March 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6372092
29 September 2017 COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6278139
3 November 2016 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6147919
3 November 2015 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5756558
29 October 2014 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5014548
9 December 2010 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3907830
7 July 2008 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3282265
6 December 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3112967
17 May 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3001056
30 October 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2795427
27 March 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2610461
18 August 2005 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2501490
18 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2247000
6 August 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2158148
16 October 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929231
16 December 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1724710
13 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1702818
17 July 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1644972
29 October 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1075854
25 September 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391689
17 October 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446998
13 October 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361163
15 July 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416935
7 October 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364896
16 October 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381031
11 September 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363789
11 July 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407717
27 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357527
12 October 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367534
10 November 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382868
29 September 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356847
10 February 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 856426
13 January 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358277
9 July 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415828
15 December 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1142090
10 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961161
15 January 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1269498
26 September 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230745
27 July 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 918954
8 November 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1349954
25 October 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889378
5 November 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331336
10 April 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022099
12 November 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1325533
20 November 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301517
7 November 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994025
18 December 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976780

Deficiency record · 38

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2024 Resolved
Vessel is overdue for it triennial hull exam. Provide vessel for DryDock inspection. Vessel may not carry passengers until credit DryDock is received by attending MI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2024
Resolved 26 August 2024
Resolution: Drydock completed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 October 2018 Resolved
Vessel 26' or greater in length must be equipped with an audible and visual bilge high water alarm at the operating station. At the time of the inspection the vessels visual high water alarm was inoperable. Provide a visual high water alarm.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2018
Resolved 7 November 2018
Resolution: Proper audible and visual alarms were provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2018 Resolved
Ring buoys are required to be fitted with retro reflective tape affixed to the buoy. The provided buoy did not have any retro attached. Provide the required retro.
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 29 October 2018
Resolution: Deficiency corrected prior to inspection ending.
Construction/Loadline › Hull › Hull Plating
Issued 29 October 2014 Resolved
Numerous areas of wooden hull plating were found rotted during haul out. Owner to submit repair proposal to replace all rotted wood plating during this haul out.
Action required: 705 - Other - as specified
Due 1 May 2015
Resolved 6 March 2015
Resolution: All rotted hull plating was cropped out and replaced with new material. All items found sat.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 6 December 2007 Resolved
Provide flame screen for fuel vent.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 6 December 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 6 December 2007 Resolved
Provide (1) B-1 portable extinguisher prior to carrying passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 6 December 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 18 August 2005 Resolved
Provide high water alarm for barge.
Condition: Unknown
Due 22 September 2005
Resolved 22 September 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 13 November 2002 Resolved
Install bridge windows IAW 46CFR177.1010 LEGACY COMPONENT DESC: Safety Glass
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Lifesaving › Lifebuoys
Issued 13 November 2002 Resolved
Renew ring lifebuoy due to wasted grab line. LEGACY COMPONENT DESC: Grab Line
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 November 2002 Resolved
Provide First Aid Kit LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Engineering › Reduction Gearing/Clutches
Issued 13 November 2002 Resolved
Install retainer at reduction gear linkage. LEGACY COMPONENT DESC: Linkage
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Engineering › Bilge Water Management System › Pump
Issued 13 November 2002 Resolved
Provide portable bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 13 November 2002
Resolution: Corrected on the spot.
Communications › Alarms/Indicators
Issued 13 November 2002 Resolved
Provide bilge high level alarms IAW 46CFR182.530 LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2002 Resolved
Renew retro-reflective tape on all lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2002 Resolved
Renew 16 adult lifejackets, due to worn straps. Reduced passenger count by 16 until lifejackets are renewed. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2002 Resolved
Label lifejacket storage locker IAW 46CFR180.78. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Lifesaving
Issued 25 September 2001 Resolved
Provide a properly equipped ring life buoy with working water light on a 3-6' lanyard with proper clip and 60' of line spliced to ring buoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 2 October 2001
Resolved 7 November 2001
Lifesaving
Issued 25 September 2001 Resolved
Prove recent CPR/1st Aid training for minimum of 50% of vessel crew in accordance with NVIC 1-91.
Condition: Unknown
Due 25 October 2001
Resolved 7 November 2001
Engineering
Issued 25 September 2001 Resolved
Provide a fuel tank fill/vent system that does not require a can to catch fuel overflow when fueling vessel. Provide in accordance with 46 CFR 176.804.
Condition: Unknown
Due 25 October 2001
Resolved 7 November 2001
Lifesaving
Issued 13 October 1999 Resolved
Replace triangular bandage in 1st Aid kit. Replace other items to conform with 46CFR 160.041.
Condition: Unknown
Due 12 November 1999
Resolved 26 November 1999
Electrical
Issued 27 March 1996 Resolved
Provide portable lights IAW 46 CFR 183.420.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training emergencydrills.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.520, abandon ship and man overboard drills and training.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills and training; logged.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Fire Fighting
Issued 27 March 1996 Resolved
Label location of portable fire extinguisher adjacent to the steering station.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Lifesaving
Issued 27 March 1996 Resolved
Prove operation of the waterlight.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Engineering
Issued 29 September 1994 Resolved
PROVIDE PROPER OIL CONTAINMENT AROUND THE FUEL VENT, FUEL INTAKE, AND ALL HYDRAULIC STEERING RAMS ON THE PUSHER UNIT.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Engineering
Issued 13 January 1994 Resolved
REPLACE THE MISSING FLAME SCREEN ON THE FUEL TANK VENT.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Construction/Loadline
Issued 13 January 1994 Resolved
INSTALL A FIXED POWER BILGE PUMP AS SPECIFIED IN 46 CFR TABLE 182.25-10(a)
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Construction/Loadline
Issued 9 July 1993 Resolved
RENEW ALL FASTENERS ON PORT SIDESHELL OF PUSHER UNIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
CROP AND RENEW, APPROXIMATELY THREE FEET OF LOWER, PORT SIDESHELL, ALONG THE ENTIRE LENGTH OF PUSHER UNIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
MAKE PERMANENT REPAIRS TO ENTIRE MAIN DECK OF PUSHER UNIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
CROP AND RENEW DELAMINATED SECTION OF BOTTOM PLATING ON BOW OF PUSHER UNIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
CROP AND RENEW APPROXIMATELY 2.5X5.0 FOOT SECTION OF DELAMINATED BOTTOM PLATING ON STARBOARD SIDE OF PUSHER UNIT.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 10 November 1992 Resolved
MOUNT THE EMERGENCY FUEL SHUTOFF VALVE DIRECTLY ON THE FUEL TANK DISCHARGE AND MAKE IT OPERABLE FROM OUTSIDE THE FUEL TANK SPACE.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Engineering
Issued 27 July 1990 Resolved
DEMONSTRATE SATISFACTORY MACHINERY OPERATION OF THE PUSHER UNIT.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Electrical
Issued 7 November 1985 Resolved
REPLACE SPOTLIGHT STARBOARD SIDE FORWARD OUTSIDE OPERATOR'S CONSOLE.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985

Casualty record · 1

27 March 2006Routine · role: Involved in a Marine Casualty · activity 2610461
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.