Records from 2016 to 2025. Most recent: inspection, 26 August 2025.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 20.4 ft × 3.0 ft
Registered tonnagegross 33 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWAILUA KAUAI, HI, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWAILUA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
26 August 2025
Vessel Attendance · Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8231948
23 October 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8024488
27 June 2024
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7985063
8 March 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879133
12 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666970
9 February 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396225
30 October 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087407
21 July 2020
Damage Survey · COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012324
3 April 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6655365
5 July 2018
Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6468189
29 December 2016
Hull Examination · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6066462
22 August 2016
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5981234
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel pusher sunk while vessel was tied to dock. All machinery and electronics in engine room were submerged in brackish water. Make engine room available for inspection and complete testing of all engineering systems once repairs have been made. Vessel restricted from operations.
46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2025
Resolution: All systems tested and sea trial conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 June 2024
Resolved
All vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1)
(b)(1)-Annual inspection, Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
25MAR2021 was RONNIE K's issued date of its COI. The annual drop dead date was 26JUN2024. The vessel has been out of compliance for over a overdue annaul inspection. The vessel shall not carry passengers until an inspection is complete to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 23 October 2024
Resolution: Annual inspection completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 April 2023
Resolved
Vessel's L/O pressure gauge is inoperable. Provide capable gauge to read engine oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 24 May 2023
Resolution: Vessel installed new oil pressure gauge. Gauge is now capable of reading engine oil pressure.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 July 2018
Resolved
Portable fire protection systems are required to be inspected IAW NFPA 10. The provided portable extinguishers had not been inspected by a certified person. Provide proof of isnpection by a certified person.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 11 July 2018
Resolution: Vessel rep provided proof of annual inspection by a certified person.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2018
Resolved
The vessel is required to carry 13 child sized life jackets on board. The vessel only had 4 available. Provide the required number of life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 10 July 2018
Resolution: New child sized life jackets were provided bringing the total on board to 13.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 July 2018
Resolved
The hull, superstructures and decks will be inspected for soundness at each subsequent inspetion for certification. The deck area around the STBD engine room hatch was found to be soft, rotted and cracked. Provide a repair to support the deck in way of the STBD engine room hatch.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2018
Resolved 12 July 2018
Resolution: The decking and supporting structures in way of the STBD engine room hatch were renewed IAW exisiting plans.
Construction/Loadline › Hull › Hull Plating
Issued 29 December 2016
Resolved
Found rotted wood on Port FWD hull areas. Issued requirement to crop out and renew all rotted wood and structures found.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 May 2017
Resolution: All rotted hull plating was cropped out and replaced in kind. All items found sat.