MAURY USCG vessel records Sign in
← All vessels

RONNIE K

RONNIE K is a 1967 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1985, most recently in August 2025, along with 49 deficiencies.

Records from 1985 to 2025. Most recent: inspection, 26 August 2025.

Built
1967
Last inspected
26 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45670

Inspections, by type

…with no type recorded2
Years with a record 33 calendar years (1985–2025)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 20.4 ft × 3.0 ft
Registered tonnagegross 33 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WAILUA KAUAI, HI, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWAILUA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

26 August 2025 Vessel Attendance · Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8231948
23 October 2024 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8024488
27 June 2024 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7985063
8 March 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7879133
12 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7666970
9 February 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396225
30 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087407
21 July 2020 Damage Survey · COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012324
3 April 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6655365
5 July 2018 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6468189
29 December 2016 Hull Examination · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6066462
22 August 2016 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5981234
6 January 2012 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4220161
15 December 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3380343
16 October 2007 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3081104
16 May 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3001058
14 August 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2739269
16 August 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2436031
19 January 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2270977
18 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2247045
16 September 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929271
16 December 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1724698
12 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1702809
28 August 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1071420
20 August 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1468241
13 September 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822792
3 August 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381990
12 August 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361076
15 July 1998 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372311
20 August 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1400633
16 August 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353992
10 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431617
27 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357529
17 August 1995 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358884
15 June 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357036
8 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1470900
29 September 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414372
6 September 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417685
13 August 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1408998
12 August 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937747
14 February 1992 Deficiency Check · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1245050
6 September 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 959503
6 September 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1243630
5 November 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1222899
26 September 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230746
8 September 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037793
12 September 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213647
26 April 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1194915
29 July 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028296
20 August 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1296420
20 August 1985 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1293564
20 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978563

Deficiency record · 49

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2025 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel pusher sunk while vessel was tied to dock. All machinery and electronics in engine room were submerged in brackish water. Make engine room available for inspection and complete testing of all engineering systems once repairs have been made. Vessel restricted from operations. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2025
Resolution: All systems tested and sea trial conducted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 June 2024 Resolved
All vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) (b)(1)-Annual inspection, Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. 25MAR2021 was RONNIE K's issued date of its COI. The annual drop dead date was 26JUN2024. The vessel has been out of compliance for over a overdue annaul inspection. The vessel shall not carry passengers until an inspection is complete to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 23 October 2024
Resolution: Annual inspection completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 April 2023 Resolved
Vessel's L/O pressure gauge is inoperable. Provide capable gauge to read engine oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 24 May 2023
Resolution: Vessel installed new oil pressure gauge. Gauge is now capable of reading engine oil pressure.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 July 2018 Resolved
Portable fire protection systems are required to be inspected IAW NFPA 10. The provided portable extinguishers had not been inspected by a certified person. Provide proof of isnpection by a certified person.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 11 July 2018
Resolution: Vessel rep provided proof of annual inspection by a certified person.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 July 2018 Resolved
The vessel is required to carry 13 child sized life jackets on board. The vessel only had 4 available. Provide the required number of life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 10 July 2018
Resolution: New child sized life jackets were provided bringing the total on board to 13.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 July 2018 Resolved
The hull, superstructures and decks will be inspected for soundness at each subsequent inspetion for certification. The deck area around the STBD engine room hatch was found to be soft, rotted and cracked. Provide a repair to support the deck in way of the STBD engine room hatch.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2018
Resolved 12 July 2018
Resolution: The decking and supporting structures in way of the STBD engine room hatch were renewed IAW exisiting plans.
Construction/Loadline › Hull › Hull Plating
Issued 29 December 2016 Resolved
Found rotted wood on Port FWD hull areas. Issued requirement to crop out and renew all rotted wood and structures found.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 May 2017
Resolution: All rotted hull plating was cropped out and replaced in kind. All items found sat.
Engineering › Bilge Water Management System › Valve
Issued 16 October 2007 Resolved
Remove S/W supply line for examination prior to end of dry-dock exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2007
Resolved 6 December 2007
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2007 Resolved
Crop and renew bow section.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 22 February 2008
Construction/Loadline › Hull › Hull Plating
Issued 16 October 2007 Resolved
Crop and renew bottom plate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 22 February 2008
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 16 August 2005 Resolved
Provide battery box covers.
Condition: Unknown
Due 31 August 2005
Resolved 31 August 2005
Construction/Loadline › Structures › Deck Plating
Issued 16 August 2005 Resolved
Renew wasted connection plate between pusher and barge.
Condition: Unknown
Due 31 August 2005
Resolved 15 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 August 2005 Resolved
Provide lagging for generator exhaust.
Condition: Design Flaw
Due 31 August 2005
Resolved 15 August 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 August 2005 Resolved
Provide protective machinery guards.
Condition: Unknown
Due 31 August 2005
Resolved 15 August 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 August 2005 Resolved
Provide proper fuel oines and fittings IAW 46CFR182.720(e).
Condition: Improper Installation
Due 31 August 2005
Resolved 15 August 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 August 2005 Resolved
Provide CFR's applicable to fleet, 46CFR subchapter T 166-199, subchapter F, subchapter J and subchapter A 1-40.
Condition: Improper/Lack of Maintenance
Due 31 August 2005
Resolved 15 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 November 2004 Resolved
Provide metal fasteners for electrical wire runs located in pusher boat.
Condition: Unknown
Due 30 November 2004
Resolved 25 April 2005
Engineering › Fuel Oil Service System › Tank
Issued 18 November 2004 Resolved
Provide grounding strap for fuel tank.
Due 30 November 2004
Resolved 25 April 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 November 2002 Resolved
Provide asprin, burn spray and eye dressing for first aid kit. (Items missing or out of date) LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 12 November 2002 Resolved
Renew retro-reflective material on all lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2002
Resolved 16 December 2002
Lifesaving › Lifebuoys
Issued 12 November 2002 Resolved
Renew ring lifebuoy due to worn grab line. LEGACY COMPONENT DESC: Grab Line
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Submit plan proposal for repair of all areas in need of repair. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. submitted plan for repair.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair approx. one inch hole on stbd quarter approx. 15ft. 7in. from stern and 5in. from chine. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired hole with crop and renew as per plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area stbd amidship on bottom hull 15ft. 6in. from stern and 8ft. 3in. from stbd side 10in. long by 1in. wide. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired according submitted plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area amid ship on bottom hull in keel area 26ft. 6in. from stern and 10ft. from stbd side. (1) Rotted area approx. 2in. hole, (2) Rotted area approx. 1in. hole. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired in accordance with submitted plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area on port side forward quarter 4ft. 8in. form upper bow and 10.5in. from chine approx. 1in. hole. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired in accordance with submitted plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area on port upper corner on bow of pusher. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired in accordance with submitted plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area on stbd quarter of pusher 6ft. 1in. from upper aft most stern, 27in. from chine approx. 1in. hole. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired in accordance with submitted plan.
Construction/Loadline › Hull
Issued 28 August 2001 Resolved
Repair rotted area on stbd side on bottom hull 38in. from lower bow rake approx. 1in. hole. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 28 August 2001
Resolved 29 October 2001
Resolution: Rep. repaired in accordance with submitted plan.
Construction/Loadline
Issued 3 August 2000 Resolved
Provide additional length of hose to portable bilge pump to permit de- watering to overboard from any compartment on vessel IAW 46CFR 182.520(b).
Condition: Unknown
Due 15 September 2000
Resolved 1 September 2000
Lifesaving
Issued 20 August 1997 Resolved
PROPERLY ATTACH THE WATER LIGHT TO THE RING LIFE BOUY AS OUTLINED IN 46 CFR180.70(D)(2).
Condition: Unknown
Due 20 August 1997
Resolved 2 September 1997
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training emergencydrills.
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.520, abandon ship and man overboard drills and training.
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills and training; logged._x001C_
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Electrical
Issued 27 March 1996 Resolved
Provide portable lights IAW 46 CFR 183.420.
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Lifesaving
Issued 27 March 1996 Resolved
Renew PFD reflective tape as needed.
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Documentation
Issued 27 March 1996 Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 1 September 1996
Resolved 1 September 1996
Engineering
Issued 29 September 1994 Resolved
PROVIDE PROPER OIL CONTAINMENT AROUND THE FUEL VENT, FUEL INTAKE, AND ALL HYDRAULIC STEERING RAMS ON THE PUSHER UNIT.
Condition: Unknown
Due 1 October 1995
Resolved 1 October 1995
Navigation
Issued 12 August 1992 Resolved
REPAIR THE LEAK IN THE PUSHER UNIT HYDRAULIC RAM AND CYLINDER.
Condition: Unknown
Due 15 September 1992
Resolved 20 August 1992
Construction/Loadline
Issued 6 September 1991 Resolved
SHOW PROPER OPERATION OF THE BILGE SUCTION SYSTEM BY TAKING WATER THROUGH ABILGE SUCTION.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Engineering
Issued 6 September 1991 Resolved
PROPERLY INSTALL FUEL SHUTOFF VALVES LOCATED AT THE TANK CONNECTION, TO BE OPERABLE FROM THE WEATHER DECK.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Engineering
Issued 6 September 1991 Resolved
INSTALL VENTALATION PIPING TO THE MACHINERY SPACE SO THAT ONE EXHAUST VENT VENTS FROM THE BOTTOM OF THE COMPARTMENT.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Engineering
Issued 6 September 1991 Resolved
PROPERLY INSTALL FUEL TANK VENT TO TANK AS PER 46 CFR 182.20-35(A).
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Fire Fighting
Issued 6 September 1991 Resolved
ALL BII FIRE EXTINQUISHERS ARE TO BE HYDROED. INSURE PROPER COAST GUARD APPROVED EXTINQUISHERS ARE ONBOARD DURING SERVICING.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Electrical
Issued 6 September 1991 Resolved
PROPERLY SECURE BATERIES TO PREVENT MOVEMENT AND REPLACE COVERS.
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Engineering
Issued 26 September 1990 Resolved
REPAIR OR REPLACE THE STEERING PUSHER RAM ASSEMBLY. UNIT HAS GREATER THAN 1/4 INCH PLAY IN THE SYSTEM.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Navigation
Issued 8 September 1989 Resolved
DOUBLE NUT OR DRILL AND PIN PORT TILLER ARM TO RUDDER CROSS BAR.
Condition: Unknown
Due 1 October 1989
Resolved 1 October 1989
Documentation
Issued 12 September 1988 Resolved
MARK THE VESSEL'S NAME AND HAILING PORT WITH CLEARLY LEGIBLE LETTERS NOT LESS THAN 4 INCHES HIGH AS REQUIRED BY 46 CFR 67.15-3(B).
Condition: Unknown
Due 1 October 1988
Resolved 1 October 1988
Unknown
Issued 20 August 1986 Resolved
PROVIDE AND PLACE ON BOARD THE VESSEL 3 NEW CHILDREN'S LIFE PRESERVERS.
Condition: Unknown
Due 1 October 1986
Resolved 1 October 1986

Ownership record