MAURY USCG vessel records
← All vessels

EMY JO

EMY JO is a 1959 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in September 2025, along with 15 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 9 September 2025.

Built
1959
Last inspected
9 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 September 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-45671

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.2 ft
Registered tonnagegross 14 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWAILUA, HI, UNITED STATES · built 1959
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWAILUA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

9 September 2025 COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8230481
6 May 2025 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8129880
6 May 2025 Hull Examination
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8129929
12 September 2024 Internal Structural Exam · Drydock Extension
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8003792
6 November 2023 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7821055
21 November 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7597996
14 October 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7333212
24 August 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7296851
25 November 2020 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7100957
4 December 2019 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6867580
16 January 2019 Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6611355
13 November 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306151
30 November 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6050973
9 February 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5812395

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2025 Resolved
The power fire pump shall be self-priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Fire pump did not have effective stream. Provide fire pump with effective stream. Old - T 46 CFR 181.10-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2025
Resolution: Fire pump provided effective stream.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2025 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. 02 ventilation ducts opening in forward engine space were not equipped with means of closure outside of the engine room. Provide means of closing ventilation. 46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2025
Resolution: Vent closure provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Power steering belt came off of pulley during man overboard drill causing vessel to lose steering. Make repairs to steering and conduct sea trial. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2025
Resolution: Steering repaired and sea trial conducted.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 September 2025 Resolved
The OCMI may require the vessel to get underway. Man overboard not completed due to loss of steering. Get underway in presence of marine inspector to conduct drills. 46 CFR 176.404(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2025
Resolution: Man overboard drill conducted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2025 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Override for Fireboy in engine room did not work. Demonstrate override to the attending USCG marine inspector. 46 CFR 181.400
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2025
Resolution: Override operational.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 September 2025 Resolved
A complete application for an original MMC must contain proof, documented on CG-719-K or CG-719-K/E, as appropriate, that the applicant passed all applicable vision, hearing, medical, and/or physical exams as required by subpart C of this part or a valid medical certificate issued by the Coast Guard. The Master did not have his medical certificate available.Provide master who has valid medical certificate to meet manning requirements. 46 CFR 10.302(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 17 October 2025
Resolution: Master provided who had valid medical card.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2025 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting drills and training. Provide drill logs showing training. 46 CFR 185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 17 October 2025
Resolution: Logbooks showing training provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2025 Resolved
All vessels must undergo an inspection for certification as specified in 176.404 and annual inspection as specified in paragraph (b)(1) (b)(1)-Annual inspection, Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. 25NOV2024 was EMY JO issued date of its COI. The annual drop dead date was 25FEB2025. The vessel has been out of compliance and will need to complete a COI Renewal inspection. The vessel shall carry passengers until an inspection is complete to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2025
Resolved 6 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2022 Resolved
MI found 18 life jackets no longer serviceable putting max total of people on board to 59. Provide 7 serviceable life jackets.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Vessel put into service 07 new serviceable life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022 Resolved
MI found wasted J-Box for wire connection. Replace box with a capable J-Box to protect connections and prevent fire.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Old J-box was removed and new J-box was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 November 2022 Resolved
MI found the fuel supply line from the tank to the filter collapsed. Provide serviceable fuel line and prove op test.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 November 2022
Resolved 21 November 2022
Resolution: New fuel supply hose was installed and satisfactory op tested.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 21 November 2022 Resolved
MI found interior light not capable of illuminating. Provide serviceable interior lighting system and prove its capable of turning off and on.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Lights were not illuminating because fuse was damaged. After replacing fuse with same size, power was provide back to the interior lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Batteries connections are required to be permanent to prevent connections from being loose. The terminal connections on the two batteries had loose connections. Tighten the battery connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2019
Resolved 5 December 2019
Resolution: Battery connections were tightened during the inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 February 2019 Resolved
Bilge high water alarms are required to alarm audibly and visually at the operating station. The provided visual alarm was not operating. Provide a visual bilge high water alarm.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 February 2019
Resolved 25 February 2019
Resolution: Bilge high water alarm provided and verified by MI prior to inspection ending.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2016 Resolved
Found areas of rotted wood hull plating on fwd port area of vessel and on Stbd aft location near transom. ALl wood is being cropped out & renewed prior to entering service.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 19 April 2016
Resolution: All rotted wood hull plating was located removed and replaced in kind. all repairs found sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.