Records from 1985 to 2026. Most recent: inspection, 29 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 53
29 January 2026
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8303566
9 September 2025
Vessel Attendance · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8230489
20 January 2025
Drydock Extension · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8065664
6 June 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7955354
14 July 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7763665
17 May 2023
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690992
1 September 2022
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7447922
9 February 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396296
18 May 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200517
24 July 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012360
14 June 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6714256
1 May 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6403539
18 April 2017
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6127715
9 June 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5902777
6 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5899415
25 June 2014
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4907677
6 January 2012
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4220063
7 July 2008
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3282228
14 May 2007
COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2930232
4 May 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2922562
15 January 2007
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2847409
3 February 2006
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2579041
12 May 2005
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2356158
17 March 2005
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2317805
1 July 2004
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2238914
21 April 2004
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2031327
28 January 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1735023
28 January 2002
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1479770
18 April 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366313
9 March 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1047206
16 February 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389005
16 February 1999
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1464152
11 December 1997
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368515
22 May 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 776974
14 March 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1400517
27 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357530
13 December 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434335
15 June 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1409313
7 July 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429909
9 July 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 843223
9 June 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154395
15 June 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1258634
25 July 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937918
27 July 1990
Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913907
4 May 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909033
4 May 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913750
8 November 1989
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1351297
15 August 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1045251
27 July 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1038497
2 July 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1328781
12 November 1986
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015816
21 August 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989711
29 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983078
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2026
Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Drug training for supervisors not completed. Provide satisfactory evidence of 60 min training for supervisors.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Drug training completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2026
Resolved
Each EAP education program must include at least the following elements: display and distribution of the employer's policy regarding drug and alcohol use in the workplace. No policy displayed. Provide drug policy.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Drug policy provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 January 2026
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station not labeled. Provide marking for fuel shutoff.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Fuel shut off labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 February 2022
Resolved
Crop out soft wood to good wood along Port Aft quarter. Inspect beams along soft areas, make satisfactory repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 21 March 2022
Resolution: 17" x 20' wood hull plating was cropped out and replace in-kind, refasten, and fiber glassed. Beams 18-27 were sandwich satisfactory with 2"x12"x4' Treated Douglas Fir.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2018
Resolved
Dead end wiring is required to be terminated in a junction box or removed. Old 110v wiring still exists in the bilge, remove or terminate the wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 7 May 2018
Resolution: Dead end wiring was removed.
Construction/Loadline › Hull › Bottom Plating
Issued 9 June 2016
Resolved
Found several areas on both Port & Stbd aft bottom of rotetd plywood used for bottom plating. All rotted wood to be identified, cropped & renewed.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 September 2016
Resolution: All rotted wood plating replaced in kind.
Construction/Loadline › Structures › Deck Plating
Issued 9 June 2016
Resolved
Found several area of rotted wood structures on both port & stbd side bottom plating, transverse members and longitudinals. All rotted wood to be replaced in kind.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 September 2016
Resolution: All rotted wood plating replaced in kind.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 July 2008
Resolved
Safeguard fire pump control lever from rotating belt on front of stbd engine.
Due 7 August 2008
Resolved 8 August 2008
Resolution: installed guard
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 7 July 2008
Resolved
Provide proof of CPR training for crew.
Due 7 August 2008
Resolved 11 August 2008
Resolution: Received class roster of first aid and CPR training
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2008
Resolved
Non-standard wire splices found on wiring under operating station. Make permanent splice repairs to same.
Due 7 August 2008
Resolved 8 August 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 July 2008
Resolved
Found multiple dead-end wires under operating station console. Make repairs to same to make safe.
Due 7 August 2008
Resolved 8 August 2008
Resolution: removed wires
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 July 2008
Resolved
Label life preserver stowage containers to reflect quantity and size.
Due 7 August 2008
Resolved 8 August 2008
Resolution: labeled containers
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 March 2005
Resolved
Provide battery box covers.
Condition: Unknown
Due 1 April 2005
Resolved 26 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2005
Resolved
Remove or properly repair dead end wires throughout barge.
Condition: Unknown
Due 1 April 2005
Resolved 26 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2005
Resolved
Provide metal supports for wiring throughout barge.
Condition: Unknown
Due 1 April 2005
Resolved 26 April 2005
Operations/Management › Drills/Instruction › Fire
Issued 17 March 2005
Resolved
Provide proof of fire and man overboard drills.
Condition: Unknown
Due 1 April 2005
Resolved 19 April 2005
Documentation
Issued 16 February 2000
Resolved
Provide documentation outlining company drug policy program in writing. Ensure policy conforms to employee assistance program (EAP) as outlined in 46 CFR 16.401.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Documentation
Issued 16 February 2000
Resolved
Provide records of chemical drug tests conducted on employees IAW 46 CFR 16.260.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Lifesaving
Issued 14 March 1997
Resolved
Provide a CG approved first aid kit as required by 46 CFR 184.710.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 27 March 1996
Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training emergencydrills.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996
Resolved
Provide evidence of compliance with 46 CFR 185.520, abandon ship and man overboard drills and training.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996
Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills and training; logged.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Electrical
Issued 27 March 1996
Resolved
Provide portable lights IAW 46 CFR 183.420.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996
Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Engineering
Issued 4 May 1990
Resolved
DEMONSTRATE SATISFACTORY MACHINERY OPERATION OF PUSHER UNIT TO ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990