Documentation record
Registered dimensions (L × B × D)60.0 ft × 20.4 ft × 3.0 ft
Registered tonnagegross 33 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWAILUA, HI, UNITED STATES · built 1964
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWAILUA, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 15 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
29 January 2026
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8303566
9 September 2025
Vessel Attendance · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8230489
20 January 2025
Drydock Extension · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8065664
6 June 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7955354
14 July 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7763665
17 May 2023
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690992
1 September 2022
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7447922
9 February 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396296
18 May 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200517
24 July 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012360
14 June 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6714256
1 May 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6403539
18 April 2017
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6127715
9 June 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5902777
6 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5899415
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2026
Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Drug training for supervisors not completed. Provide satisfactory evidence of 60 min training for supervisors.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Drug training completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2026
Resolved
Each EAP education program must include at least the following elements: display and distribution of the employer's policy regarding drug and alcohol use in the workplace. No policy displayed. Provide drug policy.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Drug policy provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 January 2026
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station not labeled. Provide marking for fuel shutoff.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2026
Resolved 10 March 2026
Resolution: Fuel shut off labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 February 2022
Resolved
Crop out soft wood to good wood along Port Aft quarter. Inspect beams along soft areas, make satisfactory repairs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 21 March 2022
Resolution: 17" x 20' wood hull plating was cropped out and replace in-kind, refasten, and fiber glassed. Beams 18-27 were sandwich satisfactory with 2"x12"x4' Treated Douglas Fir.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2018
Resolved
Dead end wiring is required to be terminated in a junction box or removed. Old 110v wiring still exists in the bilge, remove or terminate the wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 7 May 2018
Resolution: Dead end wiring was removed.
Construction/Loadline › Hull › Bottom Plating
Issued 9 June 2016
Resolved
Found several areas on both Port & Stbd aft bottom of rotetd plywood used for bottom plating. All rotted wood to be identified, cropped & renewed.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 September 2016
Resolution: All rotted wood plating replaced in kind.
Construction/Loadline › Structures › Deck Plating
Issued 9 June 2016
Resolved
Found several area of rotted wood structures on both port & stbd side bottom plating, transverse members and longitudinals. All rotted wood to be replaced in kind.
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 28 September 2016
Resolution: All rotted wood plating replaced in kind.