MAURY USCG vessel records Sign in
← All vessels

RIVER BOAT

RIVER BOAT is a 1960 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1985, most recently in October 2008, along with 28 deficiencies.

Records from 1985 to 2008. Most recent: inspection, 15 October 2008.

Built
1960
Last inspected
15 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45674

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (1985–2008)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
12 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

15 October 2008 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3345270
10 December 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3112986
16 May 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3001048
27 October 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2809476
22 September 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2596208
19 January 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2270974
16 December 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1963411
16 December 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1724714
13 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1702837
30 May 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1616873
21 March 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1495798
15 February 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1485226
4 January 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1475763
29 October 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1076396
25 September 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417381
17 October 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1446997
19 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 809850
13 October 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378837
28 September 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345532
11 August 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1112090
18 December 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368989
7 October 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364895
16 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364409
13 September 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363788
15 December 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360356
12 October 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360299
21 August 1995 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1186817
10 August 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1188996
15 June 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1186627
8 November 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377303
9 November 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354489
15 December 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1142089
10 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 960851
10 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1188998
15 July 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393858
14 November 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1250623
5 November 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916804
8 November 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1042237
2 June 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1208441
25 October 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 890133
18 November 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1024629
5 November 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1024350
12 November 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018460
23 September 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1005874
7 November 1985 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301604

Deficiency record · 28

Documentation › Logs/Records › Logbook (official)
Issued 10 December 2007 Resolved
Log fire and man overboard drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 10 December 2007
Operations/Management › Drills/Instruction › Fire
Issued 19 January 2005 Resolved
Include vent covers in fixed fire system operating instructions IAW 46CFR185.612.
Condition: Unknown
Due 10 February 2005
Resolved 16 February 2005
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 19 January 2005 Resolved
Provide posted procedures at operating station for checking proper operation of flammable vapor detector system.
Condition: Unknown
Due 10 February 2005
Resolved 16 February 2005
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 19 January 2005 Resolved
Provide operation and maintenance manual for the flammable vapor detection system for vessel. Vessel is required to maintain manual on board at all times.
Condition: Unknown
Due 10 February 2005
Resolved 16 February 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 16 December 2003 Resolved
Prove engine room vapor detection sensor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 16 December 2003 Resolved
Prove backfire flame arrestor. The backfire flame arrestor is loose and not designed for the carburetor that is presently installed on. LEGACY COMPONENT DESC: Backfire Flame Control
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2005
Resolved 18 January 2005
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 16 December 2003 Resolved
Install second exhaust duct in engine room ventilation system. LEGACY COMPONENT DESC: Ventilation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2002 Resolved
Renew 10 adult lifejackets, due to worn straps. Reduced passenger count by 10 until lifejackets are renewed. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 November 2002 Resolved
Renew retro-reflective material on all lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 16 December 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 November 2002 Resolved
Provide first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Communications › Visual Communication
Issued 13 November 2002 Resolved
Provide lifejacket donning placard. LEGACY COMPONENT DESC: Lifejacket donning placard
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Engineering › Reduction Gearing/Clutches
Issued 13 November 2002 Resolved
Install missing reduction gear foundation bolts & tighten. LEGACY COMPONENT DESC: Bolt
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 16 December 2002
Construction/Loadline › Hull
Issued 15 February 2002 Resolved
Vessel's bottom constructed of 3/4 inch plywood. Rot noted in various locations as marked & per notes. Provide hull repair plans to MSO Honolulu for approval prior to commencing repairs. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 30 May 2002
Resolution: Vessel operator repaired wood rot on vessel''s hull.
Lifesaving
Issued 25 September 2001 Resolved
Provide a battery operated bullhorn in accordance with 46 CFR 184.610 or alternatively provide equipment to complete the installed PA system prior to operating with passengers.
Condition: Unknown
Due 26 September 2001
Resolved 3 November 2001
Lifesaving
Issued 25 September 2001 Resolved
Provide a properly equipped ring life buoy with water light, 3-6' lanyard and 60' line in accordance with 46 CFR 180.70. Vessel is restricted to_x001C_ daylight operation until ring buoy is equipped with a water light.
Condition: Unknown
Due 2 October 2001
Resolved 3 November 2001
Fire Fighting
Issued 11 August 1999 Resolved
Replace or modify fixed fire fighting system to meet requirements as outlined in 46 CFR 181.400 or 46 CFR 420._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Engineering
Issued 10 November 1992 Resolved
INSTALL SUITABLE VENTILATION OF THE GASOLINE ENGINE COMPARTMENT AS REQUIREDBY 46 CFR 182.15-45. TWO INLET DUCTS LOCATED AT ONE END OF THE COMPARTMENTSHALL EXTEND TO THE BILGE. TWO EXHAUST DUCTS SHALL BE LED TO TWO EXHAUST BLOWERS FROM THE BILGE LOCATED OPPOSITE THE INLET DUCTS.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Construction/Loadline
Issued 15 July 1992 Resolved
CROP AND RENEW TO GOOD WOOD THE DETERIORATED SECTION OF THE FORWARD RAKE DECK IN THE WAY OF THE PORT SIDE MOORING LINE RING.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
RENEW THE WASTED FASTENERS IN THE SECTION OF THE PORT SIDE SHELL PLYWOOD INWAY OF THE LAST RUB RAIL.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 15 July 1992 Resolved
RENEW THE WASTED EXHAUST FITTING ON THE STERN.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
RENEW THE DETERIORATING NON SKID ON THE FORWARD RAKE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
CROP AND RENEW TO GOOD WOOD THE 8'X 8' SECTION OF DETERIORATED BOTTOM PLYWOOD LOCATED APPROXIMATELY 8 FT. AFT OF FORWARD RAKE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
RENEW THE WASTED FASTENERS IN THE SECTION OF PLYWOOD ON THE STARBOARD SIDE LAST SECTION OF PLYWOOD CONNECTED TO THE STERN AND THE CHINE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
CROP AND RENEW TO GOOD WOOD APPROXIMATELY 10 FOOT LENGTH OF SIDE PLYWOOD 2ND PLY UP FROM CHINE AND FORWARD OF STERN.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Construction/Loadline
Issued 15 July 1992 Resolved
GRIND OUT AREA OF SOFT WOOD IN WAY OF PORT SIDE SHELL LOCATED APPROXIMATELY10 FEET AFT OF FORWARD RAKE.
Condition: Unknown
Due 22 July 1992
Resolved 22 July 1992
Engineering
Issued 5 November 1987 Resolved
LABEL EMERGENCY FUEL OIL CUTOFF VALVE.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Fire Fighting
Issued 5 November 1987 Resolved
REPLACE PVC FIREMAIN PIPING WITH METALLIC PIPING.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987
Engineering
Issued 5 November 1987 Resolved
REPLACE FUEL OIL TANK FLAME SCREEN.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.