Records from 2016 to 2023. Most recent: inspection, 25 October 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
25 October 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7814824
2 May 2023
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7684580
28 April 2023
Plan Review "T" Boat · Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7677635
5 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7497292
27 June 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7489187
17 June 2022
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7486041
19 May 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7454946
22 September 2021
Internal Structural Exam · Examination of Repairs · Administrative Inspection · DAPI Audit · Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7318960
18 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7064307
12 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6952271
13 November 2019
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6858120
14 June 2019
DAPI Audit · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6725610
20 May 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6688642
15 April 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6663174
21 March 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6376281
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360467
11 October 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6281951
21 March 2017
COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6106785
22 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5838481
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 June 2022
Resolved
Each Vsl that relies on electricity to power the following loads must be arranged so that the load can be energized from two sources of power. Both generators had casualties and are not operational. Repair or replace both generators to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2022
Resolution: Generators operated satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2021
Resolved
Vessel has pneumatic thottles. A prtable air compressor is attached and used for the throttle system. Return system to original or submit plans to USCG for approval for alternative system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 2 June 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 September 2021
Resolved
Remove excess stored paint in midspace or place in approved flame locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 4 October 2021
Resolution: Excess paint removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2021
Resolved
Provide support for wiring in overhead of engine room. Proper support not more than 24" apart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 4 May 2022
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2021
Resolved
Ensure life jacket lights are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 April 2022
Resolution: operational
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 September 2021
Resolved
Label emergency escape for accommodation space on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 4 May 2022
Resolution: labeled
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 September 2021
Resolved
Rmove all daisy chains.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 April 2022
Resolution: removed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 September 2021
Resolved
Renew forward smoke detector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 20 April 2022
Resolution: renewed
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 22 September 2021
Resolved
Provide rails for stove top.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2021
Resolved 2 June 2022
Resolution: all sat
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 September 2020
Resolved
The Master shall conduct sufficient drills and training for man overboard, abandon ship, and fire drills. Drills shall be logged to include a general description of the drill scenario and training topics. Drills were conducted sporadically and logs were lacking information. Properly log drills conducted on 18SEP20 and conduct regularly scheduled drills when in operation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 23 September 2020
Resolution: Vessel conducted drills and properly logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 September 2020
Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable raft be tested monthly. The EPIRB test shall be logged. EPIRB tests were not logged. Log September 2020 EPIRB test and maintain testing and logbook while vessel is operating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2020
Resolved 23 September 2020
Resolution: Master tested EPIRB and properly logged.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 September 2020
Resolved
Electrical equipment must be installed to provide services necessary for safety under normal and emergency conditions. Additional engine room lighting has been installed using extension cords. Permanently install or remove the additional lighting to the satisfaction of attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2020
Resolved 23 September 2020
Resolution: Additional lighting and extension cords removed from vessel's engine room.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 September 2020
Resolved
Observed unsafe fire hazards must be corrected. Numerous buckets of oil are being stored in the engine room. Remove buckets and properly store to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 23 September 2020
Resolution: 5 gallon oil buckets removed from vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 December 2019
Resolved
Vessel's anchor light is not UL 1104 approved. Replace anchor light with UL 1104 approved.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2020
Resolved 23 December 2019
Resolution: Inspected installation of UL 1104 anchor light; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 December 2019
Resolved
Numerous electrical "daisy chains" were identified in the steering console. Remove "daisy chains" and make proper electrical connections to the satisfaction of an attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2020
Resolved 23 December 2019
Resolution: Inspected proper electrical connections in the center console; all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 December 2019
Resolved
Vessel was unable to demonstrate proper operation of the bilge system. Demonstrate proper operation of the bilge system by moving water from each space serviced to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Witnessed operation of the bilge system; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 December 2019
Resolved
Engine room portable fire extinguisher was not stored in an acceptable bracket. Properly store portable extinguisher to the satisfaction of an attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Inspected portable extinguisher bracket; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 December 2019
Resolved
Pilot house battery box is not properly secured. Secure battery box to the satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 23 December 2019
Resolution: Inspected battery box installation; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2019
Resolved
improper vessel name was marked on life jacket. Currently marked as Mystics Sea.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 7 July 2019
Resolved 14 June 2019
Resolution: PFD's re-labelled with SBS TRANSPORTER
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2019
Resolved
about 8' ft of cables were secured above by plastic zip ties at the passage way towards the pilot house. Need to replace with metallic supports no more than 24" inches apart.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 7 July 2019
Resolved 14 June 2019
Resolution: Cables secured to overhead in passageway adjacent to pilothouse.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 May 2019
Resolved
Aux battery cables was secured by wing nuts. need to replace with permenant type connector (not wing nuts).
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 7 July 2019
Resolved 14 June 2019
Resolution: Battery cables permanently connected to batteries.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2018
Resolved
REMOVE DEAD END WIRES FOUND IN E/R - 46 CFR 183.05-50 - 21APR2018
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 3 May 2018
Electrical › Electric Supply System (service) › Cable
Issued 21 March 2018
Resolved
BATTERY CHARGERS AND BLOCK HEATERS WERE FOUND TO BE POWERED USING FLEXABLE EXTENSION CHORDS - 46 CFR 183.10-20(A)(2) - 21APR2018
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 3 May 2018
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 21 March 2017
Resolved
Drug and alcohol program not properly documented. Review 46 CFR 16 and ensure full compliance.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 6 April 2017
Resolution: Enrolled in a consortium (APCA) to help marine employer run and maintain the drug and alcohol program.
Documentation › Certificates/Documents › FCC SSL
Issued 21 March 2017
Resolved
FCC Station License expired in 2016. Renew FCC station license. 47 CFR 80.13
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 6 April 2017
Resolution: FCC station license registration submitted.
Engineering › Fuel Oil Service System › Hose
Issued 21 March 2017
Resolved
Various hoses and hose fittings for F/O systems are unapproved IAW SAE J-1492/ SAE J-1475. Renew IAW standards above.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 16 May 2017
Resolution: Replaced with compliant hose.