Records from 1997 to 2003. Most recent: inspection, 22 August 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
22 August 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1883625
13 May 2003
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1765866
15 July 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1646643
8 May 2002
Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1618668
21 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418874
6 October 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 823542
12 July 2000
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 820628
21 March 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467670
25 August 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 781864
11 May 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469898
25 March 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1450275
29 April 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461891
28 March 1997
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1422863
Accommodation/Occupational Safety › Occupational Safety
Issued 13 May 2003
Resolved
Provide chain for port side embarkation station. LEGACY COMPONENT DESC: Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2003
Resolved 22 August 2003
Electrical › Electrical Distribution System (service)
Issued 13 May 2003
Resolved
Remove or re-connect dead end wires in way of starboard fuel tank. LEGACY COMPONENT DESC: Wiring
Due 22 May 2003
Resolved 22 August 2003
Construction/Loadline › Structures
Issued 13 May 2003
Resolved
Provide new "D" rings for lifting and securing starboard fuel tank space and provide means of supporting open hatches in way of port and starboard fuel tank spaces. LEGACY COMPONENT DESC: Scuttle
Due 22 May 2003
Resolved 22 August 2003
Engineering › Fuel Oil Service System
Issued 13 May 2003
Resolved
Remove fuel filters w/plastic bowls from fuel tank space. LEGACY COMPONENT DESC: Filter
Due 22 May 2003
Resolved 22 August 2003
Engineering › Gasoline Engine (propulsion)
Issued 13 May 2003
Resolved
Interlock blower with ignition switch. LEGACY COMPONENT DESC: Ventilation
Due 22 May 2003
Resolved 22 August 2003
Communications › Alarms/Indicators
Issued 13 May 2003
Resolved
Provide operating vapor detector and instructions for port and starboard fuel tank spaces.
Due 22 May 2003
Resolved 22 August 2003
Engineering › Gasoline Engine (propulsion)
Issued 13 May 2003
Resolved
Provide ventilation closures for fuel tank space vents. LEGACY COMPONENT DESC: Ventilation
Due 22 May 2003
Resolved 22 August 2003
Operations/Management › Drug and Alcohol Testing
Issued 13 May 2003
Resolved
Provide proof of enrollment in a Drug and Alcohol Testing Program. LEGACY COMPONENT DESC: Proof of Enrollment
Due 22 May 2003
Resolved 22 August 2003
Lifesaving › Hand Flares
Issued 13 May 2003
Resolved
Provide one additional red hand flare onboard. LEGACY COMPONENT DESC: Quantity
Due 22 May 2003
Resolved 22 August 2003
Lifesaving › Lifebuoys
Issued 13 May 2003
Resolved
Provide retro-reflective tape for ring bouy. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 22 May 2003
Resolved 22 August 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 May 2003
Resolved
Provide updated aspirin for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 22 May 2003
Resolved 22 August 2003
Engineering › Gasoline Engine (propulsion)
Issued 13 May 2003
Resolved
Prove proper operation of port engine.
Due 22 May 2003
Resolved 22 August 2003
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 April 2003
Resolved
Weld gap and pinhole in way of port #2 void aft bulkhead (missed from construction).
Due 21 April 2003
Resolved 13 May 2003
Construction/Loadline › Hull
Issued 1 April 2003
Resolved
Prepare vessel for drydock examination; de-water and clean all bilges.
Due 7 April 2003
Resolved 11 April 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2003
Resolved
Remove dead end wiring for old windshield wipers.
Due 7 April 2003
Resolved 11 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 April 2003
Resolved
Renew/remove wasted center bow window struts.
Due 7 April 2003
Resolved 11 April 2003
Documentation › Markings/Placards
Issued 8 May 2002
Resolved
LABEL EMERGENCY FUEL SHUT-OFF'S
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 15 July 2002
Communications › Alarms/Indicators
Issued 8 May 2002
Resolved
REPAIR HIGH WATER BILGE ALARM. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 21 May 2002
Resolved 15 July 2002
Documentation
Issued 21 March 2001
Resolved
PROVIDE PROOF OF ENROLLMENT IN DRUG TESTING PROGRAM WITH CONSORTIUM OR PROVIDE COPY OF EMPLOYER RUN PROGRAM.
Condition: Unknown
Due 5 April 2001
Resolved 15 July 2002
Fire Fighting
Issued 12 July 2000
Resolved
MAKE AUTOMATIC FIRE EXTINGUISHING SYSTEM AVAILABLE FOR FINAL INSTALLATION INSPECTION BY COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Engineering
Issued 11 May 1999
Resolved
INSTALL VAPOR DETECTORS IN BOTH FUEL TANK SPACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Construction/Loadline
Issued 11 May 1999
Resolved
REPAIR ALL BILGE PUMP RUNNING INDICATOR LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999
Resolved
INSTALL RETRO TAPE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999