COMMANDER

COMMANDER is a 1997 industrial vessel. The Coast Guard has recorded 93 inspections since 1997, most recently in June 2026, along with 94 deficiencies — 4 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2009 and 2011.

Records from 1997 to 2026. Most recent: inspection, 29 June 2026.

Built
1997
Last inspected
29 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9132234 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDJ9154
456979
Flag
UNITED STATES
367514980
Maury page id
psix-456979

Inspections, by type

…with no type recorded12
Years with a record 26 calendar years (1997–2026)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)221.7 ft × 56.0 ft × 18.8 ft
Registered tonnagegross 1,471 / net 1,000
ITC dimensions (L × B × D)221.7 ft × 56.0 ft × 18.8 ft
ITC tonnagegross 1,891 / net 820
BuilderNORTH AMERICAN FABRICATOR · HOUMA, LA, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 March 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it820 - Convention (Subpart B), Net Ton
2669 - Dead Weight, Ton
4148 - Displacement, Ton
1471 - Regulatory (Subpart C or D), Gross Ton
1000 - Regulatory (Subpart C or D), Net Ton
1891 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9154MMSI 367514980 · active · compulsorily equipped · granted 14 February 2018, expires 14 February 2028
WDG2373MMSI 367514980 · cancelled · compulsorily equipped · granted 11 January 2012, cancelled 18 January 2018
WCX6345MMSI 366240000 · cancelled · voluntarily equipped · granted 12 May 2007, cancelled 6 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOLLING TIDE Offshore Supply Vessel · MISLE 50547 · 30 September 1997 · activity 161808SEABULK MASSACHUSETTS Offshore Supply Vessel · MISLE 51488 · 30 September 1997 · activity 161808

Inspection history · 93

29 June 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8418815
13 January 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8296867
30 May 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8147649
21 May 2025 Deficiency Check · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139063
2 January 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8056862
4 December 2024 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8042970
10 September 2024 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8023429
26 June 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7942831
16 May 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7912895
4 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7873702
30 August 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7784796
7 August 2023 Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7762155
5 July 2023 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7724711
20 April 2023 Plan Review (Other than "T") · Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7674347
12 April 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7667078
4 April 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7655489
31 January 2023 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7629675
12 May 2022 MTSA Verification · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7449238
22 April 2022 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7436102
22 November 2021 Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7355890
13 October 2021 Commercial Dive Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7331790
18 August 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7290593
4 June 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7222617
27 May 2021 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7208290
22 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160445
19 October 2020 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7080713
31 August 2020 Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7053026
24 July 2020 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7014970
10 June 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6979367
5 June 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6968844
7 March 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6933520
18 November 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6857403
1 November 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6847387
29 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6765851
16 July 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6753986
23 April 2019 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6668203
28 March 2019 MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6650595
4 February 2019 Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6620024
12 December 2018 Damage Survey · Administrative Inspection · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6618482
25 October 2018 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6563278
1 September 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6543133
1 September 2018 Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6548206
30 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6527213
12 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6436179
4 June 2018 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6433665
14 February 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6355037
19 October 2017 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6291092
19 October 2017 Administrative Inspection
Administrative · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6297584
30 August 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6256903
20 July 2017 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6228065
14 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6208584
8 May 2017 Administrative Inspection · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6141424
5 May 2017 COI Inspection · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6148649
23 February 2017 DAPI Audit · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093258
13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876309
11 July 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4375285
23 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4125940
7 July 2011 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4071928
17 March 2009 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3451595
17 January 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3395910
17 January 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3401893
13 January 2009 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3414941
9 October 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3341261
24 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213439
26 April 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919018
4 April 2007 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2901957
18 July 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2717275
8 March 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2598563
7 March 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2597885
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501603
15 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2463744
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293948
5 January 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2269193
22 October 2004 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2225981
6 April 2004 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2038282
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979522
4 September 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1896651
29 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1668228
3 April 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1600293
30 July 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443225
28 July 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393499
9 May 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406713
12 August 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762727
31 July 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 196891
30 July 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432162
28 July 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383919
16 April 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 129494
8 April 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123291
22 October 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778152
30 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 161808
30 July 1997 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380905
16 July 1997 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115842
8 February 1997 Initial Construction-Excluding Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466994

Deficiency record · 94

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 May 2025 Resolved
The inspection shall be such as to insure that the vessel, as regards the fire-detecting and extinguishing equipment, is in satisfactory condition and fit for the service for which it is intended. During testing of the fixed CO2 system, cracks were identified in a CO2 check valve, allowing gas to escape and cause the time delay to go over the maximum allowable time. Repair/replace check valve and retest in the presence of MI. 46 CFR 91.25-10 27MAY2025: Granted vessel permission to travel to fuel dock on 5/27/25 and back to pier.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 May 2025
Resolution: Replaced time delay. Test SAT (36 seconds).
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025 Resolved
Bulkheads of galleys, paint and lamp lockers, and emergency generator rooms shall be of “A” Class construction. A-class door entering galley is missing locking mechanism creating a hole in the boundary. Repair/replace to the satisfaction of MI. 46 CFR 92.07-10 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Added lock.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 21 May 2025 Resolved
The rescue boat must meet the embarkation and launching arrangement requirements of §§ 199.110 (e) and (g), 199.150, 199.155, and if the launching arrangement uses falls and a winch, § 199.153. Remote brake release wire drum was found rusted/corroded and during testing, wire was chaffing and getting caught on rust. Clean wire drum of rust to satisfaction of MI.46 CFR 199.160 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 28 May 2025
Resolution: Cleaned/painted drum.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 May 2025 Resolved
Machinery driving forced-draft and induced-draft fans, fuel-oil transfer pumps, fuel-oil unit and service pumps, and similar fuel-oil pumps must be fitted with remote controls from a readily accessible position outside the space concerned so that the fans or pumps may be stopped in case of fire in the compartment in which they are located. Transfer pump remote stop in laundry room did not work. Repair to the satisfaction of the marine inspector. 46 CFR 58.01-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Emergency stop was labeled wrong. Fixed label.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2025 Resolved
Bulkheads or decks of the “A” Class shall be composed of steel or equivalent metal construction, suitably stiffened and made intact with the main structure of the vessel; Deck in electronic equipment room had holes. Repair to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Repaired deck
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2025 Resolved
Grounded neutral and high-impedance grounded neutral alternating current systems must have a suitably sensitive ground detection system... A provision must be included to compare indications under fault conditions with those under normal conditions. Ground detector in laundry space indicated a ground fault. Determine the cause of the fault and repair to the satisfaction of the marine inspector. 46 CFR 111.05-27
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 28 May 2025
Resolution: Cleaned electrical components and tightened connections on dryers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2025 Resolved
If the periodic inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the [name withheld] for the Trackvision was being held together by tape. Repair to the satisfaction of the Marine inspector. 46 CFR 126.510(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Welded support together.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 May 2025 No resolution recorded
The inspection shall be such as to insure that the vessel, as regards the structure, in is satisfactory condition and fit for the service for which it is intended. A hole was found in the port side rub rail aft of the embarkation station. Make temporary repairs to satisfaction of MI and permanent repairs at next drydock inspection. 46 CFR 91.25-10 Temporary repairs were made, but permanent repairs are still required.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2025 No resolution recorded
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Updated PSTPs did not match actual events. Submit amended PSTPs to MSC for approval and, once approved, demonstrate PSTPs to MI.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 21 May 2025 No resolution recorded
An accumulator is an unfired pressure vessel in which energy is stored under high pressure in the form of a gas or a gas and hydraulic fluid. Accumulators must meet the applicable requirements in part 54 of this subchapter. Accumulator on davit had corrosion. Determine extent and make necessary repairs prior to next credit drydock. 46 CFR 58.30-25(a)
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 May 2025 No resolution recorded
Each rigid container for an inflatable liferaft to be launched by a launching appliance must be secured so that the container or parts of it do not fall into the water during and after inflation and launching of the contained liferaft. Liferaft launch appliance had corrosion. Repair to the satisfaction of the MI prior to next credit drydock.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2024 Resolved
Persons designated by the owner of the vessel shall conduct all periodic automation tests to be witnessed by the Coast Guard; Generator #3 did not start. To repair generator #3 and witness associated generator tests IAW test procedures.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2024 Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to Coast Guard for approval. Automation test procedures are outdated and do not accurately reflect how the tests are carried out; to submit edits to Marine Safety Center (MSC) for review upon completion of edits.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2025
Resolution: Operator submitted procedures.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 August 2023 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment should be made without the knowledge of the OCMI. Vessel installed 13 air compressors, 02 HPUs and 02 gen sets onto cargo deck. Vessel approved to operate up to 30 days while plans are being reviewed by MSC, until it provides OCMI with approved plans from MSC of (1)equipment arrangement, (2)securing equipment, (3)securing calculations & (4)electrical one-line diagram for equipment on vessel cargo deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2023
Resolution: Received MSC approval letters
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2023 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment should be made without the knowledge of the OCMI. Vessel installed 02 unapproved Helix Portable Accommodations Module (PAMs). Please submit plans & obtain a PAM approval from the Coast Guard Marine Safety Center in accordance with enclosure 2(b) of CG-ENG Policy letter 01-16. "705 prior to operating while underway, PAMS temp removed from vsl 4/27"
Action required: 705 - Other - as specified
Due 27 April 2023
Resolved 20 June 2023
Resolution: Partial plan review by MSC (electrical) PAMs assigned CG# by SEC SE NE, Removed from vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 April 2023 Resolved
Provide updated drawings as per MSC approval letter to the CG marine inspector for the following: PAM Unit Securing Details & PAM Unit Securing Calcs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 April 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 April 2023 Resolved
Resubmit updated Equipment Arrangement to include A-frame and HPUs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 27 April 2023
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 20 April 2023 Resolved
Submit updated Fire Control Plan to account for lifesaving, fire detection & firefighting equipment for PAMs & other installed equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 April 2023 Resolved
Submit written alternative procedures to CG marine inspector for Public Address and General Alarm for the PAMs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 April 2023 Resolved
Repair vent closures on iROV Control Van PAM.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 April 2023 Resolved
Properly ensure structural fire protection is maintained on iROV workshop PAM where electric cables penetrate the bulkhead.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 April 2023 Resolved
Upon approval of written alternative procedures for general alarm, place by fire alarms in PAMs the following placard: "GENERAL ALARM-WHEN BELL RINGS GO TO YOUR STATION".
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 April 2023 Resolved
Place life jackets and immersion suits in sleeper PAM.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 20 April 2023 Resolved
Secure fuel lines on deck with step over treads.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2023 Resolved
This subpart (submission of electronic advanced notice of arrival) applies to the following vessel that are bound for or departing from ports or places within the navigable waterways of the United States: U.S. vessels in commerical service. Vessel arrived to the Sector SENE COTP zone without submission of an E-NOA and is not employed in the exploration for or in the removal of oil, gas, or mineral resources on the continental shelf. Title 33 CFR 160.203, Code 10C.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 12 April 2023
Resolved 12 April 2023
Resolution: Vessel's master submitted an E-NOA.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2023 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment should be made without the knowledge of the OCMI. Vessel is installing an unapproved Portable Accommodations Module (PAM) Transportable Sensitive Compartmented Information Facility (T-SCIF)& Crane installation on back deck for U.S. Navy. Please submit all relevant installation review to the Coast Guard Marine Safety Center in accordance with enclosure 2(b) of CG-ENG Policy letter 01-16.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 15 February 2023
Resolution: MSC Approved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2022 Resolved
Electrical cables were pulling out from starboard main engine panel and ballast pump motor. Properly secure electrical cables throughout the machinery spaces. 46 CFR 111.01-9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2022 Resolved
Starboard main engine control panel has an opening in the bottom and the inside of the panel is soiled. Clean panel and secure opening by means intended for by panel OEM. 46 CFR 111.01-9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 May 2022 Resolved
Battery box in engine room in way of lube oil filling hose was found with standing oil in box and on battery top. Clean box and battery. Properly secure battery box top to prevent intrusion of foreign matter. 46 CFR 111.15-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 May 2022 Resolved
The engine room sub alarm panel was found to be soiled inside. Additionally, the fan for this enclosure is hot to the touch and only spins when acted upon by an outside force. There is a second opening in the panel that appears to be for a filter and is open to the engine room. Clean enclosure, repair/replace fan and put in place filter that is intended for this enclosure. 46 CFR 111.01-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2022 Resolved
Fire hose station on port cargo deck valve assembly was leaking by and the fire hose was leaking. Conduct maintenance/repair leaking valve and replace leaking with hose. 46 CFR 95.10-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 May 2022 Resolved
Fuel built up in flame shield of lower level fuel filters below thruster engine. Preform maintenance on fuel filter/address cause of the leak and clean fuel. 46 CFR 95.25-45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 31 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 May 2022 Resolved
Pressure relieving device installed directly on each E/R pressure vessel. The relief valve testing & set pressure was unable to be verified for both (02) pressure vessels. Ensure pressure vessels are installed with bench tested relieving devices at the appropriate relieving pressure. 46 CFR 54.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2022
Resolved 31 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 May 2022 Resolved
Frequency meter on the #3 generator switchboard is cracked. Replace meter. 46 CFR 111.30-25 (e)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2022
Resolved 31 May 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 March 2021 Resolved
Emergency generator fuel tank E-stop valve does not fully close. Vessel must ensure cable is long enough so valve fully closes when the E-stop cable is pulled. 46 CFR 56.50-60
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 8 April 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2021 Resolved
Starboard MDE has excessive amount of soot/exhaust gases built up on lagging. Vessel shall ensure exhaust gas does not leak from the exhaust piping or connections and replace lagging that poses a fire hazard. 46 CFR 56.97-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 8 April 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 22 March 2021 Resolved
Grounding strap on the emergency diesel generator is not connected. Vessel must ensure all fuel tanks are bonded to the common ground. 46 CFR 56.50-10 (b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 8 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 March 2021 Resolved
The following fire doors were not adjusted or had broken latches preventing them from fully closing; O2 deck stair tower door leading to the bridge, O2 and O1 deck A/C room, O1 deck forward stairwell door, and both forward galley doors. 46 CFR 42.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2021
Resolved 8 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 March 2021 Resolved
Vessel did not have a deck line permanently embossed. Vessel must ensure both port and starboard sides of the have deck line permanently marked in accordance with vessel load line certificate and 46 CFR sub chapter E. 46 CFR 97.40-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 8 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 March 2021 Resolved
03 light covers in the aft steering space are cracked and partially missing. Vessel must ensure steering gear area has safe working access areas. 46 CFR 58.25-40
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 20 April 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2021 Resolved
Breaker panel P-401 door located in the Engine Room will not latch or close properly. Ensure panel door operates properly. 46 CFR 111.40-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 20 April 2021
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 22 March 2021 Resolved
Vessel company name is not correct on the electronic Certificate of Financial Responsibility (COFR). Any vessel using the navigable waters of the United States over 300G must have valid ensure correct company name is on COFR and valid. 33 CFR 138.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 21 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2021 Resolved
Vessel made unapproved modification to starboard back deck with the instillation of a lifting appliance welded to the structure. Drawings of repairs or alterations must be approved before work is started, vessel must provide all approved plans in accordance with this regulation. 46 CFR 91.55-10 & 46 CFR 91.55-15(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2021
Resolved 8 April 2021
Resolution: Vessel removed unapproved modification
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 August 2020 Resolved
Periodic Safety Test Procedures (PSTP's) are not being conducted and recorded in accordance with the CG approved PSTP's on board. Ensure vessel has necessary tools to complete tests as prescribed in PSTP's and conduct all tests in the presence of a marine inspector. 46 CFR 61.40-6(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2021
Resolved 7 August 2023
Resolution: Vessel has not provided updated PSTPs. When the company obtains accurate PSTPs, they will notify CG and request and inspection to review/observe procedures and update COI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 August 2020 Resolved
Bilges are dirty and pose a fire hazard. Vessel must ensure all engineering/machinery space bilges are cleaned and there is no accumulation of waste product, oils, etc. that might pose a fire hazard. 46 CFR 91.25-45
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2020
Resolved 28 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 31 August 2020 Resolved
Starboard anchor sheave is inoperable. Vessel shall be fitted with anchors, chains and hawsers in the general agreement with ABS standards and must ensure entire anchor arrangement is operable. 46 CFR 96.07-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2020
Resolved 28 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 August 2020 Resolved
Vessel masthead light is extinguished. Vessel must ensure all navigation lights are operable. Colregs 33 CFR 83.21(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2020
Resolved 28 September 2020
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 November 2019 Resolved
Test General Alarm, fire call station, smoke detection, emergency lighting, and ventilation shutdowns.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 November 2019
Resolution: Tested all required alarms. sat
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 1 November 2019 Resolved
Each vessel holding an International Load line Certificate shall have an Annual Survey conducted by the issuing authority. Have ABS complete an annual survey and endorse the International Load line Certificate. Vessel is restricted to waters landward of the boundary lines until this is completed. 46 CFR 42.09-40
Action required: 705 - Other - as specified
Resolved 2 November 2019
Resolution: Load line cert endorsed for completion of annual survey
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 July 2019 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Crane alterations being conducted, no drawings sumitted for approval.
Action required: 705 - Other - as specified
Resolved 23 August 2019
Resolution: Provided documentation to satisfaction of CG. Conducted load test at 125% rated new weight of 3LT, SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 March 2019 Resolved
Vessel required to have fire pump. Main fire pump is inoperable. Make repairs, demonstrate proper operation of main fire pump. Emergency pump tested sat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: demonstrated proper operation of main fire pump. Emergency pump tested sat also.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 28 March 2019 Resolved
Vessel required to have oily water separator. OWS inoperable. Make repairs, demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: demonstrated proper operation of OWS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2019 Resolved
Engine room air receivers relieve calves required to be tested for accuracy annually. Unable to perform test. Provide documentation of sat test on PRV (2).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: Provided documentation of sat test on new PRV (2).
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 28 March 2019 Resolved
Vessel required to have magnetic compass. Compass was removed for repairs. Provide magnetic compass, light and deviation table.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: Provided magnetic compass, light and deviation table.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 March 2019 Resolved
5. Vessel required to conduct release hook test on rescue boat launching equipment. Rescue boat on-load hook release test overdue. Conduct sat test and provide documentation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: Conducted sat test.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 March 2019 Resolved
Vessel required to have CFF Bridge to Bridge Act cert, Radio Telephony Safety Cert. Certificates expired. Provide valid certificates in compliance with FCC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2019
Resolved 5 April 2019
Resolution: Provided valid certificates in compliance with FCC.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 September 2018 Resolved
Vessel will affect repairs IVO stbd side frame 2-6 IAW repair proposal 9/13/2018 to include a 3 inch thick cement patch. This temporary repair shall be reinspected by the Coast Guard and ABS every thirty days until permanent repairs are made during February 2019 drydock. The vessels captain shall log a weekly inspection of the temp. repair attesting to its watertight integrity.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 February 2019
Resolved 19 December 2018
Resolution: Permanent repairs completed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2018 Resolved
Vsl is broadcasting Invalid Call Sign
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 October 2018
Resolution: Vessel's call sign was updated. AIS is broadcasting properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 July 2018 Resolved
Emergency generator did not take and hold electrical load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 Resolved
STBD MDE Local Emergency stop did not operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 12 July 2018 Resolved
The Fuel transfer pump emergency pump shut down did not operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 12 July 2018 Resolved
OWS <15ppm soliniod controled valve not seating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2018
Resolved 17 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 July 2018 Resolved
Provide/Demonstrate operation of the reverse power relay for SSDG(s)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2018
Resolved 6 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Secure loose wire at bilge pump pecker head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2018
Resolved 6 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
hard wire permanently installed fanse vice current plugs in E/r and Emergency Steering Comp.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2018 Resolved
Obtain approved plans for hydraulic modifications including bulkhead and deck penetrations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2018
Resolution: System tagged out and not used.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 July 2018 Resolved
Repair/Replace aft deck rail to meet Load Line requirments.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2018 Resolved
Stability; Address all weights added removed since last light ship. Specifically, aft bullworks and "H" frame installation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 July 2018 Resolved
STBD AZPOD indicator on the bridge to Emergency steering station is off by 5-15 degs. Needs calibration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 July 2018 Resolved
Replace STBD inboard embarkation area deck light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 August 2018
Stability › Incline Test › General
Issued 19 October 2017 Resolved
Obtain updated lightship change form from ABS for the addition of the steel bulkhead/framing on the main deck, stbd side by 16 Dec 2017.
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 4 June 2018
Resolution: ABS letter issued 26FEB2018, Ref T1721337/YH. Stability letter remains valid.
Lifesaving › Immersion Suits › Not on Board
Issued 30 August 2017 Resolved
Vessel to provide immersion siuts for Total Persons allowed (31). Vessel currently only has 09 onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 12 July 2018
Engineering › Pressure Vessel › Marking and Stamping
Issued 18 August 2017 Resolved
Make engine room air receiver available for internal examination. Air receiver shall be removed from service until examination is completed to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 1 September 2017
Resolution: Conducted internal inspection and tested relief valve.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 29 June 2017 Resolved
obtain all submitted plan approvals prior to commercial operations
Action required: 705 - Other - as specified
Resolved 20 July 2017
Resolution: Verified current approval letter for VRP.
Lifesaving › Lifebuoys › Size
Issued 12 July 2012 Resolved
Replace deck buoys on bridge wings w/ bridge buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2012
Resolution: New bridge buoys installed on bridge wings.
Lifesaving › Lifebuoys › Approval
Issued 12 July 2012 Resolved
Replace six lifebuoys which had no visible CG approval number with new CG approved lifebuoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2012
Resolution: Six new lifebuoys placed on board.
Operations/Management › Drills/Instruction › Fire
Issued 26 April 2007 Resolved
Crew not familiar with the use of the Flame Safey Lamp.
Due 26 May 2007
Resolved 9 May 2007
Resolution: Report received of crew training.
Communications › Radio Communications › EPIRB
Issued 18 July 2006 Resolved
Renew EPIRB Antenna.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2006
Resolved 18 July 2006
Resolution: Renewed Antenna.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 18 July 2006 Resolved
Renew reflective tape in proper position on starboard main deck life ring.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2006
Resolved 18 July 2006
Resolution: Repositioned/renewed tape.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 15 August 2005 Resolved
Provide proper fixed containment for Emerg, generator and port and stbd foot seal vents and port rail connections.
Condition: Design Flaw
Due 5 April 2007
Resolved 15 August 2005
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 4 September 2003 Resolved
Repair #2 generator reverse power relay.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 4 September 2003
Electrical › Lighting (emergency)
Issued 4 September 2003 Resolved
Install blanks in electrical panel in engine room. LEGACY COMPONENT DESC: blanks
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 4 September 2003
Engineering › Fuel Oil Service System
Issued 4 September 2003 Resolved
Install chaffing gear on fuel lines in engine room. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2003
Resolved 4 September 2003
Lifesaving › Line-Throwing Appliances
Issued 29 August 2002 Resolved
Provide 1500 ft. of messenger line for the impulse line throwing apparatus. LEGACY COMPONENT DESC: Lines
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2002
Resolved 30 August 2002
Electrical › Electric Supply System (service)
Issued 29 August 2002 Resolved
Provide proper location for storage and charging of batteries currently located in A/C space on 02 deck, IAW 46 CFR 129.356 and 46 CFR 111.15-10. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 September 2002
Resolved 4 September 2003
Resolution: Battery location 835 was appealed by Edision Chouest Offshore and granted by [name withheld] of D-8 on August 8, 2003.
Construction/Loadline › Penetrations › Valve Flange
Issued 3 April 2002 Resolved
REPLACE BALLAST OVERBOARD CHECK VALVE DUE TO WASTAGE ON FLAP
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Construction/Loadline
Issued 28 July 2000 Resolved
At next drydock make permenant repairs to port side shell IWO port potable water tank. Doubler (6" x 12") is covering hole in side shell approximately 12' aft of potable water fwd blkhd and 14" below main deck. Repairs shall be made to the satisfaction of the attending marine inspecto
Condition: Unknown
Due 1 August 2002
Resolved 3 April 2002
Engineering
Issued 30 July 1997 Resolved
PROVE PROPER OPERATION OF TUNNEL THRUSTER RPM GAUGE IN PILOT HOUSE.
Condition: Unknown
Due 30 August 1997
Resolved 18 August 1997
Engineering
Issued 30 July 1997 Resolved
PROVE PROPER OPERATION OF DROP DOWN THRUSTER PROP RPM GAUGE ON FWD STATION AND ENGINE RPM GAUGE ON AFT STATION.
Condition: Unknown
Due 30 August 1997
Resolved 18 August 1997
Deck/Cargo
Issued 30 July 1997 Resolved
PROVE PROPER OPERATION OF PILOT HOUSE FUEL OIL CARGO PUMP PRESSURE GAUGE.
Condition: Unknown
Due 30 August 1997
Resolved 18 August 1997
Electrical
Issued 30 July 1997 Resolved
PROVE PROPER OPERATION OF OVERCURRENT AND OVER FREQ TRIP FOR MAIN SWITCH BOARD.
Condition: Unknown
Due 30 August 1997
Resolved 18 August 1997
Lifesaving
Issued 30 July 1997 Resolved
INSTALL AND PROVE PROPER OPERATION OF AN ADJUSTABLE HEIGHT RESCUE PLATFORM.VESSEL DRAFT IS RESTRICTED FROM 10.5 FEET TO SUMMER LOADLINE UNTIL REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Navigation
Issued 30 July 1997 Resolved
PROVE PROPER OPERATION OF GMDSS UPS UPON LOSS OF MAIN POWER WITHOUT LOSS OFTRANSMISSION.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Deck/Cargo
Issued 30 July 1997 Resolved
REPLACE PORT AND STBD ANCHORS, ANCHOR CHAIN AND WINCH WILDCAT TO THE SATISFACTION OF ABS RULES FOR ANCHOR SIZE.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997

Casualty record · 2

17 January 2009Routine · role: Involved in a Marine Casualty · activity 3401893
8 April 2011Routine · role: Involved in a Marine Casualty · activity 3984987
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

C - COMMANDER (2009–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.