Records from 1985 to 2025. Most recent: inspection, 8 July 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 66
8 July 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8173003
23 May 2025
Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8142470
29 January 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088624
11 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8009305
12 October 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7798475
25 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7641065
9 June 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444604
18 October 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7331300
30 September 2021
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7323829
19 May 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7199965
13 July 2020
Internal Structural Exam · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6993554
9 June 2020
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6968009
10 October 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6827229
7 May 2019
Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6670916
17 September 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6534797
26 October 2017
Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6291631
25 May 2017
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6152275
14 October 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6018282
6 March 2014
Examination of Repairs · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4811158
13 December 2011
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4207494
28 September 2011
Excursion Permit · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4156616
15 August 2011
Re-Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4116488
4 January 2010
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3658448
26 September 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3225898
26 July 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2998094
10 May 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2915902
9 June 2005
Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2377123
13 May 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2366161
28 April 2005
Simplified Stability Test
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2332243
23 September 2003
Construction Oversight · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1907725
27 February 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1749666
10 January 2003
Type not recorded
No type recorded · USCGC CHINOOK (WPB 87308) · USCG Heartland District (CGD-H) · Activity 1745362
22 July 1999
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1103953
7 May 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1442805
14 October 1997
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1110519
8 October 1997
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1109401
19 February 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1094858
1 May 1996
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1380494
26 April 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 866378
3 March 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858947
3 May 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 858549
25 April 1994
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1170481
12 April 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168055
10 May 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1139919
30 April 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1150130
28 October 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 943786
22 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1255292
22 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1267600
5 May 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1254152
30 April 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1261222
25 April 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932671
5 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1238782
11 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1230734
17 October 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349441
3 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897916
12 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 890496
29 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1345701
3 November 1987
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328293
3 November 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328633
26 October 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1021603
24 September 1987
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007894
4 September 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1003679
8 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1331469
25 April 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 999636
13 March 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 992348
1 May 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 979418
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 January 2025
Resolved
Vessel is overdue for wood fastener pull, originally due on 31MAY2024. Conduct fastener pull prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2025
Resolution: Vessel allowed to operate until Monday 26May25 following satisfactory drydock.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 October 2024
Resolved
FCC Radiosafety Telephony Certificate expired.
47 CFR 80
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2024
Resolved 6 November 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 October 2024
Resolved
All cable and wire must not be installed with sharp bends. Properly secure cable in forward cabin so it does not have sharp bends.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2024
Resolved 6 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2024
Resolved
A vessel must be provided with an auxiliary means of steering that is of adequate strength; capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds with vessel at one-half its maximum service speed ahead or 7 knots, whichever is greater. A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to cognizant OCMI. Vessel did not have its hand tiller on board. Find or replace hand tiller.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2024
Resolved 6 November 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 October 2023
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Found multiple wire runs through the engine space bulkheads that will need to be properly sealed.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 October 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 October 2023
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD on board vessel was expired.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 October 2023
Resolved
A vessel on a Lakes, Bays and Sounds route must carry 03 hand red flare distress signals in accordance with 46 CFR 160.021 and 03 hand orange smoke distress signals in accordance with 46 CFR 160.037. May substitute hand red flares for hand orange smoke distress signals. Vessel only had 04 hand red flare distress signals.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 October 2023
Resolved
On a vessel of at least 26 feet in length, a visual & audible alarm must be provided at the operating station
to indicate high level. High water alarm inoperable at
the operating station.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2023
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from 02 sources of electricity: the vital systems listed in 46 CFR 182.710, which includes the bilge system. Vessel's high water alarm system is currently powered by two 9V batteries and has no secondary source of power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 10 December 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
Flexible hose designed for use with hose clamps may be installed with 02 clamps, at both ends of the hose. Flexible hoses on engines did not have double clamps.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2023
Resolved
The owner, managing operator or a qualified servicing facility as applicable shall conduct the inspections and tests for portable and fixed fire extinguishes and provide satisfactory evidence of the required service to the marine inspector. Vessel had 02 extinguishers with service tags of the year 2021 on them (01 extinguisher and fireboy had year 2023 tags) and no fire certificate to prove all extinguishers on board were inspected within past year.
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 12 October 2023
Resolved
Vessel owner stated lobster box & lobster pot crane were removed from vessel. Determine total amount of weight removed & provide to CG marine inspector, to determine if Simplified Stability Test is required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2023
Resolved 28 March 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 9 June 2022
Resolved
Operations of transmitters of any ship station must be performed by a person who is on duty at the control point of the station. Vessel master needs to have marine operators permit.
47 CFR 80.155
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2022
Resolution: Master passed marine operator's permit test
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 June 2022
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2" high: "EMERGENCY EXIT, KEEP CLEAR". Hatch in forward compartment not properly marked.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2022
Resolution: Emergency escape marked
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 June 2022
Resolved
Must have means to shutdown ventilation for pre-engineered fixed fire extinguishing systems. Engine space has 2 access holes that need to be secured in the event of fire & activation of the system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2022
Resolution: Holes secured
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2021
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material as specified in IMO Resolution A.658(16). Ring life buoy does not have retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 13 July 2022
Resolution: Retro-reflective tape properly placed on life buoy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2021
Resolved
A vessel 26' to 65' carrying not more than 49 passengers must have bilge pumps in accordance with table 182.520(a). Vessel has a fixed power bilge pump which partially meets the requirements but does not have a 10 GPM portable hand pump.
Vessel has three submersible electric pumps that are not in compliance with UL 1113. Remove or replace three bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2021
Resolved 9 June 2022
Resolution: Proper bilge pump installed
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 October 2019
Resolved
Drills not completed due to sever weather under way. Drills to be completed prior to passenger service in spring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 13 July 2020
Resolution: drills conducted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 September 2011
Resolved
Renew E/R bilge high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2011
Resolved 6 October 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 January 2010
Resolved
Vessel is restricted from carrying passengers until it completes a reinspection to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 25 June 2010
Resolution: Completed COI inspection on 25June2010.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 26 September 2008
Resolved
Post emergency instructions in pilot house.
Action required: 705 - Other - as specified
Due 10 October 2008
Resolved 10 October 2008
Resolution: Emg instructions posted.
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2008
Resolved
Replace lifering due to deteriorating polypropylene around outside of ring.
Action required: 705 - Other - as specified
Due 10 October 2008
Resolved 10 October 2008
Resolution: Lifering replaced.
Engineering › Bilge Water Management System › Pump
Issued 26 July 2007
Resolved
Prove proper operation of fixed bilge pump system.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 16 August 2007
Resolution: Witnessed proper operation of fixed bilge pump system.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 July 2007
Resolved
Tighten or replace packing gland on propeller shaft as needed.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 16 August 2007
Resolution: Witnessed leak at packing gland to be satisfactorily minimized.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 26 July 2007
Resolved
Prove acceptable means of providing the written count of all passengers at an acceptable ashore location.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 16 August 2007
Resolution: Witnessed newly installed mailbox on dock for pax count.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 July 2007
Resolved
Provide current up to date pubs and charts. Charts to reflect all areas transitted per COI.
Action required: 705 - Other - as specified
Due 10 August 2007
Resolved 16 August 2007
Resolution: Witnessed current up to date charts and pubs on board vessel.
Engineering › Freshwater System (cylinder head cooling) › Valve
Issued 9 June 2005
Resolved
Provide shut off valve for keel cooler penetrations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2005
Resolved 29 June 2006
Resolution: Valve installed on keel cooler penetrations.
Construction/Loadline
Issued 19 February 1997
Resolved
Get underway with marine inspector to check condition of hull._x001C_ _x001C_ To be completed prior to carrying passengers
Condition: Unknown
Due 1 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 19 February 1997
Resolved
Renew port side frame #4 from forward bulkhead in lazerette compartment.
Condition: Unknown
Due 1 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 19 February 1997
Resolved
Remove and renew rotted wood around lazerette hatch.
Condition: Unknown
Due 1 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 1 May 1996
Resolved
GET VESSEL UNDERWAY WITH MARINE INSPECTOR
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
RENEW REPAIR BROKEN FRAMES IN LAZERETTE COMPARTMENT IN ACCORDANCE WITH NVIC7-95. FRAMES PORT SIDE FROM FORWARD BULKHEAD #1,2,3,6,9 AND STARBOARD SIDE 1,4
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
RENEW LAZERETTE BILGE SUCTION HOSE
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
RENEW BROKEN ENGINEROOM FRAMES IN ACCORDANCE WITH NVIC 7-95. FRAMES PORT SIDE FROM AFT BULKHEAD #1,4,6,7,12
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 1 May 1996
Resolved
RENEW/ REPAIR ROTTED FRAMES IN FORWARD COMPARTMENT
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Construction/Loadline
Issued 12 April 1994
Resolved
REPAIR FOLLOWING BROKEN FRAMES. STEERING COMP. PORT #2,3,4,6 STBD #7,8,10 ENGINEROOM PORT #5,6,8 STBD #4,5,6,8,9 FORWARD COMPARTMENT STBD #1
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Lifesaving
Issued 30 April 1993
Resolved
PROVIDE AN ADDITIONAL 26 ADULT AND 1 CHILD'S LIFE PRESERVERS FOR INSPECTIONBY AN ATTENDING COAST GUARD MARINE INSPECTOR. UNTIL SUCH TIME, THE TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 25.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1992
Resolved
BECKETS FOR LIFELINES ON 7 PERSON AND 13 PERSON BUOYANT APPARATUS DETERIORATED. RENEW OR REPAIR BECKETS AS ORIGINAL.
Condition: Unknown
Due 5 May 1992
Resolved 8 May 1992
Navigation
Issued 30 April 1992
Resolved
PORT NAVIGATION LIGHT LENS DISCOLORED. BRING NAVIGATION SIDELITE INTO COMPLIANCE WITH USCG NAVIGATION RULES.
Condition: Unknown
Due 17 May 1992
Resolved 17 May 1992
Construction/Loadline
Issued 4 September 1987
Resolved
REPAIR 5TH, 6TH, 7TH, 10TH, & 13TH FRAMES FROM TRANSOM ON PORT SIDE. VESSELROUTE RESTRICTED TO NOT MORE THAN 10 MILES FROM HARBOR OF SAFE REFUGE & VOYAGES RESTRICTED TO NOT MORE THAN HALF DAY IN LENGTH UNTIL REPAIRS ARE MADE. COGNIZANT OCMI IS TO BE NOTIFIED FOR INSPECTION OF REPAIRS.
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987
Construction/Loadline
Issued 4 September 1987
Resolved
HAVE VESSEL HAULED FOR CREDIT DRYDOCK EXAMINATION
Condition: Unknown
Due 4 September 1987
Resolved 4 September 1987