Records from 2006 to 2025. Most recent: inspection, 17 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
17 November 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8270006
16 October 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8254731
12 December 2024
ACP Periodic Oversight · Periodic Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8047202
2 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042332
3 May 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7908006
19 December 2023
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7840601
12 December 2022
ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7607780
27 August 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7300290
23 August 2021
ACP COI Oversight · Deficiency Check · Re-Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7294444
26 October 2020
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7084653
31 August 2020
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7047177
13 November 2019
ACP Annual Oversight · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6854382
22 September 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6819990
19 September 2019
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816102
13 November 2018
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6580085
11 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6559010
12 September 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6539822
8 September 2018
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6537324
16 October 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6285937
15 September 2016
Re-Inspection · ACP COI Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6001807
23 June 2016
Administrative Inspection · ACP COI Oversight
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5917895
16 June 2016
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5910127
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Breaker directory in dishwashing space PWR PNL GALLERY COMMISSARY EQUIP #15-12 is not current and requires renewal.
74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 13 January 2025
Resolution: Accepted photo for updated directory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 December 2023
Resolved
Every oil fuel suction pipe from a storage, settling or daily service tank situated above the double bottom shall be fitted with a cock or valve capable of being closed from outside the space concerned in the event of a fire arising in the space in which such tanks are situated. Reach rods for Port and Starboard F/O Settling Tanks in Engine Room found to be inoperable.
SOLAS 60 II/69(c)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 December 2023
Resolved
The construction of all doors and door frames in “A” Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame as far as practicable equivalent to that of the bulkheads in which the doors are situated. Lower fire-resistant gasket is missing on the following fire doors: Emergency Diesel Generator Room, Accommodation Space Engine Room Access.
SOLAS 60 II/38
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2024
Resolved 28 February 2024
Resolution: Accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2023
Resolved
Where pipes, scuppers, electrical cables are carried through watertight subdivision bulkheads, arrangements shall be made to ensure the integrity of the watertightness of the bulkheads. 02 watertight cable penetrations (MCTs) in the lower level of the Engine Room penetrating the main transverse watertight bulkhead found to be improperly installed.
SOLAS 60 II/13(b)(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2024
Resolved 8 January 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 December 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port Gas Turbine Enclosure access doors are missing lower gaskets preventing a gas-tight seal for the CO2 protected space.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2024
Resolved 28 February 2024
Resolution: Accepted by ABS.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 December 2023
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Stbd aft life raft station found with painted over releasing hooks for the chains covering the launching area.
74SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 February 2024
Resolution: Accepted by ABS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 December 2023
Resolved
Goods which give off dangerous vapours shall be stowed in a well ventilated space or on deck. Vessels ro-ro cargo hold fans 3S and 6P were found inoperable/malfunctioning.
60SOLAS VII/Reg.7(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 January 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 December 2023
Resolved
An aggregate of more than 7.6 liters (two gallons) of flammable or combustible liquids stowed outside of an accommodation, control, or service, space (other than a paint locker) or outside of a machinery space must be stowed in a paint locker that is marked with a warning sign indicating flammable or combustible liquid storage. Hundreds of gallons of paints and a cabinet of spray paints were found stored outside of the ships paint locker.
46CFR147.45(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 February 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 December 2023
Resolved
Each portable container of flammable or combustible liquid used for portable auxiliary equipment must be stowed in a paint locker or an open location designated by the master. Portable fuel oil containers found throughout the tween deck.
46CFR147.45(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 February 2024
Resolution: Accepted by ABS.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 19 December 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2024
Resolution: Verified presence of valid MMCs for listed personnel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 December 2023
Resolved
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks.. satisfactory means, permanently attached, shall be provided for closing the openings of the air pipes. Multiple tank vent pipes on the main deck were found to have broken or missing closing devices.
ICLL Reg 20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 January 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 December 2023
Resolved
The construction of all doors and door frames in “A” Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame as far as practicable equivalent to that of the bulkheads in which the doors are situated. Machinery casing opening on the port side of the upper tween found with damaged gasket and 02 2” openings without closing devices.
SOLAS 60 II/38
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 February 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 December 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessels paint locker found disorganized with open containers, electrical cords and equipment and blocked access to lighting and firefighting appliances due to the high stacking of containers.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 February 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 December 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel found storing hazardous stores and debris on the tween deck on either side of the only entry/exit to the vessel. No additional firefighting appliances provided in the area and the area is undesignated as a hazardous storage area.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 January 2024
Resolution: Accepted by ABS.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 December 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. 1. Deterioration found on framing adjacent to fire extinguisher #54
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 January 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 December 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire station 20 found missing required nozzle for the fire hose.
74SOLAS (20) II-2/14.2.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 December 2023
Resolution: The missing nozzle was found and placed back on station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 December 2022
Resolved
All dead-end lines shall extend at least 2 inches beyond the last orifice and shall be closed with cap or plug. CO2 line in upper paint locker terminates at discharge horn and does not have a 2 inch extension.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 15 December 2022
Resolution: Accepted photos showing addition of piping past discharge horn.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 August 2021
Resolved
After any survey of the ship under Regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. The visual and audible alarm on the #3 SSDG overspeed shutdown was inoperable. 60 SOLAS I/11.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2021
Resolution: Received class finding no.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 October 2020
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel does not have an FCC Station License onboard.
47 CFR 80.13(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 December 2020
Resolved 16 January 2021
Resolution: Vessel provided FCC letter suggesting exemption for government shipping.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 November 2019
Resolved
Separation of the accomodation spaces from the remainder of the ship by thermal and structural boundaries. Port bridge wing Air Conditioner pipe pentrations in port bridge bulkhead are exposed to open atmosphere (crew described a metal plate to maintain fire boundary was missing).
SOLAS 60 II/34(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2019
Resolved 15 November 2019
Resolution: Received photo from vessel rep showing metal plate reaffixed. Class has accepted finding 1082.Closed during 20 MAR 2020 class survey.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 13 November 2018
Resolved
Except as specified in paragraph 3 of this regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. Installed OWS is not currently operational. The OWS may not be used until a satisfactory operational test is witnessed. If the vessel is activated prior to correction of this deficiency, documentation must be submitted to prove that there is sufficient holding tank capacity available for expected operations without the use of the OWS. MARPOL I/14.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a gap in the fuel containment under the port gas turbine air intake such that a fuel leak would drain into the machinery room below rather than into the drain as designed. 74SOLAS(14)I/11
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 13 November 2018
Resolved
Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of the subpart. The plan must include: actions for implementing the mandatory BWM requirements and practices. The current BWM Plan does not reflect the company's policy of only ballasting with fresh water from a U.S. public water system. Update the BWM Plan to reflect the company's policies. 33CFR151.2050(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Two lifebuoys on aft main deck were found damaged. Replace damaged lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 November 2018
Resolved
Where "A" class divisions are penetrated for the purpose of electrical cables, pipes, trunks ducts, etc, arrangements shall be made to ensure that the fire resistance is not impaired. A/C cables penetrating aft side of pilot house, which is classified as an "A" class boundary, is not properly sealed to meet structural fire protection standards. Install proper fire protection to meet "A" class boundary standards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2018
Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. Aft upper mast light is in operable. Demonstrate satisfactory operation of mast light. SOLAS V/16.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 21 November 2018
Resolution: Cleared IAW CVC-PR-001.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 October 2018
Resolved
NAME: Vsl is broadcasting incorrect Name,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 November 2019
Resolution: Witnessed vsl nsme and data fields on AIS during Sector San [name withheld] annual inspection 13NOV2019, sat.