MAURY USCG vessel records Sign in
← All vessels

CYCLONE

CYCLONE is a 1997 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1997, most recently in May 2026, along with 49 deficiencies.

Records from 1997 to 2026. Most recent: inspection, 7 May 2026.

Built
1997
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6905
457160
Flag
UNITED STATES
367561880
Maury page id
psix-457160

Inspections, by type

Years with a record 24 calendar years (1997–2026)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.7 ft × 18.2 ft × 6.0 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOCEAN ROCKETS INC · TUCKAHOE, NJ, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portAVALON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6523MMSI 367475150 · cancelled · compulsorily equipped · granted 30 October 2020, cancelled 29 October 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDJ4898MMSI 367561880 · active · compulsorily equipped · granted 12 April 2017, expires 12 April 2027
WDG6905MMSI 367561880 · cancelled · compulsorily equipped · granted 8 February 2013, cancelled 22 February 2017
WDA3190MMSI 366795620 · expired · compulsorily equipped · granted 23 December 2000, cancelled 26 February 2011 · licensed under a name not among this hull’s recorded names (not shown)
WCY9767MMSI not assigned · cancelled · compulsorily equipped · granted 8 April 1999, cancelled 19 May 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCX5602MMSI not assigned · expired · voluntarily equipped · granted 19 June 1997, cancelled 19 August 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

7 May 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8295890
20 May 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047110
3 February 2025 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046766
13 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8047087
17 June 2024 Annual Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883688
2 April 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888775
1 June 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7670987
14 February 2023 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622653
27 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436011
24 February 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7145291
12 August 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7032441
1 July 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6992981
17 July 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732756
26 February 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6616718
11 December 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6599002
20 July 2018 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6512334
20 June 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414229
3 May 2018 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6409192
5 April 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6118229
31 January 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6063995
27 January 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4233219
14 April 2009 Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3453257
28 June 2008 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3252753
13 June 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3235950
12 April 2007 COI Inspection · MARPOL Annex I Examination · Internal Structural Exam · Hull Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2906361
12 June 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2679552
2 June 2005 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2376586
21 April 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2339500
3 June 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2088415
9 June 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1813403
1 May 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1792884
6 May 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1613607
2 May 2001 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1366318
16 April 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1395681
3 May 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1458751
7 May 1999 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365206
14 April 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 790863
10 August 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 796747
20 October 1997 MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777102
10 June 1997 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1112000

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2024 Resolved
On a vessel of not more than 65 ft in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump is not able to produce over 60 psi. 46 CFR 181.300 (b) 29JAN2025 - Changed to 705: Prior to credit drydock
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 July 2024
Resolved 6 March 2025
Resolution: Fire pump psi produced over 60 psi.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
Conductors in power and lighting circuits must be No. 14 American Wire Gauge or larger. Engine room wiring for blowers and lights installed in 16AWG. 46 CFR 183.340 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 1 August 2024
Resolution: Received proof of repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
All fuel tanks must be electrically bonded to a common ground. Port fuel tank bonding wire found corroded. 46 CFR 182.440 (b) (4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 1 August 2024
Resolution: Received proof of repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
All metallic enclosures and frames of electrical equipment must be permanently grounded to the hull on a metallic vessel. On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Multiple grounding connections in Laz space had corroded and no longer bonding metallic enclosures. 46 CFR 183.372(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 1 August 2024
Resolution: Received proof of repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wires found in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2024
Resolved 1 August 2024
Resolution: Received proof of repair.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 June 2024 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. Vessel does not have rudder stops installed. Vessel is to rectify at next dry dock. 46 CFR 182.610 (e)
Action required: 705 - Other - as specified
Resolved 21 February 2025
Resolution: Installed rudder stops to prevent jamming and damage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Aft portside stanchion in engine room that supports the deck frames was found cracked at weld. Vessel is to rectify at next dry dock. 46 CFR 177.100(a)
Action required: 705 - Other - as specified
Resolved 21 February 2025
Resolution: Vessel istalled a metal bracket to support stanchion. Welding the stanchion was not possible due to wood framing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The belt and rotating machinery of the port engine, inboard side, was found to be missing a cover or guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 6 May 2022
Resolution: Vessel owner provided photographic evidence of cover/guard on the port engine.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 April 2022 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. The vessel's whistle was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 28 May 2022
Resolution: Vessel owner sent a video to marine inspectors attesting to the proper operation of the ship's whistle.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 17 July 2019 Resolved
Each Vessel that operates on the high seas or operates 3 miles from the coastline of the great lakes must have onboard a category 1 406 MHz EPIRB. EPIRB battery expired 4/19. Replace EPIRB battery. Vessel route is restricted to no more than 3 miles from the shoreline of Catalina island.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 August 2020
Resolution: Fitted with a new EPIRB properly registered. Verified on annual inspection.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 June 2018 Resolved
Replace out of service lifejackets. Passenger count reduced to 83.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 20 July 2018
Resolution: Vessel provided 128 serviceable adult lifejackets and 50 serviceable child lifejackets.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 20 June 2018 Resolved
Tighten loose CO2 bottle discharge head in accordance with manufacturers recommendations.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 June 2018
Resolved 20 June 2018
Resolution: Discharge nozzle was tight and secured.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 20 June 2018 Resolved
Conduct annual servicing on all Inflatable Buoyant Apparatus's. Route is restricted to 3 miles.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2018
Resolved 14 December 2018
Resolution: Vessel is restricted to operating within 3nm of shore.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2017 Resolved
Provide guards on front of engine.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 5 April 2017 Resolved
Provide overboard discharge lock for sewage overboard valve.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Fire Fighting › Nozzles › Number
Issued 5 April 2017 Resolved
Provide nozzle for firehose
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 April 2017 Resolved
provide DAPI manual and DAPI crew list
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Operations/Management › Drills/Instruction › Safety Orientation
Issued 5 April 2017 Resolved
Provide passenger safety orientation.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 April 2017 Resolved
Provide lifejacket placards with the number of lifejackets listed.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Documentation › Logs/Records › Logbook (official)
Issued 5 April 2017 Resolved
Provide passenger count with log for all future charters (embarkation/disembarkation).
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2017 Resolved
Conduct fire, MOB, abandon ship drills with the crew.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 26 April 2017
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017 Resolved
ROTTED WOOD VIC OF MIDSHIP HATCH
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 28 March 2017
Resolution: REPAIRED
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017 Resolved
ROTTED WOOD IN VIC OF AFT HATCH
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 28 March 2017
Resolution: REPAIRED
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 31 January 2017 Resolved
PROVIDE REPORT OF PORT PROPELLER
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 28 March 2017
Resolution: Report provided, props serviced
Construction/Loadline › Hull › Weld
Issued 14 April 2009 Resolved
Make repairs to cracked/fractured welds IWO vsl’s aft platform, as marked.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Repairs completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2009 Resolved
Make repairs to railing IWO vsl’s aft platform.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Railed repaired.
Construction/Loadline › Hull › Bracket
Issued 14 April 2009 Resolved
Make repairs to stbd aft stanchion in engine compartment.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Stanchion repaired.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 14 April 2009 Resolved
Make repairs to cracked welds in vessel seats, as marked.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Cracks welded.
Construction/Loadline › Structures › Deck Plating
Issued 14 April 2009 Resolved
Provide screws to deck seats in stbd aft area, as marked.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Screws provided.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2009 Resolved
Make repairs to cracked welds for vsl railings (03), as marked.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Cracks welded.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2009 Resolved
Provide screws for vsl railings (04), as marked.
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 1 May 2009
Resolution: Screws provided.
Construction/Loadline › Hull › Hull Plating
Issued 13 June 2008 Resolved
Drydock vessel to re-install trim tab screws. Re-seal all through fittings in lazarette.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2008
Resolution: New screws installed. No leaking noted inside.
Engineering › Bilge Water Management System › Piping
Issued 13 June 2008 Resolved
Replace bilge hose for electrical pump in lazarette.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 17 June 2008
Resolution: Hose replaced and satisfactorily tested.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 June 2008 Resolved
Repalce non-skid on bridge ladder.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 17 June 2008
Resolution: All non-skid replaced.
Construction/Loadline › Hull › Bracket
Issued 12 April 2007 Resolved
Make proper repairs to cracked rudder, port side.
Action required: 705 - Other - as specified
Resolved 23 April 2007
Resolution: Received photos of rudder repair.
Construction/Loadline › Hull › Hull Plating
Issued 12 April 2007 Resolved
Make proper repairs to cracked stern tube, stbd side.
Action required: 705 - Other - as specified
Resolved 23 April 2007
Resolution: Recieved photos of fiberglass repair.
Construction/Loadline › Hull › Weld
Issued 12 April 2007 Resolved
Repair all cracked welds on all seats.
Action required: 705 - Other - as specified
Resolved 23 April 2007
Resolution: Welds repaired.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 12 June 2006 Resolved
Vessel does not have two independent means of power supply. Replace dead battery bank and prove means of operating power supply to the satisfaction of the attending CG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2006
Resolution: Installed new battery bank. MI witnessed startup from both battery banks.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 June 2006 Resolved
Replace retro-reflective tape on 21 child life preservers.
Due 26 June 2006
Resolved 12 June 2006
Resolution: Retro-reflective material applied on-site.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2006 Resolved
Provide updated navigation pubs. None onboard vessel
Due 26 June 2006
Resolved 12 June 2006
Resolution: Reed''s publication provided on location.
Electrical › Lighting (service)
Issued 6 May 2002 Resolved
Replace missing light guard in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 16 May 2002
Resolved 6 July 2002
Resolution: Cleared based on phoncon between [name withheld] and Gus Markou.
Lifesaving
Issued 2 May 2001 Resolved
Provide replacement first aid kit w/ up to date medication (fax receipt).
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 2 May 2001 Resolved
Repair and prove proper operation of e/r high level alarm.
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Accommodation/Occupational Safety
Issued 2 May 2001 Resolved
Install MSD strapping for tank (loose).
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 16 April 2001 Resolved
Fore peak: #2 transverse stiffener IWO center line, open area and inspect water intrusion and wastage of core material. Renew as necessary. Provide report of findings._x001C_ _x001C_
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 16 April 2001 Resolved
Lazerrette: Remove center stanchion IWO main deck. Renew over head in area.Ensure transom is inspected for wastage or water intrusion, gouge out to good if necessary.
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Engineering
Issued 7 May 1999 Resolved
Install machinery guard over stbd alt & belts
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Navigation
Issued 7 May 1999 Resolved
Install illuminated magnetic compass
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Fire Fighting
Issued 7 May 1999 Resolved
Replace existing piping with approved A53 Grade A or B, A106 Grade A, B, orC, or equivalent. Existing piping is A53F and not approved for service in system
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.