MAURY USCG vessel records Sign in
← All vessels

THOMAS E. LANNON

THOMAS E. LANNON is a 1997 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1997, most recently in June 2026, along with 15 deficiencies and 2 operational controls.

Records from 1997 to 2026. Most recent: inspection, 16 June 2026.

Built
1997
Last inspected
16 June 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY6747
457166
Flag
UNITED STATES
367374710
Maury page id
psix-457166

Inspections, by type

…with no type recorded2
Years with a record 25 calendar years (1997–2026)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.5 ft × 17.5 ft × 8.0 ft
Registered tonnagegross 45 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSALT MARSH CHARTERS · ESSEX, MA, UNITED STATES · built 1997
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY6747MMSI 367374710 · active · compulsorily equipped · granted 13 July 2018, expires 1 September 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

16 June 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8397267
16 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8332009
17 June 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8157078
27 January 2025 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8160436
8 July 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7953926
9 April 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7877043
5 June 2023 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7692125
27 June 2022 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7489383
2 June 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7457514
20 April 2022 In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7414157
16 November 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7344796
22 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7232801
22 July 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7012209
3 June 2020 Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6967021
31 March 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6933606
28 May 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6697111
14 June 2018 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6442261
23 May 2018 Deficiency Check · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6394979
20 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6395759
7 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6168711
8 June 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5900139
18 May 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5880338
8 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5849265
8 June 2012 Inclining Experiment
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4349244
13 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207366
11 July 2011 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4078694
5 October 2010 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3863562
3 July 2008 Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3255812
11 April 2008 Administrative Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3181882
19 July 2007 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3000331
2 May 2006 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2638405
1 May 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2637913
28 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2610946
2 July 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2118467
1 April 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2035227
15 July 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1846229
3 April 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1767614
16 September 2002 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1676540
9 September 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1680634
28 June 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1362365
13 April 2001 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1432498
27 June 2000 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384491
19 August 1999 Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 782656
8 April 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1122925
19 August 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1130880
18 July 1997 Deficiency Check · Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779977

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2021 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operations, in which case no floating waterlight is required. The waterlight was inoperable. Vessel is limited to daylight operations until the waterlight is functional.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 June 2021
Resolution: Owner purchased a new battery and submitted photos of battery, receipt and waterlight floating in water.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2021 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The 10-B:C extinguisher by the operating station has not been serviced this year.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
Resolution: Owner provided photo of new 10-B:C extinguisher and receipt.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 23 May 2018 Resolved
07110- Provide 10-B:C fire extinguisher. 46 CFR 181.400 701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2018
Resolution: A new fire extinguisher was installed behind the operation station.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2017 Resolved
FCC Safety Cert was expired (47CFR80)
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 8 June 2017
Resolution: Rcvd FCC Safety Cert
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011 Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 45 PERSONS (PASSENGERS AND CREW) 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 2 August 2012
Resolution: New stability letter issued by MSC.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2006 Resolved
The THOMAS E. LANNON (O.N. 1054110) was found to be operating during the 2005 summer season without a valid Certificate of Inspection (COI) on board. The COI expired on June 27, 2005 and has not been renewed. Prior to operation, complete a full COI exam to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2006
Resolution: Completed satisfactory COI exam.
Fire Fighting
Issued 28 June 2001 Resolved
Prior to carrying passengers, install a fixed gas fire extinguishing systemor, as an alternative, install a suitably-sized portable carbon dioxide (CO2) extinguisher in accordance with 46 C.F.R. 181.400(b)(5)(i) - (iii).
Condition: Unknown
Due 28 July 2001
Resolved 6 July 2001
Lifesaving
Issued 28 June 2001 Resolved
Prove proper operation of EPIRB. Vessel is limited to operations less thanthree (3) miles from shore until completed.
Condition: Unknown
Due 28 July 2001
Resolved 6 July 2001
Lifesaving
Issued 19 August 1999 Resolved
RENEW EPIRB'S REGISTRATION AND HYDROSTATIC RELEASE MECHANISM. VESSEL RESTRICTED FROM CARRYING PASSENGERS MORE THAN 3 MILES FROM LAND UNTIL CORRECTED.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Lifesaving
Issued 18 July 1997 Resolved
PROVIDE "AS BUILT", DETAILED MACHINERY, ELECTRICAL AND BILGE PIPING DIAGRAMS.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997
Lifesaving
Issued 18 July 1997 Resolved
CONDUCT TRAINING OF NEW CREWMEMBERS AND DEMONSTRATE UNDERWAY EMERGENCY DRILLS.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997
Electrical
Issued 18 July 1997 Resolved
INSTALL AN AUTOMATIC EMERGENCY LIGHT IN VICINITY OF TOILET SPACE AND CABIN LADDER.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997
Lifesaving
Issued 18 July 1997 Resolved
POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997
Lifesaving
Issued 18 July 1997 Resolved
PROVIDE DOCUMENTATION OF COMPLIANCE WITH CHEMICAL TESTING REGULATIONS FOUNDIN 46 CFR PART 16.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997
Documentation
Issued 18 July 1997 Resolved
APPLICATIONS HAVE BEEN MADE; PROVIDE PROOF OF ISSUANCE OF FCC RADIO STATIONLICENSE, RADIOTELEGRAPHY CERTIFICATE, AND MASTER'S OPERATOR'S LICENSE.
Condition: Unknown
Due 1 August 1997
Resolved 31 July 1997

Ownership record