Records from 1997 to 2007. Most recent: inspection, 19 June 2007.
Inspection history · 33
19 June 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2959285
15 June 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2962949
10 November 2004
Ballast Water Examination · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2238401
9 November 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2238113
5 November 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2236849
2 July 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2116078
24 April 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2051504
22 April 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2050677
20 February 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2011767
4 November 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1941910
28 October 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1937929
27 October 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1937481
18 February 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745953
7 February 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742291
21 January 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1732823
20 January 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1732636
13 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1732393
19 December 2002
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1722599
18 December 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1720762
20 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1708442
17 October 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1691979
4 October 2002
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1684559
3 April 2002
Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1600675
14 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290034
8 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 83415
24 April 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277204
24 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1048707
5 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417742
5 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128342
14 October 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 408896
25 June 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 405154
4 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404330
4 June 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1109793
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 June 2007
Resolved
This vessel was granted a deviation from the rules, allowing operation in the Sector New Orleans COTP zone with an inoperative radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2007
Resolved 21 June 2007
Resolution: Received Tech. report from G.A. [name withheld] stating the deficiency has been rectified.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 November 2004
Resolved
MSO PHILADELPHIA ISSUED LOD 45 - 04 TO T/V KURZEME FOR AN INOP S-BAND RADAR
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2004
Resolved 10 November 2004
Resolution: INOP S-BAND RADAR INSPECTED AND TESTED TO THE SATISFACTION OF THE REPAIR TECHNICIAN
Electrical › Electric Supply System (service)
Issued 28 October 2003
Resolved
Electrical cable in airlock not insulated. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 11 November 2003
Resolved 4 November 2003
Electrical › Electric Supply System (service)
Issued 28 October 2003
Resolved
Electrical heating cables for decontamination piping inoperative and several electrical heating wires exposed on main deck within gas hazard zone. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 28 November 2003
Resolved 23 April 2004
Resolution: CONDUCTED DEFICIENCY FOLLOW UP . NEW HEATING CABLES AND INSULATION INSTALLED ON MAIN DECK AREA.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 28 October 2003
Resolved
Several deck water spray nozzles inoperative above starboard manifold, deck cargo tanks, and aft compressor room bulkhead. LEGACY COMPONENT DESC: Nozzles
Action required: 705 - Other - as specified
Due 4 November 2003
Resolved 4 November 2003
Navigation › Collision/Grounding Avoidance
Issued 20 January 2003
Resolved
Vessel reported loss of secondary marine radar system. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2003
Resolved 21 January 2003
Resolution: Repairs made to secondary radar, test sat.
Documentation
Issued 14 October 1997
Resolved
Prior to departure from COTP Houston/Galveston zone, provide a valid Sub "O" endorsement IAW current certificate of fitness issued by DNV on 10SEP97.
Condition: Unknown
Due 14 October 1997
Resolved 15 October 1997
Deck/Cargo
Issued 4 June 1997
Resolved
PROVE PROPER OPERATION OF ELECTRIC LEVEL INDICATOR TO #3 CARGO TANK. REQUIREMENT MUST BE MET PRIOR TO 04 JULY 1997.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997