MAURY USCG vessel records
← All vessels

305-034

Built
1948
Last inspected
10 December 2002
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 10 December 2002
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1981–2002)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
27 - Regulatory (Subpart C or D), Gross Ton 27 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-45720
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

10 December 2002 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1717392
6 April 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 656479
2 February 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1059574
26 January 2001 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391496
9 December 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381411
15 June 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472519
17 December 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 656483
17 December 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416610
27 June 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380584
9 August 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880685
24 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880632
22 June 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459181
17 May 1994 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403789
13 July 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1156510
22 June 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 843215
23 June 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 959483
2 April 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912575
25 April 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920225
5 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217347
11 April 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349639
14 July 1987 Hull Examination · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021694
15 November 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293773
20 April 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970600

Deficiency record · 16

Navigation › Collision/Grounding Avoidance
Issued 10 December 2002 Resolved
Demonstrate proper operation of NAVLTS. LEGACY COMPONENT DESC: Navigation Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 10 December 2002 Resolved
Provide a minimum of two BII fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Engineering › Bilge Water Management System › Pump
Issued 10 December 2002 Resolved
Demonstrate proper operation of bilge/fire pump system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Stability › Unintentional Flooding
Issued 10 December 2002 Resolved
Replace gaskets on all void access covers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Lifesaving › Lifebuoys
Issued 10 December 2002 Resolved
Provide an adequate ring buoy with line and light attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Electrical › Electrical Distribution System (service) › Cable
Issued 10 December 2002 Resolved
Repair cable for NAVLT on portside corner.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Stability › Watertight Integrity
Issued 10 December 2002 Resolved
Repair cable penetration for NAVLT on stbd stern cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 December 2002 Resolved
Provide storage for (and properly label) child size life preservers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Fire Fighting › Fire Hoses › Condition
Issued 10 December 2002 Resolved
Replace fire hose and ensure it is properly tested.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2002
Construction/Loadline
Issued 26 January 2001 Resolved
PRIOR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF BILGE SUCION IN VOIDS 5,7,8.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Construction/Loadline
Issued 26 January 2001 Resolved
Present vessel for drydock exam.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Documentation
Issued 26 January 2001 Resolved
Present vessel for reinspection.
Condition: Unknown
Due 28 February 2001
Resolved 28 February 2001
Construction/Loadline
Issued 15 June 1998 Resolved
MAKE REPAIRS TO FRACTURES AND CROP AND RENEW STRUCTURAL MEMBERS AS MARKED.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Documentation
Issued 17 December 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Navigation
Issued 22 June 1995 Resolved
Provide marine type bulbs for all navigation lights, bow and stern. Vessel not to be operated until above item is completed._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1993 Resolved
MAKE PERMANENT REPARS TO 4" FRACTURE STBD SIDE DECK KNUCKLE @ STANCION BTWNFWD LIFE JACKET STORAGE & FIRE STATION, 2 CRACKED WELDS PORT SIDE ON SUPPORT FOR WOOD BUMPER @ DECK AND 2" FRACTURE IN RUB RAIL PORT SIDE FWD OFDRAFT MARKS.
Condition: Unknown
Due 13 July 1993
Resolved 10 August 1993

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.