ARGOSY VI

ARGOSY VI is a 1997 passenger vessel (inspected). The Coast Guard has recorded 122 inspections since 1997, most recently in November 2021, along with 87 deficiencies, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2020.

Records from 1997 to 2021. Most recent: operational control imposed, 4 November 2021.

Built
1997
Last inspected
4 November 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDD6105
457226
Flag
UNITED STATES
367168350 (licence lapsed)
Maury page id
psix-457226

Inspections, by type

…with no type recorded46
Years with a record 16 calendar years (1997–2021)
The 122 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it14679 - Convention (Subpart B), Gross Ton
1597 - Regulatory (Subpart C or D), Gross Ton
5027 - Convention (Subpart B), Net Ton
1200 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD6105MMSI 367168350 · expired · compulsorily equipped · granted 23 February 2007, cancelled 29 April 2017
WCX6951MMSI not assigned · expired · compulsorily equipped · granted 20 August 1997, cancelled 20 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 122

4 November 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7345561
17 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7097003
30 September 2020 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7068769
17 September 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7082934
9 February 2010 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3683711
14 May 2009 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3475600
12 February 2009 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3416805
13 November 2008 DAPI Audit · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3362450
11 September 2008 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3322524
7 August 2008 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3291777
14 May 2008 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3211610
14 February 2008 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3150454
16 November 2007 Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3099743
27 September 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071252
9 July 2007 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2989680
2 July 2007 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980866
7 May 2007 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2925203
26 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2896568
8 February 2007 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2868844
4 September 2006 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2807940
10 August 2006 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2742316
4 August 2006 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2764185
19 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2718190
19 July 2006 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2718201
18 May 2006 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2652225
15 February 2006 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2585770
8 February 2006 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2581409
3 November 2005 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2527153
3 November 2005 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2529951
10 August 2005 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2434114
11 July 2005 Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2405413
12 May 2005 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2355305
11 February 2005 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2287860
16 November 2004 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2242660
10 November 2004 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2236952
14 September 2004 Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2197970
10 August 2004 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2160725
10 August 2004 MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2162228
19 May 2004 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2071488
19 May 2004 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2076612
25 February 2004 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2012636
2 December 2003 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1957194
13 November 2003 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1947929
8 September 2003 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1901739
15 August 2003 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1876771
10 June 2003 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1814745
21 February 2003 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1748801
19 November 2002 Quarterly Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1709369
4 November 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1700584
21 August 2002 COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1665096
14 July 2002 Drydock Extension
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1650963
11 July 2002 Internal Structural Exam
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1650958
28 May 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1621849
26 February 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1491614
11 February 2002 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1610664
27 November 2001 Re-Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1426701
18 September 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1072961
23 August 2001 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1408817
8 August 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1069478
29 June 2001 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1067015
29 May 2001 Deficiency Check · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1399649
23 May 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1065838
1 May 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1065841
2 April 2001 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1062409
2 April 2001 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1362403
30 March 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 33741
26 February 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1370196
15 February 2001 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 150255
30 October 2000 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1436453
20 September 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1054588
30 August 2000 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1456889
30 May 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 141017
12 May 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1379111
26 April 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 528692
13 April 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 760179
1 April 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 208258
6 March 2000 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1046391
25 February 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 51781
25 February 2000 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1434994
23 January 2000 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 134737
6 December 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 812182
29 November 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1448050
16 October 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 147914
13 October 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 167331
13 September 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1338511
1 September 1999 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1388933
16 July 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 19656
29 June 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 47391
28 June 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1338355
24 June 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1365436
24 June 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1454716
12 April 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1123419
30 March 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 124757
30 March 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1121640
14 March 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 112429
9 March 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1399185
17 December 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1399184
9 December 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 66457
19 October 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 10092
12 October 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 84442
30 September 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 802702
11 September 1998 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1437594
6 August 1998 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1466004
4 August 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 17217
16 June 1998 Re-Inspection · Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1415052
10 June 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 47177
3 May 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 64072
25 April 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 70207
31 March 1998 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1372181
14 March 1998 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 84902
5 February 1998 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 773247
21 December 1997 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 56075
17 December 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1400691
18 November 1997 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 775792
14 November 1997 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 11306
11 November 1997 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 141055
3 November 1997 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 118235
20 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777167
2 October 1997 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1416579
20 September 1997 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 72638
20 September 1997 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 177706
11 September 1997 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431851

Deficiency record · 87

Stability › Watertight Integrity › General
Issued 7 May 2007 Resolved
Adjust watertight door # 1 and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2007
Resolution: Chief engineer adjusted door and proved proper operation.
Stability › Watertight Integrity › General
Issued 7 May 2007 Resolved
Reposition hand pump handle for # 1 watertight door and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2007
Resolution: Chief engineer repositioned handle and proved proper operation of same.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 May 2007 Resolved
Practice man overboard drill and add to ask person in water name and if any injuries.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2007
Resolution: Vessel personnel conducted another drill and asked persons name and if injured.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2007 Resolved
Prove proper operation of louvers for air handler unit #14.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Correc ted during course of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2007 Resolved
Prove proper operation of louvers for air handler unit # 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Corrected during course of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2007 Resolved
Prove proper operation of louvers for air handler unit # 19.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Corrected during course of inspection.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2007 Resolved
Prove proper operation of louvers for air handler unit # 23.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Corrected during course of inspection.
Fire Fighting › Fire Hydrants › Material
Issued 8 February 2007 Resolved
All fire hoses and fire axes need to be properly labeled with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 9 July 2007
Lifesaving › Lifebuoys › Serviceable
Issued 8 February 2007 Resolved
Repair or replace ring buoy on second deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Ring buoy replaced during course of inspection old ring buoy destroyed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 February 2007 Resolved
Prove proper operation of "E" light on second deck aft port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 8 February 2007
Resolution: Battery replaced, light operating.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 February 2007 Resolved
Prove proper operation of overspeed trip on # 3 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 14 February 2007
Resolution: Overspeed trip adjusted and tested satisfactory.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 February 2007 Resolved
Prove proper operation of overspeed on # 4 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 14 February 2007
Resolution: Overspeed trip adjusted and tested satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 August 2006 Resolved
Remove poker room cocktail carts from vessel they are a tripping hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2006
Resolved 10 August 2006
Resolution: Item was corrected day of inspection per phone con between [name withheld] & [name withheld] on August 30, 2006.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 4 August 2006 Resolved
Complete MIS submission for 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2006
Resolved 4 September 2006
Resolution: MIS submitted for 2005.
Communications › Alarms/Indicators › General Alarm
Issued 18 May 2006 Resolved
Prove proper operation of general alarm bell starboard side forward.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 18 May 2006
Resolution: Removed birds nest from inside bell, tested satisfactory.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 May 2006 Resolved
Install proper label on "E" lights.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: "E" lights labeled during course of inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 May 2006 Resolved
Install cover on junction box in overhead of high roller slots on third deck aft.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Cover installed prior to completion of inspection.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 18 May 2006 Resolved
Prove proper operation of high coolant temperature alam on # 6generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Sensor adjusted to proper temperature and tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 18 May 2006 Resolved
Prove proper operation of high coolant temperature shutdown on # 5 generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Sensor adjusted to proper temperature and tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 18 May 2006 Resolved
Prove proper operation of high coolant temperature shutdown on # 6 generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Sensor adjusted to proper temperature and tested satisfactory.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 18 May 2006 Resolved
Prove proper operation of high lube oil temperature alarm on # 5 generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Sensor adjusted and tested satisfactory.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 18 May 2006 Resolved
Prove proper operation of high lube oil temperature alarm on # 6 generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2006
Resolution: Sensor adjusted and tested satisfactory.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 3 November 2005 Resolved
Prove proper operation of # 1 generator high jacket water temperature alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Resolution: Readjusted sensor to within parameters.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 3 November 2005 Resolved
Prove proper operation of # 2 generator high jacket water temperature shut down.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Resolution: Readjusted shut down sensor to within allowable standards.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 November 2005 Resolved
Adjust # 1 FSD to close correctly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 15 February 2006
Resolution: Door adjusted to close correctly.
Lifesaving › Lifebuoys › Serviceable
Issued 3 November 2005 Resolved
Replace worn lifebuoy on first deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 3 November 2005
Resolution: Lifebuoy replaced during course of inspection.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 November 2005 Resolved
Adjust # 1 WTD to properly close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2005
Resolved 15 February 2006
Resolution: Door adjusted to close correctly.
Communications › Alarms/Indicators › Fire Alarm
Issued 10 August 2005 Resolved
Repair or replace and prove proper operation of fire pull station in pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Resolution: Pull station repaired during course inspection.
Fire Fighting › Fire Hoses › Condition
Issued 10 August 2005 Resolved
Replace leaking 2.5 inch hose # 35.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Resolution: Hose replaced with spare and ends cut off.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 10 August 2005 Resolved
Maintain engine room watch until uninterrupted power source for emergency generator has been built, installed and tested.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2005
Resolved 3 November 2005
Resolution: New UPS installed and tested satisfactory.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 May 2005 Resolved
Properly label all breakers in panel U-4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 13 May 2005
Resolution: Breakers labeled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 May 2005 Resolved
Remove duct tape and install proper blank in deck power panel in generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 13 May 2005
Resolution: Proper blank installed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 May 2005 Resolved
Adjust water tight door #1 to close within 30 seconds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 13 May 2005
Resolution: Water tight door adjusted.
Construction/Loadline › Hull › Bottom Plating
Issued 11 February 2005 Resolved
Provide copy of ABS survey report, to satisfy 2004 annual hull assessment survey.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2005
Resolved 15 February 2005
Resolution: Received notice that ABS completed their annual hull and machinery surveys on 15 SEP 04, credited annual internal structural examination for the Alternative Hull Examination program.
Lifesaving › Lifebuoys › Serviceable
Issued 10 November 2004 Resolved
Remove and replace lifebuoy on main deck starboard side forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 11 November 2004
Resolution: Lifebuoy replaced during course of inspection.
Operations/Management › Drills/Instruction › Fire
Issued 10 November 2004 Resolved
Provide training for all fire party personnel. During fire drill in music room on hold deck, first reponders were questioned on ways to extinguish fire, none knew of the fixed CO2 for the space or how to operate it.
Action required: 705 - Other - as specified
Due 11 November 2004
Resolved 11 November 2004
Resolution: Training was provided immediately after drill.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2004 Resolved
Properly mount wiring in music room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2004
Resolved 9 September 2004
Resolution: All wiring is properly mounted and unnecessary wiring removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2004 Resolved
Properly install wiring in port aft bar on first deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2004
Resolved 16 November 2004
Resolution: Wire replaced and installed properly.
Electrical › Electrical Distribution System (service)
Issued 2 December 2003 Resolved
MIS cabinet in housekeeping lockers need to have wiring properly routed. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 25 February 2004
Resolution: Cabinets properly wired.
Electrical › Electrical Distribution System (service)
Issued 2 December 2003 Resolved
MIS cables in bars, slot computer stands, ATM's, etc that have dead ended and hanging wires must be removed or properly installed. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 25 February 2004
Resolution: Dead end wires were removed.
Electrical › Electrical Distribution System (service)
Issued 2 December 2003 Resolved
UPS battery pack laying on wet deck needs to be raised and mounted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 25 February 2004
Resolution: Battery pack properly installed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 December 2003 Resolved
Repair/replace broken recepticle in slot tech office.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 2 December 2003
Resolution: Recepticle replaced.
Electrical › Electrical Distribution System (service)
Issued 2 December 2003 Resolved
Properly install wire run ROX blocks going through overhead in slot tech office. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 25 February 2004
Resolution: Bulkhead penetrations properly installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2003 Resolved
Properly install all wiring in surveillance room overhead, ie: use installed cable ways. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 9 September 2004
Resolution: Due to the amount of improper wiring extensive rewiring was completed, all wiring for surveillance has been properly mounted.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 December 2003 Resolved
Starboard remote pull on hold deck needs a bracket to hold in place. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 25 February 2004
Resolution: Bracket installed.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 2 December 2003 Resolved
Remove trash and clean under refrigerators and ice machine in deli prep room. LEGACY COMPONENT DESC: Recreation Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2003
Resolved 25 February 2004
Resolution: All areas cleaned.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 December 2003 Resolved
Install retroreflective tape on two lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 2 December 2003
Resolution: Reflective tape installed during course of inspection.
Electrical › Lighting (emergency)
Issued 15 August 2003 Resolved
Repair/replace emergency light in starboard midships stairwell and another emergency light in 4th deck forward stairwell. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 15 August 2003
Resolved 15 August 2003
Resolution: Replaced (2) emergency light bulbs
Lifesaving › Lifebuoys
Issued 15 August 2003 Resolved
Place reflective tape on ring bouy.
Condition: Improper/Lack of Maintenance
Due 22 August 2003
Resolved 8 September 2003
Resolution: Reflective tape installed.
Fire Fighting › Ventilation Systems › Helicopter Decks
Issued 15 August 2003 Resolved
Adjust fire dampner to completely close.
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 15 August 2003
Resolution: Fire dampner properly adjusted.
Electrical › Electrical Distribution System (service)
Issued 15 August 2003 Resolved
Afix wallplate to wall for phone line in 2nd deck port bar area.
Condition: Improper Installation
Due 15 August 2003
Resolved 15 August 2003
Resolution: Wallplate properly mounted.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 August 2003 Resolved
Make proper repairs to surveillance and computer room CO2 pull station cables. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 15 November 2003
Resolved 8 September 2003
Resolution: Repairs were made.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 August 2003 Resolved
Move CO2 manual operating instructions for emergency generator room into room by operating station.
Condition: Improper Installation
Due 15 October 2003
Resolved 8 September 2003
Resolution: Instructions moved to readable place if manual operation needed.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 August 2003 Resolved
Provide Coast Guard approved engine automation test procedures.
Due 15 September 2003
Resolved 8 September 2003
Resolution: USCG provided copy of approved test procedures.
Construction/Loadline
Issued 29 May 2001 Resolved
MAKE NECESSARY REPAIRS TO SLIDING WTD #4 TO SHOW PROPER MANUAL OPERATION USING THE LOCAL HAND PUMP.
Condition: Unknown
Due 29 May 2001
Resolved 29 May 2001
Lifesaving
Issued 23 May 2001 Resolved
VESSEL SHALL REMAIN DOCKSIDE UNTIL ALL REQUIRED IBAs ARE ON BOARD. VESSEL MAY OPERATE UNDERWAY WITH LESS THAN THE REQUIRED IBAs, PROVIDED THE TOTAL PERSONS ON BOARD IS REDUCED SO THAT THE CAPACITY OF THE IBAs ON BOARD IS ATLEAST 10% OF THE TOTAL PERSONS ON BOARD,
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Construction/Loadline
Issued 2 April 2001 Resolved
REPAIR POWER ACTUATOR FOR SLIDING WATERTIGHT DOOR #4. VESSEL MUST REMAIN DOCKSIDE UNTIL REPAIR HAS BEEN COMPLETED.
Condition: Unknown
Due 2 May 2001
Resolved 5 April 2001
Fire Fighting
Issued 30 October 2000 Resolved
RETEST THE SPRINKLER STORAGE TANK HIGH AND LOW LEVEL ALARMS TO PROVE PROPEROPERATION, MAINTAIN CHECK OF STORAGE TANK LEVEL AT 1 HOUR INTERVALS UNTIL SATISFACTORY TESTS HAVE BEEN COMPLETED.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 30 August 2000 Resolved
PROVIDE MEANS TO OBSERVE PROPER OPERATION OF THE FIRE DAMPER LOCATED IN THEWOMENS RESTROOM, BREAK ROOM.
Condition: Unknown
Due 30 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 30 August 2000 Resolved
COMPLETE THE REQUIRED ANNUAL SERVICING/TESTING OF THE SPRINKLER SYSTEM.
Condition: Unknown
Due 30 September 2000
Resolved 29 September 2000
Construction/Loadline
Issued 25 February 2000 Resolved
REPAIR OR REPLACE FRACTURED BILGE PUMP HOUSING AND PROPERLY ALIGN DISCHARGEPIPING TO ELIMINATE BUILT IN STRESSES ON THE CAST PUMP HOUSING. IF THE BILGE PUMP IS INCAPACITATED OR REMOVED, VESSEL IS RESTRICTED TO DOCKSIDE GAMING SESSIONS ONLY._x001C_
Condition: Unknown
Due 25 February 2000
Resolved 25 February 2000
Electrical
Issued 1 September 1999 Resolved
PROVE SATISFACTORY OPERATION OF THE BOW THRUSTER ROOM GENERAL ALARM BEACON.
Condition: Unknown
Due 1 October 1999
Resolved 30 October 1999
Fire Fighting
Issued 1 September 1999 Resolved
TEST SPRINKLER SYSTEM TANK HIGH AND LOW LEVEL ALARMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1999
Resolved 30 October 1999
Engineering
Issued 1 September 1999 Resolved
SUBMIT PERIODIC SAFETY TEST PROCEDURES FOR APPROVAL.
Condition: Unknown
Due 1 September 1999
Resolved 1 September 1999
Electrical
Issued 30 March 1999 Resolved
MAKE PERMANENT REPAIRS TO THE EMERGENCY GENERATOR AUTOMATIC TRANSFER BUS REQUIRED BY 46CFR112.25-10. UNTIL COMPLETED, PROCEDURES MUST BE ESTABLISHED TO ENSURE MANUAL BUS TRANSFER IS ACCOMPLISHED IN NO MORE THAN 45 SECONDS FROM LOSS OF SHIPS SERVICE POWER/NORMAL SOURCE.
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Fire Fighting
Issued 17 December 1998 Resolved
ADJUST OR REPAIR AIR HANDLERS #11 AND #12, PROVE PROPER OPERATION OF AUTOMATIC DAMPNER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1999
Resolved 24 September 1999
Fire Fighting
Issued 17 December 1998 Resolved
CLEAN AND ADJUST OR REPAIR AIR HANDLER #35, PROVE PROPER OPERATION OF AUTOMATIC DAMPNER.
Condition: Unknown
Due 5 January 1999
Resolved 24 September 1999
Fire Fighting
Issued 11 September 1998 Resolved
CONDUCT ANNUAL SERVICING ON THE FIXED CO2 FIRE EXTINGUISHING SYSTEM REMOTESTHAT ARE NITROGEN ACTIVATED.
Condition: Unknown
Due 30 September 1998
Resolved 27 August 1999
Electrical
Issued 11 September 1998 Resolved
OBTAIN TEST PROCEDURE AND PROVE PROPER OPERATION OF THE EMERGENCY GENERATOROVERSPEED TRIP AND OVERCRANK PROTECTION.
Condition: Unknown
Due 30 September 1998
Resolved 27 August 1999
Electrical
Issued 11 September 1998 Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY GENERATOR LOW L/O PSI TRIP AT12 PSI.
Condition: Unknown
Due 30 September 1998
Resolved 27 August 1999
Accommodation/Occupational Safety
Issued 11 September 1998 Resolved
REMOVE 3RD DECK BAR HOT DOG GRILL OUT FROM UNDER THE #30 AIR HANDLER.
Condition: Unknown
Due 30 September 1998
Resolved 27 August 1999
Fire Fighting
Issued 11 September 1998 Resolved
SHOW PROPER OPERATION OF THE #17 EXHAUST VENT, PROVE AUTOMATIC DAMPER CLOSES FULLY.
Condition: Unknown
Due 30 September 1998
Resolved 27 August 1999
Engineering
Issued 6 August 1998 Resolved
VESSEL SHALL NOT GET UNDERWAY FOR ANY CRUISES UNTIL PROPER REPAIRS TO, AND OPERATION OF, THE #1 AND #3 Z DRIVES HAVE BEEN PROVEN.
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Fire Fighting
Issued 17 December 1997 Resolved
Provide proper space separation in the forward hold office space area between the locker rooms, the corridor and the office spaces. Appropriate fire protection boundaries must be provided IAW Table 72.05-10(e) and (g).
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Engineering
Issued 17 December 1997 Resolved
Repair leaks to hydraulic system for forward bow thruster. Until repairs are effected, ensure minimal oil buildup with routine patrols and cleanup.
Condition: Unknown
Due 22 December 1997
Resolved 22 December 1997
Fire Fighting
Issued 17 December 1997 Resolved
Provide proper marking for sprinkler tank to indicate correct de-rated MAWP.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Accommodation/Occupational Safety
Issued 2 October 1997 Resolved
Install steel deck plates in the machinery spaces to allow for safe egress from the space and to provide an adequate firefighting platform. Steel plates must be included on either side of watertight doors and a base for all ladders. Submit proposed sketch and time frame for compliance.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Construction/Loadline
Issued 2 October 1997 Resolved
Remove metal splash guard from weather doors and provide adequate weather stripping after properly adjusting the doors. Demonstrate proper operationof doors.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Accommodation/Occupational Safety
Issued 2 October 1997 Resolved
Properly mount T-handles for opening the access and escape hatches from theengineroom, EOS, CO2 room, and bow thruster room.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
Provide a copy of the approved structural fire protection plans for the offices in the hold spaces to verify "Type" of spaces and appropriate typesof insulation.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Engineering
Issued 2 October 1997 Resolved
Perform design verification test of main propulsion automation in accordance with the MSC approved procedure after affecting modifications tothe Programmable Logic Controller for the Z-drives to alarm of a failure ofthe indicator that would show control of Z-drive was passed to the EOC.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
Lower the fire load in the cage and credit office and the accounting officeto a maximum of 3 pounds per square foot in accordance with MTN 6-95.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Engineering
Issued 2 October 1997 Resolved
Provide copy of U1A certificate for the sprinkler pressure tank showing thetank was designed to the corrosion allowances of 46CFR54.01-35.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Electrical
Issued 2 October 1997 Resolved
Provide additional emergency lighting per marked up general arrangement plans and demonstrate level of emergency lighting.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
Provide updated fire load calculations for all hold office spaces and any other spaces that have a fire load in excess of 2.5 pounds per square foot.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Navigation
Issued 2 October 1997 Resolved
Demonstrate that the M/V GAIL RHODES can safely maneuver the ARGOSY VI intothe shore facility per the contingency plan procedures.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Unknown
Issued 11 September 1997 Resolved
01. COMPLETE INITIAL CERTIFICATION WORKLIST DATED 11SEP97 TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997

Casualty record · 1

17 September 2020Routine · role: Involved in a Marine Casualty · activity 7082934
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.