Records from 1981 to 1996. Most recent: inspection, 11 August 1996.
Inspection history · 71
11 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088042
18 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182638
11 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377473
6 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 85857
6 March 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 858332
9 September 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 665388
8 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389895
29 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 516571
25 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 671564
21 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 33812
26 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 141312
22 July 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417531
10 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 499823
3 December 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 463786
3 March 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 826000
13 November 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254089
1 October 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464868
22 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 514850
7 September 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 448953
31 August 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935405
28 August 1991
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253556
16 April 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 439134
6 February 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911030
24 August 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 475092
23 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223392
18 May 1990
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1241879
5 March 1990
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901708
19 February 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928763
19 October 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 508968
19 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347253
30 May 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1193909
7 April 1989
Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197744
21 March 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 902258
13 March 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1209132
9 March 1989
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 889475
7 December 1988
MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1039828
7 December 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209984
25 November 1988
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 894544
7 October 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 326393
29 June 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033140
19 June 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1202528
19 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 463749
7 May 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347463
30 April 1988
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037215
24 March 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1302685
3 November 1987
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1328628
9 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310528
9 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336029
9 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292738
24 June 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 997373
14 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295227
12 June 1986
Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295599
4 June 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 440053
20 May 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 501825
5 March 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996000
3 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992268
8 January 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 504185
26 November 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995889
26 November 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002925
18 November 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301694
29 October 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1300413
27 June 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 530385
30 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 510553
17 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970683
5 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278346
30 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967529
14 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969882
28 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278044
16 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968691
29 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966752
26 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966623
Deck/Cargo
Issued 28 August 1991
Resolved
MAKE AVAILABLE FOR INSPECTION ALL PIPING FOR STEAM HEATING SYSTEM IN ALL CARGO TANKS.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Deck/Cargo
Issued 28 August 1991
Resolved
MAKE PERMANENT REPAIRS TO STEAM PIPING SYSTEM IN CARGO TANK NO. 2 PORT AS NECESSARY.
Condition: Unknown
Due 28 August 1991
Resolved 28 August 1991
Construction/Loadline
Issued 18 May 1990
Resolved
DETERMINE SOURCE OF OIL LEAK IN WAY OF NO.#3 AND/OR NO.#4 STARBOARD CARGO TANKS AND MAKE PERMANENT REPAIR TO THE SATISFACTION OF THE COGNIZANT [name withheld] MOBILE, AL THIS DATE WITHOUT CARGO AND PROCEED TO HOUMA,LA
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 30 May 1989
Resolved
OFFLOAD BARGE COMPLETELY AND LOAD NO CARGO UNTIL ALL CARGO TANKS HAVE BEEN PROVEN SOUND AND LEAK FREE.
Condition: Unknown
Due 30 May 1989
Resolved 30 May 1989
Deck/Cargo
Issued 21 March 1989
Resolved
COMPLETE OFFLOADING, UPON COMPLETION HAVE BARGE GAS-FREED BY QUALIFIED CHEMIST. ALSO HAVE THE ENTIRE SIDE SHELL & BOTTOM PLATING BELT GAUGED AT A REPAIR FACILITY.
Condition: Unknown
Due 21 March 1989
Resolved 21 March 1989
Deck/Cargo
Issued 21 March 1989
Resolved
HAVE CARGO PIPING HYDRO TESTED TO 1.5 MAX WORKINGPRESSURE. PROVIDE ALL REQUIRED GAUGING REPORTS TO THE USCG INSPECTOR.
Condition: Unknown
Due 21 March 1989
Resolved 21 March 1989
Deck/Cargo
Issued 9 March 1989
Resolved
REDUCE LEVEL OF CARGO IN TANK #5 STBD, 24" BELOW THE EXISTING FRACTURE IN THE SIDE SHELL PLATING THAT IS TEMPORARILY REPAIRED PRIOR TO DEPARTURE FROMARCO DK, TXCITY. PROCEED TO PHILLIPS DK IN FPT, TX TO OFFLOAD ALL CARGO ABOARD. DO NOT LOAD ANY CARGO ONCE DISCHARGED UNTIL PERMANANT REPAIRS OCCUR
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Construction/Loadline
Issued 25 November 1988
Resolved
LOCATE AND REPAIR LEAK IN CARGO TANK.
Condition: Unknown
Due 25 November 1988
Resolved 25 November 1988
Documentation
Issued 7 October 1988
Resolved
INSPECTORS COULD NOT FIND THE COI ONBOARD
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Construction/Loadline
Issued 7 October 1988
Resolved
HATCHES WERE NOT DOGGED. INSPECTORS WERE ABLE TO OPEN HATCHES BY HAND
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Deck/Cargo
Issued 7 October 1988
Resolved
HATCHES WERE LEFT OPEN WITHOUT FLAME SCREENS AND WITHOUT SUPERVISION
Condition: Unknown
Due 7 October 1988
Resolved 7 October 1988
Construction/Loadline
Issued 19 June 1988
Resolved
OFFLOAD ALL CARGO, GAS FREE, AND MAKE PERMANENT REPAIRS TO LEAK IN #4 STARBOARD CARGO TANK. DO NOT LOAD ANY CARGO UNTIL REPAIRS ARE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1988
Resolved 19 June 1988
Deck/Cargo
Issued 30 April 1988
Resolved
REMOVE ALL CARGO FROM #2 & 3 PORT CARGO TANK-DUE TO DAMAGE-PROCEED DIRECTLYTO HILL PETROLEUM TO OFFLOAD CARGO AND PROCEED DIRECTLY TO BOURG DRYDOCK, TO MAKE PERMANANT REPAIRS.
Condition: Unknown
Due 30 April 1988
Resolved 30 April 1988
Construction/Loadline
Issued 24 June 1986
Resolved
MAINTAIN TEMPORARY REPAIR TO FRACTURE APPROX 1 1/2" L X 1/8" W. LOCATED 12" FWD OF BULKHEAD IN #3 STRD CARGO TANK. PERMANENT REPAIRS TO BE EFFECTEDTO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO LOADING CARGO.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Deck/Cargo
Issued 12 June 1986
Resolved
GAS FREE AND MAKE PERMANENT REPAIRS TO THE 5" (FIVE) CRACK IN WAY OF THE #6PORT CARGO TANK PRIOR TO LOADING ANY CARGO AND IN NO CASE LATER THAN 19JUN86. REPAIRS TO BE MADE TO THE SATISFACTION OF THE COGNIZANT [name withheld] DATE IS 19JUN86.
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Deck/Cargo
Issued 3 March 1986
Resolved
VESSEL IS TO PROCEED TO BOURG DRYDOCKING AND REPAIR TO EFFECT NECESARY REPAIRS. VESSEL IS NOT TO ONLOAD CARGO PRIOR TO SATISFACTORY COMPLETION OF REPAIRS.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Deck/Cargo
Issued 3 March 1986
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY SHUTDOWN LINE/PULL MECHANISM
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Deck/Cargo
Issued 3 March 1986
Resolved
IN CONJUNCTION WITH PROVE-MENTIONED DISCREPANCY ITEMS, PROVIDE HYDRO TEST FOR CARGO PIPING AND VALVES IN THE PRESENCE OF AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Deck/Cargo
Issued 3 March 1986
Resolved
MAKE REPAIRS TO #7 CARGO TANK (S) COMPAAARTMENT VALVE.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Deck/Cargo
Issued 3 March 1986
Resolved
CHANGE OUT GASKET FOR BUTTERWORTH OPENING IN WAY OF #7 CARGO TANK (S) IN ADDITION, REPLACE MISSING BOLT IN SAME.
Condition: Unknown
Due 3 March 1986
Resolved 3 March 1986
Construction/Loadline
Issued 28 December 1982
Resolved
PROCEED TO BAYOU SALE, LA. TO OFFLOAD CARGO. PRIOR TO RELOADING BARGE HAVE DAMAGE CARGO TANK GAS-FREE AND MADE AVAILABLE TO USCG MIO INSP TO EXAM.
Condition: Unknown
Due 28 December 1982
Resolved 28 December 1982
Deck/Cargo
Issued 29 October 1982
Resolved
PRIOR TO LOADING CARGO TEST AFT CARGO TANKS TO DETERMINE LOCATION OF HOLE AND MAKE PERM. REPAIRS TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 29 October 1982
Resolved 29 October 1982