Records from 1997 to 2008. Most recent: inspection, 11 January 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
11 January 2008
Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3126430
15 November 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3100740
30 July 2007
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3013733
12 July 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2991965
23 March 2007
Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2894789
27 July 2006
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2724876
15 September 2004
Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2196268
30 July 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1861367
17 July 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1848450
27 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1803503
18 March 2003
Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1758702
18 March 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1759279
4 March 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1752786
4 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1739967
21 January 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1733714
9 December 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1716402
6 July 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 279531
6 June 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278637
22 December 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 435732
25 June 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 429928
15 June 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 429280
25 May 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428913
14 May 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 678133
10 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424416
4 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423367
16 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415944
12 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 411053
13 May 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 403678
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 July 2007
Resolved
VSL's EPIRB had an expired hydrostatic release.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 30 July 2007
Resolution: Agent provided adequate proof that a new hydrostatic release was installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 July 2007
Resolved
Door # 88, the portside galley door, has not been properly maintained and is not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 30 July 2007
Resolution: Agent provided adequate proof from class society that the deficiency has been rectified.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 12 July 2007
Resolved
VSL did not submit mandated Ballast Water report to NBIC.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2007
Resolved 14 July 2007
Resolution: Coast Guard Sector Guam received adequate BWM submission information from the agents.
Lifesaving › Inflatable Liferafts › Servicing
Issued 23 March 2007
Resolved
Liferafts to expire prior to US Port return. Provide proof of servicing or extention from flag in accordance with SOLAS regulations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2007
Resolution: Received certification from flag for the extension of liferaft servicing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 March 2007
Resolved
Fixed CO2 system to expire prior to return to U.S. Port. Provide proof of servicing in accordance with GL class rules and Administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2007
Resolution: Received certification from flag for extension to 29JUN07.
Construction/Loadline › Structures › Door
Issued 27 July 2006
Resolved
Engine room stack hatch door is unable to close.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2006
Construction/Loadline › Structures › Door
Issued 27 July 2006
Resolved
Fire doors do not close properly.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 21 September 2006
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 27 July 2006
Resolved
Holed deck in engine control room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 September 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 July 2006
Resolved
Decks in engine control room is wood. Replace with non-combustible material or provide documentation that decks have low flame spread characteristics adopted by IMO Resolution A.653(16).
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 20 September 2006
Resolution: Not required due to keel laid date.
Engineering
Issued 6 June 2000
Resolved
Make repairs to fuel vent on Stbd side.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Documentation
Issued 6 June 2000
Resolved
Provide warning statement on manuevering fact sheet.
Condition: Unknown
Due 6 June 2000
Resolved 6 June 2000
Documentation
Issued 6 June 2000
Resolved
Commence logging of Pre-arrival tests in accordance with ship's Safety Management System.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Navigation
Issued 15 June 1999
Resolved
VESSEL WAS ISSUED A LETTER OF DEVIATION TO ENTER PORT WITH AN INOPERATIVE GYRO COMPASS. LETTER OF DEVIATION REQUIRES SATISFACTORY REPAIR PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 25 May 1999
Resolved
Prior to 25JUN99, properly post instructions for rescue boat in davit area.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Prior to 25JUN99, make fire control plan reflect proper ship's name.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Prior to 25JUN99, provide fireproof lifeline for fireman's outfit.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 25 May 1999
Resolved
Prior to departure, provide engine for rescue boat.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 25 May 1999
Resolved
Immediately commence proper logging in garbage log IAW the log's instructions.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Lifesaving
Issued 25 May 1999
Resolved
Prior to 25JUN99, prove expiration date of EPIRB battery.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Navigation
Issued 4 December 1998
Resolved
PROVIDE TIDAL CURRENT TABLE IN ACCORDANCE WITH 33 CFR 164.33 (3) (ii).
Condition: Unknown
Due 10 January 1999
Resolved 10 January 1999
Engineering
Issued 4 December 1998
Resolved
PROVIDE TECHNICIANS REPORT ATTESTING TO SATISFACTORY TESTING OF MAIN DIESELENGINE.
Condition: Unknown
Due 6 December 1998
Resolved 7 December 1998
Engineering
Issued 4 December 1998
Resolved
PROVIDE CLASS SOCIETY SURVEY REPORT ATTESTING TO SATISFACTORY REPAIRS TO MAIN DIESEL ENGINE.
Condition: Unknown
Due 6 December 1998
Resolved 7 December 1998