SMARTY is a 1992 freight ship. The Coast Guard has recorded 75 inspections since 1997, most recently in June 2008, along with 220 deficiencies and 17 operational controls.
Records from 1997 to 2008. Most recent: inspection, 23 June 2008.
- Built
- 1992
- Last inspected
- 23 June 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 220 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9057185 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3MH7
457415
Flag
CYPRUS
—
Maury page id
psix-457415
Inspections, by type
…with no type recorded43
Years with a record
12 calendar years (1997–2008)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2598 - Convention (Subpart B), Gross Ton
4716 - Dead Weight, Ton
4716 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 75
23 June 2008
ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3239501
15 December 2007
Deficiency Check · ISPS III Exam · PI Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3116120
12 November 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3097052
9 November 2007
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3095966
6 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3094130
4 October 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3067277
4 October 2007
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PI Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3067365
7 July 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2986868
1 July 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2979127
27 June 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2975982
27 June 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2976040
2 June 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2949337
12 May 2007
ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2928927
10 May 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2931195
16 April 2007
NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2908679
12 April 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2906452
10 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2904896
13 March 2007
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2887212
2 February 2007
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2865882
29 January 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2863696
18 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2717104
1 July 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2697281
10 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2584065
19 January 2006
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2569276
14 January 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2566875
24 August 2005
ISPS III Exam · ILO-147 Exam · MARPOL Annex I Examination · STCW 95 Exam · Ballast Water Examination · Deficiency Check · MARPOL Annex V Examination · PI Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2478393
12 July 2005
ISPS II Exam · STCW 95 Exam · MARPOL Annex V Examination · Ballast Water Examination · PI Safety Exam · ILO-147 Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2423714
7 July 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2418230
8 June 2005
Ballast Water Examination · Loadline Exam · MARPOL Annex I Examination · ISPS I Exam · STCW 95 Exam · ISM Exam · MARPOL Annex V Examination · ILO-147 Exam · PI Safety Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2383431
6 January 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2269973
25 October 2004
STCW 95 Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · ILO-147 Exam · Loadline Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2227502
24 October 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2227438
24 October 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2250310
2 October 2004
ISPS I Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2211455
1 October 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2211454
10 July 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2128423
10 July 2004
ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2128496
18 March 2004
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2026655
5 March 2004
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2019022
16 December 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1964936
25 August 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1888542
23 August 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1884461
21 February 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1749231
29 January 2003
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1736839
25 January 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1735907
25 January 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1736801
13 October 2002
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1689113
24 September 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1679671
15 February 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1487039
18 January 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1478156
18 January 2002
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1479885
7 December 2001
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1473776
5 June 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 290679
27 April 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 289507
12 March 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 4755
12 March 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 287980
15 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278950
20 December 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 435553
25 August 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 431887
19 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 432138
30 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424134
27 June 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 417318
24 June 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 417003
13 May 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 415839
1 May 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 415383
30 March 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 414175
27 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 413521
19 January 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 411923
17 December 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 410989
9 November 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 409769
5 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 408569
22 July 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 406005
18 July 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 6209
25 June 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 405068
27 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404063
Deficiency record · 220
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 December 2007
Resolved
General sea water supply service piping has a large temporary patch coming from sea chest. Repair to satisfaction of attending classification surveyor.
Construction/Loadline › Structures › Deck Plating
Issued 15 December 2007
Resolved
Weather tightness of cargo hold #1 is compromised due to numerous holes in cargo hatch. Observed 06 holes with red hand and rubber patches that were painted over, stopped further evaluation. The inability to secure against weather and sea conditions presents a substantial safety risk for crew and vessel. Temp Repair completed.
Construction/Loadline › Structures › Deck Plating
Issued 15 December 2007
Resolved
Weather tightness of cargo hold #2 is compromised due to numerous holes in cargo hatch. Observed 06 holes with red hand and rubber patches that were painted over, stopped further evaluation. The inability to secure against weather and sea conditions presents a substantial safety risk for crew and vessel. Temp Repair completed.
Construction/Loadline › Structures › Deck Plating
Issued 15 December 2007
Resolved
PSCO’s found numerous deterioration holes in main deck plating on fantail, above steering gear. 08 Holes have been filled with rubber and painted over. Leaks were identified in steering gear room. Temp Repair completed.
Construction/Loadline › Structures › Deck Plating
Issued 15 December 2007
Resolved
PSCO's found numerous deterioration holes in main deck plating aft section of number 2 cargo hold. Deck plating shows signs of excessive weathering. Temp Repair completed.
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 15 December 2007
Resolved
Rescue boat has several patches and or plugs that are not maintaining air tight integrity. Crew members have made several attempts to correct the issued with negative results. Rescue boat was found partially deflated.
Accommodation/Occupational Safety › Potable Water System › General
Issued 15 December 2007
Resolved
Vessel Master stated that the ship took on bad water 7 days ago and that the crew must boil all water prior to human consumption. Repair to satisfaction of Flag Administration.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 15 December 2007
Resolved
Vessel's cook had informed PSCO's that there was only enough provisions on board for one more meal. Ship's agent informed that provisions cannot be delivered for 02 days. Vessels cargo operations were stopped by the Coast Guard until provisions confirmed for same day delivery.
Stability › Unintentional Flooding › General
Issued 15 December 2007
Resolved
Standing on the main deck, looking into #1 cargo hold, PSCO's observed ballast water leaking from #1 ballast tank into #1 cargo hold. Master stated that there are additional holes but inspectors can not go into hold until it is opened and cleaned of cargo product. Vessel is to have all ballast tanks filled to capacity and cargo hold inspected by class surveyor prior to loading cargo. Temp Repairs
Stability › Unintentional Flooding › General
Issued 15 December 2007
Resolved
PSCO's discovered 2 holes in #2 cargo hold. #3 & #4 Port and Starboard ballast tanks were partially filled and exam revealed two holes leaking water from # 3 ballast tank into cargo hold. Vessel is to have all ballast tanks filled to capacity and cargo hold inspected by attending class surveyor [name withheld] completed.
Stability › Unintentional Flooding › General
Issued 15 December 2007
Resolved
During expanded exam of hull structures and cargo tanks, PSCO's discovered wastage holes on Forward peak tank top plating/Bosun hole deck plating. Master stated that the water tank floods Bosun hole during heavy weather. Temp Repair completed.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 15 December 2007
Resolved
Gyro is overheating during regular operations. Crew installed temporary cooling ventilation duct work. Temp Repair completed.
Lifesaving › Launching Appliances › Davit
Issued 15 December 2007
Resolved
Once vessel completes necessary repairs to rescue boat hull defects, class surveyor to inspect and test launching arrangements of rescue boat and davit examination.
Operations/Management › Drills/Instruction › Fire
Issued 15 December 2007
Resolved
Vessel to complete satisfactory Fire and abandon ship drills prior to departure.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 15 December 2007
Resolved
Vessel cargo hatch hydraulic system is inoperable and is leaking fluid in multiple locations. Vessel is unable to open/close cargo hatches due to system failure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 October 2007
Resolved
Oily water separator's three-way "Leslie" valve is currently inoperable. Valve fails to make any action when 15 PPM alarm sounds. Marpol 73/78 (2006 Consolidated Ed.) Annex I/14
Documentation › Certificates/Documents › IOPP Certificate
Issued 4 October 2007
Resolved
The oily water separator on board has not been approved by the administration. IOPP indicates that system is equipped with an automatic stopping device, when the current system on board has a three-way valve. Marpol 73/78 (2006 Consolidated Ed.) Annex I/14.1
Engineering › Diesel Engine (auxiliary) › Valve
Issued 4 October 2007
Resolved
Main fuel pipe to emergency fire pump is leaking fuel at coupling up stream of isolation valve, due to excessive vibration, caused by fuel piping not being properly secured. This condition creates a dangerous fire hazard.
Fire Fighting › Means of Escape › Doorways
Issued 4 October 2007
Resolved
Door to escape trunk from lower level in engine room does not self-close when opened.
Fire Fighting › Nozzles › Condition
Issued 4 October 2007
Resolved
Fire hose nozzle in starboard side bridge wing box is leaking excessively due to the tip of the nozzle being cracked. There are no spares currently on board. Solas 74 (1983 Amendments) II-2/21
Personnel › Training › Search and Rescue
Issued 4 October 2007
Resolved
Unsafe conditions observed with personnel launching/recovering rescue boat. Rescue boat recovered without aft frap line, potentially losing rescue boat equipment. STCW 78/95 (2005 Ed.) A-VI/2
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 1 July 2007
Resolved
The #2 generator starboard side was found in operable due to a fault in th automatic voltage regulator.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 June 2007
Resolved
Both Class "A" fire doors in stairway leading to corridors on both the main deck and poop deck do not self-close when released. Repair to satisfaction of attending class surveyor.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 13 May 2007
Resolved
The mechanical seal on the #1 fire pump located in the engine room is worn and spraying water approximately two to three feet. Repair or replace to the satisfaction of attending classification society surveyor.
Engineering › Steam Boiler (auxiliary/waste heat) › Pump
Issued 13 May 2007
Resolved
The #2 feed water pump for the ship service donkey boiler is inoperable. Vessel is required to have two operational. Repair or replace to the satisfaction of attending classification society surveyor.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 13 May 2007
Resolved
The vessel's rescue boat motor is inoperable. Repair or replace to the satisfaction of attending classification society surveyor.
Fire Fighting › Means of Escape › Doorways
Issued 13 May 2007
Resolved
The means of escape from the vessel's engine room forward of the ship service generator's self closing mechanism is inoperable, and is restricted by the piping located above. A second means of escape door's self closing device is also inoperable directly above on the next level. Repair or replace to the satisfaction of attending classification society surveyor.
Fire Fighting › Fire Pumps › Arrangement
Issued 13 May 2007
Resolved
The vessel's #3 fire pump located in the engine room has not been approved by classification society and is therefore not in compliance with the vessel's fire control plan. Request attending classification society surveyor to verify.
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 May 2007
Resolved
The fuel shut off valve for the ship service generator is inoperable. Repair of replace to the satisfaction of attending classification society surveyor.
Fire Fighting › International Shore Connection › Connection
Issued 13 May 2007
Resolved
The vessel's international shore connection was not readily available. All items were present, however the bolts were severely corroded and could not be removed. No wrenches were available to assist in removing the connection. Maintenance must be completed and repairs attested to by attending classification society surveyor.
Fire Fighting › Fire Hydrants › Condition
Issued 13 May 2007
Resolved
The vessel's fire station located midship inside accommodation on the poop deck's gasket is wasted and leaking in between the valve and the fire main pipe connection.
Fire Fighting › Fire Hydrants › Condition
Issued 13 May 2007
Resolved
Both fire station's located on the port side second deck of the engine room fire hose gaskets are missing. The gaskets of both fire hose's inside the fire stations located on the port and starboard side of the boat deck are dry rotted. The gaskets of the fire hose inside the fire station located on the starboard side of the poop deck are also rotted. Replace to the satisfaction of class
Operations/Management › Drills/Instruction › Abandon Ship
Issued 13 May 2007
Resolved
The vessel's crew was not familiar with their assigned duties for abandon ship drill. Crew members did not provide life saving items in accordance with emergency muster list.
Operations/Management › Drills/Instruction › Fire
Issued 13 May 2007
Resolved
The vessel's crew was not familiar with their assigned duties for fire drill. Crew members did not don fireman's outfit properly. Second fireman's self contained breathing apparatus expired within five minutes of donning.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 May 2007
Resolved
The vessel's bulkhead located on poop deck in passageway in between the vessel's reefers and steering gear room is holed approximately 8 inches by 4 inches. Repair to the satisfaction of attending classification society surveyor.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 May 2007
Resolved
Vessel's potable water tank fill pipe and vent pipe are corroded and leaking water on poop deck in passageway in between vessel's reefer and steering gear room. There is approximately 4 inches of standing water on deck. Repair to the satisfaction of attending classification society surveyor.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 May 2007
Resolved
Evidence suggest that the required maintenance of life saving and fire protection systems were not carried out and recorded appropriately in accordance with Safety Management System procedures. Therefore, the vessel shall have an external audit conducted prior to departure.
Navigation › Piloting/Steering › Gyro Compass
Issued 16 April 2007
Resolved
Pilot reported inoperable gyro compass. Tech reported hole on inside surface just below contact screw for battery element.
Navigation › Piloting/Steering › Gyro Compass
Issued 31 January 2007
Resolved
While transiting outbound Brunswick Georgia, pilot noted failure in Gyro Compass and was forced to nav on magnetic compass heading. Deficiency to be corrected prior to next US port to the satisfaction of class.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 January 2007
Resolved
While transiting outbound Brunswick Georgia, pilot noted failure in Gyro Compass and was forced to navigate on magnetic compass heading. Magnetic compass also failed to swing to proper heading while turning on outbound course. Deficiency to be corrected prior to next US port to the satisfaction of class.
Navigation › Piloting/Steering › Gyro Compass
Issued 29 January 2007
Resolved
Vessel reports gyro is operating intermitently.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 July 2006
Resolved
Vessel's Fire Control Plan failed to clearly differentiate between Class "A" and Class "B" divisions. Vesel must provide proof of revisions made to plan to the satisfaction of Classification Society.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 19 January 2006
Resolved
Sink in hospital space inoperable.
Engineering › Fuel Oil Service System › Piping
Issued 12 July 2005
Resolved
Emergency fire pump fuel line was found leaking fuel.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 12 July 2005
Resolved
Stbd side F/O and sludge tank vent heads holed. diesel vent had hole in flame screen.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 July 2005
Resolved
Galley ventilation hatch on aft deck was found wasted.
Engineering › Fuel Oil Service System › Flange
Issued 12 July 2005
Resolved
HFO manifold on E/R lower level port side aft had 7 valves and 2 connections leaking.
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 12 July 2005
Resolved
#2 generator water pump had faulty seal.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 June 2005
Resolved
Master is missing Cyprus endorsement. Vessel is not manned in accordance with Minimum Safe Manning Certificate. Vessel is detained until requirements are met to the satisfaction of the Administration.
Engineering › Steering Gear System › Pump
Issued 7 June 2005
Resolved
STBD side steering gear pump is inoperable from bridge and emergency steering flat. Vessel is detained until a class report is received and reviewed by MSU Savannah
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 7 June 2005
Resolved
STBD side main generator has a fuel oil leak from high pressure fuel pump manifold. F/O is leaking 2-3 drips per seconds. Vessel is detained until leak is fixed to the satisfaction of class.
Construction/Loadline › Structures › Door
Issued 7 June 2005
Resolved
Class "B" door is missing at laundry room. All class "B" doors have holes where prior locks have been removed. Class "B" doors must be fixed prior to departure from port.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 7 June 2005
Resolved
Oil discharging placard is missing.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 June 2005
Resolved
Refrigeration compressor room is missing light covers (globes). Deficiency must be fixed to the satisfaction of class.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 June 2005
Resolved
Refrigeration freon compressor belt drive guard is missing. Deficiency must be fixed to the satisfaction of class.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 7 June 2005
Resolved
Echo depth sounder is inoperable. Provide class report attesting to proper operation.
Documentation › Certificates/Documents › IOPP Certificate
Issued 7 June 2005
Resolved
Max through-put for OWS does not match in oil record book and IOPP. IOPP lists max through-put as 1 cubic meter per hour and oil record book lists 2.5 cubic meters per hour. Deficiency must be fixed prior to departure from port.
Documentation › Logs/Records › Oil Record Book
Issued 7 June 2005
Resolved
Vessel does not have the past three years of oil record books on board. Deficiency must be fixed prior to departure from port.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 7 June 2005
Resolved
Several crew members rooms were found in unsatisfactory condition. Rooms were missing lights and appliances. Electrical wires were found exposed and hanging from sockets. Deficiencies must be fixed prior to departure from port.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 7 June 2005
Resolved
Due to various deficiencies found with lifesaving, machinery, navigation, fire structure, and crew documentation, There is clear grounds to suggest that the vessels ship safety management system is not working as required. It is required that the vessel have an ISM audit conducted prior to departure to the satisfaction of class.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 June 2005
Resolved
All lifejackets onboard are dry rotted. Vessel is detained until fixed to the satisfaction of class.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 25 October 2004
Resolved
The vessel is denied entry into all U. S. ports until adequate proof of compliance with the ISM code is provided to the cognizant COTP/OCMI. Vessel has 4 major nonconformities and 7 minor nonconformities still outstanding that must be cleared.
Electrical › Electric Generation Source (emergency) › Overcurrent Device
Issued 24 October 2004
Resolved
Emergency generator cycles gauge is inoperable.
Electrical › Electric Generation Source (service) › Generator
Issued 24 October 2004
Resolved
#2 ship service generator has cooling water leak.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 24 October 2004
Resolved
Hydraulic leaks on cargo hatch rams and associated controls and piping
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2004
Resolved
Stbd side of vessel aft below port hole windows has damage to hull.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 October 2004
Resolved
Fuel oil leak on emergency fire pump.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 October 2004
Resolved
Cooling water leak on emergency fire pump.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 October 2004
Resolved
#1 fire pump in engine room, discharge gauge inoperable.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 October 2004
Resolved
#2 fire pump in engine room smoking and sparking.
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 October 2004
Resolved
Port and stbd steering gear pumps have numerous leaks.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 October 2004
Resolved
Hydraulic leak on stbd side gangway control station.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 October 2004
Resolved
Vessel only has two of three required GMDSS radios that work.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 24 October 2004
Resolved
Vessel not manned in accordance with minimum safe manning document. 2nd engineer does not have Cyprus license on board.
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 October 2004
Resolved
Accommodation shower water overboard piping wasted.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 October 2004
Resolved
Sewage pipe parallel to fuel oil settling tanks has numerous holes and leaks.
Engineering › Lubricating Oil Service System › Cooler
Issued 24 October 2004
Resolved
Shaft L/O cooler inlet and outlet pipe is holed and leaking.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 October 2004
Resolved
Vessel S/W cooling overboard bypass holed and leaking.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 October 2004
Resolved
Main engine L/O cooling S/W pipe on engine room lower deck holed and leaking.
Engineering › Sea-water System (primary cooling) › Pump
Issued 24 October 2004
Resolved
Packing for both main engine sea water pumps need to be replaced.
Engineering › Fuel Oil Service System › Piping
Issued 24 October 2004
Resolved
Replace oil soaked insulation in way of heavy fuel oil manifold for fuel oil purifiers.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 24 October 2004
Resolved
Reinstall heat detector above inoperable fuel oil purifier.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 October 2004
Resolved
Remove oil soaked insulation for HFO heater manifold for main engine.
Engineering › Steam System (main) › Piping
Issued 24 October 2004
Resolved
S/W piping for steam condenser holed and leaking.
Engineering › Bilge Water Management System › Pump
Issued 24 October 2004
Resolved
Ballast pump outlet pipe holed with temp patch.
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 24 October 2004
Resolved
Vessel missing oil prohibiting discharge placard.
Fire Fighting › Means of Escape › Doorways
Issued 24 October 2004
Resolved
Fire door for emergency exit in engine room lower level is wasted and does not close.
Fire Fighting › Means of Escape › Doorways
Issued 24 October 2004
Resolved
Fire door for emergency exit in engine room second level does not close.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 24 October 2004
Resolved
A/C cooling overboard piping holed and leaking by engine room control room door.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 24 October 2004
Resolved
Main engine had a propulsion causality and loss power. Class to address cause of casualty prior to vessel departure.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 24 October 2004
Resolved
Vessel required to have a full external ISM audit conduct prior to departure to address maintenance deficiencies found during inspection
Pollution Prevention/Response › Prevention Equipment
Issued 5 March 2004
Resolved
Blank off sewage overboard valve and make repairs to the valve. Valve was locked in the open position. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Fire Fighting › Emergency Fire Pumps
Issued 21 February 2003
Resolved
EMERGENCY PULL FOR EMERGENCY FIRE PUMP FUEL TANK VALVE WAS BROKEN. LEGACY COMPONENT DESC: Arrangement
Navigation › Piloting/Steering
Issued 21 February 2003
Resolved
NUMEROUS LEAKS ON STEERING GEAR PUMPS 1 & 2.
Fire Fighting › Emergency Fire Pumps
Issued 21 February 2003
Resolved
VALVES ON EMERGENCY FIRE PUMP FUEL TANK LEAKING. LEGACY COMPONENT DESC: Arrangement
Fire Fighting › Emergency Fire Pumps
Issued 21 February 2003
Resolved
NUMEROUS OIL LEAKS ON EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: Arrangement
Fire Fighting › Emergency Fire Pumps
Issued 21 February 2003
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: Pressure
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 February 2003
Resolved
MISSING MACHINERY GUARDS FOR BOTH GENERATORS
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 February 2003
Resolved
F/O, L/O, AND COOLING WATER LEAKS ON MAIN ENGINE. LEGACY COMPONENT DESC: Cylinder Head
Engineering › Freshwater System (air cooling)
Issued 21 February 2003
Resolved
A/C COOLER S/W INLET PIPE HOLED AND LEAKING. LEGACY COMPONENT DESC: Piping
Accommodation/Occupational Safety › Potable Water System
Issued 21 February 2003
Resolved
F/W GENERATOR S/W PIPE FORWARD OF S/W PUMP HOLE AND LEAKING.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 February 2003
Resolved
REPLACE PACKING GLANDS IN WAY OF VALVES FOR HFO SEPARATOR, M/E L/O FILTER, AND HFO SERVICE TANK. LEGACY COMPONENT DESC: Valve
Engineering › Lubricating Oil Service System
Issued 21 February 2003
Resolved
#2 L/O COOLER IS LEAKING LUBE OIL. LEGACY COMPONENT DESC: Cooler
Electrical › Electric Generation Source (emergency)
Issued 21 February 2003
Resolved
D/O RETURN LINE ON EMERGENCY GENERATOR IS MADE OF HARD PLASTIC NOT METAL.
Deck/Cargo › Cargo Stowage
Issued 24 September 2002
Resolved
MAKE PERMANENT REPAIRS TO CARGO #2 COMPARTMENT'S CARGO HOLD HATCH HYDRAULIC RAM.
SOLAS 74(A) CH. 1 REG. 11 LEGACY COMPONENT DESC: HATCH HYDRAULIC RAM MOUNT
Engineering › Fuel Oil Service System
Issued 24 September 2002
Resolved
FIX SMALL FUEL LEAK ON THE MAIN DEISEL ENGINE #3 FUEL PUMP.
SOLAS 74(A) 11-2/15-2 LEGACY COMPONENT DESC: Pump
Navigation › Piloting/Steering
Issued 24 September 2002
Resolved
MAKE REPAIRS TO THE SMALL HYDRAULIC LEAKS ON STEERING GEAR PUMPS.
SOLAS 74(A) CH. 1 REG. 11 LEGACY COMPONENT DESC: STEERING GEAR PUMPS
Engineering › Diesel Engine (propulsion-direct drive)
Issued 24 September 2002
Resolved
REMOVE ALL OF THE OIL SOAKED INSULATION FOUND ON THE PIPES THAT ARE AFT OF THE MAIN DEISEL ENGINES.
SOLAS 74 (A) CH. 2 -2/1 LEGACY COMPONENT DESC: Piping (exhaust)
Accommodation/Occupational Safety › Occupational Safety
Issued 24 September 2002
Resolved
REPAIR/REPLACE THE BROKEN WELDS, HOLES AND WEAK HANDRAILS ON THE DECK AND ALL WORN POST AND RAILS.
ILLC 66 ANNEX 1/15 LEGACY COMPONENT DESC: Deck Rail
Electrical › Lighting (service)
Issued 7 December 2001
Resolved
IN THE #2 WHEELMANS CABIN A RADIO HAS BEEN SPLICED INTO SHIPS EXISTING WIRING. LEGACY COMPONENT DESC: Outlet Box
Fire Fighting › Structural - A Class Divisions
Issued 7 December 2001
Resolved
FIRE DOORS FOR SHIPS STAIR TOWER NUMBERS 27, 42, AND 57 NEED TO BE ADJUSTED FOR SELF CLOSURE. NUMBER 54 AND THE DOOR TO STAIRCASE ON BOATDECK LEVEL ARE MISSING SELF CLOSURE DIVICE. LEGACY COMPONENT DESC: Openings - Fire Doors
Accommodation/Occupational Safety › Cooking Systems
Issued 7 December 2001
Resolved
RANGE HOOD IN GALLEY NEEDS TO BE CLEANED OF EXCES GREASE.
Fire Fighting › Structural - A Class Divisions
Issued 7 December 2001
Resolved
FIRE DOORS FROM ENGINE ROOM EMERGENCY ESCAPE TRUNK ARE MISSING SELF CLOSURE DEVICES AND WILL NOT LATCH PROPERLY. LEGACY COMPONENT DESC: Openings - Fire Doors
Electrical › Electrical Distribution System (service)
Issued 7 December 2001
Resolved
TERMINATE OBSOLETE BATTERY CABLES ON EMERGENCY FIRE PUMP IN JUNCTION BOX OR REMOVE COMPLETELY. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 7 December 2001
Resolved
Repair cage door to back of main switchboard, missing mesh screen and does not properly close. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Pollution Prevention/Response › Prevention Equipment
Issued 7 December 2001
Resolved
Remove wooden plugs from oil containment boxes and replace with mechanical plugs. LEGACY COMPONENT DESC: Fixed Containment
Construction/Loadline › Structures
Issued 7 December 2001
Resolved
Repair bosun store, on aft deck, watetight door. Door is holed and gasket is wasted. LEGACY COMPONENT DESC: Door
Accommodation/Occupational Safety › Ventilation
Issued 7 December 2001
Resolved
Repair wasted fuel oil vent pipe heads, screens and screen guards wasted.
Deck/Cargo › Holds/Tanks
Issued 7 December 2001
Resolved
Repair wasted hydraulic hose on #1 hold starboard forward ram.
Deck/Cargo › Holds/Tanks
Issued 7 December 2001
Resolved
Provide class report on hatch cover rams mounting structure. Several fractures observed, several past repairs. LEGACY COMPONENT DESC: Hatch Cover
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 December 2001
Resolved
Replace fire extinguisher in emergency fire pump space to match fire plan and provide proper mounting bracket. LEGACY COMPONENT DESC: Location
Construction/Loadline › Structures
Issued 7 December 2001
Resolved
Repair watertight door to emergency generator room, it will not latch. LEGACY COMPONENT DESC: Door
Construction/Loadline › Structures
Issued 7 December 2001
Resolved
Repair watertight door to chiller room, rescue boat deck. Door is wasted and holed. LEGACY COMPONENT DESC: Door
Deck/Cargo
Issued 5 June 2001
Resolved
DECK CARGO HATCH HYDRAULIC RAMS ARE LEAKING ON DECK. CAUSING SLIP HAZARDS AND POSSIBLE POLLUTION CASES. MASTER STATES THAT REPAIRS CANNOT BE PERFORMED UNTIL NEXT DRY DOCK PERIOD.
Navigation
Issued 5 June 2001
Resolved
VESSELS SECONDARY RADAR INOPERATING PROPERLY. VESSEL HAS SCHEDULED TECH. REP. FOR NEXT PORT OF CALL SAVMS. MAIN RADAR IS STILL OPERATIONAL.
Documentation
Issued 20 December 1999
Resolved
SAFETY EQUIPMENT CERTIFICATE EXPIRED. HAVE CLASS ATTEND VESSEL AND CORRECT.
Fire Fighting
Issued 20 December 1999
Resolved
STARTER FOR EMERGENCY FIRE PUMP STARTED TO SMOKE WHEN STARTED. NO OTHER MEANS TO START FIRE PUMP. HAVE CLASS ATTEND AND VERIFY PROPER OPERATION OFSTARTER FOR EMERGENCY FIRE PUMP.
Documentation
Issued 20 December 1999
Resolved
IOPP CERTIFICATE INCOMPLETE. MISSING OWS THROUGH PUT. HAVE CLASS ATTEND VESSEL AND CORRECT.
Fire Fighting
Issued 30 December 1998
Resolved
Reattach or repair the closure devices on the ship's fire doors (machinery space & accommodations). SOLAS 74 amd II-2/45
Construction/Loadline
Issued 30 December 1998
Resolved
Repair the vent closures to the machinery space to allow them to close in event of CO2 release. ICLL 66 II/18
Engineering
Issued 30 December 1998
Resolved
Repair the jacket water leak on the aft of the main engine. SOLAS 74 amd II-1/26
Engineering
Issued 30 December 1998
Resolved
Replace the worn & leaking fuel lines on the generator engines. SOLAS 74 amd II-1/26
Lifesaving
Issued 30 December 1998
Resolved
Overhaul the ship's lifeboat and provide a class report on final repairs. SOLAS74 amd III/1
Engineering
Issued 30 December 1998
Resolved
Repair the fuel oil leaks on the tank in the emergency generator space. SOLAS 74 amd II-1/26
Engineering
Issued 30 December 1998
Resolved
Replace the wasted cover on the aft end of the MDE L/O heat exchanger. SOLAS 74 amd II-1/26
Engineering
Issued 30 December 1998
Resolved
Install containment boxes about the fuel & lube oil vents about the main deck. 33 CFR 155.320
Documentation
Issued 27 June 1998
Resolved
PROVIDE COPIES OF ALL DOCUMENTS WITH APPROPRIATE NAME CHANGE TO M/V DAISY.
Lifesaving
Issued 24 June 1998
Resolved
Provide a dynamic test for the stbd life boat due to a crack in the cradle,and provide a class report to USCG.
Lifesaving
Issued 24 June 1998
Resolved
Provide a static test for the stbd life boat due to crack in cradle, and provide a Class report to USCG.
Lifesaving
Issued 24 June 1998
Resolved
Repair crack in cradle where aft stantion meets davit arm when resting in the cradle. Crack is on aft cradle arm near where vessel uses wood to holdlifeboat into cradle. Repairs must be conducted to the satisfaction of theclass society surveyor.
Fire Fighting
Issued 24 June 1998
Resolved
Repair soft patch with new pipe on the saltwater cooling line in the engineroom.
Navigation
Issued 24 June 1998
Resolved
Provide a copy of the U.S. Inland Navigation Rules on board vessel.
Electrical
Issued 24 June 1998
Resolved
Remove dead ended wires aft on main deck port side under ladder to 01 deck.
Electrical
Issued 19 January 1998
Resolved
Close and secure battery box in steering gear room so that gases vent to exterior.
Engineering
Issued 19 January 1998
Resolved
Install vent pipe for diesel oil tank in steering gear room so that tank vents to exterior.
Electrical
Issued 17 December 1997
Resolved
Repair electrical junction box located aft of laundry room.
Unknown
Issued 17 December 1997
Resolved
Provide food and water on board vessel.
Electrical
Issued 17 December 1997
Resolved
Repar electrical receptacle located in (deck electrical compt).
Electrical
Issued 17 December 1997
Resolved
Repair light fixture overhead electrical shop.
Electrical
Issued 17 December 1997
Resolved
Replace cover over 8X10 junction box located in focsle stowage compt.
Lifesaving
Issued 17 December 1997
Resolved
Remove standing water from focsle stowage compt.
Electrical
Issued 17 December 1997
Resolved
Repair light fixtures in fire station compt #1.
Construction/Loadline
Issued 17 December 1997
Resolved
Repair water tight door for CO2 room.
Electrical
Issued 17 December 1997
Resolved
Repair light fixtures located in CO 2 room.
Electrical
Issued 17 December 1997
Resolved
Replace junction box cover located in mast house pump room.
Lifesaving
Issued 17 December 1997
Resolved
Remove hydraulic oil from deck in mast house pump room.
Construction/Loadline
Issued 17 December 1997
Resolved
Repair vent cover on #2 ballast vent housing.
Lifesaving
Issued 17 December 1997
Resolved
Repair lifeboat deckplates
Lifesaving
Issued 17 December 1997
Resolved
Provide eeeemergency lighting for lifeboat.
Lifesaving
Issued 17 December 1997
Resolved
Provide portable light for signaling in lifeboat.
Accommodation/Occupational Safety
Issued 17 December 1997
Resolved
Repair cooler & freezer for stowage of provisions.
Accommodation/Occupational Safety
Issued 17 December 1997
Resolved
Provide safe for consumption potable water.
Fire Fighting
Issued 17 December 1997
Resolved
Provide repairs and serviceing to all fire extinguishing appliances on_x001C_ board vessel as per Class.
Documentation
Issued 17 December 1997
Resolved
Ensure transfer operations are conducted using available oil transfer procedures.
Lifesaving
Issued 17 December 1997
Resolved
Provide a quick release installation for both bridge wing ring buoys.
Construction/Loadline
Issued 17 December 1997
Resolved
Make repairs to ventilation closures for engine room ventilation 02 deck.
Documentation
Issued 17 December 1997
Resolved
Provide a licensed 2nd engineer to meet the manning requirments.
Accommodation/Occupational Safety
Issued 17 December 1997
Resolved
Provide sanitary facilities for crew.
Fire Fighting
Issued 17 December 1997
Resolved
Provide fire retardent casing or similar for the motorlife boat engine as required by Solas III Reg 6.9
Construction/Loadline
Issued 17 December 1997
Resolved
Repair focsle hatch cover to make water tight.
Fire Fighting
Issued 17 December 1997
Resolved
Remove paint and combustibles from stowage locker, aft of galley and place in the paint locker.
Construction/Loadline
Issued 17 December 1997
Resolved
Repair gasket on aft stowage compartment on the 01 deck.
Construction/Loadline
Issued 17 December 1997
Resolved
Repair water tight emergency exit for the engine room.
Deck/Cargo
Issued 17 December 1997
Resolved
Provide a machinery guard on the reefer compressor.
Deck/Cargo
Issued 17 December 1997
Resolved
Provide a machinery guard for the A/C unit compressor.
Electrical
Issued 17 December 1997
Resolved
Repair light fixture in the electrical shop.
Construction/Loadline
Issued 17 December 1997
Resolved
Repair defective lifeboat embarcation step.
Lifesaving
Issued 17 December 1997
Resolved
Provide replacement fire extinguisher for lifeboat.
Navigation
Issued 17 December 1997
Resolved
Provide copy of Inland Navigation Rules.
Navigation
Issued 17 December 1997
Resolved
Provide copy of updated Tides and Current Table.
Lifesaving
Issued 17 December 1997
Resolved
Repair all fire boundry door latches.
Electrical
Issued 17 December 1997
Resolved
Provide proper wiring and mounting for the washing and dryer machines, remove all shock hazards.
Accommodation/Occupational Safety
Issued 9 November 1997
Resolved
Repair the following on the cooler/freezer: refrigeration unit. latches. door hinges.
Lifesaving
Issued 9 November 1997
Resolved
Repair all dead covers for port holes on lower deck.
Electrical
Issued 9 November 1997
Resolved
Provide protective cover for all lights on lower deck.
Lifesaving
Issued 9 November 1997
Resolved
Make effective repairs to aft door on lifeboat.
Documentation
Issued 9 November 1997
Resolved
Provide amended IOPP survey form to reflect 15ppm OWS.
Documentation
Issued 9 November 1997
Resolved
Provide valid safety equipment cert.
Navigation
Issued 9 November 1997
Resolved
Prove proper operation of power failure alarm for steering system on bridge.
Lifesaving
Issued 5 October 1997
Resolved
UPDATE MUSTER LISTS TO SHOW CREW ONBOARD AND TRANSLATE INTO THE LANGUAGES UNDERSTOOD BY THE CREW.
Lifesaving
Issued 5 October 1997
Resolved
DEMONSTRATE OPERATION OF THE GENERAL ALARM SYSTEM.
Lifesaving
Issued 5 October 1997
Resolved
PROVE OPERTAION OF PORT/AFT WATERLIGHT.
Fire Fighting
Issued 5 October 1997
Resolved
UPDATE FIRE CONTROL PLAN TO SHOW LOCATION OF INT. SHORE CONNECTION AND MARKWITH CORRECT SYMBOL.
Navigation
Issued 5 October 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CURRENT CHARTS 11412 AND 11417 FOR TAMPA AREA. NO TAMPA US CHARTS OR FOREIGN EQUIVALENTS WERE ONBOARD PRIOR TO ENTERING PORT. AGENT PROVIDED CHARTS TO MASTER UPON ARRIVAL TO TAMPA.
Lifesaving
Issued 5 October 1997
Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL.
Lifesaving
Issued 5 October 1997
Resolved
REMOVE EXCESSIVE OIL FROM LIFEBOAT BILGE.
Lifesaving
Issued 5 October 1997
Resolved
REPLACE MISSING GRABLINES ON LIFEBOAT.
Lifesaving
Issued 5 October 1997
Resolved
REPAIR LIFEBOAT SHAFT PACKING SO PROPELLER DOES NOT HIT ROPE GUARD.
Construction/Loadline
Issued 5 October 1997
Resolved
PROVIDE PROPER CLOSURE OF VENT DAMPERS, INBOARD OF LIFEBOAT. SLATS DO NOT CLOSE SUFFICIENTLY.
Lifesaving
Issued 5 October 1997
Resolved
PROVIDE CLASS SOCIETY ASSESMENT OF REPAIRS/CRACKS/FRACTURES TO LIFEBOAT HULL.
Fire Fighting
Issued 5 October 1997
Resolved
PROVE INTEGRITY OF ALL FIRE HOSES AND ATTACH NOZZLES TO ALL HOSES.
Lifesaving
Issued 5 October 1997
Resolved
PROVE PROPER OPERATION OF LIFEBOAT DAVIT, LOWER BOAT AND RELEASE BOAT.
Fire Fighting
Issued 5 October 1997
Resolved
PROVIDE FIRE RETARDENT TENDING LINE TO FIRE SUIT.
Construction/Loadline
Issued 5 October 1997
Resolved
MAKE REPAIRS/PROVE WATERTIGHT INTEGRITY OF THE FOLLOWING VENT CLOSURES: 1. AFT BALLAST TANK VENT HEAD, WASTAGE. 2. HFO PB FUEL TANK, FLAME SCREEN AND VENT HEAD WASTED. 3. COFFERDAM VENT WASTED. 4. GOOSE NECKS ON BOW AND STERNINOP. 5. PAINT LOCKER DOOR DOGS NEED ADJUSTING. 6.VENT CLOSURE OUTBOARD #1
Construction/Loadline
Issued 5 October 1997
Resolved
REPLACE/REPAIR DAMAGED HANDRAIL SECTION, PORTSIDE, AFT, FORWARD OF BIT WHERE ROPE RETAINER IS IN PLACE.
Lifesaving
Issued 5 October 1997
Resolved
PROVIDE SOLAS TRAINING MANUAL IN LANGUAGE OF CREW(RUSSIAN AND SPANISH).
Electrical
Issued 22 July 1997
Resolved
Conduct temporary repairs to #2 generator motor to satisfaction of Class Society and US Coast Guard prior to departure.
Fire Fighting
Issued 22 July 1997
Resolved
Provide servicing for following items: Fixed CO2 system, Firefighting suitbreathing apparatus, portable dry chemical extinguishers.
Fire Fighting
Issued 22 July 1997
Resolved
Install port fire pump and test to satisfaction of USCG, prior to departurefrom Savannah, GA
Electrical
Issued 22 July 1997
Resolved
Conduct repairs to #1 generator engine to satisfaction of class society andUSCG, prior to departure.
Fire Fighting
Issued 22 July 1997
Resolved
Remove faulty starter motor from emergency fire pump engine. Repair all exposed wiring on emergency fire pump engine.
Lifesaving
Issued 22 July 1997
Resolved
Remove oil from engine room bilge
Electrical
Issued 22 July 1997
Resolved
Conduct permanent repairs to #2 generator engine to satisfaction of class society and USCG by 30Sep97
Navigation
Issued 27 May 1997
Resolved
Vessel missing navigational charts for Houston transit.
Navigation
Issued 27 May 1997
Resolved
Vessel's List of Lights not corrected.
Navigation
Issued 27 May 1997
Resolved
Vessel's gyrocompass inoperable. Vessel had Radio Holland come onboard_x001C_ to repair the unit. The unit required parts from Romania and subsequently requested that the vessel sail. The vessel was granted a Letter of Deviation under the condition that unit would be repaired by next US port.
Lifesaving
Issued 27 May 1997
Resolved
Vessel's lifeboat on starboard side had improper stowage of equipment in its interior.
Navigation
Issued 27 May 1997
Resolved
Vessel missing maneuvering information in the wheelhouse._x001C_
Accommodation/Occupational Safety
Issued 27 May 1997
Resolved
Vessel's MSD discharge pump was inoerable.
Lifesaving
Issued 27 May 1997
Resolved
One of the vessel's fireman's suits was missing a protective lens.