AN DA JIANG

AN DA JIANG is a 1986 tank ship. The Coast Guard has recorded 5 inspections since 1997, most recently in September 2006, along with 6 deficiencies.

Records from 1997 to 2006. Most recent: inspection, 26 September 2006.

Built
1986
Last inspected
26 September 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8720773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
457416
Flag
CHINA
—
Maury page id
psix-457416

Inspections, by type

…with no type recorded2
Years with a record 3 calendar years (1997–2006)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3951 - Convention (Subpart B), Gross Ton
1285 - Convention (Subpart B), Net Ton
4926 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

26 September 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2787573
18 July 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2717070
24 May 2006 MARPOL Annex I Examination · COC-TVE Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2653554
22 January 2005 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2279225
1 June 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 404343

Deficiency record · 6

Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2006 Resolved
Double shielded lighting missing throughout engine room, steering gear room fuel oil seperator room and mechanic shop. To be recitified in 30 days to the satisifaction of the class society survey. SOLAS Consolidated 2004 II-l/45.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 18 July 2006
Resolution: Boarded vessel and walked around affected areas to examin all lights. All were properly shielded. Deficiency Cleared.
Lifesaving › Lifeboat › Fire Protection (general)
Issued 1 June 1997 Resolved
While inspecting the vessel's logs, it was observed that the monthly inspection of the life saving appliances, including lifeboat were not entered. Specific Cite: SOLAS 74 (ammend) CH. III/Reg. 19.7_x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 1 February 2005
Resolution: REVIEWED THE SHIP''S MONTHLY SAFETY INSPECTION LOGS, ALL SAT.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 1 June 1997 Resolved
While conducting a PSCI annual exam, it was obderved in the vessel's bridgelog that the weekly general ship alarms were only being conducted once a month. Specific Cite: SOLAS 74 (ammend) CH. III/Reg.19.6.3._x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 1 February 2005
Resolution: REVIEWED SHIP''S BRIDGELOG FOR WEEKLY TESTS OF THE GENERAL ALARM. ALL SAT.
Lifesaving › Lifeboat › Propulsion Engine
Issued 1 June 1997 Resolved
While ispecting the vessel's bridge logbook, it was observed that the engines on the lifeboats were being conducted monthly instead of weekly. Spewcific Cite: SOLAS 74 (ammended) CH. ```/Reg.19.6.2._x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 1 February 2005
Resolution: REVIEWED BRIDGE LOGBOOK FOR MONTHLY LIFEBOAT ENGINE TESTS, ALL SAT.
Fire Fighting › Fire Hoses › Location
Issued 1 June 1997 Resolved
During the inspection of the fire stations, it was observed that the spanner wrenches for all the fire stations were missing. Specific Cite: SOLOAS 74 (ammended) CH. II-2/Reg. 21.
Condition: Unknown
Due 1 July 1997
Resolved 1 February 2005
Resolution: CHECKED ALL FIRE STATIONS FOR HOSES AND SPANNER WRENCHES, ALL SAT.
Fire Fighting › Fire Patrol › Call Points
Issued 1 June 1997 Resolved
While conducting a PSCI annual exam it was observed that the log entries for the monthly fire drills were not entered. Specific Cite: SOLAS 74 (ammend) CH. III/Reg. 18.5_x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 1 February 2005
Resolution: REVIEWED THE SHIP''S MONTHLY LOG BOOKS FOR FIRE DRILLS, ALL SAT.

Ownership record