Records from 1997 to 2025. Most recent: inspection, 16 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
16 September 2025
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8202948
12 June 2024
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7922450
8 September 2023
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7787555
4 October 2022
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7570463
30 August 2021
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7300182
20 July 2020
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7024597
20 June 2019
Drydock Exam · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6711244
26 July 2018
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6826377
28 September 2017
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6277758
24 June 2016
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5976735
10 August 2015
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5228512
6 May 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4851776
12 March 2014
Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4849014
29 May 2012
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4327620
7 May 2009
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3473200
15 April 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3426570
14 April 2008
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3183714
21 March 2007
Administrative Inspection · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2892042
18 May 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2626421
5 August 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452367
21 June 2005
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2397317
23 October 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1914539
9 September 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1673662
18 June 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1632929
13 May 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1064156
9 August 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1113112
8 July 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1449202
22 February 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 795541
16 December 1997
Hull Examination · Initial Certification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364960
1 December 1997
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788559
18 August 1997
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1122957
2 April 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374940
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2025
Resolved
Propulsion machinery must be capable of operating at constant marine load. PORT engine lost propulsion while getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2025
Resolved 19 September 2025
Resolution: Conducted sea trial. PORT engine working satisfactory.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 September 2025
Resolved
Shutoff valves must be fitted in the fuel supply lines. PORT remote shutoff valve is unsatisfactory.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2025
Resolved 19 September 2025
Resolution: Installed new shutoff valve. Satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2025
Resolved
Openings for fill pipes and hoses must be connected to close to engine connections. Center fuel tank has no connections to engines and no shutoff valves. Tank must be capped or plugged at fill to not be used.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2025
Resolved 19 September 2025
Resolution: Center fuel tank fill has been capped and can not receive fuel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2025
Resolved
A lifejacket must be provided for each person carried onboard. Only (8) PFDs onboard vessel. Vessel limited to total of 8 persons.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 19 September 2025
Resolution: Vessel has onboard 10 satisfactory PFDs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2024
Resolution: Verified valid MMC.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 June 2024
Resolved
12 Coast Guard approved hand red flare distress signals OR Six red hand flares and Six orange smoke distress signals are required to be on board. Distress signals were missing, provide valid CG approved distress signals and maintain onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 November 2024
Resolution: Verified valid flares were available.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2024
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Conduct abandon ship, fire, man overboard drills with crew, and document in your vessel's log book.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2025
Resolution: Satisfactory fire and MOB Drill conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2023
Resolved
All on board flares were expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2023
Resolved 27 September 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or equivalent and stowed in a suitable water tight container that it is marked "First-Aid Kit". Provide evidence of First aid kit located on board and readily available.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 October 2022
Resolved 13 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 October 2022
Resolved
A vessel of more than 26 feet in length must carry a minimum of one life buoy of not less than 24 inches in diameter and approved in accordance with 160.150. On board ring life buoy was cut open. Provide new ring buoy as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2022
Resolved 13 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2021
Resolved
The three 2.5 gallon fire buckets required on vessels with no power driven fire pumps must have an attached lanyard. Fire buckets onboard did not have lanyards attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2021
Resolution: Verified lanyards on fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material arranged IAW IMO Resolution A.658(16). Vsl name markings covered portions of retroreflective tape. Remove stickers and remark RLB with vsl name without obscuring retroreflective materials.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2021
Resolution: Verified RLB marking not covering retro tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2021
Resolved
Placards containing instructions for the donning and use of life jackets onboard the vessel must be posted in a conspicuous location visible to passengers. No life jacket donning placard was onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2021
Resolution: Verified PFD donning placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 September 2021
Resolved
Vessel must carry an approved first aid kit. No first aid kit onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2021
Resolution: Verified first aid kit available.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2021
Resolved
Abandon ship, man overboard, and fire fighting drills are to be logged. Vessel did not have a logbook onboard. New log book to be started today. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
Resolution: Log book to be started on this day.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 September 2021
Resolved
Installed radio not inspected IAW GLA. Any vsl carrying more than 6 PAX for hire must complete an inspection of the radio telephone installation every 13 months as required by the GLA. IAW 47 CFR 80.953(a)
Def changed to 701 during winter lay-up.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2022
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 28 September 2017
Resolved
Pre-engineered fire extinguishing system did not shut down ventilation or main engines when tested.
Action required: 705 - Other - as specified
Due 29 October 2017
Resolved 26 July 2018
Resolution: tested satisfactory.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 May 2014
Resolved
Vessel not documented due to change in ownership. Certificate of documentation applied for.
Due 30 May 2014
Resolved 20 June 2014
Resolution: Proper documentation with coastwise endorsement sighted.
Engineering › Bilge Water Management System › Hose
Issued 1 May 2014
Resolved
Bilge discharge hose crimped due to inadequacy of service type. Renew with hose of substantial construction.
Due 30 May 2014
Resolved 1 July 2014
Engineering › Fuel Oil Service System › Filter
Issued 1 May 2014
Resolved
Fuel filter tostbd eng not securely fastened, refasten to prevent movement.
Due 30 May 2014
Resolved 20 June 2014
Resolution: Mounted securely
Fire Fighting › Ventilation Systems › Ducts
Issued 1 May 2014
Resolved
Power ventilation ducts are not constructed of rigid, non-combustible material. Renew same with proper type.
Due 30 May 2014
Resolved 20 June 2014
Resolution: Ducting renewed with rigid non combustible material.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 March 2014
Resolved
Ring buoy not fitted with waterlight CG approval 160.010
Due 1 July 2014
Resolved 1 July 2014
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 12 March 2014
Resolved
Provide adequate anchor and line.
Due 1 July 2014
Resolved 1 July 2014
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 March 2014
Resolved
Mark vessel's name onto ring buoy and pfds.
Due 1 July 2014
Resolved 1 July 2014
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 March 2014
Resolved
Vessel operator did not have license available.
Due 1 July 2014
Resolved 23 June 2014
Resolution: Mater <25 GT issued.
Communications › Audible Communications › Horn/Whistle
Issued 12 March 2014
Resolved
Vessel not equipped with horn.
Due 1 July 2014
Resolved 1 July 2014
Resolution: vessel carries portable air horn.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 March 2014
Resolved
Vessel as platform is adequate only when equipped with proper available ladder.
Due 1 July 2014
Resolved 1 July 2014
Resolution: Rigid portable swim ladder provided
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 15 April 2009
Resolved
No designation in writing for qualified deck hands (High Speed)
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Engineering › Bilge Water Management System › Not Operational
Issued 15 April 2009
Resolved
Forward compartment bilge alarms (3) did not provide a visual or audio alarm.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Accommodation/Occupational Safety › Ventilation › General
Issued 15 April 2009
Resolved
Engine compartment ventilation intake lines were not positioned at the lowest point of the compartment.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2009
Resolved
Replace expired items in first aid kit (aspirin, iodine, burn cream, eye dressing)
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 19 May 2009
Resolution: Vessel operator faxed document showing purchase of new first aid kit items.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 April 2009
Resolved
Deck seating bolts loose. Also, fiberglass mount for port forward seat cracked at both sides of base.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 15 April 2009
Resolved
Repair inoperable VHF radio.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 April 2009
Resolved
Outer protective cover for manual pull cable for fixed fire fighting system was deteriorated and in need of replacement.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 7 May 2009
Engineering › Fuel Oil Service System › Tank
Issued 15 April 2009
Resolved
Vapor detector sensors did not actuate alarm panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2009
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 14 April 2008
Resolved
Blower Motors and hose assemblies broken or un-attached from hull of vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Resolution: all blower motors/hosed replaced and refastened to hull of vessel.
Accommodation/Occupational Safety › Ventilation › General
Issued 23 May 2007
Resolved
Forward bilge vent motors inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Engineering › Fuel Oil Service System › Tank
Issued 23 May 2007
Resolved
Forward vapor alarm inoperable for fuel tanks (Gasoline)(.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 May 2006
Resolved
Replace fuel shutoff valve handles on all tanks (3).
Action required: 705 - Other - as specified
Due 22 July 2006
Resolved 15 April 2009
Resolution: During annual inspection did not note any discrepancies with fuel shutoff valve handles.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 May 2006
Resolved
Provide Nav Pubs--CG Light List.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 30 June 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 October 2003
Resolved
Update and carry onboard charts, notice to mariners, Coast Pilot, CG Light List, Tide Tables.(46CFR 184.420)
Action required: 705 - Other - as specified
Resolved 22 June 2006
Documentation › Logs/Records › Logbook (official)
Issued 23 October 2003
Resolved
Provide proof that the Lifesaving inspection log (46CFR 185.722, 728(c) ), Drill / Crew training log (46CFR 185.520 & 524), Senior Deckhand letter, Crew passenger count (46CFR 502 & 504) ,voyage plan is updated and utilized (46CFR 185.503)
Action required: 705 - Other - as specified
Resolved 22 June 2006
Lifesaving › Hand Flares
Issued 23 October 2003
Resolved
Provide 2 orange smoke flares. (46CFR 180.68) LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2004
Resolution: Requirement satisfied via fax to SFCMS office.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 23 October 2003
Resolved
Provide proof of service for fixed fire system in way of fuel tank space. (46CFR 181.400)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2004
Resolution: Requirement satisfied via fax to SFCMS office.
Construction/Loadline › Hull
Issued 9 September 2002
Resolved
Complete drydock and internal structural exams prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2007
Resolved 23 October 2003
Resolution: Vessel completed Annual and Hull exam on 23 October 2003.
Documentation › Certificates/Documents
Issued 19 June 2002
Resolved
Provide current Certificate Of Documentation.
COD expired 05/01 LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2002
Resolution: Expires 30JUN03
Documentation
Issued 19 June 2002
Resolved
Provide stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2002
Resolution: Faxed copy of stability letter.
Documentation › Logs/Records
Issued 19 June 2002
Resolved
Provide Training Record IAW 46 CFR 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Documentation › Manuals/Policy Documentation
Issued 19 June 2002
Resolved
Post Emergency Instructions IAW 46 CFR 185.510.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Communications › Audible Communications
Issued 19 June 2002
Resolved
Provide a sound signaling device. (Horn/WHistle) LEGACY COMPONENT DESC: Horn/Whistle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 June 2002
Resolved
Renew all expired items in first aid kit, IAW 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Lifesaving › Lifebuoys
Issued 19 June 2002
Resolved
Renew inop waterlight on ring life buoy. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Lifesaving › Lifebuoys
Issued 19 June 2002
Resolved
Install a corrosion resistant clip to attach waterlight to ring life buoy. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 June 2002
Resolved
Provide documentation for annual servicing of all fire extinguishers. (Fixed and portable)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Communications › Radio Communications
Issued 19 June 2002
Resolved
Install required VHF Radio.
Portable radio onboard for inspection. Permanently installed radio missing. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Documentation › Manuals/Policy Documentation
Issued 19 June 2002
Resolved
Provide formalized documentation of provisions of drug and alcohol testing program, and employees enrolled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Construction/Loadline
Issued 8 July 1999
Resolved
INSTALL AUDIBLE HIGH LEVEL BILGE ALARM I.A.W. 46 CFR 182.530.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999