MAURY USCG vessel records
← All vessels

ELWHA

Built
1968
Last inspected
6 February 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 February 2025
…with no type recorded1
…past their stated due date9
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8835358
WY3960
Flag
UNITED STATES
Maury page id
psix-45746

Documentation record

Registered dimensions (L × B × D)368.1 ft × 73.2 ft × 24.7 ft
Registered tonnagegross 2,812 / net 1,322
ITC dimensions (L × B × D)368.1 ft × 73.2 ft × 24.7 ft
ITC tonnagegross 8,275 / net 6,281
BuilderNAT'L STEEL & SHIPBLDG CO · SAN DIEGO, CA, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEVERETT, WA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2812 - Regulatory (Subpart C or D), Gross Ton
8275 - Convention (Subpart B), Gross Ton
1322 - Regulatory (Subpart C or D), Net Ton
6281 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 47 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each, 10 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 47

6 February 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8075699
30 May 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7739903
24 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7357309
27 January 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6896962
29 September 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6825027
9 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6784399
17 July 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6753700
12 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713360
5 May 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6679115
23 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6670443
15 January 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6610879
4 January 2019 Deficiency Check · Internal Structural Exam · MARPOL Annex I Examination · Underwater Inspection in lieu of Drydock · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605601
26 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6602796
6 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6593313
3 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6591295
31 October 2018 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6572031
3 October 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6554953
12 March 2018 Inclining Experiment · Administrative Inspection · Internal Structural Exam · Deadweight Survey · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6388344
11 January 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6338722
6 January 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6333455
14 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6325087
19 October 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291988
16 August 2017 MTSA/ISPS Verification · Damage Survey · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6244847
3 July 2017 Security Breach
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6201244
3 July 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6285592
14 June 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6178546
5 June 2017 MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6163294
22 May 2017 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6169244
4 May 2017 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6168474
16 April 2017 Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131402
3 April 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117071
14 March 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100772
13 March 2017 Administrative Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6104831
1 March 2017 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6098728
9 February 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6085326
25 January 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6102182
15 December 2016 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6073156
7 December 2016 MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6054247
1 December 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6051024
3 October 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6015218
6 September 2016 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5996537
6 September 2016 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6001630
26 July 2016 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5962377
21 June 2016 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5913769
16 March 2016 Administrative Inspection · Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5833935
9 February 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821368
28 January 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5805641

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020 No resolution recorded
Crew found pin hole leaks in bilge system. Temporary patches put in place for now. Full repairs need to be completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2020 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 February 2020 No resolution recorded
+Make the vessel ready for inspection. No deck crew was provided the 2nd day of the COI inpsection. Provide a deck crew to verify logs, manuals, and safe navigation equipment. 46CFR71.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2020 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2020 No resolution recorded
Vessel's on international voyages must comply with the applicable international Convention e.g. SOLAS, MARPOL. Make the vessel ready for inspection to include dry-dock and structural integrity. 46CFR70.05-10
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 7 February 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 February 2020 No resolution recorded
Vehicular decks must be fitted with a sprinkler system. After 04 attempts the system failed due to restricted flow. Prove proper operation of the system prior to the carriage of vehicles. 46CFR76.05-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 February 2020 No resolution recorded
Prove proper operation of the machinery space Hi-fog system. The high pressure pump prxxxxxxx bled-by during test. 46CFR76.01-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2020 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › General alarm
Issued 7 February 2020 No resolution recorded
Make the general alarm signal (red light) located in both motor rooms. 46CFR113.25-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 February 2020 No resolution recorded
Repair the fire detection system. As identified in the manufactures service repairs. 46CFR76.27-15 , 46CFR76.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2020 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 February 2020 No resolution recorded
Repair the upper passenger deck sprinkler alarms. No alarms were indicated during test. 46CFR76.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2020 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 August 2019 No resolution recorded
Provide repair proposal for laid out steal work IWO of vehicle deck. Repair access cuts in vehicle deck.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 February 2019 No resolution recorded
02117 / 46 CFR 71.55-1 / 705c (by 31July19) - UT gauge report#47210, dated February 8, 2019, identified several areas of significant corrosion on #2 end lower vehicle deck. Repairs must be made to #2 end lower vehicle deck in accordance with repair proposal submitted by [name withheld] on February 20, 2019.
Action required: 705 - Other - as specified
Due 31 July 2019 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 31 October 2018 Resolved
Provide an updated ECDIS. The system has not been updated more than 6 months ago.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 October 2018 Resolved
Provide lifejackets approved under approval series 160.155, 160.176, or 160.166. The jackets inspected were approved under 160.055 for vessels not subject to SOLAS.
Condition: Placed in Improper Service
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 October 2018 Resolved
Mark lifesaving equipment stowage locations with the appropriate symbols from IMO RES.A.760(18). The equipment located in both pilot houses were not marked.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 2 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2018 Resolved
Prove that the lifebuoys used in the quick release configuration have a mass not less than 4 KG.
Condition: Placed in Improper Service
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 31 October 2018 Resolved
Prove the proper operation of the vessel's voyage data recorder. The alarm unit in the "off-line" pilot house displayed "82" data failure.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 31 October 2018 Resolved
Provide a dependent power supply for the signal lamp. The battery could not be located.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 31 October 2018 Resolved
Provide an echo sounding device.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
01 - Certificates & Documentation › 013 - Documents › SAR co-operation plan for pass. ships on fixed trade
Issued 31 October 2018 Resolved
Provide an international code of signals and an IAMSAR manual.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Emergency equipment for 2-way comm.
Issued 31 October 2018 Resolved
Provide (3) two way VHF radio telephone apparatus.
Action required: 702 - Prior to embarking on international voyage
Due 30 November 2018
Resolved 30 November 2018
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 31 October 2018 Resolved
Provide a SART.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 31 October 2018 Resolved
Provide a bearing compass device.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 31 October 2018 Resolved
Provide the historic on board training records for abandon ship, fire, damage control, and pollution response drills and training.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 October 2018 Resolved
Provide a two way on scene radio using the aeronautical frequency 121.5 & 123.1 MHZ.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2018
Resolved 6 May 2019
Resolution: Observed onboard by [name withheld] & [name withheld] on means to communicate to air assets.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 31 October 2018 Resolved
Provide a valid safety management certificate.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2018 Resolved
Replace the deteriorated retro-reflective material on the life buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2018
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 31 October 2018 Resolved
Provide lifesavings equipment maintenance records.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 31 October 2018 Resolved
Complete MARPOL survey, SOPEP and garbage records could not be located.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 31 October 2018 Resolved
Provide a ladder for the No.1 end rescue boat.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2018
Resolved 30 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2018 Resolved
Make repairs to the sewage aeration blower and No.1 end thrust bearing pump to trip during CO2 activation.
Action required: 705 - Other - as specified
Due 9 May 2019
Resolved 19 February 2019
Resolution: New shunt breaker installed and tested at the annual.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 31 October 2018 Resolved
The markings from the exterior upper passenger deck does not adequately direct passengers to the assembly stations. Provide signage to direct passengers down stairs.
Action required: 702 - Prior to embarking on international voyage
Resolved 30 November 2018
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 31 October 2018 Resolved
Provide an EPIRB.
Action required: 702 - Prior to embarking on international voyage
Due 30 December 2018
Resolved 6 May 2019
Resolution: 46CFR 199.10, Passenger Sub-Chapter H vessel on short int'l voyage need only comply with Subchapter W subpart A, B, C. EPIRB is under 46CFR Subchapter W, subpart E, therefore not required. DEF removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 October 2018 Resolved
Make repair to FSD 29. Unable to close.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2018
Resolved 30 November 2018
Engineering › Steering Gear System › Differential Assembly
Issued 19 October 2017 Resolved
Properly replace throttle hand assembly on #2 end pilothouse. Conduct sea trials verifying no additional throttle differential alarms received.
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 20 October 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 April 2017 Resolved
Rear seal on #1 fire pump blew out. Prove proper operation of #1 fire pump.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 16 August 2017
Resolution: Fire pump rear seal was replaced in kind. Operational testing was sat.
Communications › Audible Communications › SPD (Other)
Issued 14 March 2017 Resolved
EOT power failure alarm in both pilot houses not equipped with audible function. Provide audible alarm IAW 46CFR113.35-5(e)(1).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 19 April 2017
Resolution: Alarm tested. all sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 March 2017 Resolved
Both drive motors supply ventilation dampeners remote closers not working. Repair remote closure IAW 46CFR76.15-1(a).
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Dampeners remote closures were repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 14 March 2017 Resolved
Engine room CO2 system discharged. Recharge and restore system IAW 46CFR76.05-1(a)table.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2017
Resolution: Co2 system recharged and inspeted by third party.
Fire Fighting › Combustible Materials › Insulation
Issued 14 March 2017 Resolved
Structural fire protection insulation removed/missing from A-60 boundary below both pilot houses. Restore boundary to A-60 IAW 46CFR72.05-10(a)table.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 19 April 2017
Resolution: All sat.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 14 March 2017 Resolved
Accommodation sprinkler system zone flow alarms not working repair alarms IAW 46CFR76.25-35
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Zone flow alarms were repaired.
Fire Fighting › Fire Main › Valves
Issued 14 March 2017 Resolved
Replace the following valves: top valve FS 11, top valve FS 14, bottom valve FS 24.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2017
Resolution: Valves were replaced.
Stability › Weathertight Integrity › General
Issued 14 March 2017 Resolved
Install the following doors: both PH exterior doors, door beside FS 18.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2017
Resolution: All doors were replaced.
Construction/Loadline › Structures › Deck Plating
Issued 1 March 2017 Resolved
Deck hatch access for #1 Steering gear space require UT shots to determine wastage near upper RH corner as looking at #1 end.
Due 31 March 2018
Resolved 30 October 2018
Construction/Loadline › Structures › Deck Plating
Issued 1 March 2017 Resolved
Provide permanent repairs and proposal to address 4 holes & thin deck on upper passenger deck.
Due 31 March 2018
Resolved 30 October 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 March 2017 Resolved
Repair and identify all corroded hand rail stanchions on outside passenger decks.
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 16 August 2017
Resolution: All wasted hand rail stanchions were replaced 100% at the bottom 6" and found sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 December 2016 Resolved
Repair damaged embarkation lights on upper vehicle decks: 2 lights extinguished, 2 lights with cracked/corroded housings, 4 lights shining on vehicle deck and not illuminating area around vessel).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 3 January 2017
Resolution: Replaced correoded fixtures, relamped burnt bulbs, positioned lights correctly.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 October 2016 Resolved
Crew must complete manual draft readings twice a day, once at the start of operations and again at the end of operations. Additionally, if any unusual listing occurs crew must complete manual draft readings to ensure they are within the correct range IAW the vessels stability letter. 46 CFR 78.17-22
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 3 February 2017
Resolution: Received notification from WSF [name withheld] that the sensors for the draft reading system were replaced during the vessels dry dock availability.
Engineering › Bilge Water Management System › Piping
Issued 6 September 2016 Resolved
All vessels shall be provided with satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Provide permanent fixture to 4" bilge suction pipe that was found to have pin-sized hole, satisfactory to Coast Guard Marine Inspector (46 CFR 56.50-50 (a)).
Action required: 705 - Other - as specified
Due 25 September 2016
Resolved 23 September 2016
Resolution: Cropped and inserted new pipe.
Fire Fighting › Fire Main › Condition
Issued 21 June 2016 Resolved
Discovered pin hole in fire main in engine room #1. Remove and replace portion of bad pipe. 46 CFR 76.10-15
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 February 2017
Resolution: Received email from Cheif Engineer with pictures attached depicting satisfactory permanent repair.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 March 2016 Resolved
Battery bank was being replaced; inspectors were not able to test navigation lights, fire screen doors, water tight doors, general alarm. Test all systems to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2016
Fire Fighting › Fire Pumps › Arrangement
Issued 17 March 2016 Resolved
Fire pump was removed for servicing. Replace fire pump to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2016
Resolved 31 March 2016
Resolution: Replaced fire pump. Tested. All sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.