CAPT LOU VII

CAPT LOU VII is a 1997 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1997, most recently in April 2026, along with 110 deficiencies and 3 casualty investigations between 2010 and 2024.

Records from 1997 to 2026. Most recent: inspection, 21 April 2026.

Built
1997
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE 4466
457529
Flag
UNITED STATES
367353560
Maury page id
psix-457529

Inspections, by type

…with no type recorded3
Years with a record 28 calendar years (1997–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.0 ft × 22.7 ft × 8.0 ft
Registered tonnagegross 94 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAVER SHIPWORKS CORP · ARUNDEL · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFREEPORT, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 13 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Simplified, Gross Ton
75 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE4466MMSI 367353560 · active · compulsorily equipped · granted 16 February 2018, expires 1 May 2028
WCX5674MMSI not assigned · expired · voluntarily equipped · granted 25 June 1997, cancelled 25 August 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 44

21 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8352932
28 April 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8121250
23 April 2025 Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116413
31 March 2025 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8102657
22 September 2024 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8007665
21 September 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8011967
11 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7932333
13 June 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7656134
5 April 2023 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663352
13 June 2022 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7451918
10 May 2021 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7193090
21 April 2021 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7197129
20 August 2020 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906977
15 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6638577
2 April 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6669776
19 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379297
10 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6142763
8 May 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6141796
6 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5880465
17 September 2015 Administrative Inspection · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5761120
2 June 2014 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4876831
11 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4337392
28 November 2010 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3932898
9 April 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3449418
29 April 2008 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3195189
16 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2931846
4 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2900851
8 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2643446
27 April 2005 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2343858
5 April 2005 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2326621
19 August 2004 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2163819
11 March 2004 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2027740
4 August 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1866661
20 March 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1759439
13 August 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1660220
28 August 2001 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1435270
2 March 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1384686
22 May 2000 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410324
9 June 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1471389
2 March 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406443
30 June 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127212
5 June 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 775267
3 June 1997 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 774363
3 June 1997 Hull Examination · MARPOL Annex V Examination · Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 775010

Deficiency record · 110

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2026 Resolved
1st aid kit meds expired.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2026
Resolved 21 April 2026
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 April 2025 Resolved
needed 6 red hand flares - corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2025
Resolved 28 April 2025
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2025 Resolved
needed 2 replacement life rings as the current ones were not in serviceable condition - corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2025
Resolved 28 April 2025
Resolution: Purchased new
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 April 2025 Resolved
needed hydrostatic release for EPIRB - corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2025
Resolved 28 April 2025
Resolution: Purchased new.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 April 2025 Resolved
needed publications
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2025
Resolved 28 April 2025
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 April 2025 Resolved
needed 2 spanner wrenches
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 23 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2025 Resolved
Needed correct batteries for the water lights
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 23 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 22 September 2024 Resolved
While operating in passenger service vessel struck the Medowbrook PKWY drawbridge resulting in damage to the mast, radar, lighting and associated wiring. Vessel rep is required to repair/replace all damaged equipment to original design. Prove proper installation/ operation of all equipment damaged by bridge striking event to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2024
Resolved 27 September 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 June 2023 Resolved
Provide a copy of the light list or excerpts for the area transited.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 30 June 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 June 2023 Resolved
Provide a first aid kit with all required items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 30 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2023 Resolved
Each SM-3 floating waterlight is required to have Energizer Lithium AA's.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2023
Resolved 13 June 2023
Resolution: Installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 June 2023 Resolved
Ensure EPIRB checks are logged monthly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 14 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 June 2023 Resolved
Install UL-217 rated interconnected smoke detectors in E/R, main galley area & bridge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2023
Resolved 30 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2023 Resolved
Re-label lifering by bridge with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 30 June 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 June 2023 Resolved
High water bilge alarms (visible & audible) should work correctly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2023
Resolved 13 June 2023
Resolution: Corrected during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2023 Resolved
All lifejackets are required working lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2023
Resolved 13 June 2023
Resolution: Corrected during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 June 2022 Resolved
Life Float required IAW Table 180.200(c). Replace Life Floats prior to operating beyond a limited coastwise route in warm waters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2022
Resolved 27 June 2022
Resolution: O/O bought new LF and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard. 46CFR183.330(f).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 27 June 2022
Resolution: Non conductive mats were inplace.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent the electrical ignition of flammable vapors. Two lights in the engine room were missing electrical caps that exposed wiring. One light was missing. 46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 27 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2022 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard. A light in the engine room was missing a guard. 46CFR183.410(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 27 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 June 2022 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practical and made watertight. In the fuel tank space, the forward bulkhead had three non-watertight penetrations. In Engine Room, aft bulkhead had non-watertight penetration. 46CFR179.320(c).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 27 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022 Resolved
Each life jacket on a vessel on oceans or coastwise route must have a life jacket light approved IAW 46CFR160.012. Three life jacket lights were nonoperational. Replace three life jacket lights. Max persons onboard is 156 until three life jacket lights are replaced. 46CFR180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2022
Resolved 27 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2022 Resolved
Vessel over 65’ is required to have a commercial grade fire hose. Starboard fire hose had a leak. Replace in kind. 46CFR181.320
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 13 June 2022
Resolution: Master bought and installed new fire hose the day of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 June 2022 Resolved
A vessel on an oceans, coastwise, or limited coastwise route must carry six hand red distress flares and six hand orange smoke distress flares. Flares onboard were expired. 46CFR180.68(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 13 June 2022
Resolution: Master had new flares before MI departed the SPV.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 June 2022 Resolved
Navigation Rule 20, Rules in this Part shall be complied with in all weathers. Navigation light bulb was extinguished and needs to be replaced. 33CFR83.20
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 13 June 2022
Resolution: Master had navigation light in working order before MI departed the SPV.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 May 2021 Resolved
Identified float light for the life float missing watertight retaining clips. on the top. replace the float light with an approved float light in accordance with 46 CFR Subchapter Q (161.010)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 24 May 2021
Resolution: New float lights purchased and installed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 May 2021 Resolved
Identified the forward STBD life float retention basket straps wasted. Repair or replace the baskets straps with an equivalent securing strap or in accordance with manufacturer’s specifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 24 May 2021
Resolution: new strap for the subj. life float installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021 Resolved
Identified 1 child size PFD missing the clip to secure the PFD to the body. Remove the PFD from service and replace the PFD. Prior to carrying more than 15 children replace the child sized PFD IAW the vessel’s COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 24 May 2021
Resolution: New Child sized PFD provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021 Resolved
Each life jacket carried on a vessel on an Oceans or Coastwise route must have an approved life jacket light, approved in accordance with 46 CFR 161.012. Identified PFDs with out life jacket lights as previously authorized due to life float and other coastwise and ocean requirements. Outfit every type I PFD on board with life jacket lights Prior to operations on Coastwise routes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 2 June 2021
Resolution: PFD lights provided for all PFDs for route and conditions. (oceans)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 August 2020 Resolved
Install position data NEMA cord for GPS position data to x-mit to the programed DSC VHF-fm marine radio.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 19 September 2020
Resolution: NEMA cable installed and photo evidence of position data in the VHF-fm DSC radio provided.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 August 2020 Resolved
Life jacket donning instructions not posted. Post donning instructions for each type of PFD on both decks of the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 19 September 2020
Resolution: Placards posted as required.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 August 2020 Resolved
EPIRB battery expired Feb 2020. Restrict operations to less than 3 miles from shore until battery is replaced. Establish and maintain EPIRB maintenance log to prevent future occurance.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 19 September 2020
Resolution: New EPIRB purchased and registered. Scan of new registration form sent.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 August 2020 Resolved
Post COI in the passenger compartment where most visable to passengers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 19 September 2020
Resolution: COI posted in the passenger compartmebnt IAW regulation
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 August 2020 Resolved
Remove or secure microwave in the galley area of the vessel. Microwave not secured was identified as a serious falling overhead hazard if subject to dynamic external forces.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 August 2020
Resolved 20 August 2020
Resolution: Required O/O to correct the deficiency prior to my departure to prevent serious injury.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2020 Resolved
Identified navigation lights wired using wire nuts to connect lights to the power source. Re-wire lights using butt connectors under shrink wrap as specified in 46 CFR 183
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2020
Resolved 19 September 2020
Resolution: New navigation light and installed IAW standards listed in 46 CFR subchapter T for electrical.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 6 May 2016 Resolved
Provide copy of valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 8 June 2016
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 May 2016 Resolved
Provide copy of valid vessel FCC Bridge to Bridge Certificate.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 8 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 6 May 2016 Resolved
Prove proper operation of DSC test function on VHF, in accord with MSIB.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 8 June 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 6 May 2016 Resolved
Properly label bilge high water alarms. (1-FWD, 2-Engine, 3-Laz, 4-Fuel)
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 8 June 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2014 Resolved
Repair or replace bilge alarm panel. Visual and audible alarm required to work.
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Lifesaving › Lifefloat › Float-free Link
Issued 2 June 2014 Resolved
Provide proper size float-free link for lifefloat. Vessel route restricted to 4 passengers on coastwise and ocean route until provided.
Action required: 705 - Other - as specified
Resolved 2 June 2014
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 June 2014 Resolved
Provide 10 adult type I life jackets. Passenger count reduced by 10 until provided.
Action required: 705 - Other - as specified
Resolved 2 June 2014
Resolution: Jackets provided and onboard.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 June 2014 Resolved
Provide A II porttable fire extinguisher.
Condition: Improper/Lack of Maintenance
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 2 June 2014 Resolved
Provide operational HERTZ meter for switch board.
Due 13 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Fire Fighting › Fire Main › Pressure
Issued 2 June 2014 Resolved
Install proper psi gauge on both fixed fire pumps.
Due 13 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 June 2014 Resolved
Repair or replace smoke detector in steering compartment.
Due 6 June 2014
Resolved 13 June 2014
Resolution: Received email proof of sat repairs.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 June 2014 Resolved
Provide cover for elec outlet in Eng Room behind the ladder.
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 June 2014 Resolved
Post EAP phone number
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 June 2014 Resolved
Provide a D.A.P. policy for company/vessel.
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 2 June 2014 Resolved
Provide stbd mde J/W gauge at eng.
Due 13 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Documentation › Logs/Records › Logbook (official)
Issued 2 June 2014 Resolved
Provide Lifesaving log book.
Due 6 June 2014
Resolved 6 June 2014
Resolution: Received email proof of sat repairs.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 June 2012 Resolved
Provide proof of annual MIS submission.
Due 11 July 2012
Resolved 2 June 2014
Resolution: Provided.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 11 June 2012 Resolved
Provide means to complete post casualty alcohol testing within 2 hours of incident.
Due 11 July 2012
Resolved 19 June 2012
Resolution: Proof of purchase for saliva alcohol tests provided by operator.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 June 2012 Resolved
Provide proof of annual servicing for fixed fire extinguishing system in engine room.
Due 15 June 2012
Resolved 11 June 2012
Resolution: CO2 system inspected and tagged.
Construction/Loadline › Hull › Transverse Frame
Issued 9 April 2009 Resolved
Transverse frame in fuel room is detached/delaminated on starboard side at sideshell. Make permanent and proper repair to fiberglass at frame/hull intersection.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 1 May 2009
Resolution: Ground back 14" / polyester laminating resin used to connect replacement tabbing 1-1.2 oz mat/ 1-8" biax 3oz roving+1.5oz mat combo tape/ 1-3oz woven roving/ 1-1.5oz mat/ final coat gel coat installed after exam of laminating coats is white w/ wax.
Engineering › Steering Gear System › Rudder Stock
Issued 9 April 2009 Resolved
Port side rudder post stuffing box is cracked, make proper repair.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 1 May 2009
Resolution: Replaced in kind. Installation found sat. Require stbd rudder stock packing gland to be adjusted to stop excess leakage while aboard this visit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 April 2009 Resolved
Repair/weld railing at top of stairway, 2nd deck aft.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 1 May 2009
Resolution: completed.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 April 2008 Resolved
Provide valid Safety Radiotelephony certificate and station license.
Due 14 May 2008
Resolved 16 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 April 2008 Resolved
Repair malfunctioning visual bilge alarm
Due 14 May 2008
Resolved 30 April 2008
Lifesaving › Lifefloat › Painter
Issued 29 April 2008 Resolved
Attach painter and weak-link prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2009
Resolved 30 April 2009
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 29 April 2008 Resolved
Repair fuel leak on #1 injector on port generator.
Due 14 May 2008
Resolved 1 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 May 2006 Resolved
Prove FF and portables are serviced for their annual requirements
Due 8 May 2006
Resolved 8 May 2006
Communications › Radio Communications › EPIRB
Issued 8 May 2006 Resolved
Replace EPIRB antenna.
Due 12 May 2006
Resolved 15 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 8 May 2006 Resolved
Prove proper operation of prot side generator.
Due 16 May 2006
Resolved 15 May 2006
Fire Fighting › Fire Hoses › Material
Issued 27 April 2005 Resolved
Provide proof of fire main hoses approved IAW 46 CFR 181.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 5 May 2005
Resolution: Inspected hoses and nozzles on vessel under pressure on 06MAY05.
Fire Fighting › Nozzles › Type
Issued 27 April 2005 Resolved
Replace fire main nozzles IAW 46 CFR 181.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 5 May 2005
Resolution: Inspected hoses and nozzles on vessel under pressure on 06MAY05.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 19 August 2004 Resolved
Renew radio operators permit for principal master.
Due 19 September 2004
Resolved 26 August 2004
Resolution: Per faxed letter fm Captain clark, ltr in documents section of vessel details.
Engineering › Sea-water System (primary cooling) › Pump
Issued 19 August 2004 Resolved
Repair starboard main diesel engine raw water impeller.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2004
Resolution: Per faxed letter fm Captain clark, ltr in documents section of vessel details.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 August 2004 Resolved
Replace raw water hoses both main diesel engines.
Due 26 August 2004
Resolved 26 August 2004
Resolution: Per faxed letter fm Captain clark, ltr in documents section of vessel details.
Documentation › Markings/Placards › Warning Signs
Issued 19 August 2004 Resolved
Post upper deck passenger limit sign.
Due 19 September 2004
Resolved 26 August 2004
Resolution: Per faxed letter fm Captain clark, ltr in documents section of vessel details.
Documentation › Certificates/Documents
Issued 4 August 2003 Resolved
Provide stability letter. LEGACY COMPONENT DESC: Stability Letter
Due 19 August 2003
Resolved 6 August 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 4 August 2003 Resolved
provide correct bracket for portable extinguisher in pilot house. LEGACY COMPONENT DESC: Mounting Bracket
Due 4 September 2003
Resolved 11 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 August 2003 Resolved
Test fixed co2 pressure switch. LEGACY COMPONENT DESC: Operating Controls
Due 4 September 2003
Resolved 12 March 2004
Engineering › Bilge Water Management System
Issued 4 August 2003 Resolved
Repair bilge high level alarm indicators.
Due 4 September 2003
Resolved 11 March 2004
Resolution: Tested, all sat.
Deck/Cargo › Holds/Tanks
Issued 13 August 2002 Resolved
fuel tank vents missing flame screen. Repair/renew LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 25 September 2002
Resolution: Screen in place
Communications › Radio Communications
Issued 13 August 2002 Resolved
SSB inop. Provide proof SSB works. Vsl restricted to coastwise route. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 25 September 2002
Resolution: NEW SSB Installed an tested.
Documentation › Certificates/Documents
Issued 13 August 2002 Resolved
Safety Radio Certificate expired. Vsl restricted to 1000' from shore. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 25 September 2002
Resolution: Received copy of new cert.
Fire Fighting
Issued 28 August 2001 Resolved
REPLACE GALLEY FIRE EXTINGUISHER.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
REPAIR EPIRB AND REASSEMBLE.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
CONDUCT AND LOG MONTHLY EPIRB TESTS.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
DRAFT STATION BILL TO REFLECT THE VESSEL AND ITS CREW.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Navigation
Issued 28 August 2001 Resolved
TIGHTEN/REPAIR PORT RUDDER POST.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 28 August 2001 Resolved
REPLACE PLASTIC BILGE HOSES WIH REINFORCED HOSE.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 28 August 2001 Resolved
POST COI, STABILITY LETTER, FCC STATION LICENSE AND FCC RADIOTELEPHONY CERTIFICATES.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
ATTACH PADDLES TO LIFEFLOATS.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
REPLACE EYEWASH IN FIRST AID KIT.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 28 August 2001 Resolved
STENCIL LOCATION OF DISTRESS SIGNALS.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Engineering
Issued 2 March 2001 Resolved
Install 30X30 flame screen mesh for fuel oil vents, port and stbd.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
Install electrical cover plate for receptacle box in engine room located overhead on centerline iwo Port and stbd engines.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
Secure wiring throughout vessel with metal supports spaced not more than 24inches apart.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
Provide double clamps for bilge line flex hose in engine room IWO fwd end of port/stbd engines
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
Remove dead end wiring in engine room IWO centerline between port and stbd engines
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
Replace hand bilge pump hoses and provide adequate length to reach lower bilge space for forepeak.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Fire Fighting
Issued 2 March 2001 Resolved
Provide approved firefighting nozzles for port and stbd fire stations.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
Install GFCI outlet for stbd battery charger in engine room.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Documentation
Issued 22 May 2000 Resolved
SHOW COMPLIANCE WITH CG DRUG TESTING REGS.
Condition: Unknown
Due 22 May 2000
Resolved 30 May 2000
Lifesaving
Issued 22 May 2000 Resolved
REGISTER EPIRB. VESSEL RESTRICTED TO L, B, S, AND RIVERS UNTIL CLEARED.
Condition: Unknown
Due 29 May 2000
Resolved 30 May 2000
Electrical
Issued 2 March 1999 Resolved
FOREPEAKE: REMOVE DEAD ENDED CABLE OR PROVIDE JUNCTION BOX, AND CRIMP NUTSON CABLES. AFT SECTION OF OVERHEAD
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Electrical
Issued 2 March 1999 Resolved
ENGINE ROOM: REMOVE DEAD ENDED WIRES (3) TOTAL LOCATED ON TRANSVERSE BEAM AFT OF BOTH MDE (2-ONE BEHIND EACH ENGINE) AND (1-LOCATED ON LONG. BEAM JUST FORWARD OF TRANSVERSE BEAM), OR INSTALL JUNCTION BOXES WITH CRIMPED WIRE NUTS.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 2 March 1999 Resolved
ENGINE ROOM: PERMENANTLY AFFIX DOC NO#. TO MAIN BEAM. CURRENTLY AFFIXED WITH WOOD SCREWS, AND EASILY REMOVABLE.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 2 March 1999 Resolved
LAZ: ADJUST RETAINING BAND ON PORT SIDE EXHAUST (AFT HOSE CLAMP LOOSE, SOOT PRESENT AT INSPECTION)
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 2 March 1999 Resolved
MAIN DECK: INSTALL 30/30 MESH FLAME SCREEN TO BOTH FUEL OIL VENTS. NONE INSTALLED.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Construction/Loadline
Issued 2 March 1999 Resolved
ENGINE ROOM: PLUG HOLE (1") IN AFT BULKHEAD, PORT SIDE, BEHIND GENERATOR AT TOP OF BULKHEAD.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
ENGINE ROOM: PROVIDE RETAINING STRAP/CABLE FOR HOT WATER HEATER
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Construction/Loadline
Issued 2 March 1999 Resolved
LAZ: WIRE HIGH LEVEL ALARM SENSOR. SENSOR IS INSTALLED, BUT WIRES HAVE BEEN DISCONNECTED, OWNER COULD NOT INDICATE WHY, AND SAID THE NEW BILGE PUMP HAD ONLY A AUTO SWITCH INSTALLED, WITHOUT A SENSOR FOR HIGH LEVEL.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
FORWARD VOID MAIN CABIN: SECURE LADDER AT TOP AND BOTTOM, CURRENTLY ONLY ONE SCREW ON THE PORT SIDE TOP IS HOLDING LADDER IN PLACE
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 3 June 1997 Resolved
PROVIDE APPROVED FIRE DETECTION SYSTEM_x001C_ VESSEL NOT TO CARRY PASSENGERS UNTIL CORRECTED
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Lifesaving
Issued 3 June 1997 Resolved
POST STATION BILL IAW 46CFR 185.514
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Lifesaving
Issued 3 June 1997 Resolved
POST PFD DONNING PLACARD IAW 46 CFR 185.516
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Documentation
Issued 3 June 1997 Resolved
POST STABILITY LETTER
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997

Casualty record · 3

28 November 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3932898
27 May 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4707643
21 September 2024Routine · role: Involved in a Marine Casualty · at MEADOWBROOK STATE PARKWAY BRIDGE · activity 8011967
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.