Records from 2002 to 2026. Most recent: inspection, 18 February 2026.
Inspection history · 29
18 February 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8312095
9 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276501
22 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8116914
3 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8013736
22 April 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7899736
29 February 2024
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7861772
10 October 2023
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7807121
10 October 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7809518
3 August 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7841916
17 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7669992
17 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670505
20 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7581262
7 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7426790
3 February 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7404084
29 September 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333671
23 August 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7295674
18 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7200105
22 June 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992584
14 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953207
19 February 2020
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913184
27 November 2019
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6863022
13 May 2019
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6681309
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538981
23 July 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6519824
4 June 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434087
29 May 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6427611
6 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6167243
25 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5886404
14 April 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5836182
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 January 2026
Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers.
46CFR177.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2026
Resolution: Witness EGRESS and final installation. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2025
Resolved
Provide vessel with valid FCC station license certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2025
Resolution: Vessel provided valid cert.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025
Resolved
CO2 bottles and piping were found unsecured, provide bottles and piping with permanent fastening to remain secure in all sea conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Bottles and piping were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025
Resolved
Main engine raycor fuel bowls were found full of diesel fuel. Remove diesel fuel from flame impingement bowls.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Fuel was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025
Resolved
Engine room fuel day tank was found with non-fuel rated hose for sight glass. Make proper repairs with proper hose to prevent leakage of fuel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Valves were provided and fuel rated tubing was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2024
Resolved
Vessel life rafts were removed for inspection. Replace life-rafts and make available for follow on inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed new life rafts
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024
Resolved
07 Life Jacket lights inop. Vessel passenger count restricted by 7 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2024
Resolved 2 May 2024
Resolution: Replaced lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Aft ring buoy grab line deteriorated. Replace line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2024
Resolution: Replaced ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Floating light on top ring buoy found to be inop. Repair or replace light. If batteries are replaced provide batter manufacturer and model no. Vessel restricted to daytime operations until repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 May 2024
Resolution: Replaced battery in light.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
Engine room smoke detector found to be removed. Replace detector and provide for follow on inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed smoke detector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
Smoke detector in Galley space was not present. Install interconnected smoke detector to Galley space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed smoke detector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2023
Resolved
Port hand rail sustained damaged due to collision with rec-boat, Submit repair proposal and repair prior carriage of passenger.
Action required: 705 - Other - as specified
Resolved 23 October 2023
Resolution: Owner operator repaired damage rail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2023
Resolved
Port generator failed to start during inspection. Provide two sources for vital systems.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified port generator was operating successfully.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
Open wire found in Forepeak IWO port side aft floor. Terminate wire in Junction Box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified wire was terminated in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
Distribution panel in accommodation space found to have open access within the panel. Install blanks to eliminate electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified distro panel had installed blanks in preniously open spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
STBD generator found to have disconnected ground wire. Re-connect wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified STBD generator was properly grounded and extra loose groundign wire was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
The jacketing on the starboard genset power cable was compromised. Repair/replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 14 April 2022
Resolution: Corrected and witnessed by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
Both fuel tanks in the lazerette were not bonded. Install bonding wires to each fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 14 April 2022
Resolution: Corrected and witnessed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2021
Resolved
Fire main system's pressure gauge was found inoperable. Replace gauge and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep installed new gauge and provided photo.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
New shore power cable was installed without retaining fastener where it enters the power panel. Provide cable with vibration/chafe resistant fitting at power panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep provided photo of properly installed retaining fastener.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
Both generator's main cable feed was found to be backed-out of the clamp fitting where it enters the generator. Inspect cable conductors for chafe damage, and properly refasten both generator clamp fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep provided photos of both generator power cables with proper fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020
Resolved
Wire sheathing was split open on shore power cable in main engine room distribution box. Complete temporary repairs by taping with electrical tape immediately, and conduct permanent repair/replacement within 90 days.
Action required: 705 - Other - as specified
Due 4 November 2020
Resolved 18 May 2021
Resolution: Attended vessel for annual inspection, shore power cables were replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2020
Resolved
Vessel has unauthorized welding cable installed on the main breaker panel. Identify and remove all welding cable and replace with approved UL Boat or UL Marine cable of appropriate size to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2020
Resolved 6 August 2020
Resolution: Replaced with UL 2 AWG cable.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020
Resolved
STARBOARD SIDE FUEL OIL SHUTOFF VALVE WAS INOPERABLE AND RENDERED INCAPABLE OF SECURING FUEL OIL SUPPLY TO ENGINES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2020
Resolution: Shutoff valve operational
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020
Resolved
GALLEY INTERLOCKS THAT SECURE POWER TO GRIDDLE AND EXHAUST FAN WERE SKIPPED DURING ANNUAL INSPECTION. PROVE CORRECT INSTALLATION AND OPERATION OF INTERLOCKS PRIOR TO CONDUCTING GALLEY OPERATIONS.
Action required: 705 - Other - as specified
Resolved 8 June 2020
Resolution: all shutdowns verified operational
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2020
Resolved
ALL VESSELS CARRYING INFLATABLE SURVIVAL CRAFT MUST HAVE A PLACARD NEAR THE CRAFT CONTAINING LAUNCHING INSTRUCTIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2020
Resolution: placard mounted as required
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020
Resolved
Examine all accessible parts of the exterior & interior of the hull, the watertight bulkheads & weather deck. Vessel to remove/cut out to good wood & make permanent repairs to the area IWO portable water line thru bulkhead on the port side bottom of the fwd aft steering bulkhead. (to be completed cleared by San Diego Inspection)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2020
Resolved 18 May 2021
Resolution: Attended vessel for annual isnpection, new plywood bulkhead section was installed and painted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 November 2019
Resolved
Clean hydraulic oil from electrical cabinet behind helm in wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 7 February 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 November 2019
Resolved
Place emergency escape label above aft escape hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 7 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Label unmarked fuses in distribution panels throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 22 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessel's electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 11 February 2020
Resolved 6 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019
Resolved
Prove proper operation of the Mast head lamp prior to night time operations.
Action required: 705 - Other - as specified
Due 27 May 2019
Resolved 22 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Renew the life ring located on the aft blkhd of the pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Renew the life ring float light battery. Correct prior to night time operations.
Action required: 705 - Other - as specified
Resolved 22 May 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2019
Resolved
Prove proper operation of forepeak bilge high water audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2019
Resolved
Ensure engine room vent covers properly latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 22 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 July 2020
Resolution: Not in VIVS
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 June 2017
Resolved
Replace rescue ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 15 June 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 June 2017
Resolved
Replace worn handles on fuel manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 15 June 2017
Fire Fighting › Fire Pumps › Pressure
Issued 25 May 2016
Resolved
Provide F/P pressure gauge.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 24 June 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 May 2016
Resolved
Properly mount 2nd F/E in E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 24 June 2016
Documentation › Markings/Placards › Official Number (US)
Issued 25 May 2016
Resolved
Properly mark vessel name and hailing port on stern and name on port and starboard bow.
Action required: 705 - Other - as specified
Resolved 24 June 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2016
Resolved
Repair railing on both port and starboard top deck next to lifesaving equiptment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 25 May 2016
Resolution: Attended vessel and verified install of rail.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 April 2016
Resolved
Cap all cutoff flexible hoses in the engineroom.
Due 14 May 2016
Resolved 22 April 2016
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2016
Resolved
Repair leaking fuel oil manifold valves in the engine room.
Due 14 May 2016
Resolved 22 May 2016
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 14 April 2016
Resolved
Install lighting fixture covers on the mess deck.
Due 22 May 2016
Resolved 22 April 2016