ISLANDER

ISLANDER is a 1968 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in February 2026, along with 46 deficiencies and 6 casualty investigations between 2002 and 2023.

Records from 2002 to 2026. Most recent: inspection, 18 February 2026.

Built
1968
Last inspected
18 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 February 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ2261
Flag
UNITED STATES
Maury page id
psix-45761

Documentation record

Registered dimensions (L × B × D)79.7 ft × 23.3 ft × 6.5 ft
Registered tonnagegross 92 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
77 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

18 February 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8312095
9 December 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276501
22 April 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8116914
3 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8013736
22 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7899736
29 February 2024 Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7861772
10 October 2023 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7807121
10 October 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7809518
3 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7841916
17 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7669992
17 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670505
20 October 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7581262
7 April 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7426790
3 February 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7404084
29 September 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333671
23 August 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7295674
18 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7200105
22 June 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992584
14 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953207
19 February 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913184
27 November 2019 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6863022
13 May 2019 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6681309
12 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6538981
23 July 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6519824
4 June 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434087
29 May 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6427611
6 June 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6167243
25 May 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5886404
14 April 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5836182

Deficiency record · 46

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 January 2026 Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers. 46CFR177.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2026
Resolution: Witness EGRESS and final installation. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2025 Resolved
Provide vessel with valid FCC station license certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2025
Resolution: Vessel provided valid cert.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025 Resolved
CO2 bottles and piping were found unsecured, provide bottles and piping with permanent fastening to remain secure in all sea conditions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Bottles and piping were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025 Resolved
Main engine raycor fuel bowls were found full of diesel fuel. Remove diesel fuel from flame impingement bowls.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Fuel was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025 Resolved
Engine room fuel day tank was found with non-fuel rated hose for sight glass. Make proper repairs with proper hose to prevent leakage of fuel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Valves were provided and fuel rated tubing was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2024 Resolved
Vessel life rafts were removed for inspection. Replace life-rafts and make available for follow on inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed new life rafts
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
07 Life Jacket lights inop. Vessel passenger count restricted by 7 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2024
Resolved 2 May 2024
Resolution: Replaced lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024 Resolved
Aft ring buoy grab line deteriorated. Replace line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2024
Resolution: Replaced ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024 Resolved
Floating light on top ring buoy found to be inop. Repair or replace light. If batteries are replaced provide batter manufacturer and model no. Vessel restricted to daytime operations until repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 May 2024
Resolution: Replaced battery in light.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024 Resolved
Engine room smoke detector found to be removed. Replace detector and provide for follow on inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed smoke detector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024 Resolved
Smoke detector in Galley space was not present. Install interconnected smoke detector to Galley space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2024
Resolution: Installed smoke detector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2023 Resolved
Port hand rail sustained damaged due to collision with rec-boat, Submit repair proposal and repair prior carriage of passenger.
Action required: 705 - Other - as specified
Resolved 23 October 2023
Resolution: Owner operator repaired damage rail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2023 Resolved
Port generator failed to start during inspection. Provide two sources for vital systems.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified port generator was operating successfully.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Open wire found in Forepeak IWO port side aft floor. Terminate wire in Junction Box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified wire was terminated in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Distribution panel in accommodation space found to have open access within the panel. Install blanks to eliminate electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified distro panel had installed blanks in preniously open spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
STBD generator found to have disconnected ground wire. Re-connect wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 3 May 2023
Resolution: MI verified STBD generator was properly grounded and extra loose groundign wire was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022 Resolved
The jacketing on the starboard genset power cable was compromised. Repair/replace as necessary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 14 April 2022
Resolution: Corrected and witnessed by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022 Resolved
Both fuel tanks in the lazerette were not bonded. Install bonding wires to each fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 14 April 2022
Resolution: Corrected and witnessed by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2021 Resolved
Fire main system's pressure gauge was found inoperable. Replace gauge and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep installed new gauge and provided photo.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021 Resolved
New shore power cable was installed without retaining fastener where it enters the power panel. Provide cable with vibration/chafe resistant fitting at power panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep provided photo of properly installed retaining fastener.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021 Resolved
Both generator's main cable feed was found to be backed-out of the clamp fitting where it enters the generator. Inspect cable conductors for chafe damage, and properly refasten both generator clamp fittings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 4 June 2021
Resolution: Vessel rep provided photos of both generator power cables with proper fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020 Resolved
Wire sheathing was split open on shore power cable in main engine room distribution box. Complete temporary repairs by taping with electrical tape immediately, and conduct permanent repair/replacement within 90 days.
Action required: 705 - Other - as specified
Due 4 November 2020
Resolved 18 May 2021
Resolution: Attended vessel for annual inspection, shore power cables were replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2020 Resolved
Vessel has unauthorized welding cable installed on the main breaker panel. Identify and remove all welding cable and replace with approved UL Boat or UL Marine cable of appropriate size to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2020
Resolved 6 August 2020
Resolution: Replaced with UL 2 AWG cable.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020 Resolved
STARBOARD SIDE FUEL OIL SHUTOFF VALVE WAS INOPERABLE AND RENDERED INCAPABLE OF SECURING FUEL OIL SUPPLY TO ENGINES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2020
Resolution: Shutoff valve operational
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020 Resolved
GALLEY INTERLOCKS THAT SECURE POWER TO GRIDDLE AND EXHAUST FAN WERE SKIPPED DURING ANNUAL INSPECTION. PROVE CORRECT INSTALLATION AND OPERATION OF INTERLOCKS PRIOR TO CONDUCTING GALLEY OPERATIONS.
Action required: 705 - Other - as specified
Resolved 8 June 2020
Resolution: all shutdowns verified operational
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2020 Resolved
ALL VESSELS CARRYING INFLATABLE SURVIVAL CRAFT MUST HAVE A PLACARD NEAR THE CRAFT CONTAINING LAUNCHING INSTRUCTIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2020
Resolution: placard mounted as required
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020 Resolved
Examine all accessible parts of the exterior & interior of the hull, the watertight bulkheads & weather deck. Vessel to remove/cut out to good wood & make permanent repairs to the area IWO portable water line thru bulkhead on the port side bottom of the fwd aft steering bulkhead. (to be completed cleared by San Diego Inspection)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2020
Resolved 18 May 2021
Resolution: Attended vessel for annual isnpection, new plywood bulkhead section was installed and painted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 November 2019 Resolved
Clean hydraulic oil from electrical cabinet behind helm in wheel house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 7 February 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 November 2019 Resolved
Place emergency escape label above aft escape hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 7 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019 Resolved
Label unmarked fuses in distribution panels throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 22 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessel's electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 11 February 2020
Resolved 6 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019 Resolved
Prove proper operation of the Mast head lamp prior to night time operations.
Action required: 705 - Other - as specified
Due 27 May 2019
Resolved 22 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019 Resolved
Renew the life ring located on the aft blkhd of the pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019 Resolved
Renew the life ring float light battery. Correct prior to night time operations.
Action required: 705 - Other - as specified
Resolved 22 May 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2019 Resolved
Prove proper operation of forepeak bilge high water audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 23 May 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2019 Resolved
Ensure engine room vent covers properly latch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 22 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 July 2020
Resolution: Not in VIVS
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 June 2017 Resolved
Replace rescue ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 15 June 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 June 2017 Resolved
Replace worn handles on fuel manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 15 June 2017
Fire Fighting › Fire Pumps › Pressure
Issued 25 May 2016 Resolved
Provide F/P pressure gauge.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 24 June 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 May 2016 Resolved
Properly mount 2nd F/E in E/R.
Action required: 705 - Other - as specified
Due 25 June 2016
Resolved 24 June 2016
Documentation › Markings/Placards › Official Number (US)
Issued 25 May 2016 Resolved
Properly mark vessel name and hailing port on stern and name on port and starboard bow.
Action required: 705 - Other - as specified
Resolved 24 June 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2016 Resolved
Repair railing on both port and starboard top deck next to lifesaving equiptment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 25 May 2016
Resolution: Attended vessel and verified install of rail.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 April 2016 Resolved
Cap all cutoff flexible hoses in the engineroom.
Due 14 May 2016
Resolved 22 April 2016
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2016 Resolved
Repair leaking fuel oil manifold valves in the engine room.
Due 14 May 2016
Resolved 22 May 2016
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 14 April 2016 Resolved
Install lighting fixture covers on the mess deck.
Due 22 May 2016
Resolved 22 April 2016

Casualty record · 6

28 July 2002Routine · role: Involved in a Marine Casualty · activity 1653721
21 August 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2473367
28 October 2009Routine · role: Involved in a Marine Casualty · activity 3634456
23 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6519824
29 September 2021Routine · role: Involved in a Marine Casualty · 1 dead · activity 7333671
10 October 2023Routine · role: Involved in a Marine Casualty · activity 7809518
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.