← All vessels
ISLANDER
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Southwest District (CGD-SW) · Other hulls named ISLANDER
ISLANDER is a 1968 passenger vessel (inspected). The Coast Guard has recorded 112 inspections since 1984, most recently in February 2026, along with 172 deficiencies and 6 casualty investigations between 2002 and 2023.
Records from 1984 to 2026. Most recent: inspection, 18 February 2026.
- Built
- 1968
- Last inspected
- 18 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 112
- Deficiencies
- 172 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 6 investigations · 2002–2023
Identity
512505
WDQ2261
45761
Flag
UNITED STATES
368406170
Maury page id
psix-45761
Inspections, by type
…with no type recorded29
Years with a record
40 calendar years (1984–2026)
The 112 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)79.7 ft × 23.3 ft × 6.5 ft
Registered tonnagegross 92 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR & DONALDSON · COSTA MESA, CA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
77 - Regulatory (Subpart C or D), Net Ton
77 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ2261MMSI 368406170 · active · compulsorily equipped · granted 26 February 2025, expires 26 February 2035
WDC5160MMSI 367036830 · expired · compulsorily equipped · granted 29 April 2015, cancelled 31 May 2025
WAT2489MMSI not assigned · expired · compulsorily equipped · granted 23 October 1996, cancelled 17 March 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 112
18 February 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8312095
9 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276501
22 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8116914
3 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8013736
22 April 2024
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7899736
29 February 2024
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7861772
10 October 2023
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7807121
10 October 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7809518
3 August 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7841916
17 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7669992
17 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670505
20 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7581262
7 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7426790
3 February 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7404084
29 September 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333671
23 August 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7295674
18 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7200105
22 June 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6992584
14 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6953207
19 February 2020
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913184
27 November 2019
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6863022
13 May 2019
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6681309
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538981
23 July 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6519824
4 June 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6434087
29 May 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6427611
6 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6167243
25 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5886404
14 April 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5836182
28 March 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4824687
4 March 2014
COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4807872
11 May 2012
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4300327
8 February 2012
Construction Oversight · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4299149
5 December 2011
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4202325
19 January 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3666366
3 March 2009
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3412814
6 May 2008
Spot Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3201287
28 March 2008
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3167792
9 January 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3111802
13 March 2007
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2867857
17 March 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2572280
12 January 2006
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2559915
21 August 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2473367
7 July 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2424004
4 May 2005
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2324808
6 December 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2254308
22 March 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2029800
5 March 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2018846
13 February 2004
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2006343
6 February 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001809
2 December 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1957035
9 June 2003
Type not recorded
No type recorded · USCGC PETREL (WPB 87350) · USCG Southwest District (CGD-SW) · Activity 1890303
3 December 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713996
28 July 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1653721
28 July 2002
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1653877
23 January 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1480698
13 March 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1068819
15 December 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403010
1 June 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1104322
5 May 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372617
30 March 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 782797
4 March 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802936
12 January 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1471179
13 January 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368554
22 September 1997
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378157
21 September 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 23823
3 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 18878
17 April 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394710
17 December 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437191
29 January 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 881740
14 January 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 61177
18 December 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430117
29 November 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371227
12 October 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360291
5 January 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1171308
7 April 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354652
3 January 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851308
22 November 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840454
13 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833671
24 December 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1141701
25 November 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829639
15 April 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267078
27 November 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 939938
8 August 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 937775
5 June 1991
Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 934849
1 April 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 899883
5 March 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1230752
4 December 1990
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 899384
11 May 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237457
29 November 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 904062
28 November 1989
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 926994
12 April 1989
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887414
22 November 1988
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 892615
26 May 1988
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1196195
23 February 1988
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1331485
14 December 1987
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1008070
25 November 1987
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1333375
18 December 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339118
4 December 1986
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1019692
7 August 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 997028
3 July 1986
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985129
17 April 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990325
28 March 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985727
28 January 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995913
23 December 1985
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992350
8 November 1985
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995991
11 January 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976838
3 January 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 977655
17 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285409
30 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976029
23 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976357
9 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284317
Deficiency record · 172
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 January 2026
Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers.
46CFR177.500
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2025
Resolved
Provide vessel with valid FCC station license certificate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2025
Resolved
CO2 bottles and piping were found unsecured, provide bottles and piping with permanent fastening to remain secure in all sea conditions.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025
Resolved
Main engine raycor fuel bowls were found full of diesel fuel. Remove diesel fuel from flame impingement bowls.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 April 2025
Resolved
Engine room fuel day tank was found with non-fuel rated hose for sight glass. Make proper repairs with proper hose to prevent leakage of fuel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2024
Resolved
Vessel life rafts were removed for inspection. Replace life-rafts and make available for follow on inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024
Resolved
07 Life Jacket lights inop. Vessel passenger count restricted by 7 until replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Aft ring buoy grab line deteriorated. Replace line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2024
Resolved
Floating light on top ring buoy found to be inop. Repair or replace light. If batteries are replaced provide batter manufacturer and model no. Vessel restricted to daytime operations until repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
Engine room smoke detector found to be removed. Replace detector and provide for follow on inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 April 2024
Resolved
Smoke detector in Galley space was not present. Install interconnected smoke detector to Galley space.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2023
Resolved
Port hand rail sustained damaged due to collision with rec-boat, Submit repair proposal and repair prior carriage of passenger.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2023
Resolved
Port generator failed to start during inspection. Provide two sources for vital systems.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
Open wire found in Forepeak IWO port side aft floor. Terminate wire in Junction Box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
Distribution panel in accommodation space found to have open access within the panel. Install blanks to eliminate electrical hazard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023
Resolved
STBD generator found to have disconnected ground wire. Re-connect wire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
The jacketing on the starboard genset power cable was compromised. Repair/replace as necessary.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
Both fuel tanks in the lazerette were not bonded. Install bonding wires to each fuel tank.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 May 2021
Resolved
Fire main system's pressure gauge was found inoperable. Replace gauge and prove proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
New shore power cable was installed without retaining fastener where it enters the power panel. Provide cable with vibration/chafe resistant fitting at power panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2021
Resolved
Both generator's main cable feed was found to be backed-out of the clamp fitting where it enters the generator. Inspect cable conductors for chafe damage, and properly refasten both generator clamp fittings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2020
Resolved
Wire sheathing was split open on shore power cable in main engine room distribution box. Complete temporary repairs by taping with electrical tape immediately, and conduct permanent repair/replacement within 90 days.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2020
Resolved
Vessel has unauthorized welding cable installed on the main breaker panel. Identify and remove all welding cable and replace with approved UL Boat or UL Marine cable of appropriate size to the satisfaction of the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020
Resolved
STARBOARD SIDE FUEL OIL SHUTOFF VALVE WAS INOPERABLE AND RENDERED INCAPABLE OF SECURING FUEL OIL SUPPLY TO ENGINES.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020
Resolved
GALLEY INTERLOCKS THAT SECURE POWER TO GRIDDLE AND EXHAUST FAN WERE SKIPPED DURING ANNUAL INSPECTION. PROVE CORRECT INSTALLATION AND OPERATION OF INTERLOCKS PRIOR TO CONDUCTING GALLEY OPERATIONS.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2020
Resolved
ALL VESSELS CARRYING INFLATABLE SURVIVAL CRAFT MUST HAVE A PLACARD NEAR THE CRAFT CONTAINING LAUNCHING INSTRUCTIONS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020
Resolved
Examine all accessible parts of the exterior & interior of the hull, the watertight bulkheads & weather deck. Vessel to remove/cut out to good wood & make permanent repairs to the area IWO portable water line thru bulkhead on the port side bottom of the fwd aft steering bulkhead. (to be completed cleared by San Diego Inspection)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 November 2019
Resolved
Clean hydraulic oil from electrical cabinet behind helm in wheel house.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 November 2019
Resolved
Place emergency escape label above aft escape hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Label unmarked fuses in distribution panels throughout vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessel's electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019
Resolved
Prove proper operation of the Mast head lamp prior to night time operations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Renew the life ring located on the aft blkhd of the pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Renew the life ring float light battery. Correct prior to night time operations.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2019
Resolved
Prove proper operation of forepeak bilge high water audible alarm.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2019
Resolved
Ensure engine room vent covers properly latch.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 6 June 2017
Resolved
Replace rescue ladder.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 June 2017
Resolved
Replace worn handles on fuel manifold.
Fire Fighting › Fire Pumps › Pressure
Issued 25 May 2016
Resolved
Provide F/P pressure gauge.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 May 2016
Resolved
Properly mount 2nd F/E in E/R.
Documentation › Markings/Placards › Official Number (US)
Issued 25 May 2016
Resolved
Properly mark vessel name and hailing port on stern and name on port and starboard bow.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2016
Resolved
Repair railing on both port and starboard top deck next to lifesaving equiptment.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 April 2016
Resolved
Cap all cutoff flexible hoses in the engineroom.
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2016
Resolved
Repair leaking fuel oil manifold valves in the engine room.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 14 April 2016
Resolved
Install lighting fixture covers on the mess deck.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 March 2014
Resolved
Provide crew to prove emergency procedure proficiency.
Engineering › Fuel Oil Service System › Valve
Issued 4 March 2014
Resolved
Prove proper operation of STBD remote fuel shutoff valve.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 March 2014
Resolved
Provide panel blank for open hole in Galley distribution panel.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 March 2014
Resolved
Provide cover for light fixture over STBD Generator.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 4 March 2014
Resolved
Provide proper bonding from transom to port rudder.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 March 2014
Resolved
Provide Coast Pilot update.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 March 2014
Resolved
Provide current COD.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 4 March 2014
Resolved
Prove proper operation of the SSB radio.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 8 February 2012
Resolved
Engine control/monitoring board was not permanently installed and control system needed to be properly hung in way of helm pump shaft/mechanism.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 February 2012
Resolved
CO2 system due for servicing, bottle discharge heads and piping was loose, pneumatic shut down switches did not shut down engines as designed, Hydro dates of bottles need to be proven.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 February 2012
Resolved
Exhaust lagging was not in place and exhaust Pedro-hose needed double clamping.
Engineering › Fuel Oil Service System › Filter
Issued 8 February 2012
Resolved
Install drain caps on all Racor fuel oil strainers.
Stability › Incline Test › General
Issued 5 December 2011
Resolved
Issued 835 reducing passenger count to 28, pending submittion of vessels COC.
Lifesaving › Hand Flares › Quantity
Issued 3 March 2009
Resolved
Provide an additional (2) red hand flares.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009
Resolved
Ensure PFD stowage container (signage) reflects actual number of PFDs carried.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 March 2009
Resolved
Provide 2009 Tide Tables.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 3 March 2009
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 3 March 2009
Resolved
Prove proper operation of SSB radio w/DSC.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 May 2008
Resolved
Type III MSD valve not secured.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 1 April 2008
Resolved
Install emergency light at emergency exit location in fwd bunk room.
Lifesaving › Hand Flares › Quantity
Issued 1 April 2008
Resolved
Provide (1) additional red hand flare.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 March 2008
Resolved
Conduct fire/MOB drills in presence of CG inspector (drills not conducted or logged in past 6 months, same deficiency noted at previous inspection). Drills not conducted this date due to full vessel crew is not present. No passengers until corrected.
Lifesaving › Hand Flares › Expired
Issued 28 March 2008
Resolved
Provide (5) additional red hand flares, and (2) additional orange smoke signals.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 March 2008
Resolved
Provide SSB radio w/Digital Selective Callling (DSC) capability. Vessel restricted to not more than 100nm from shore.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 March 2008
Resolved
Provide line for ring buoy watelight and connect to ring buoy.
Communications › Radio Communications › EPIRB
Issued 28 March 2008
Resolved
Provide current NOAA EPIRB registration, vessel restricted to not more than 100nm from shore.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2008
Resolved
Remove expired medications from first aid kit(s).
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 March 2008
Resolved
Provide cover for electrical junction box in galley hood.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 28 March 2008
Resolved
Repair emergency lighting in accommodation spaces, no overnight passengers until corrected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 March 2008
Resolved
Label remote emergency fuel shut off valves for fuel tanks in Laz.
Fire Fighting › Fire Pumps › Pressure
Issued 28 March 2008
Resolved
Provide fire pump pressure gauge.
Construction/Loadline › Structures › Superstructure
Issued 9 January 2008
Resolved
Replace galley window on stbd side.
Construction/Loadline › Hull › Side Shell
Issued 9 January 2008
Resolved
Treat wood rot in engine room, stbd side bulkhead behind tank and below hatch.
Communications › Radio Communications › EPIRB
Issued 13 March 2007
Resolved
Replace EPIRB battery & hydro-static release (both expired).
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 March 2007
Resolved
Replace/repair in-operable emergency light IVO forward emergency escape exit in the forward passenger bunkroom.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 March 2007
Resolved
Provide proof of current crew enrollment in drug testing program.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 March 2006
Resolved
Provide updated Coast Guard Light List.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 March 2006
Resolved
Provide updated U. S. Coast Pilot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 March 2006
Resolved
Provide copy Tide and Current Tables.
Navigation › Piloting/Steering › Marine Charts
Issued 17 March 2006
Resolved
Provide updated charts.
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 March 2006
Resolved
Provide roster with names of vessels crew enrolled in program.
Lifesaving › Hand Flares › Expired
Issued 17 March 2006
Resolved
Provide 1 red flare and 1 orange smoke. Vessel has 5 of each, required to have 6. Six (6) flares are past their expiration date; remove or store separately from the good flares.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 12 January 2006
Resolved
Repair/replace thru-hull valve for the port main engine.
Fire Fighting › Grease Extraction Hood › General
Issued 20 May 2005
Resolved
Provide fixed fire extinguishing system iaw 181.425 for grease extraction hood. Arrange for installation prior to carrying passengers and final installation with 30 days.
Documentation › Logs/Records › Logbook (official)
Issued 4 May 2005
Resolved
Ensure monthly EPIRB tests and quarterly drills are logged.
Personnel › Training › Fire Fighting Basic
Issued 4 May 2005
Resolved
Provide man over board training and prepare crew in two weeks to perform proper drills.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 May 2005
Resolved
Remove splice on line to waterlight and replace with quick disconnect clip.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 4 May 2005
Resolved
Label new breaker panel and fill dead space in old breaker panel.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 May 2005
Resolved
Procure and place exhaust lagging on all metal up to area being water cooled.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 4 May 2005
Resolved
Provide metal ladder for rescue platform
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 13 February 2004
Resolved
Provide servicing for all portable fire extinguishers. LEGACY COMPONENT DESC: Service
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 13 February 2004
Resolved
Provide servicing for fixed fire fighting system.
Fire Fighting › Fixed Fire Detection System
Issued 13 February 2004
Resolved
Provide smoke detectors in each accomodation space. LEGACY COMPONENT DESC: Smoke Detectors
Communications › Audible Communications
Issued 13 February 2004
Resolved
Provide additional speakers in foreward and aft overnight accomodation spaces.
Lifesaving › Buoyant Apparatus
Issued 13 February 2004
Resolved
Renew Sea Painter on vessels life floats
Lifesaving › Lifebuoys
Issued 13 February 2004
Resolved
Renew wasted lifeline on aft ring buoy LEGACY COMPONENT DESC: Buoyant Lifeline
Stability › Watertight Integrity
Issued 13 February 2004
Resolved
Provide proper piping penetrations where PVC piping penetrates the watertight bulkheads.
Engineering
Issued 13 February 2004
Resolved
Properly mount salt water pump for foreward bait tank. LEGACY COMPONENT DESC: Bait tank salt water pump
Electrical › Electrical Distribution System (service)
Issued 13 February 2004
Resolved
Prperly wire thermostat in foreward port berthing space LEGACY COMPONENT DESC: Wiring
Communications › Radio Communications
Issued 13 February 2004
Resolved
Prove proper operation of and crew familiarity with the SAT Phone, both Single Side Band Radios, and the NAVTEX Receiver.
Electrical › Electrical Distribution System (service)
Issued 13 February 2004
Resolved
Properly mark all breaker panels. LEGACY COMPONENT DESC: Distribution Panel Bus
Electrical › Electric Generation Source (service)
Issued 13 February 2004
Resolved
Clean oil and debris from port generator windings. LEGACY COMPONENT DESC: Generator
Fire Fighting › Fire Hoses
Issued 12 December 2002
Resolved
Renew (1) fire hose. Hose must meet 46 CFR 181.320(b). LEGACY COMPONENT DESC: Condition
Fire Fighting › Fire Pumps
Issued 12 December 2002
Resolved
Fire pump missing pressure gauge.
Documentation › Manuals/Policy Documentation
Issued 12 December 2002
Resolved
Provide Station Bill as per 46 CFR 185.514. LEGACY COMPONENT DESC: Emergency Instructions
Electrical › Electric Generation Source (service)
Issued 28 July 2002
Resolved
Make repairs to starboard generator to the satisfaction of the attending Coast Guard Marine Inspector prior to the carriage of passengers for hire. LEGACY COMPONENT DESC: Generator
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 July 2002
Resolved
Provide proper count portaqble fire ext. IAW COI. LEGACY COMPONENT DESC: Number
Engineering
Issued 13 January 1998
Resolved
Before use the forward starboard fuel tank must be hydroed in the presance of a Coast Guard inspector. If the owner does not have the tank hydroed brfore their next dry dock he must provide plans for the tanks renew.
Construction/Loadline
Issued 22 September 1997
Resolved
Make proper repair of starboard transom damage to the satisfaction of cattending CG Marine Inspector prior to operating vessel with passenger on board.
Accommodation/Occupational Safety
Issued 17 December 1996
Resolved
Restencil forward emergency escape hatch._x001C_
Electrical
Issued 17 December 1996
Resolved
Provide emergency lighting in forward passage way._x001C_ _x001C_
Accommodation/Occupational Safety
Issued 17 December 1996
Resolved
Provide adequate means of escape for aft emergency escape hatch._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 18 December 1995
Resolved
Repair port and starboard emergency fuel shut off valves on aft fuel tanks.
Navigation
Issued 18 December 1995
Resolved
Provide updated chart of San Pedro Harbor
Construction/Loadline
Issued 12 October 1995
Resolved
COMPLETE DRYDOCK INSPECTION PRIOR TO 01 DEC 95.
Electrical
Issued 5 January 1995
Resolved
PROVIDE INSULANT FOR WIRING OVER STARBOARD ENGINE.
Construction/Loadline
Issued 5 January 1995
Resolved
CLEAN AND TREAT OR SCARF AND RENEW ROT ON UNDERSIDE OF MAIN DECK IN THE FOREPEAK AS NEEDED.
Accommodation/Occupational Safety
Issued 22 November 1993
Resolved
PROVIDE SUITABLE LOCKING DEVICES FOR MSD OVERBOARD DISCHARGE VALVES.
Electrical
Issued 22 November 1993
Resolved
PROVIDE FAN SCREENS FOR GALLEY FANS AND AFT LAZARETTE VENT FAN.
Engineering
Issued 22 November 1993
Resolved
REPLACE CABLE PORT MIDSHIP FUEL SHUTOFF VALVE. TANK VALVE TO BE SHUT MANUALLY AND TANK NOT USED UNTIL REPAIRED.
Electrical
Issued 22 November 1993
Resolved
REPLACE BULB AFT EMERGENCY LIGHT.
Electrical
Issued 22 November 1993
Resolved
PROVIDE METALLIC WIRE HANGERS IAW IEEE #45 IN ENGINE ROOM
Lifesaving
Issued 22 November 1993
Resolved
PROVIDE PROPER LABEL FOR STBD BENCH PFD STORAGE.
Navigation
Issued 22 November 1993
Resolved
PROVIDE OPERATIONAL STERN LIGHT. VESSEL LIMITED TO DAYLIGHT OPERATIONS UNTIL REPAIRED.
Navigation
Issued 25 November 1992
Resolved
PROVIDE CHARTS AND PUBS IN ACCORDANCE WITH MEMO FROM [name withheld] OF USCG MSO LA/LB AND DATED 01JUN92.
Accommodation/Occupational Safety
Issued 25 November 1992
Resolved
RELABEL FORWARD AND AFT EMERGENCY ESCAPE HATCHES FROM BERTHING AREAS.
Engineering
Issued 25 November 1992
Resolved
RELABEL PORT AND STARBOARD AFT, AND PORT FORWARD FUEL OIL SHUT OFF VALVES.
Engineering
Issued 25 November 1992
Resolved
INSTALL PROPER FUEL SIGHT GLASS FOR FORWARD FUEL OIL DAY TANK.
Engineering
Issued 25 November 1992
Resolved
REPLACE ALL STARBOARD FUEL TANK VENT SCREENS.
Electrical
Issued 27 November 1991
Resolved
RE-LABEL THE BREAKER SWITCHES IN THE BREAKER PANEL, STBD SIDE OF THE PILOT HOUSE.
Documentation
Issued 27 November 1991
Resolved
POST THE STABLILITY LETTER ON THE BRIDGE.
Navigation
Issued 27 November 1991
Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES AND CURRENTLY CORRECTED CHARTS.
Engineering
Issued 27 November 1991
Resolved
LABEL EMERGENCY F/O SHUTOFFS, PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving
Issued 27 November 1991
Resolved
PROVIDE AND PROPERLY STOW THE 2 INFLATABLE LIFERAFTS. VESSEL OPERATIONS ARE LIMITED TO LIMITED COASTWISE AND CARRIAGE OF NO MORE THAN 95 PASSENGERS, 100 PERSONS TOTAL UNTIL THIS REQUIREMENT IS MET TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Electrical
Issued 27 November 1991
Resolved
RE-CONNECT OR REMOVE THE DEAD END WIRES UNDER THE ALARM PANEL IN THE PILOT HOUSE.
Fire Fighting
Issued 27 November 1991
Resolved
PERMANENTLY MARK THE FIRE AX WITH THE VESSEL'S NAME AND LABEL THE AX STOWAGE PRIOR TO CARRIAGE OF PASSENGERS.
Electrical
Issued 27 November 1991
Resolved
PROVE PROPER OPERATION OF THE STBD ENGINE RPM GAUGE LIGHT.
Navigation
Issued 8 August 1991
Resolved
VESSEL IS LIMITED TO OPERATING NO MORE THAN 60 MILES FROM THE BASELINE UNTIL THE VESSEL IS PROVIDED WITH A 406MHZ EPIRB, A NAVTEX RECEIVER, AND EMERGENCY SIGNAL GENERATOR AND RECEIVER, AND PARTICIPATES IN AMVER.
Navigation
Issued 28 November 1989
Resolved
PROVIDE NAVIGATION RULES PUBLICATION.
Engineering
Issued 28 November 1989
Resolved
REPAIR INOPERABLE EMERGENCY/REMOTE FUEL OIL SHUT-OFF TO STARBOARD FUEL OIL TANK.
Lifesaving
Issued 28 November 1989
Resolved
REPLACE RING LIFE BUOY LINES WITH A 3/8" SIZE, 60 FT LONG LINE.
Lifesaving
Issued 28 November 1989
Resolved
INSTALL TWO(2) 20-MAN INFLATABLE LIFERAFTS ON BOARD THE VESSEL PRIOR TO PLACING VESSEL IN OPERATION.
Navigation
Issued 28 November 1989
Resolved
PROVIDE THREE(3) BLACK BALL DAY SHAPES.
Engineering
Issued 25 November 1987
Resolved
INSTALL GUARD TO DRIVE COUPLINGS ON BILGE PUMPS PRIOR TO PLACING VESSEL IN OPERATION.
Engineering
Issued 25 November 1987
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF MAIN PROPULSION, MAIN STEERING, PILOTHOUSE CONTROLS, AND AUXILIARY EQUIPMENT PRIOR TO PLACING VESSEL IN OPERATION.
Lifesaving
Issued 25 November 1987
Resolved
SERVICE THE TWO(2) 20 MAN INFLATABLE LIFERAFTS PRIOR TO PLACING IN OPERATION.
Unknown
Issued 25 November 1987
Resolved
REPLACE OUTDATED BATTERY ON EPIRB PRIOR TO PLACING VESSEL IN OPERATION.
Lifesaving
Issued 25 November 1987
Resolved
REPLACE WASTED/WEAK LINES ON LIFEFLOATS PRIOR TO PLACING IN OPERATION.
Accommodation/Occupational Safety
Issued 17 April 1986
Resolved
INSTALL VALVES ON BOTH SIDES OF BULKHEAD ON PVC PIPING PENETRATION AT AFT BULKHEAD OF FORWARD BERTHING SPACE
Construction/Loadline
Issued 17 April 1986
Resolved
CLEAN ALL VALVE SEATS ON SEA VALVES
Documentation
Issued 17 April 1986
Resolved
MAKE VESSEL READY FOR INSPECTION FOR CERTIFICATION
Documentation
Issued 17 April 1986
Resolved
MAKE VESSEL READY FOR INTERNAL INSPECTION BY MARINE INSPECTOR
Engineering
Issued 28 March 1986
Resolved
THIS VESSELS CERTIFICATE OF INSPECTION IS REVOKED UNTIL SUCH TIME THAT APPLICATION FOR INSPECTION IS MADE, AND INSPECTION FOR CERTIFICATION IS COMPLETED.
Construction/Loadline
Issued 8 November 1985
Resolved
DURING NEXT AVAILABLE DDX MAKE REPAIRS TO EXCESSIVE DRYROTTED SUPPORT BEAMS ABOVE GENERATORS, SCRAPE AND TREAT ENTIRE ENGINEROOM FOR DRYROT.
Engineering
Issued 30 November 1984
Resolved
MAKE PERMANENT REPAIRS TO THE PORT POWER BILGE PUMP.
Lifesaving
Issued 23 November 1984
Resolved
INSTALL WATERLIGHTS ON THE BOUYANT APPARATUS.
Engineering
Issued 9 November 1984
Resolved
REPAIR/REPLACE THE STARBOARD POWER BILGE PUMP.
Lifesaving
Issued 9 November 1984
Resolved
PROPERLY STENCIL ALL LIFE JACKET STOWAGE LOCKERS.
Engineering
Issued 9 November 1984
Resolved
PROPERLY LABEL THE BILGE MANIFOLD.
Engineering
Issued 9 November 1984
Resolved
INSTALL 30 X 30 MESH FLAME SCREENS IN THE FUEL OIL VENTS.
Electrical
Issued 9 November 1984
Resolved
REPAIR THE STARBOARD GENERATOR.
Accommodation/Occupational Safety
Issued 9 November 1984
Resolved
REPAIR THE POWER VENTILATION FOR THE STARBOARD SIDE OF THE ENGINEROOM.
Electrical
Issued 9 November 1984
Resolved
PROVIDE A WEATHER PROOF COVER FOR THE BATTERY CHARGER BOX.
Engineering
Issued 9 November 1984
Resolved
INSTALL FLAME SHIELDS ON THE RACOR FUEL FILTERS.
Lifesaving
Issued 9 November 1984
Resolved
PROVIDE SUITABLE MOUNTING BRACKETS FOR THE BOUYANT APPARATUS WATERLIGHTS.
Casualty record · 6
28 July 2002Routine · role: Involved in a Marine Casualty · activity 1653721
21 August 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2473367
28 October 2009Routine · role: Involved in a Marine Casualty · activity 3634456
23 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6519824
29 September 2021Routine · role: Involved in a Marine Casualty · 1 dead · activity 7333671
10 October 2023Routine · role: Involved in a Marine Casualty · activity 7809518
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.