← All vessels
FRIO GALICIA
Freight Ship · Refrigerated Cargo Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named FRIO GALICIA
FRIO GALICIA is a 1997 freight ship. The Coast Guard has recorded 39 inspections since 1998, most recently in February 2025, along with 19 deficiencies and 4 operational controls.
Records from 1998 to 2025. Most recent: inspection, 20 February 2025.
- Built
- 1997
- Last inspected
- 20 February 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9143752 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
FPV3
457659
Flag
PANAMA
—
Maury page id
psix-457659
Inspections, by type
…with no type recorded14
Years with a record
19 calendar years (1998–2025)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it8917 - Convention (Subpart B), Gross Ton
5525 - Convention (Subpart B), Net Ton
12101 - Dead Weight, Ton
17281 - Displacement, Ton
5525 - Convention (Subpart B), Net Ton
12101 - Dead Weight, Ton
17281 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
20 February 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8081842
3 January 2025
Deficiency Check · PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8057048
26 April 2023
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7676260
9 March 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7648088
26 January 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7385801
24 September 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COE-Dockside · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6814768
26 June 2018
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6452520
4 January 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6065623
9 July 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5934742
7 July 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5925998
7 July 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5937004
3 February 2011
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3938299
2 February 2011
ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3936698
2 February 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3938123
31 January 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3936884
11 August 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3295607
28 July 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3276679
14 July 2007
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 2997043
29 June 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2977921
29 June 2007
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2977934
13 April 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2623689
3 January 2006
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2559681
28 July 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2443097
7 March 2005
PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2305312
12 January 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2274687
5 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2157549
3 August 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2155499
24 February 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2013569
24 November 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1953191
11 February 2003
Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1742756
1 August 2002
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1655226
22 January 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1480185
8 January 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1476610
3 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288721
9 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 285836
13 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273546
6 January 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424351
24 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 413067
23 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 72376
Deficiency record · 19
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 January 2025
Resolved
The life raft painter system shall provide a connection between the ship and the life raft and shall be so arranged as to ensure that the life raft when released and, in the case of an inflatable life raft, inflated is not dragged under by the sinking ship. PSCO observed life raft painter was attached to the ship instead of the weak link in the float free arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 January 2025
Resolved
Cargo ship survival craft embarkation arrangements shall be so designed that lifeboats can be boarded and launched directly from the stowed position and davit-launched liferafts can be boarded and launched from a position immediately adjacent to the stowed position or from a position to which the liferaft is transferred prior to launching in compliance with the requirements of regulation 13.5. PSCO observed a seized davit, rendering lifeboat unable to be launched.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 March 2023
Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the present regulations to ensure that the ship in all respcts will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed steam leaking from the steam delivery line and from the water supply line of the boiler. 74SOLAS(04)I/11(a)
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 March 2023
Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the present regulations to ensure that the ship in all respcts will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed unauthorized repairs on the sea water cooling pipe, main engine sea water cooling overboard pipe, and on the sewage pipe.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 March 2023
Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the present regulations to ensure that the ship in all respcts will remain fit to proceed to sea without danger to the ship or persons on board. 74SOLAS(04)1/11(a) PSCO observed a hole on the top of the sewage tank.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 24 September 2019
Resolved
Fire fighter’s outfits shall comply with the FSS Code. Personal equipment shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns. Fire fighter’s outfit hood was delaminating. 74SOLAS(04)II-2/10.1; FSS Code Ch.3/2.1.1.1; 17c
Fire Fighting › Fire Pumps › Pressure
Issued 26 June 2018
Resolved
0740-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump failed to provide sufficient water pressure initially. The coolant system on the pump was malfunctioning. 74SOLAS(2014)II-2/14.2.1.2 17ac
Engineering › Fuel Oil Service System › Piping
Issued 26 June 2018
Resolved
0750 – All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of collecting leakages and sounding an alarm for fuel line failure. Double jacketed fuel lines did not drain to collection point due to leak and could not sound alarm 74SOLAS(01)II-2/15.2.9 17ac
Engineering › Fuel Oil Service System › Piping
Issued 26 June 2018
Resolved
0750 – Oil fuel pipes and their valves and fittings shall be of steel or other approved material. Stuffing box drain lines on main engine are not constructed of steel or other approved material 74SOLAS(97) II-2/15.2.8 17ac
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 26 June 2018
Resolved
1499 - Boilers piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. An excessive amount of temporary repairs were found on the boiler 74SOLAS(04)II-1/26.1 17ac
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 June 2018
Resolved
0750 - Where A-Class divisions are penetrated for the passage of electrical cables arrangement shall be made to ensure that fire resistance is not impaired. A-class boundary in E-gen space was compromised due to improper wire installation 74SOLAS(97)II-2/18.1.1 17ac
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 26 June 2018
Resolved
0735 - The fire-fighter’s outfits or sets of personal equipment shall be kept ready for use in an easily accessible location. The chemical suits could not be easily accessed due to excessive dunnage (cardboard boxes) 74SOLAS(14)II-2/19.3.6.1 10c
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 7 July 2016
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order. The remote control wire on the starboard side lifeboat got stuck, causing the cable to break, and bend it's support beam. Solas 97 Ch. III/Reg. 19.2
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 28 July 2008
Resolved
Code 0735//Fire suits in unserviceable condition. Replace Fire Suits//Cite SOLAS 74 2004 ed. Chpt II-2 Reg 10/10.1 FSS Chpt 3 2.1.1//Action taken 17c
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 July 2008
Resolved
Vessel has inoperable secondary marine x-band radar.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 13 April 2006
Resolved
Lifesaving › Lifeboat
Issued 11 February 2003
Resolved
Motors for port and starboard lifeboats are both inoperable due to the cold weather. Solas 74/78, Ch. III, Reg 41, 6.2. Correct prior to departure from port. LEGACY COMPONENT DESC: Propulsion Engine
Lifesaving › Launching Appliances
Issued 8 January 2002
Resolved
While inspecting the releasing mechanism for the port lifeboat, the "guide arm " for the internal lowering mechanism was mis-aligned and caused stress on the cable connected to the brake. LEGACY COMPONENT DESC: Davit
Fire Fighting
Issued 9 January 2001
Resolved
Vessel must replace both fireman's outfits on board the vessel prior to next US port. 74 SOLAS amended II-2/17.1.1_x001C_ Both suits have excessive wear and the heat reflective covering is coming off.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.