MAURY USCG vessel records Sign in
← All vessels

BUCCANEER QUEEN

BUCCANEER QUEEN is a 1968 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 1985, most recently in August 2001, along with 78 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 6 August 2001.

Built
1968
Last inspected
6 August 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSB3527
Flag
UNITED STATES
—
Maury page id
psix-45768

Inspections, by type

…with no type recorded7
Years with a record 17 calendar years (1985–2001)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WSB3527MMSI not assigned · expired · compulsorily equipped · granted 29 January 1996, cancelled 1 April 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

6 August 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428083
6 July 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361555
1 September 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378788
4 August 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1113023
5 May 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378696
28 April 1998 COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383858
22 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398663
27 September 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402324
18 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374578
29 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 865970
29 March 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353717
17 November 1994 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429970
15 April 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370830
16 March 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1165035
14 April 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144841
23 March 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 837043
11 March 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145045
27 November 1992 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828247
9 April 1992 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1263275
20 March 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1010880
30 May 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910340
14 May 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213977
19 March 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 930263
19 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997311
20 March 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241060
10 October 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031239
15 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200778
17 March 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1040988
19 September 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1044814
4 May 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037425
25 March 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297914
17 March 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293299
31 March 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1327528
25 March 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1018808
30 July 1986 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 988165
30 June 1986 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1001439
18 March 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304823
27 September 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301511
8 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289363
29 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 980273

Deficiency record · 78

Fire Fighting
Issued 4 August 1999 Resolved
Schedule an inspection of the new heat detector system for the engine compartments upon installation of system. System is to be installed IAW approved plans dated 04 AUG 99.
Condition: Unknown
Due 4 August 1999
Resolved 4 August 1999
Fire Fighting
Issued 5 May 1999 Resolved
Contact marine inspection office to arrange for approval of existing fire fighting system.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Engineering
Issued 5 May 1999 Resolved
Provide new 30x30 mesh screen over starboard fuel tank vent.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Fire Fighting
Issued 5 May 1999 Resolved
PROVIDE ELECTRCAL PLAN FOR THE INSTALLATION OF NEW HEAT DETECTORS IN ENGINECOMPARTMENTS. (NO COAST GUARD APPROVAL OF HEAT DETECTOR OK. SEE MOC POLICY LETTER 4-96. UNLESS PLANS ARE NOT APPROVED, INSTALLATION INSPECTION COMPLETE.)
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Fire Fighting
Issued 5 May 1999 Resolved
Provide adequate means to secure engine compartment vents in case of a fire.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Navigation
Issued 5 May 1999 Resolved
Provide updated charts of operating area.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999 Resolved
Provide or update light list for 1999.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999 Resolved
Provide emergency broadcast placard
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999 Resolved
Provide deviation table for magnetic compass.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999 Resolved
Apply retro tape to both sides of buoyant apparatus.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999 Resolved
Put new batteries in both buoyant apparatus water lights.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999 Resolved
Ensure weak link is properly arranged so that it will be in tension after painter pays out.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999 Resolved
Paint distress signal box orange.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Documentation
Issued 5 May 1999 Resolved
Ensure an employee assistance program (EAP) is administered for the crew.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Construction/Loadline
Issued 27 September 1996 Resolved
Clean and treat dryrot in electrical compartment stbd side and on port sidearound exhaust discharge area.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Construction/Loadline
Issued 27 September 1996 Resolved
Clean and treat dryrot in way of middle bilge near packing gland coupling.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Construction/Loadline
Issued 27 September 1996 Resolved
Remove FRP from area around previous repair stbd aft quarter. Make available for MI to inspect wood for structural integrity.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 27 September 1996 Resolved
Make vessel available to Marine Inspector for underway check ride prior to carrying passengers for hire.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Accommodation/Occupational Safety
Issued 16 March 1994 Resolved
MOUNT CHARCOAL GRILL OUTBOARD OF RAIL OR REMOVE IT FROM THE VESSEL.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Engineering
Issued 16 March 1994 Resolved
GET VESSEL UNDERWAY IN A SEAWAY. PROVE PROPER OPERATION OF SAILS, RIGGING,ENGINES, AND STEERING GEAR. MAKE ENGINES AND STEERING GEAR READY FOR INSPECTION WHILE OPERATING.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Lifesaving
Issued 16 March 1994 Resolved
CONDUCT EMERGENCY DRILLS UNDERWAY.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
INSTALL POWER BILGE PUMP AND PIPING IN ACCORDANCE WITH 46 CFR 182.25.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Navigation
Issued 16 March 1994 Resolved
UPDATE LIGHT LIST, COAST PILOT, AND CHART.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Accommodation/Occupational Safety
Issued 16 March 1994 Resolved
REPLACE 1ST AND 3RD PORTHOLE WINDOWS FROM STERN ON PORT SIDE.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 16 March 1994 Resolved
RE-ATTACH BACKSTAY CHAIN PLATE ON STARBOARD TRANSOM.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Documentation
Issued 16 March 1994 Resolved
PROVIDE ON BOARD THE SIGNED ORIGINAL OF THE CERTIFICATE OF INSPECTION. _x001C_ _x001C_ (ATTENDING MARINE INSPECTOR WILL NEED TO ENDORSE ORIGINAL WHEN PROVIDED.)
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994 Resolved
RE-ATTACH GROUNDING STRAP IN AFT PORT BILGE.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994 Resolved
RENEW BATTERIES IN LANTERNS FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994 Resolved
REPLACE WING NUTS ON BATTERY FOR ELECTRONIC EQUIPMENT WITH PERMANENT-TYPE CONNECTORS.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Navigation
Issued 23 March 1993 Resolved
PROVIDE UP TO DATE LIGHT LIST, COAST PILOT, TIDE TABLES, AND UP TO DATE OR CORRECTED CHART.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Navigation
Issued 23 March 1993 Resolved
PREPARE A DEVIATION TABLE OR PROVIDE ANOTHER MEANS OF NAVIGATING.
Condition: Unknown
Due 16 April 1993
Resolved 29 March 1993
Lifesaving
Issued 23 March 1993 Resolved
STENCIL NUMBER OF LIFEJACKETS STORED IN EACH STORAGE AREA.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Accommodation/Occupational Safety
Issued 23 March 1993 Resolved
PROPERLY REPAIR 5TH PORT HOLE FROM THE BOW ON THE STARBOARD SIDE.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Lifesaving
Issued 23 March 1993 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Documentation
Issued 23 March 1993 Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Unknown
Issued 23 March 1993 Resolved
PROVIDE DOCUMENTATION OF THE VESSEL'S DRUG TESTING PROGRAM THAT DEMONSTRATES COMPLIANCE WITH 46 CFR 16, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 20 March 1992 Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS UNDERWAY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Construction/Loadline
Issued 10 October 1989 Resolved
COMPLETELY REPLACE ALL 4 VERTICAL STRUCTURAL MEMBERS ANCHORING BOWSPRIT IN FOREPEAK.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Construction/Loadline
Issued 10 October 1989 Resolved
PROPERLY PATCH BROKEN/CRACKED WOOD AND RE-APPLY FIBERGLASS TO DAMAGED AREA ON PORT BOW NEAR WATERLINE.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Engineering
Issued 17 March 1989 Resolved
REPAIR #1 MDE THRUST BEARING.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989 Resolved
REPLACE CABLE CLAMPS FOR MIZZEN TOPMAST STAY CABLE AT THE MIZZEN TOPMAST.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989 Resolved
REPLACE 7 ADULT AND 2 CHILD-SIZED PFD'S.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989 Resolved
PROVIDE 6 ORANGE HAND-HELD FLARES.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Fire Fighting
Issued 17 March 1989 Resolved
PROVIDE 20 FT OF DISCHARGE AND 10 FT OF SUCTION HOSE FOR THE HAND-HELD PORTABLE FIRE PUMP.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989 Resolved
REPLACE PORTSIDE BUOYANT APPARATUS WATERLIGHT BATTERY.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989 Resolved
PROPERLY REPAIR TERMITE DAMAGE TO THE MAINMAST SECOND TIER (MAIN TOPMAST) AND ALL ATTACHMENTS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989 Resolved
PROPERLY SECURE UPPER BOLT TO MIZZENMAST, FWD STAY, CHAIN PLATE, STARBOARD SIDE.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Accommodation/Occupational Safety
Issued 17 March 1989 Resolved
REPAIR BROKEN FOOTINGS FOR SECOND TIER RATLINES, MIZZENMAST.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Engineering
Issued 17 March 1989 Resolved
REPAIR LEAKING PACKING GLANDS FOR BOTH SHAFTS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 17 March 1989 Resolved
REPAIR LEAK AT RUDDER POST FOUNDATION.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 19 September 1988 Resolved
MAKE PERMANENT REPAIRS TO STEERING GEAR PRIOR TO OPERATING.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Navigation
Issued 19 September 1988 Resolved
INSTALL RUDDER STOPS AT VESSEL'S NEXT DRYDOCKING BUT NO LATER THAN 30 SEPTEMBER 1989.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Construction/Loadline
Issued 25 March 1988 Resolved
PROVIDE CHAFING PROTECTION ON HULL EXTERIOR FOR ANCHOR FLUKES.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Engineering
Issued 17 March 1988 Resolved
READJUST PORT FUEL REMOTE SHUTDOWN.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Lifesaving
Issued 17 March 1988 Resolved
PROVIDE TWO TYPE I ADULT LIFE JACKETS.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Documentation
Issued 17 March 1988 Resolved
PROVIDE FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Fire Fighting
Issued 18 March 1986 Resolved
PROVDE PROPER BRACKET FOR MAIN DECK B-II FIRE EXTINGUISHER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986 Resolved
DRAIN WATER FROM FISH DAVIT LIGHT AND PROPERLLY SECURE SAME
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986 Resolved
PROVIDE APPROVED ELECTRICAL CONNECTIONS FOR NEW DECORATOR LIGHT SYSTEM
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Documentation
Issued 18 March 1986 Resolved
CHANGE VESSEL DOCUEMENT TO REFLECT CORRECT ADDRESS.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Lifesaving
Issued 18 March 1986 Resolved
PROVIDE WATERTIGHT BOX FOR VESSEL'S PYROTECHNICS
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Navigation
Issued 18 March 1986 Resolved
REPAIR AND PROVE OPERATION OF VESSEL'S HORN
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986 Resolved
REMOVE OR PROPERLY TERMINATE DEAD END WIRES IN ELECTRICAL LOCKER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986 Resolved
REPAIR DAMAGED ELECTRICAL CABLE IN ELECTRICAL LOCKER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986 Resolved
INSTALL PROPER ELECTRICAL CONNECTION ON FRESH WATER PUMP
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Engineering
Issued 18 March 1986 Resolved
FREE UP FUEL TANK SHUT OFF VALVES
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Construction/Loadline
Issued 29 March 1985 Resolved
LABEL "EMERGENCY ESCAPE KEEP CLEAR" OUTSIDE ESCAPE HATCH.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
REPLACE PADLOCKS WITH QUICK ACTING CLIPS OR LATCHES INSIDE EMERGENCY ESCAPEHATCH.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
REMOVE FOAM FROM MUFFLER AND ENGINE COMPARTMENTS. (THIS REFERS TO THE GREY-BLACK FOAM LINING, NOT TO THE PELLET FLOTATION FOAM.)
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Electrical
Issued 29 March 1985 Resolved
SUBMIT PLAN OR LETTER AND SKETCH FOR NEW ELEC BATTERY CHARGER INSTALLATION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
SECURE ALL BOLTS, SHACKLES, ETC THROUGHOUT RIGGING WITH COTTER PINS, DOUBLENUTS, OR WIRE LASHING WHEREVER ONE COMING UNSCREWED WOULD CAUSE A BOOM, GAFF, YARD OR BLOCK TO FALL OR WHIP AROUND.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
REPAIR CRACKS IN RING BUOY COATING AND REPLACE DETERIORATED GRAB LINE OR REPLACE RING BUOY.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
DO NOT OPERATE MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE ON MAINLAND SHORE. AN AMENDMENT REDUCING ROUTE WILL BE ISSUED.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985 Resolved
DOUBLE UP HOSE CLAMPS ON MUFFLER OVERBOARD CONNECTIONS P/S.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
REPLACE MISSING GASKETS ON PORTHOLE WEATHER COVERS.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985 Resolved
MAKE ACCESS FOR FIRE PUMP CONTROLLEVER IN NEW ENGINE BOX. MAKE THIS ACCESSAND OTHER ACCESSES IN FUEL TANK HATCHES AND ENGINE COVERS AS CLOSE TO FUMETIGHT AS PRACTICABLE WITH GASKETS AND SEALANTS.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985 Resolved
REPLACE SWIVEL CONNECTING MORSE CABLE TO VALVE HANDLE ON STBD FO SHUTOFF AND PROVE OPERATION OF REMOTE CONTROL.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Navigation
Issued 29 March 1985 Resolved
REMOVE GLOSS FROM BLACK PAINT FWD OF RUNNING LIGHTS P/S SO SURFACE IS MATTE BLACK.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.