Records from 1985 to 2001. Most recent: inspection, 6 August 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
6 August 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428083
6 July 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361555
1 September 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378788
4 August 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1113023
5 May 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378696
28 April 1998
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383858
22 May 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398663
27 September 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1402324
18 April 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374578
29 April 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 865970
29 March 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1353717
17 November 1994
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429970
15 April 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1370830
16 March 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1165035
14 April 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144841
23 March 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 837043
11 March 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145045
27 November 1992
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828247
9 April 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1263275
20 March 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1010880
30 May 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910340
14 May 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213977
19 March 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 930263
19 March 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997311
20 March 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241060
10 October 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031239
15 May 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200778
17 March 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1040988
19 September 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1044814
4 May 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037425
25 March 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297914
17 March 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293299
31 March 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1327528
25 March 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1018808
30 July 1986
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 988165
30 June 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1001439
18 March 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304823
27 September 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301511
8 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289363
29 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 980273
Fire Fighting
Issued 4 August 1999
Resolved
Schedule an inspection of the new heat detector system for the engine compartments upon installation of system. System is to be installed IAW approved plans dated 04 AUG 99.
Condition: Unknown
Due 4 August 1999
Resolved 4 August 1999
Fire Fighting
Issued 5 May 1999
Resolved
Contact marine inspection office to arrange for approval of existing fire fighting system.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Engineering
Issued 5 May 1999
Resolved
Provide new 30x30 mesh screen over starboard fuel tank vent.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Fire Fighting
Issued 5 May 1999
Resolved
PROVIDE ELECTRCAL PLAN FOR THE INSTALLATION OF NEW HEAT DETECTORS IN ENGINECOMPARTMENTS. (NO COAST GUARD APPROVAL OF HEAT DETECTOR OK. SEE MOC POLICY LETTER 4-96. UNLESS PLANS ARE NOT APPROVED, INSTALLATION INSPECTION COMPLETE.)
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Fire Fighting
Issued 5 May 1999
Resolved
Provide adequate means to secure engine compartment vents in case of a fire.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Navigation
Issued 5 May 1999
Resolved
Provide updated charts of operating area.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999
Resolved
Provide or update light list for 1999.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999
Resolved
Provide emergency broadcast placard
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Navigation
Issued 5 May 1999
Resolved
Provide deviation table for magnetic compass.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Apply retro tape to both sides of buoyant apparatus.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Put new batteries in both buoyant apparatus water lights.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Ensure weak link is properly arranged so that it will be in tension after painter pays out.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Paint distress signal box orange.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Documentation
Issued 5 May 1999
Resolved
Ensure an employee assistance program (EAP) is administered for the crew.
Condition: Unknown
Due 2 June 1999
Resolved 2 June 1999
Construction/Loadline
Issued 27 September 1996
Resolved
Clean and treat dryrot in electrical compartment stbd side and on port sidearound exhaust discharge area.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Construction/Loadline
Issued 27 September 1996
Resolved
Clean and treat dryrot in way of middle bilge near packing gland coupling.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Construction/Loadline
Issued 27 September 1996
Resolved
Remove FRP from area around previous repair stbd aft quarter. Make available for MI to inspect wood for structural integrity.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 27 September 1996
Resolved
Make vessel available to Marine Inspector for underway check ride prior to carrying passengers for hire.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Accommodation/Occupational Safety
Issued 16 March 1994
Resolved
MOUNT CHARCOAL GRILL OUTBOARD OF RAIL OR REMOVE IT FROM THE VESSEL.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Engineering
Issued 16 March 1994
Resolved
GET VESSEL UNDERWAY IN A SEAWAY. PROVE PROPER OPERATION OF SAILS, RIGGING,ENGINES, AND STEERING GEAR. MAKE ENGINES AND STEERING GEAR READY FOR INSPECTION WHILE OPERATING.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Lifesaving
Issued 16 March 1994
Resolved
CONDUCT EMERGENCY DRILLS UNDERWAY.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 16 March 1994
Resolved
INSTALL POWER BILGE PUMP AND PIPING IN ACCORDANCE WITH 46 CFR 182.25.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Navigation
Issued 16 March 1994
Resolved
UPDATE LIGHT LIST, COAST PILOT, AND CHART.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Accommodation/Occupational Safety
Issued 16 March 1994
Resolved
REPLACE 1ST AND 3RD PORTHOLE WINDOWS FROM STERN ON PORT SIDE.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Construction/Loadline
Issued 16 March 1994
Resolved
RE-ATTACH BACKSTAY CHAIN PLATE ON STARBOARD TRANSOM.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Documentation
Issued 16 March 1994
Resolved
PROVIDE ON BOARD THE SIGNED ORIGINAL OF THE CERTIFICATE OF INSPECTION. _x001C_ _x001C_ (ATTENDING MARINE INSPECTOR WILL NEED TO ENDORSE ORIGINAL WHEN PROVIDED.)
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994
Resolved
RE-ATTACH GROUNDING STRAP IN AFT PORT BILGE.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994
Resolved
RENEW BATTERIES IN LANTERNS FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Electrical
Issued 16 March 1994
Resolved
REPLACE WING NUTS ON BATTERY FOR ELECTRONIC EQUIPMENT WITH PERMANENT-TYPE CONNECTORS.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Navigation
Issued 23 March 1993
Resolved
PROVIDE UP TO DATE LIGHT LIST, COAST PILOT, TIDE TABLES, AND UP TO DATE OR CORRECTED CHART.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Navigation
Issued 23 March 1993
Resolved
PREPARE A DEVIATION TABLE OR PROVIDE ANOTHER MEANS OF NAVIGATING.
Condition: Unknown
Due 16 April 1993
Resolved 29 March 1993
Lifesaving
Issued 23 March 1993
Resolved
STENCIL NUMBER OF LIFEJACKETS STORED IN EACH STORAGE AREA.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Accommodation/Occupational Safety
Issued 23 March 1993
Resolved
PROPERLY REPAIR 5TH PORT HOLE FROM THE BOW ON THE STARBOARD SIDE.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Lifesaving
Issued 23 March 1993
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Documentation
Issued 23 March 1993
Resolved
PROVIDE A WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Unknown
Issued 23 March 1993
Resolved
PROVIDE DOCUMENTATION OF THE VESSEL'S DRUG TESTING PROGRAM THAT DEMONSTRATES COMPLIANCE WITH 46 CFR 16, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 20 March 1992
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS UNDERWAY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Construction/Loadline
Issued 10 October 1989
Resolved
COMPLETELY REPLACE ALL 4 VERTICAL STRUCTURAL MEMBERS ANCHORING BOWSPRIT IN FOREPEAK.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Construction/Loadline
Issued 10 October 1989
Resolved
PROPERLY PATCH BROKEN/CRACKED WOOD AND RE-APPLY FIBERGLASS TO DAMAGED AREA ON PORT BOW NEAR WATERLINE.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Engineering
Issued 17 March 1989
Resolved
REPAIR #1 MDE THRUST BEARING.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989
Resolved
REPLACE CABLE CLAMPS FOR MIZZEN TOPMAST STAY CABLE AT THE MIZZEN TOPMAST.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989
Resolved
REPLACE 7 ADULT AND 2 CHILD-SIZED PFD'S.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989
Resolved
PROVIDE 6 ORANGE HAND-HELD FLARES.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Fire Fighting
Issued 17 March 1989
Resolved
PROVIDE 20 FT OF DISCHARGE AND 10 FT OF SUCTION HOSE FOR THE HAND-HELD PORTABLE FIRE PUMP.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Lifesaving
Issued 17 March 1989
Resolved
REPLACE PORTSIDE BUOYANT APPARATUS WATERLIGHT BATTERY.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989
Resolved
PROPERLY REPAIR TERMITE DAMAGE TO THE MAINMAST SECOND TIER (MAIN TOPMAST) AND ALL ATTACHMENTS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Construction/Loadline
Issued 17 March 1989
Resolved
PROPERLY SECURE UPPER BOLT TO MIZZENMAST, FWD STAY, CHAIN PLATE, STARBOARD SIDE.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Accommodation/Occupational Safety
Issued 17 March 1989
Resolved
REPAIR BROKEN FOOTINGS FOR SECOND TIER RATLINES, MIZZENMAST.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Engineering
Issued 17 March 1989
Resolved
REPAIR LEAKING PACKING GLANDS FOR BOTH SHAFTS.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 17 March 1989
Resolved
REPAIR LEAK AT RUDDER POST FOUNDATION.
Condition: Unknown
Due 17 March 1989
Resolved 17 March 1989
Navigation
Issued 19 September 1988
Resolved
MAKE PERMANENT REPAIRS TO STEERING GEAR PRIOR TO OPERATING.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Navigation
Issued 19 September 1988
Resolved
INSTALL RUDDER STOPS AT VESSEL'S NEXT DRYDOCKING BUT NO LATER THAN 30 SEPTEMBER 1989.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Construction/Loadline
Issued 25 March 1988
Resolved
PROVIDE CHAFING PROTECTION ON HULL EXTERIOR FOR ANCHOR FLUKES.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Engineering
Issued 17 March 1988
Resolved
READJUST PORT FUEL REMOTE SHUTDOWN.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Lifesaving
Issued 17 March 1988
Resolved
PROVIDE TWO TYPE I ADULT LIFE JACKETS.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Documentation
Issued 17 March 1988
Resolved
PROVIDE FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 17 March 1988
Resolved 17 March 1988
Fire Fighting
Issued 18 March 1986
Resolved
PROVDE PROPER BRACKET FOR MAIN DECK B-II FIRE EXTINGUISHER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986
Resolved
DRAIN WATER FROM FISH DAVIT LIGHT AND PROPERLLY SECURE SAME
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986
Resolved
PROVIDE APPROVED ELECTRICAL CONNECTIONS FOR NEW DECORATOR LIGHT SYSTEM
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Documentation
Issued 18 March 1986
Resolved
CHANGE VESSEL DOCUEMENT TO REFLECT CORRECT ADDRESS.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Lifesaving
Issued 18 March 1986
Resolved
PROVIDE WATERTIGHT BOX FOR VESSEL'S PYROTECHNICS
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Navigation
Issued 18 March 1986
Resolved
REPAIR AND PROVE OPERATION OF VESSEL'S HORN
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986
Resolved
REMOVE OR PROPERLY TERMINATE DEAD END WIRES IN ELECTRICAL LOCKER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986
Resolved
REPAIR DAMAGED ELECTRICAL CABLE IN ELECTRICAL LOCKER
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Electrical
Issued 18 March 1986
Resolved
INSTALL PROPER ELECTRICAL CONNECTION ON FRESH WATER PUMP
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Engineering
Issued 18 March 1986
Resolved
FREE UP FUEL TANK SHUT OFF VALVES
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Construction/Loadline
Issued 29 March 1985
Resolved
LABEL "EMERGENCY ESCAPE KEEP CLEAR" OUTSIDE ESCAPE HATCH.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985
Resolved
REPLACE PADLOCKS WITH QUICK ACTING CLIPS OR LATCHES INSIDE EMERGENCY ESCAPEHATCH.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985
Resolved
REMOVE FOAM FROM MUFFLER AND ENGINE COMPARTMENTS. (THIS REFERS TO THE GREY-BLACK FOAM LINING, NOT TO THE PELLET FLOTATION FOAM.)
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Electrical
Issued 29 March 1985
Resolved
SUBMIT PLAN OR LETTER AND SKETCH FOR NEW ELEC BATTERY CHARGER INSTALLATION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985
Resolved
SECURE ALL BOLTS, SHACKLES, ETC THROUGHOUT RIGGING WITH COTTER PINS, DOUBLENUTS, OR WIRE LASHING WHEREVER ONE COMING UNSCREWED WOULD CAUSE A BOOM, GAFF, YARD OR BLOCK TO FALL OR WHIP AROUND.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985
Resolved
REPAIR CRACKS IN RING BUOY COATING AND REPLACE DETERIORATED GRAB LINE OR REPLACE RING BUOY.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985
Resolved
DO NOT OPERATE MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE ON MAINLAND SHORE. AN AMENDMENT REDUCING ROUTE WILL BE ISSUED.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985
Resolved
DOUBLE UP HOSE CLAMPS ON MUFFLER OVERBOARD CONNECTIONS P/S.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985
Resolved
REPLACE MISSING GASKETS ON PORTHOLE WEATHER COVERS.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Construction/Loadline
Issued 29 March 1985
Resolved
MAKE ACCESS FOR FIRE PUMP CONTROLLEVER IN NEW ENGINE BOX. MAKE THIS ACCESSAND OTHER ACCESSES IN FUEL TANK HATCHES AND ENGINE COVERS AS CLOSE TO FUMETIGHT AS PRACTICABLE WITH GASKETS AND SEALANTS.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985
Resolved
REPLACE SWIVEL CONNECTING MORSE CABLE TO VALVE HANDLE ON STBD FO SHUTOFF AND PROVE OPERATION OF REMOTE CONTROL.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Navigation
Issued 29 March 1985
Resolved
REMOVE GLOSS FROM BLACK PAINT FWD OF RUNNING LIGHTS P/S SO SURFACE IS MATTE BLACK.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985