Engineering › Sea-water System (primary cooling) › Piping
Issued 29 August 2006
Resolved
Double hose clamp S/W cooling hose #1 MDE.
Due 10 September 2006
Resolved 6 September 2006
Resolution: Sighted by attending Marine Inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 August 2006
Resolved
Secure all battery box covers.
Due 10 September 2006
Resolved 10 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 29 August 2006
Resolved
Repair or replace #1 MDE RPM Gauge.
Due 10 September 2006
Resolved 10 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 29 August 2006
Resolved
Adjust shaft packing, #1 shaft.
Due 30 August 2006
Resolved 6 September 2006
Resolution: Sighted by attending Marine Inspector.
Engineering › Bilge Water Management System › Manifold
Issued 29 August 2006
Resolved
Label bilge manifold.
Due 30 August 2006
Resolved 6 September 2006
Resolution: Sighted by attending Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 August 2006
Resolved
Repair exhaust leak in lazarette.
Due 8 September 2006
Resolved 6 September 2006
Resolution: Sighted by attending Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 August 2006
Resolved
Repair lagging on #2 MDE.
Due 8 September 2006
Resolved 6 September 2006
Resolution: Sighted by attending Marine Inspector.
Construction/Loadline › Structures › Door
Issued 29 August 2006
Resolved
Replace doors from 3rd deck poker room to 3rd deck exterior.
Due 30 September 2006
Resolved 29 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Superstructure
Issued 29 August 2006
Resolved
Replace window frame 2nd deck starboard door.
Due 30 September 2006
Resolved 29 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Structures › Manhole
Issued 29 August 2006
Resolved
Stencil emergency escape hatch from galley.
Due 10 September 2006
Resolved 10 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 August 2006
Resolved
Prove proper operation of emergency light #17.
Due 8 September 2006
Resolved 8 September 2006
Resolution: Per fax letter fm O/O, ltr scanned into documents for this activity.
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 January 2006
Resolved
Make repairs to hydraulic lines
Condition: Unknown
Due 13 January 2006
Resolved 13 January 2006
Resolution: MI noted repair to lines.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 June 2005
Resolved
Repair stove pan guard/rail.
Due 3 June 2005
Resolved 3 June 2005
Lifesaving › Inflatable Buoyant Apparatus › Quantity
Issued 1 June 2005
No resolution recorded
Provide enough IBA's for 67% of 505 persons (339 or 7 50 man IBA's).
See Special Note.
Action required: 705 - Other - as specified
Engineering › Bilge Water Management System › Not Operational
Issued 26 May 2005
Resolved
Prove proper operation of all bilge suction piping systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: Replaced strainer in fixed FF compartment. All compartments drained water to my satisfaction.
Engineering › Bilge Water Management System › Piping
Issued 26 May 2005
Resolved
Replace bilge piping in Lazerrette. Provide original schedule rating IAW vessels plans.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: Replaced rusted piping with new, cleaned out strainer and check valve to ensure proper operation. The new piping went through the bulkhead into the E/R, where there was a watertight fitting on the other side. Condcuted a hose test to ensure seal.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 May 2005
Resolved
Provide audio and visual high level bilge alarm in lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: New alarm installed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 May 2005
Resolved
Provide up to date addresses and contacts for Epirb Registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Engineering › Bilge Water Management System › Valve
Issued 26 May 2005
Resolved
Label emergency valve shutdown in forepeak, also provide tool to enable personnel to work valve.
Due 3 June 2005
Resolved 3 June 2005
Resolution: Wrench secured to wall next to emg. valve sign.
Engineering › Bilge Water Management System › Manifold
Issued 26 May 2005
Resolved
Label bilge manifold to compartment in engine room.
Due 3 June 2005
Resolved 3 June 2005
Resolution: Number of hold placed on piping next to valve, ships hold diagram above markings.
Construction/Loadline › Structures › Ventilators
Issued 26 May 2005
Resolved
Prove proper operation of all fire dampers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2005
Resolved 3 June 2005
Resolution: All fire dampers were worked. A fusible link is what holds the mechanically springed gates open. The fusible link is rated at 165 degrees.
Engineering › Steering Gear System › Rudder
Issued 11 March 2005
Resolved
Demonstrate to the satisfaction of attending marine inspector that rudder is capable of movement up to 35-degrees from midship to PT and STBD respectively, per 46 CFR 58.25-10(b). To be completed at drydock.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 4 April 2005
Engineering › Steering Gear System › Rudder
Issued 11 March 2005
Resolved
Provide rudder stops as required by 46 CFR 58.25-50 to the satisfaction of attending Coast Guard marine inspector. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 4 April 2005
Resolution: The steering system design already provides for positive stops.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 11 March 2005
Resolved
Provide rudder angle indicator in steering gear compartment (lazarette) per 46 CFR 58.25-25. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 4 April 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 March 2005
Resolved
Replace high pressure hydraulic hose serving steering gear rams, as needed, where fittings of existing hydraulic lines are corroded/pitted. To be completed at next drydock.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 4 April 2005
Engineering › Steering Gear System › Power Unit
Issued 11 March 2005
Resolved
Provide steering gear failure alarm as required by 46 CFR 58.25-25(b). To be completed at next drydock.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 4 April 2005
Resolution: Not required on a vessel under 1600 gross tons.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Remove the unauthorized pipe penetration in the aft engine room bhd just stbd of the centerline in the bilge.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 4 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Crop out unauthorized doubler in the engine room aft bhd IWO centerline at the bottom plate and insert.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 4 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Crop and renew existing improper insert in the engine room aft bhd just port of centerline approx. 4 ft. above bottom plate.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 4 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005
Resolved
Crop and renew the wasted portions of the watertight bhd between the engine room and the lazzaretto to include the 2" dia. hole with the authorized temporary repair.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 4 April 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Repair STBD, FWD, door window on 3rd deck. (Window has a hole in the middle of a large crack)
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Repair STBD, FWD door latch on 3rd deck. Door latch is broken and will not hold door closed.
Condition: Improper/Lack of Maintenance
Due 1 March 2005
Resolved 18 February 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Repair PORT & STBD AFT door latches on 3rd deck. Latches are broken and do not hold door in the closed position.
Condition: Improper/Lack of Maintenance
Due 1 March 2005
Resolved 18 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, conduct underway drills for crew IAW 46CFR122.420 and 46CFR520&524. Master has not conducted drills with crew. Master stated they have only talked about the drills required.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Communications › Radio Communications › EPIRB
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, replace hydrostatic release for EPIRB IAW 46CFR115.808(a)(5). Sticker on the side of hydro-static release has expiration date of MAY 03 & 04. Some one has crossed out 03 & 04.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Lifesaving › Buoyant Apparatus › Approval
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, replace 2 ring life buoys IAW 46CFR117.70. Rings were faded to a white color and inside seals were falling off. Retro and name was 75% off each ring.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, provide 4 inch courses IAW 46CFR116.900(f)(1)(iii). STBD side rail banner, which they use to contain passengers, was removed for cleaning. They were going to get U/W with just plastic "CAUTION" tape accross the entire STBD side to block a 2ft opening along the rail.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Lifesaving › Lifefloat › Float Free
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, make all life floats ready to float free IAW 46CFR117.130. Float light lines were tied off to stanchions, which would prevent LF's to float free.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, repair float light on AFT life float IAW 46CFR117.175. One float light was on the deck and not in the holder, which caused the light to drain it's battery.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Lifesaving › Lifefloat › Paddle
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, label all LF paddles IAW 46CFR122.604(g). Paddles did not have the vessels name on them.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Make STBD, main deck door weathertight IAW 46CFR171.124. Door frame and seal is wasted and you can see day light from the inside.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Make PORT, main deck door weathertight and operable, IAW 46CFR171.124. Frame, seal, and hinges are wasted. You can see day light from inside vessel. Door had to be pried open because the top hinges were frozen.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Stability › Watertight Integrity › General
Issued 15 February 2005
Resolved
Make shore tie pipe watertight to prevent down flooding of engine room IAW 46CFR171.124. Both PORT and STBD shore tie port sealing caps (approx 10in dia) were broken off allowing water to enter engine room
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 February 2005
Resolved
Update emergency evacuation plan to include requirements of 46CFR116.520 and 116.530 Fire Plan & PFD locker on 3rd deck.
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, remove all fuel oil and oil from engine room bilge IAW 46CFR115.830. Engine room bilge water had a good layer of diesel fuel with oil.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Steering Gear System › Power Unit
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, repair cooling fan for KOBALT THROTTLE SYSTEM. Plus provide a second, for back-up. (See CG-835 #33). This system was installed in Miami and a fan was installed next to the unit for cooling. If unit temperature increased to a certain point, a steering system malfunction would occur. Fan motor was OOC.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 15 February 2005
Resolved
Repair oil and fuel oil leaks on boath MDE's IAW 46CFR115.804. Engineer had rags stuffed in several areas around engine to prevent oil from leaking.
Condition: Improper/Lack of Maintenance
Due 1 March 2005
Resolved 18 February 2005
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, repair leaks on PORT MDE raw water cooling pipe. Remove three soft patches. They had rubber soft patches, secured by hose clamps over wasted pipe to prevent leaking.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, find and repair L/O leak on AFT end of port GENSET. Remove and clean, or replace exhaust legging, IAW 46CFR115.804. They had two oil absorbent rags hanging next to generator to catch oil spray.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Fuel Oil Service System › Piping
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, repiar F/O leak on F/O hard piping going to port GENSET. Elbows in piping prior to the racor filters had standing fuel.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Fuel Oil Service System › Piping
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, prove all F/O lines meet J-1942 hose, if not, replace. Found a few hoses that could not be identified and did not appear to be the proper wall thickness required for fuel line. Hose connections were missing the second hose clamp.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, clear out engine room escape route IAW 46CFR116.500. An empty 55 gallon oil drum and tool boxes are sitting under escape hatch.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, clear out Store Room escape route, IAW 46CFR116.500. Several pots and pans, along with boxes were in the isle heading to the escape hatch.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, clean all oil from port engine room exhaust fan and duct work IAW 46CFR115.804. The entire area under the fan and fan housing is covered in oil. Unknown cause except for engine room air from engine crankcase breathers.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2005
Resolved
Provide covers for PTO's on both GENSETS IAW 46CFR116.960. PTO's and associated pulleys/belts exposed, and could cause harm if working around area.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Engineering › Diesel Engine (auxiliary) › Block
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, find and repair L/O leak on AFT end of STBD GENSET. Remove and clean, or replace, exhaust legging IAW 46CFR119.200. Oil seemed to be coming from the turbo drain line and being slung around area via the fly wheel. This in turn has soaked the legging which covers the hot exhaust pipes.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, secure all CO2 bottles located in store room IAW 46CFR115.830. They have several bottles sitting on the deck held together by 1/8 inch packing string. If in heavy seas, could knock over bottles causing one of the ends to break off these high pressure cylinders.
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 February 2005
Resolved
Reduce fire load in store room by removing all card board boxes and misc items that are not used on vessel. Room was loaded with misc paper products still in card board boxes. By removing the items out of the shipping boxes, this will lower the fire load in space.
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, secure all galley equipment IAW 46CFR115.830. Ovens are not secure along with serving tables.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, prove passengers orientation meets 46CFR122.506. Provide written announcement. Master could not produce a orientation, but just what he had memorized. No company written/standard speech.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, open and make ready for inspection the after steering space. Master stated that you could not enter space due to the high level of exhaust leaks in space.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Fire Fighting › Fixed Fire Detection System › Approval
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, have entire fire detection system serviced and tested with USCG onboard. System was showing pull station faults throughout vessel and crew could not clear them.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Steering Gear System › Power Unit
Issued 15 February 2005
Resolved
Provide a report from KOBALT attesting to the proper installation of all equipment. (see #16) This is the system that over heats and causes steering casualties along with throttle problems.
Condition: Improper/Lack of Maintenance
Due 15 March 2005
Resolved 4 March 2005
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, provide original copies of all masters.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Stability › Weathertight Integrity › General
Issued 15 February 2005
Resolved
Provide latches for side doors on 2nd deck. They removed door latches and installed a bolt lock to open and close door.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 18 February 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 15 February 2005
Resolved
Remove all plastic trasch cans to reduce fire load through out vessel IAW 46CFR116.427 Cans should meet 46CFR164.009.
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, provide donning placards IAW 46CFR122.516. They had donning placards posted, but for the wrong style life preservers.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Personnel › Training › Familiarization Training
Issued 15 February 2005
Resolved
Provide a maintenance/training program for all machinery & electrical systems on vessel, and written procedures for special machinery operations. (ie. cooling fan, fixed extinguishing system, fire detection system, etc.) Due to the complexity of several systems onboard, crew needs some means of keeping up with maintenance procedures and working knowledge.
Condition: Improper/Lack of Maintenance
Due 15 March 2005
Resolved 4 March 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 February 2005
Resolved
Prove current configuration of 3rd deck open qualified refuge area meets intent of approved plan IAW 46CFR116. They have installed two sliding doors on the AFT part of the 3rd deck refuge area. They are not shown on the plans they have posted.
Condition: Improper/Lack of Maintenance
Due 15 March 2005
Resolved 16 June 2005
Lifesaving › Buoyant Apparatus › Approval
Issued 15 February 2005
Resolved
Provide lifesaving equipment maintenance checklist for specific items IAW 46CFR122.702. No log provided.
Condition: Improper/Lack of Maintenance
Due 1 March 2005
Resolved 18 February 2005
Stability › Watertight Integrity › General
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, repair all broken vent goose necks to prevent down flooding. Vent to after steering, port side, was cracked and allows water to enter void. Upon further inspection of other vents, it appears that they all need repair of some sort.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, post emergency instructions in wheelhouse IAW 46CFR122.510.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, provide written instructions to master for reporting marine casualty to MSO Tampa IAW 46CFR Part 122. Masters need to know and understand what to do after a marine casualty.
Condition: Improper/Lack of Maintenance
Due 15 February 2005
Resolved 18 February 2005
Engineering › Bilge Water Management System › Manifold
Issued 15 February 2005
Resolved
Prior to the carriage of passengers, prove proper operation of bilge system and bilge high level alarms. This was not tested while onboard. Spot check.
Condition: Unknown
Due 15 February 2005
Resolved 18 February 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 15 February 2005
Resolved
Post HOTLINE number. No HOTLINE numbers were available for crewmembers.
Condition: Improper/Lack of Maintenance
Due 22 February 2005
Resolved 18 February 2005
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 February 2005
Resolved
Provide EAP Training IAW 46CFR16.401 and display info. No training has been provided for entire new crew.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 15 February 2005
Resolved
Provide written policy for meeting alcohol testing under 46CFR Part 16 and 33CFR Part 95.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 15 February 2005
Resolved
Provide draft marks on FWD and AFT part of vessel. None could be seen from the dock. Vessel has an up-coming dry dock in March.
Condition: Improper/Lack of Maintenance
Due 31 March 2005
Resolved 4 April 2005
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 February 2005
Resolved
Provide in writing, a Designated Employee Representative (EAP) for company IAW 49CFR100. Noting in writing at this time.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Operations/Management › Drills/Instruction › Fire
Issued 15 February 2005
Resolved
Update emergency instructions IAW 46CFR122.510 & .512. Instructions are to vague, and does not outline all the items required in the regulation.
Condition: Improper/Lack of Maintenance
Due 4 March 2005
Resolved 4 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 July 2004
Resolved
REPAIR ENGINE AND GENSET SHUT DOWNS ON FIXED CO2 FIREFIGHTING SYSTEM.
Due 1 August 2004
Resolved 22 July 2004
Resolution: NOT REQUIRED
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 July 2004
Resolved
ADD RESCUE PLATFORM AND PORTABLE WET CHEMICAL EXTINGUISHER IN GALLEY TO FIRE SAFETY PLAN.
Due 1 August 2004
Resolved 22 July 2004
Resolution: PEN AND INKED.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 1 July 2004
Resolved
PROVIDE FLAME BOWL AND METALLIC DRAIN FOR PORT GENSET RAYCOR.
Due 1 August 2004
Resolved 22 July 2004
Resolution: SAT
Engineering › Bilge Water Management System › Piping
Issued 1 July 2004
Resolved
PROVIDE WRENCH FOR OPERATING SUCTION VALVE REACH ROD IN GALLEY.
Due 1 August 2004
Resolved 22 July 2004
Resolution: SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 July 2004
Resolved
REPAIR EXHAUST LEAKS ON STBD GENSET AND PORT MDE PIPING IN STEERING SPACE.
Due 15 February 2005
Resolved 18 February 2005
Electrical › Lighting (service) › Outlet Box
Issued 1 July 2004
Resolved
REPAIR OUTLET BOX IN WAY OF MAIN DECK PORT AFT CORNER.
Due 1 August 2004
Resolved 22 July 2004
Resolution: SAT
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2004
Resolved
REPAIR LIGHT FIXTURE IN 3RD DECK FEMALE HEAD.
Due 1 August 2004
Resolved 22 July 2004
Resolution: REMOVED.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2004
Resolved
REMOVE ALL ELECLTRICAL STRIPS THROUGHOUT VESSEL. ANY EXTRA OUTLETS INSTALLED MUST BE ADDED TO ELECTRICAL PLAN AND APPROVED BY MSC.
Due 1 August 2004
Resolved 22 July 2004
Resolution: REMOVED.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 July 2004
Resolved
REPAIR OUTLET BEHIND COIN ROLLING MACHINE ON MAIN DECK CASH CAGE.
Due 1 August 2004
Resolved 28 July 2004
Resolution: SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 1 July 2004
Resolved
PROVIDE APPROVED PLAN FOR FIXED CO2 FIREFIGHTING SYSTEM INSTALLATION.
Due 1 August 2004
Resolved 18 February 2005
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 1 July 2004
Resolved
REPAIR ALL MISSING OVERHEAD INSULATION IN ENGINE ROOM.
Due 1 August 2004
Resolved 22 July 2004
Resolution: TEMP REPAIR. NEEDS TO BE SECURED BETTER.
Lifesaving › Lifejacket/PFD (Type V) › Quantity
Issued 1 July 2004
Resolved
PROVIDE APPROVED WORK VESTS FOR MARINE CREW.
Due 1 August 2004
Resolved 29 July 2004
Resolution: 5 NEW JACKETS.
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 20 April 2004
Resolved
Prior to night time operation, or in un-favorable tide conditions, (as discussed), prove proper operation of your new STBD engine, as per your letter dated 20APR04. LEGACY COMPONENT DESC: Filing Written Report of Marine Casualty
Condition: Improper Installation
Due 20 April 2004
Resolved 22 April 2004
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 20 April 2004
Resolved
Prior to the operation with passengers, submit a CG-2692 for engine failure on 19APR04. LEGACY COMPONENT DESC: Filing Written Report of Marine Casualty
Condition: Unknown
Due 20 April 2004
Resolved 21 April 2004
Construction/Loadline › Penetrations
Issued 30 December 2003
Resolved
Provide up-dated plans to show new engine room exhaust system IAW 46CFR116.202. (Electrical, deck lay-out, fire control, etc.)
Due 14 February 2004
Resolved 14 January 2004
Resolution: Rcv''d plans, reviewed and approved plans and visited vessel and witnessed installation and testing - all sat.
Accommodation/Occupational Safety › Ventilation
Issued 3 November 2003
Resolved
Provide an exhaust system for engine room. LEGACY COMPONENT DESC: Engine room exhaust
Condition: Placed in Improper Service
Due 31 December 2003
Resolved 14 January 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 August 2003
Resolved
REPAIR EXHAUST LEAK IN AFTER STEERING AND VENTILATE SPACE FOR INSPECTION. LEGACY COMPONENT DESC: Piping (exhaust)
Due 25 August 2003
Resolved 27 August 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 August 2003
Resolved
CLEAN OIL SOAKED LAGGING IN WAY OF PORT GENSET, AFT EXHAUST, AND BULKHEAD. LEGACY COMPONENT DESC: Exhaust Lagging
Due 25 August 2003
Resolved 3 November 2003
Deck/Cargo › Holds/Tanks
Issued 19 August 2003
Resolved
MOUNT WRENCH NEXT TO EACH DECK HATCH. LEGACY COMPONENT DESC: Hatch Cover
Due 25 August 2003
Resolved 27 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 August 2003
Resolved
CALIBRATE OIL GAUGES ON BRIDGE IAW MANUFACTURER. LEGACY COMPONENT DESC: Gauges
Due 25 August 2003
Resolved 27 August 2003
Personnel › Certificates/Documents/Licenses
Issued 19 August 2003
Resolved
PROVIDE SENIOR DECKHAND LETTER. LEGACY COMPONENT DESC: Senior Deckhand
Due 25 August 2003
Resolved 27 August 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 August 2003
Resolved
Repair oil leak IWO of rear oil seal on PORT GENSET.
Condition: Improper/Lack of Maintenance
Due 27 September 2003
Resolved 3 November 2003
Operations/Management › Passenger Operations
Issued 20 May 2003
Resolved
Update fire safety plan IAW current lifesaving equipment locations. LEGACY COMPONENT DESC: Safety Plan
Condition: Improper/Lack of Maintenance
Due 22 June 2003
Resolved 23 June 2003
Electrical › Lighting (emergency)
Issued 20 May 2003
Resolved
Repair emergency lighting in engine room and second deck stair tower. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 26 May 2003
Resolved 23 June 2003
Accommodation/Occupational Safety › Ventilation
Issued 20 May 2003
Resolved
Provide a safety shield for fan that cools electrical circuit board in engine room, amid ship, FWD BLKHD. LEGACY COMPONENT DESC: Protective shield
Condition: Improper/Lack of Maintenance
Due 22 June 2003
Resolved 23 June 2003
Engineering › Pressure Vessel
Issued 18 March 2003
Resolved
Renew the pressure relief valve for the hot-water heater (fwd) in the storage room. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Due 18 April 2003
Resolved 23 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 March 2003
Resolved
Ensure that all piping IWO the fixed fire fighting system is high-pressure piping appropriate for the installation (ASTM A53, 106).
Condition: Improper Installation
Due 18 April 2003
Resolved 21 March 2003
Resolution: Done.
Electrical › Electrical Distribution System (service)
Issued 18 March 2003
Resolved
Make wire connections IWO high level alarms moisture tight or in J-box as appropriate. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Due 18 April 2003
Resolved 23 June 2003
Construction/Loadline › Hull
Issued 18 March 2003
Resolved
Provide a repair proposal for welding bilge knuckle IWO fuel tanks port and starboard. LEGACY COMPONENT DESC: Weld
Condition: Improper Installation
Due 18 April 2003
Resolved 21 March 2003
Resolution: Resolved
Construction/Loadline › Hull
Issued 18 March 2003
Resolved
Provide a remedy proposal to address the pitting IWO the bow thruster tunnel. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 21 March 2003
Resolved 21 March 2003
Documentation › Certificates/Documents › Stability Letter
Issued 18 March 2003
Resolved
Provide documentation or stability letter with all installed ballast included.
Condition: Unknown
Due 21 March 2003
Resolved 21 March 2003
Resolution: Resolved.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 January 2003
Resolved
Reapir and demonstrate proper operation of starboard engine and marine gear. Make replaced parts available for inspection. LEGACY COMPONENT DESC: Flex Coupling
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2003
Resolved 23 January 2003
Resolution: Examined damaged flex coupling, coupling rplaced with new part, tested engine ahead and astern test sat.
Engineering › Thrusters
Issued 9 July 2002
Resolved
Repair and prove proper operation of bow thruster.
Due 1 September 2003
Resolved 19 August 2003
Resolution: SAT
Fire Fighting › Fire Pumps
Issued 9 July 2002
Resolved
Repair mechanical seal on primary fire pump.
Due 9 August 2002
Resolved 23 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 9 July 2002
Resolved
Ensure engine room escape stays clear at all times.
Due 10 July 2002
Resolved 23 August 2002
Lifesaving › Lifejacket/PFD (General)
Issued 9 July 2002
Resolved
Submit proposal to redistribute lifejackets throughout the vessel. LEGACY COMPONENT DESC: Storage
Due 9 August 2002
Resolved 23 August 2002
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System
Issued 9 July 2002
Resolved
Provide and post operating intructions for galley fixed firefighting. LEGACY COMPONENT DESC: Operation Controls
Due 9 August 2002
Resolved 23 August 2002
Communications › Audible Communications
Issued 9 July 2002
Resolved
Ensure P/A system works during loss of electrical power.
Due 10 July 2002
Resolved 10 July 2002
Documentation › Certificates/Documents
Issued 27 February 2002
Resolved
Provide current stability letter, prior to carry passengers LEGACY COMPONENT DESC: Stability Letter
Due 27 February 2002
Resolved 4 March 2002
Construction/Loadline › Structures
Issued 27 February 2002
Resolved
Provide securing lines for all watertight hatches exposed on weatherdeck. LEGACY COMPONENT DESC: Manhole
Due 14 March 2002
Resolved 14 March 2002
Communications › Alarms/Indicators
Issued 27 February 2002
Resolved
Provide speakrs for PA system on open decks. LEGACY COMPONENT DESC: General Alarm
Due 14 March 2002
Resolved 14 March 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 27 February 2002
Resolved
Provide sea rails for stove and grill.
Due 27 February 2002
Resolved 14 March 2002
Documentation › Safety/Response Plans/Programs
Issued 27 February 2002
Resolved
Provide fire control plan that complies with 46 CFR 116.530 LEGACY COMPONENT DESC: Fire Control Plans
Due 14 March 2002
Resolved 14 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Remove wire nuts and provide pressure type connectors on bridge equipment. LEGACY COMPONENT DESC: Wiring
Due 14 March 2002
Resolved 14 March 2002
Electrical
Issued 6 August 2001
Resolved
REPAIR/RENEW/REMOVE WIRE NUTS UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 6 August 2001
Resolved
PROVIDE SUPERVISOR TRAINING FOR ALL CAPTAINS.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 6 August 2001
Resolved
PROVIDE COPY OF ANNUAL REPORT.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 6 August 2001
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 6 August 2001
Resolved
LOG ALL CREW TRAINING.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 6 August 2001
Resolved
MARK "DISTRESS SIGNALS" ON CABINET WHERE THEY ARE STORED.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 6 August 2001
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 6 August 2001
Resolved
REGISTER EPIRB.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 6 August 2001
Resolved
FCC STATION LICENSE & FCC SAFETY CERTIFICATE HAVE DIRREFERNT CALL SIGNS. CORRECT.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 6 August 2001
Resolved
REPLACE GASKET ON PORT AND STBD SIDE WTD DOOR ON MAIN PASSENGER DECK.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Fire Fighting
Issued 6 August 2001
Resolved
REPAIR MAGNETIC RELEASE FIRE DOOR TO GALLEY. IT DOES NOT LATCH.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Fire Fighting
Issued 6 August 2001
Resolved
PROVIDE TAMPER PROOF SEAL ON PORTABLE EXTINGUISHER ON PORTSIDE STAIRWELL, MAIN DECK.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 6 August 2001
Resolved
PROVIDE APPROPRIATE SIZE PADDLES ON LIFEFLOATS.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Construction/Loadline
Issued 6 August 2001
Resolved
REPAIR AUDIBLE BILGE ALARM FOR ENGINE ROOM SPACE.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Construction/Loadline
Issued 6 August 2001
Resolved
PROVIDE WRENCH FOR REACHROD FOR BILGE SUCTION FOR FORWARD PEAK.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Documentation
Issued 6 August 2001
Resolved
POST ALL PAGES OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Lifesaving
Issued 6 August 2001
Resolved
REPAIR 1 LIFEFLOAT IN ACCORDANCE WITH MANUFACTURER'S GUIDELINES.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Engineering
Issued 29 March 2001
Resolved
Install remote fuel shut off valve aft of fuel tank IAW 46CFR119.455._x001C_ _x001C_
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Documentation
Issued 22 May 2000
Resolved
SHOW COMPLIANCE W/ CG DRUG TESTING REGS.
Condition: Unknown
Due 22 May 2000
Resolved 30 May 2000
Lifesaving
Issued 13 March 2000
Resolved
PROVIDE A WRITTEN PROCEDURE OR PLACARD FOR DEPLOYING ALL LIFESAVING EQUIPMENT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 12 January 2000
Resolved
PROVIDE ONBOARD THE REQUIRED INFLATABLE BUOYANT APPARATUS IAW [name withheld] LETTER OF NOVEMBER 30, 1999. FOR EACH IBA NOT FITTED BY THE SPECIFIED DATES THE MAXIMUM NUMBER OF PASSENGERS SHALL BE REDUCED BY 150 PERSONS.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Lifesaving
Issued 12 January 2000
Resolved
VESSELS ROUTE IS LIMITED TO SIX MILES FROM SHORE IN OUR ZONE UNTIL AN IBA IS FITTED.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Lifesaving
Issued 12 January 2000
Resolved
VESSEL SHALL MAINTAIN THE RADIO CHECK WITH SET ROUTE AND SCHEDULE IAW [name withheld] LETTER OF NOVEMBER 19, 1999.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Electrical
Issued 3 August 1999
Resolved
LABEL BREAKERS IN BREAKER BOX, STBD SIDE E/R.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Electrical
Issued 3 August 1999
Resolved
PROVIDE AND INSTALL LIGHT FIXTURE IN OPENING PROVIDED FOR SAME LOCATED ON SECOND DECK , STBD SIDE IWO ATM MACHINE.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Electrical
Issued 3 August 1999
Resolved
PROVIDE AND INSTALL ELECTRICAL OUTLET AND COVER IN OUTLET BOX LOCATED ON MAIN DECK, STBD SODE AFT.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Accommodation/Occupational Safety
Issued 3 August 1999
Resolved
SECURE STORAGE RACKS IN STORAGE ROOM.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Electrical
Issued 3 August 1999
Resolved
INSTALL BREAKER BOX COVER ON BREAKER BOX IN LADDER WELL LEADING UP FROM STARAGE ROOM.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Unknown
Issued 3 August 1999
Resolved
REPLACE PLASTIC PIPING THAT LEADS FROM LADDER WELL COMING UP FROM STORAGE ROOM THROUGH BULKHEAD INTO FEMALE HEAD.
Condition: Unknown
Due 31 August 1999
Resolved 14 September 1999
Accommodation/Occupational Safety
Issued 3 August 1999
Resolved
LABEL THE EMERGENCY ESCAPE SCUTTLE LEADING FROM STORAGE ROOM TO MAIN DECK AND UNCOVER SAME. INSURE THAT THE CHAIRS ABOVE THE SCUTTLE SERVING THE SLOT MACHINES ARE REMOVED.
Condition: Unknown
Due 31 August 1999
Resolved 14 September 1999
Electrical
Issued 3 August 1999
Resolved
PROVE OPERATION OF EMERGENCY LIGHTING IN LADDERWAY LEADING INTO E/R, AFT BHD OF E/R, AND ON MAIN DECK OUTSIDE OF E/R ENTRANCE.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Accommodation/Occupational Safety
Issued 3 August 1999
Resolved
PROVIDE AND INSTALL NON-SKID TREADS OR MATERIAL ON STAIRS LEADING TO STORAGE ROOM.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Lifesaving
Issued 3 August 1999
Resolved
REPLACE EXISTING PLASTIC TRASH CANS WITH METAL ONES.
Condition: Unknown
Due 31 August 1999
Resolved 30 August 1999
Accommodation/Occupational Safety
Issued 8 July 1999
Resolved
ADD SCREWS/BOLTS TO SINKS, SHELVES ETC, IN GALLEY TO SECURE THEM TO THE DECK.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 8 July 1999
Resolved
PROVIDE AND POST PFD DONNING PLACARDS.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 8 July 1999
Resolved
LABEL ALL BREAKERS THROUGHOUT VESSEL.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 8 July 1999
Resolved
SHOW PROOF OF EPIRB REGISTRATION. VESSEL ROUTE REDUCED TO LAKES, BAYS, SOUNDS AND RIVERS UNTIL CLEARED.
Condition: Unknown
Due 15 July 1999
Resolved 13 July 1999
Accommodation/Occupational Safety
Issued 8 April 1998
Resolved
TEST AIR RECEIVER'S RELIEF VALVE.
Condition: Unknown
Due 8 May 1998
Resolved 24 February 1999
Fire Fighting
Issued 8 April 1998
Resolved
ENSURE FIRE DOOR TO THE GALLEY CLOSES WITHOUT ASSISTANCE WHEN MAGNET IS RELEASED. THIS ITEM TO BE COMPLETED NLT 15APR98 TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1998
Resolved 20 February 1999
Accommodation/Occupational Safety
Issued 8 April 1998
Resolved
INSTALL STEPS IN FOREPEAK FOR ACCESS TO THE COMPARTMENT.
Condition: Unknown
Due 8 May 1998
Resolved 20 February 1999
Construction/Loadline
Issued 8 April 1998
Resolved
REWELD ENTIRE LEFT SIDE OF STARBOARD BRIDGE WING DOOR. THIS ITEM TO BE COMPLETED NLT 22APR98 TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 April 1998
Resolved 20 February 1999
Construction/Loadline
Issued 8 April 1998
Resolved
REWELD MISSING SECTION OF DECK RAIL, 2ND DECK PORT SIDE. PASSENGER ACCESS SHALL BE RESTRICTED TO THIS AREA. THIS ITEM TO BE COMPLETED NLT 22APR98 TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 April 1998
Resolved 20 February 1999
Lifesaving
Issued 28 May 1997
Resolved
Properly label lifejacket stowage lockers.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Lifesaving
Issued 28 May 1997
Resolved
Place directional arrows on emergency exits.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 28 May 1997
Resolved
Mount fire extinguishers on bridge.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 28 May 1997
Resolved
Ensure all fire doors are operating properly.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Engineering
Issued 28 May 1997
Resolved
Install handles on emergency f/o shutoffs.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998