OAKLAND ANGLERS

OAKLAND ANGLERS is a 1968 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1986, most recently in May 2025, along with 77 deficiencies, 3 operational controls and 1 casualty investigation in 2018.

Records from 1986 to 2025. Most recent: inspection, 14 May 2025.

Built
1968
Last inspected
14 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WY2884
Flag
UNITED STATES
367004070
Maury page id
psix-45777

Inspections, by type

…with no type recorded7
Years with a record 35 calendar years (1986–2025)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.4 ft × 12.8 ft × 6.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR & H MARINA · SEATTLE WA, UNITED STATES · built 1968
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOAKLAND, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL9793MMSI 367004070 · active · compulsorily equipped · granted 13 February 2021, expires 13 February 2031
WY2884MMSI 367004070 · cancelled · compulsorily equipped · granted 10 December 2014, cancelled 11 February 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

14 May 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8135996
7 June 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7930178
6 June 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7713621
17 April 2023 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670093
2 February 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631160
20 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611562
10 May 2022 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7445500
4 March 2021 Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7145909
29 September 2020 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7074744
12 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6661448
13 November 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6579909
16 June 2018 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6448190
18 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6400194
27 March 2018 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6383334
3 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6137596
4 April 2017 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6117106
11 May 2016 Type not recorded
No type recorded · USCGC WAHOO (WPB 87345) · USCG Northwest District (CGD-NW) · Activity 5887281
3 March 2016 COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5826259
21 May 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4864229
1 June 2012 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4331029
9 February 2012 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4241663
3 March 2009 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3427505
6 June 2007 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2952356
7 March 2007 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2853724
3 May 2006 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2645872
1 March 2006 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2593403
14 July 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2431105
14 June 2005 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2376073
27 April 2005 In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2342545
15 March 2005 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2299350
11 May 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2048253
27 May 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1811226
24 April 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1769696
28 March 2003 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1752586
7 October 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1688020
2 May 2002 Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1611210
3 May 2001 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1370162
12 April 2001 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1436532
6 March 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1366223
27 March 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1047498
11 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 50266
5 August 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1110999
15 June 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 810754
6 May 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1466608
19 April 1999 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1469581
20 January 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125515
7 May 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 790664
9 March 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414950
13 February 1998 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112642
18 April 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1106186
27 March 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414769
11 March 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1427329
29 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 174690
18 April 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1422686
24 April 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 864051
15 March 1995 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1419390
30 March 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394086
8 June 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1457101
13 April 1993 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385052
17 April 1992 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1268910
10 February 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 952492
14 June 1991 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1250919
10 June 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1331800
1 April 1991 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 908911
18 April 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1233415
2 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1214288
6 March 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1201773
28 February 1989 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 889255
11 May 1988 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1038917
5 May 1988 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1351145
31 March 1987 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1331653
1 April 1986 COI Inspection · Credit Drydock
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1308289

Deficiency record · 77

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel was due for inspection no later than 04 June. The vessel is unable to carry passengers until successful completion of an annual inspection, currently scheduled on 18JUNE2024.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2025
Resolution: Vessel still has not completed annual or dry dock inspection. Vessel requested to be placed in a laid-up status.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2023 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. During inspection, floating light was inoperable. Vessel limited to daylight operations only until repaired or replaced. 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: Received confirmation that floating light repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 June 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel uses Hydrostatic Release Unit for float free arrangement. During inspection, unit was expired. Vessel limited to within 3 NM of coastline. 46 CFR 180.64
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: Received confirmation that new HRU installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 June 2023 Resolved
(Shutoff valves) If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. During inspection, there was a gap in the shielding. 46 CFR 182.455(b)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: Verified fuel shut-off shielding repaired to close gap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2023 Resolved
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means of steering. During inspection operator could not open deck port to access emergency steering. 46 CFR 182.620(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 22 June 2023
Resolution: Operator repaired. Received confirmation that emergency steering port could be opened.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has gone past 3 months from anniversary date without scheduling an annual inspection. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: Completed annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2023 Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. Vessel is overdue for 2021 fees and is in collection status. Ensure payment of fees prior to next inspection. 46 CFR 2.10-20(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: Owner provided receipt for payment.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and be installed in accordance with the manufacturer's instructions. During inspection, pre-engineered fire extinguishing system did not shut down engine. 46 CFR 181.420(a)(2) and (4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: System was repaired/inspected by third party and we verified shut downs on inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 June 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Starboard shutoff valve is missing handle. Aft shutoff valve handle has broken and is no longer connected to valve. 46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2023
Resolution: Repaired and tested by attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2023 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR 40. During inspection, operator could not provide list of employees enrolled in Company Drug and Alcohol Testing Program. 46 CFR 16.201(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 21 June 2023
Resolution: Owner provided consortium enrollment list. Spot checked DAPI program. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 June 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. 46 CFR 184.502; 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 21 June 2023
Resolution: FCC tech inspected and certified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2023 Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to— (1) Training in the use and location of firefighting equipment and general firefighting knowledge, including: (i) Location of firefighting appliances and emergency escape routes; (ii) Types and sources of ignition; (iii) Flammable materials, fire hazards and spread of fire; (iv) The need for constant vigilance; (v) Actions to be taken on board; (vi) Fire and smoke detection and automatic systems on board; and (vii) Classification of fire and applicable extinguishing agents. (2) The drills required by § 185.524, including fire location and fire type; and (3) Emergency egress training for each member of the crew, to occur for all members of the crew— (i) At least monthly while such members are employed on board the vessels; and (ii) Each time a crew member joins the crew of such vessel. (c) Training conducted on a sister vessel may be considered equivalent to the initial, monthly, and quarterly training requirements contained in paragraphs (a) and (b) of this section. (d) Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information.Date of the training;General description of the training topics. 46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2023
Resolution: Training completed and logged.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 February 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Drydock was due 30SEP2022. Complete credit drydock prior to carriage of passengers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 May 2023
Resolution: Sucessfully completed credit drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 May 2022 Resolved
Each ring life buoy on a vessel must: If on a vessel on an oceans or coastwise route, be orange in color. Vessel has a white life ring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Operator sent photo of new orange lifering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2022 Resolved
Each small battery must be located in a well ventilated space and protected from falling objects. Vessel has batteries that have exposed terminals. Cover terminals so that accidental contact between terminals cannot be made.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Opeartor sent photo of a cover installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 March 2021 Resolved
A vessel on an ocean, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals and six hand orange smoke distress signals approved in accordance with 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel doesn't have required number of flares aboard. Add required amount of flares
Action required: 10 - Deficiency Rectified
Resolved 4 March 2021
Resolution: Crewmember bought sufficient flares.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 March 2021 Resolved
Portable and semi-portable extinguishers must be inspected and maintained IAW NFPA 10, which includes routine inspection and annual servicing by an approved facility. The owner or operator must provide satisfactory evidence of the required servicing to the marine inspector. Missing service receipts. Provide records of service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 26 March 2021
Resolution: Operator provided service receipts for fire extinguishers and fire boy
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2021 Resolved
Alcohol testing. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Missing test strips. Provide test strips to vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 26 March 2021
Resolution: Operator provided pictures of newly purchased alcohol testing strips
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 March 2021 Resolved
Provision must be made for closing all supply duct cowl or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Missing dampers. Provide dampers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2021
Resolution: Operator obtained adequate dampers for protected spaces.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 16 June 2018 Resolved
Make proper repairs to main diesel engine prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2018
Resolution: Spacer fitting on high pressure oil line was loose and spraying oil, causing Low Oil Pressure alarm. Fitting tightened resolving the problem.
Engineering › Bilge Water Management System › Hose
Issued 21 May 2014 Resolved
Bilge discharge hose was cracked and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Accommodation/Occupational Safety › Ventilation › General
Issued 21 May 2014 Resolved
Bulkhead between accommodation space and machinery space needs to be vapor tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 21 May 2014 Resolved
NAV Rules was out of date and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2005 Resolved
Renew the wiring in the lazarette and machinery space compartments where there are several smaller sections of wire spliced together with solderless crimped connectors. Renew wiring to comply with 46CFR183.340.
Due 20 July 2005
Resolved 14 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2005 Resolved
Install metal supports for the cables and wiring throughout the vessel. 46 CFR 183.340(b)(4)
Due 14 July 2005
Resolved 14 July 2005
Engineering › Bilge Water Management System › Hose
Issued 14 June 2005 Resolved
Renew cracked hose at the bilge manifold that takes suction from the center compartment. 46 CFR 182.700
Due 14 July 2005
Resolved 14 July 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2005 Resolved
Provide a copy of the appropriate light list and have on board. 46 CFR 184.420
Due 14 July 2005
Resolved 14 July 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2005 Resolved
Prove proper operation of vessel's stern light and anchor light. Vessel to be limited to day time operations until this item is cleared.
Due 14 July 2005
Resolved 14 July 2005
Stability › Watertight Integrity
Issued 24 April 2003 Resolved
Correct the opening in the collision bulkhead to make it conform with 46 CFR 171.085 (h)-(j) (old S). LEGACY COMPONENT DESC: Collision Bulkhead
Due 24 May 2003
Resolved 27 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 24 April 2003 Resolved
Have all portable fire extinguishers professionally serviced (both BI's overdue 6-yr maint.; 2 BII's overdue 6-yr maint.; remaining BII needs annual service (gauge low). Must be completed prior to the carriage of passengers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 24 May 2003
Resolved 2 May 2003
Resolution: The two BI''s were re-newed; the two BII''s overdue for six-yr maint. and the one BII requiring annual servicing were taken to a fire equipment servicing facility and corrected.
Engineering › Fuel Oil Service System
Issued 24 April 2003 Resolved
Replace the main main engine fuel supply hose (between the Racor filter and the prime pump) with SAE J1942 fuel hose with appropriate fittings). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 24 May 2003
Resolved 23 May 2003
Resolution: Received copy of invoice indicating that the vessel recently purchased replacement hose that meet SAE J1942.
Documentation › Markings/Placards
Issued 24 April 2003 Resolved
Complete the installation of stern and bow hull markings (name/home port).
Condition: Improper Installation
Due 24 May 2003
Resolved 2 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 March 2003 Resolved
Tighten the hand rails around the entire length of the vessel. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 28 April 2003
Resolved 24 April 2003
Engineering › Shafting/Propeller Arrangements
Issued 28 March 2003 Resolved
Replace 4 of the 8 nuts holding the strut in place. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Strut
Condition: Unknown
Due 28 March 2003
Resolved 24 April 2003
Engineering › Steering Gear System
Issued 28 March 2003 Resolved
Replace the rudder support block with a new one. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Support Block
Condition: Improper/Lack of Maintenance
Due 28 April 2003
Resolved 24 April 2003
Stability › Watertight Integrity
Issued 2 May 2002 Resolved
Prove watertight integrity of the engine space deck hatch with a 30 PSI hose test.
Due 30 March 2003
Resolved 24 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 2 May 2002 Resolved
Renew retroreflective material on PFDs as required. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2002
Resolved 5 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 May 2002 Resolved
Renew expired iodine and eyewash kit in first aid kit
Due 5 May 2002
Resolved 5 May 2002
Engineering › Bilge Water Management System
Issued 2 May 2002 Resolved
Install a check valve in the lazarette bilge line. LEGACY COMPONENT DESC: Valve
Condition: Placed in Improper Service
Due 2 June 2002
Resolved 15 May 2002
Engineering › Fuel Oil Service System
Issued 2 May 2002 Resolved
Provide a ground across the rubber hoses on all fuel fill pipes. LEGACY COMPONENT DESC: Tank
Condition: Placed in Improper Service
Due 2 June 2002
Resolved 15 May 2002
Engineering › Fuel Oil Service System
Issued 2 May 2002 Resolved
Renew fuel shut-off valve reach rod on aft fuel tank. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 2 June 2002
Resolved 15 May 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 2 May 2002 Resolved
Provide proof of servicing of fixed gas fire extinguishing system or service system in the presence of a marine inspector.
Due 2 June 2002
Resolved 15 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 2 May 2002 Resolved
Renew fractured rail fittings: 1) at base of 7th stanchion aft on stbd side and 2) on middle course of 6th stanchion aft on port side. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 2 June 2002
Resolved 15 May 2002
Fire Fighting
Issued 6 May 1999 Resolved
PROVIDE THREE FIRE BUCKETS WITH LANYARDS.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Documentation
Issued 6 May 1999 Resolved
PROVIDE VALID FCC OPERATOR'S PERMIT.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Documentation
Issued 6 May 1999 Resolved
PROVIDE VALID DRUG TESTING COMPLIANCE INFORMATION.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 6 May 1999 Resolved
PROVIDE LIFE JACKET DONNING PLACARD FOR TYPE I LIFE JACKET.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Documentation
Issued 6 May 1999 Resolved
PROVIDE VALID OPERATOR'S LICENSE.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 6 May 1999 Resolved
PROVIDE LINE FOR RING BUOY PRIOR TO CARRYING ANY PASSENGERS.
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 March 1998 Resolved
CONDUCT UNDERWAY MAN OVERBOARD AND FIRE DRILLS WITH VESSEL CREW IN PRESENCEOF MARINE INSPECTOR.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Documentation
Issued 9 March 1998 Resolved
PROVIDE WRITTEN DRUG TESTING POLICY, CONTRACT WITH DRUG TESTING CONSORTIUM,DOCUMENTATION OF MANAGEMENT INFORMATION SYSTEM (MIS) SUBMITTAL, LETTER OF SUBSTANTIAL COMPLIANCE FOR DRUG TESTING CONSORTIUM.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998 Resolved
PROVIDE DOCUMENTATION OF EPIRB REGISTRATION WITH NOAA.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 9 March 1998 Resolved
PROVIDE CURRENT AND UPDATED CHARTS FOR OPERATIONAL AREA.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 9 March 1998 Resolved
RE-INSTALL BUOYANT APPARATUS AND MAKE AVAILABLE FOR INSPECTION, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 9 March 1998 Resolved
RE-INSTALL GPS, LORAN C & DEPTHSOUNDER AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Navigation
Issued 27 March 1997 Resolved
PROVIDE CURRENT AND UPDATED NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Accommodation/Occupational Safety
Issued 27 March 1997 Resolved
PROPERLY MARK BOTH SIDES OF THE EMERGENCY EXIT.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 27 March 1997 Resolved
PROVIDE PFD DONNING INSTRUCTIONS.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Lifesaving
Issued 27 March 1997 Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT OR EQUIVALENT.
Condition: Unknown
Due 27 March 1997
Resolved 27 March 1997
Engineering › Bilge Water Management System › Pump
Issued 15 March 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF THE BILGE PUMPS.
Condition: Unknown
Due 29 March 1995
Resolved 30 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
PROVE PROPER OPERATION OF ALL BILGE PUMPS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 29 March 1995
Resolved 30 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
REFASTEN MAIN DECK STANTION LOCATED IN STARBOARD AFT CORNER OF ENGINEROOM, OUTBOARD OF TAIL SHAFT PENETRATION.
Condition: Unknown
Due 15 April 1995
Resolved 30 March 1995
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 15 March 1995 Resolved
PROVE PROPER OPERATION OF ALL ELECTRONIC NAVIGATION EQUIPMENT, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 29 March 1995
Resolved 30 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
CONDUCT AN OPERATIONAL TEST OF THE HULL.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Documentation
Issued 1 April 1991 Resolved
CONDUCT STABILITY TEST.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 2 April 1990 Resolved
PROVE SATISFACTORY OPERATION OF STEERING SYSTEM FROM BOTH STEERING STATIONS.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Lifesaving
Issued 2 April 1990 Resolved
REPLACE LINES ON RING BUOY.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Lifesaving
Issued 2 April 1990 Resolved
REPLACE ORANGE SMOKE FLARES.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Construction/Loadline
Issued 2 April 1990 Resolved
MAKE VESSEL AVAILABLE FOR SEA TRIALS ONCE BACK IN WATER.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Engineering › Bilge Water Management System › Not Operational
Issued 2 April 1990 Resolved
PROVE SATISFACTORY OPERATION OF ENGINE, BILGE PUMP, AND EXHAUST SYSTEMS.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Construction/Loadline
Issued 28 February 1989 Resolved
PROVIDE A GASKET ON THE HATCH COVER OPENING ON THE COLLISION BULKHEAD AND MAKE WATERTIGHT.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
CONDUCT SEA TRIAL.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Electrical
Issued 28 February 1989 Resolved
PROVIDE GROUNDING WIRE TO AFT FUEL TANK IN THE LAZARETTE.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
REPAIR / REPLACE WOODEN BACKING PLATES TO THE HEAD INTAKE AND DISCHARGE THROUGH HULL FITTINGS.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Lifesaving
Issued 28 February 1989 Resolved
COMPLETE PAINTING THE BUOYANT APPARATUS STENCIL NAME AND NUMBER OF PEOPLE ON IT, REINSTALL ON VESSEL.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
PRIOR TO THE FIRST REINSPECTION, PROVIDE AN ADEQUATE NUMBER OF FREEING PORTS IN ACCORDANCE WITH 46 CFR 171.150. TOTAL AREA REQUIRED = 580 SQ.IN.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 5 May 1988 Resolved
CONDUCT SEA TRIALS TO PROVE WATERTIGHT INTEGRITY OF HULL.
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988

Casualty record · 1

13 November 2018Routine · role: Subject of Search and Rescue · activity 6579909
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TALLY HO (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.