MAURY USCG vessel records
← All vessels

RUDEE ROCKET

Built
1997
Last inspected
21 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4683
457803
Flag
UNITED STATES
Maury page id
psix-457803

Documentation record

Registered dimensions (L × B × D)64.7 ft × 18.2 ft × 6.0 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOCEAN ROCKETS INC · TUCKAHOE, NJ, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVIRGINIA BEACH, VA
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 15 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

21 April 2026 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8349912
7 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8344004
24 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8118093
7 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7908184
2 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7887110
17 April 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7666332
18 April 2022 Hull Examination · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7433290
29 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417054
20 April 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7177379
1 June 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6963357
27 May 2020 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6957068
22 April 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6667335
30 April 2018 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6400885
23 April 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6395925
14 April 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6124301
29 March 2017 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6112302
2 May 2016 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5862115
12 April 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5846857

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 April 2026 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI observed pressure gauge reading 30 PSI. 46 CFR 181.300(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: Recviced picture of new guage installed and reading 60 PSI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2025 Resolved
On a vessel of not more than 65-ft in length carrying more than 49 passengers, and on a vessel of more than 65-ft, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60psi at the pump outlet. The pressure gauge only reached 40psi. (46 CFR 181.300(a)(iii)(b))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2025
Resolved 20 June 2025
Resolution: Received objective evidence that a working gauge was installed on the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 May 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, and personnel injury. Marine Inspector observed the throttle cable from the main control station to the starboard main engine to be chaffed through the outer protective sheath and the metal core is slightly worn and rusted. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2024
Resolved 9 May 2024
Resolution: O/O replaced throttle cables in kind and performed satisfactory tests in the presence of the attending CGMI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 March 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 5 April 2022
Resolution: Vessel has acquired all nautical publications.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 March 2022 Resolved
The OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Wooden "L" brackets connecting vertical frames to ceiling joists in void number 01 and 02 are wasted. Repair at next dry dock to the satisfaction of the marine inspector. Marine inspector to verify condition of framing once "L" brackets are removed and before repair is made. 46.CFR176.840
Action required: 705 - Other - as specified
Due 31 May 2022
Resolved 28 June 2022
Resolution: Gussets repaired in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021 Resolved
Packing glands on both port and stbd tailshaft were leaking excessively.
Action required: 10 - Deficiency Rectified
Due 20 April 2021
Resolved 20 April 2021
Resolution: Operator tightened glands.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 June 2020 Resolved
Fire Safety - 46CFR182.465h Provision must be made for closing all supply duct cowls and scoops. Snaps on covering waisted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 June 2020
Resolved 1 June 2020
Resolution: Crew replaced snaps and verified coverings operated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2020 Resolved
Fire Safety- 46CFR181.300b, Fire pump must have 60 PSI at the pump outlet. Vessel has 30 PSI at pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2020
Resolved 2 June 2020
Resolution: Crew replaced impeller and installed new gage in system. Inspectors verified pressure at 60 PSI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 March 2017 Resolved
Fireboy pre-engineering extinguishing system is required to have manual actuation outside of space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2017
Resolution: Vessel owner provided Hiller Systems servicing report for engine room pre-engineered fixed fire fighting system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.