Records from 1985 to 1998. Most recent: inspection, 9 April 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
9 April 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 788994
12 November 1997
COI Inspection · Drydock Extension · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383704
20 November 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367975
4 September 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 942753
15 August 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1087198
12 June 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371432
28 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394504
11 October 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357350
11 November 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356908
14 October 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401896
9 July 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154785
12 August 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249295
17 January 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1266861
25 July 1991
COI Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937915
26 September 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 920505
27 July 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233496
8 September 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886496
12 September 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1204881
27 July 1988
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344829
10 November 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331340
5 November 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331339
29 July 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1337637
10 April 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329846
13 January 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314661
21 January 1986
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1305204
14 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977093
Documentation
Issued 28 March 1996
Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Lifesaving
Issued 28 March 1996
Resolved
Renew PFD reflective tape as needed.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Engineering
Issued 28 March 1996
Resolved
Freshen markings on remote fuel shut off.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 28 March 1996
Resolved
Provide portable lights in accordance with 46 CFR 183.420.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Navigation
Issued 28 March 1996
Resolved
Prove proper operation of the running lights.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996
Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills and training.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996
Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training and emergency drills.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996
Resolved
Provide evidence of compliance with 46 CFR, abandon ship and man overboard drills and training.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Engineering
Issued 11 November 1994
Resolved
PROVIDE AND INSTALL PROPER LAGGING FOR EXHAUST SYSTEM.
Condition: Unknown
Due 11 November 1994
Resolved 11 November 1994
Construction/Loadline
Issued 14 October 1994
Resolved
REPAIR /REPLACE TO GOOD WOOD FOURTH FRAME PORT AND STB SIDE AND INTERRIOR DECKING DUE TO TERMITE AND DRY ROT DAMMAGE.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994
Resolved
REPAIR TO GOOD WOOD, SOFT SPOTS AROUND RUDDER/SHAFT STRUT AREA._x001C_
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Engineering
Issued 14 October 1994
Resolved
MAKE ENGINE AND ALL AUXILIARY EQUIPMENT AVAILABLE FOR INSPECTION, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994
Resolved
REPAIR TO GOOD WOOD, SOFT SPOT AMIDSHIP PORT OF KEEL.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994
Resolved
REPAIR/REPLACE TO GOOD WOOD STEPS AND RAILS TO PASSENGER ENTRY WAY TO MAIN CABIN.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Navigation
Issued 14 October 1994
Resolved
REPAIR RUDDER RAM CONNECTION TO MAIN RUDDER POST, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Navigation
Issued 27 July 1990
Resolved
DOUBLE NUT OR DRILL AND PIN STEERING GEAR BASE AND RUDDER STOCK MOUNTS.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Fire Fighting
Issued 27 July 1990
Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Engineering
Issued 8 September 1989
Resolved
REPLACE PLASTIC BOWL ON RACOR FUEL OIL FILTER WITH MARINE APPROVED UNIT.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Documentation
Issued 27 July 1988
Resolved
MARK VESSEL NAME AND HOME PORT ON VESSEL.
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988
Documentation
Issued 21 January 1986
Resolved
PLACE ON BOARD THE VESSEL'S DOCUMENT.
Condition: Unknown
Due 21 January 1986
Resolved 21 January 1986
Fire Fighting
Issued 21 January 1986
Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 January 1986
Resolved 21 January 1986