MAURY USCG vessel records Sign in
← All vessels

MISS KAUAI

MISS KAUAI is a 1961 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1985, most recently in April 1998, along with 21 deficiencies.

Records from 1985 to 1998. Most recent: inspection, 9 April 1998.

Built
1961
Last inspected
9 April 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45785

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (1985–1998)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

9 April 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 788994
12 November 1997 COI Inspection · Drydock Extension · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383704
20 November 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367975
4 September 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 942753
15 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1087198
12 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371432
28 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394504
11 October 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357350
11 November 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356908
14 October 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401896
9 July 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154785
12 August 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249295
17 January 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1266861
25 July 1991 COI Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937915
26 September 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 920505
27 July 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233496
8 September 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886496
12 September 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1204881
27 July 1988 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344829
10 November 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331340
5 November 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331339
29 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1337637
10 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329846
13 January 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314661
21 January 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1305204
14 February 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977093

Deficiency record · 21

Documentation
Issued 28 March 1996 Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Lifesaving
Issued 28 March 1996 Resolved
Renew PFD reflective tape as needed.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Engineering
Issued 28 March 1996 Resolved
Freshen markings on remote fuel shut off.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Electrical
Issued 28 March 1996 Resolved
Provide portable lights in accordance with 46 CFR 183.420.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Navigation
Issued 28 March 1996 Resolved
Prove proper operation of the running lights.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills and training.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training and emergency drills.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Documentation
Issued 28 March 1996 Resolved
Provide evidence of compliance with 46 CFR, abandon ship and man overboard drills and training.
Condition: Unknown
Due 28 March 1996
Resolved 28 March 1996
Engineering
Issued 11 November 1994 Resolved
PROVIDE AND INSTALL PROPER LAGGING FOR EXHAUST SYSTEM.
Condition: Unknown
Due 11 November 1994
Resolved 11 November 1994
Construction/Loadline
Issued 14 October 1994 Resolved
REPAIR /REPLACE TO GOOD WOOD FOURTH FRAME PORT AND STB SIDE AND INTERRIOR DECKING DUE TO TERMITE AND DRY ROT DAMMAGE.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994 Resolved
REPAIR TO GOOD WOOD, SOFT SPOTS AROUND RUDDER/SHAFT STRUT AREA._x001C_
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Engineering
Issued 14 October 1994 Resolved
MAKE ENGINE AND ALL AUXILIARY EQUIPMENT AVAILABLE FOR INSPECTION, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994 Resolved
REPAIR TO GOOD WOOD, SOFT SPOT AMIDSHIP PORT OF KEEL.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 14 October 1994 Resolved
REPAIR/REPLACE TO GOOD WOOD STEPS AND RAILS TO PASSENGER ENTRY WAY TO MAIN CABIN.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Navigation
Issued 14 October 1994 Resolved
REPAIR RUDDER RAM CONNECTION TO MAIN RUDDER POST, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 October 1994
Resolved 24 October 1994
Navigation
Issued 27 July 1990 Resolved
DOUBLE NUT OR DRILL AND PIN STEERING GEAR BASE AND RUDDER STOCK MOUNTS.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Fire Fighting
Issued 27 July 1990 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Engineering
Issued 8 September 1989 Resolved
REPLACE PLASTIC BOWL ON RACOR FUEL OIL FILTER WITH MARINE APPROVED UNIT.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Documentation
Issued 27 July 1988 Resolved
MARK VESSEL NAME AND HOME PORT ON VESSEL.
Condition: Unknown
Due 27 July 1988
Resolved 27 July 1988
Documentation
Issued 21 January 1986 Resolved
PLACE ON BOARD THE VESSEL'S DOCUMENT.
Condition: Unknown
Due 21 January 1986
Resolved 21 January 1986
Fire Fighting
Issued 21 January 1986 Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 January 1986
Resolved 21 January 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.