Records from 1997 to 1998. Most recent: operational control imposed, 29 May 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 29 May 1998
Resolved
Replace fire helmet shield. (wasted)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 29 May 1998
Resolved
Repair dogs to watertight doors as needed. (wasted/frozen)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Accommodation/Occupational Safety
Issued 29 May 1998
Resolved
Renew steps on weather deck ladders as needed. (wasted)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Accommodation/Occupational Safety
Issued 29 May 1998
Resolved
Renew catwalk grating for anchor windlass on forcastle. (wasted).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 29 May 1998
Resolved
Re-install bolts for manhole cover on forward ballast tank. (missing)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Repair exhaust pipe on emergency fire pump.(leaking)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 29 May 1998
Resolved
Provide class report for rolled up deck on maindeck at stbd. gangway. (wasted)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 29 May 1998
No resolution recorded
Replace watertight door to aft fire locker. (wasted)
Condition: Unknown
Due 7 August 1998 — due date passed with no resolution recorded
Lifesaving
Issued 29 May 1998
Resolved
Provide properly charged air cylinders for firman outfits. (discharged)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Engineering
Issued 29 May 1998
Resolved
Repair Oily Water Separator (inoperative).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Repair CO2 system and service CO2 bottles (inoperative).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Electrical
Issued 29 May 1998
Resolved
Remove test panel and dead wires in workshop area.
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Electrical
Issued 29 May 1998
Resolved
Light covers for lights in workshop area (missing).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Accommodation/Occupational Safety
Issued 29 May 1998
Resolved
Excessive debris in front of engine room escape hatch (remove).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Fire Fighting
Issued 29 May 1998
Resolved
Fire nozzles thread damaged not allowing male and female connections to fully seat (re-thread).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Excessive trash under fire hose box behind galley (remove).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Electrical
Issued 29 May 1998
Resolved
Provide light covers for lights in passageways and galley (missing).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Fire Fighting
Issued 29 May 1998
Resolved
Replace wasted port side firemain sections (holed).
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Electrical
Issued 29 May 1998
Resolved
Mount or remove lights by freezer door.
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Accommodation/Occupational Safety
Issued 29 May 1998
Resolved
Weld new brackets for ladder leading into the emergency fire pump area fromforecastle. (wasted)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Provide boat plugs for both life boats. (missing)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Provide survival manual for both life boats. (missing)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Replace wingnuts on access hatches in both life boats. (wasted)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 29 May 1998
Resolved
Provide log book for lifesaving and firefighting drills and inspection. (missing)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 29 May 1998
Resolved
Provide class report for frames and numerous holes throughout #1 & #2 cargoholds. (wasted/snapped)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Engineering
Issued 29 May 1998
Resolved
Repair fuel transfer containment as needed. (holed)
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 4 August 1997
Resolved
Port side lifeboat sailing mast. (split)
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Accommodation/Occupational Safety
Issued 28 May 1997
Resolved
Portside lifeboat catwalk wooden planks are deteriorating. replace prior to 28JUN97.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Electrical
Issued 28 May 1997
Resolved
Inadequate or missing belt/fan guards on both S/S Generators and Auxiliary engine located in engine room upper level.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Fire Fighting
Issued 28 May 1997
Resolved
Emergency fire pump exhaust system leaking and lagging is missing. ILO-147
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997