Records from 1985 to 2000. Most recent: inspection, 11 August 2000.
Inspection history · 95
11 August 2000
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1053431
4 April 2000
Type not recorded
No type recorded · Activities Europe · Activity 732826
30 December 1999
Type not recorded
No type recorded · Activities Europe · Activity 1361386
30 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 34437
9 September 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 783856
2 September 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 782095
31 July 1999
Type not recorded
No type recorded · Activities Europe · Activity 17929
19 April 1999
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1413556
8 February 1999
Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1400926
4 February 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 476741
28 August 1998
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 797409
1 July 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1465953
1 May 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 791371
27 February 1998
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1372144
12 January 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 789106
31 December 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1118879
17 December 1997
Administrative
Administrative · Activities Europe · Activity 1115828
4 November 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1120124
28 October 1997
Deficiency Check · Damage Survey
Physical examination · Activities Europe · Activity 1368450
25 September 1997
Type not recorded
No type recorded · Activities Europe · Activity 8323
17 September 1997
Type not recorded
No type recorded · Activities Europe · Activity 1107646
2 September 1997
Deficiency Check
Physical examination · Activities Europe · Activity 1371976
18 July 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 405843
14 June 1997
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1111004
13 June 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 449854
16 May 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 403801
9 May 1997
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1101080
3 May 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 403443
3 May 1997
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416500
23 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1377928
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878360
16 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 32813
29 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 960944
26 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 29346
24 July 1992
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 953724
22 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 142713
18 July 1992
Examination of Repairs · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1263837
12 July 1992
Permit to Proceed
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 951881
11 July 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 111217
26 June 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 456991
16 June 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956159
24 January 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942931
23 January 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 63215
10 January 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 503091
12 September 1991
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 934613
14 June 1991
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1343783
13 June 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 539371
30 December 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 929494
7 December 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929055
3 December 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927562
3 December 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242326
20 November 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 927360
17 August 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 917479
10 August 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1212842
1 June 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 443547
6 May 1990
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 903639
25 February 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 903878
13 June 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1208593
15 September 1988
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1042867
1 September 1988
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039127
22 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032706
11 July 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 897402
1 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894539
13 June 1988
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1204423
3 February 1988
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1330274
2 February 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 497800
29 January 1988
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1324266
13 January 1988
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1330273
5 December 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312600
1 December 1987
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1334944
26 October 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1025479
3 October 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1011526
30 September 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1015086
8 August 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 467183
16 July 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020325
5 June 1987
MARPOL Annex II Examination
Physical examination · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027681
1 June 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1313768
5 May 1987
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1024797
6 February 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1012314
13 December 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009742
21 November 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 312817
2 August 1986
Credit Drydock · Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1306881
2 August 1986
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1317382
2 June 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1305926
6 May 1986
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1308650
4 April 1986
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 1304752
28 February 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 537579
16 September 1985
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1300688
26 July 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 437038
18 May 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1291044
13 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 978836
6 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 979881
5 April 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 301356
5 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982103
15 January 1985
Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 994719
Navigation
Issued 19 April 1999
Resolved
REPAIR OR REPLACE LATCH ON SPP PHONE BOX ON FOSCSLE
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
PROPERLY REPAIR WASTED STANDPIPES FOR PORT WINCH CONTROLLER.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Lifesaving
Issued 19 April 1999
Resolved
REPAIR BROKEN RING BUOY BRACKET ON AFT MAIN DECK.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
PROVIDE COVER FOR OUTLET AND PROPERLY WIRE FORWARD FLOOD LIGHT, STBD SPAR DECK.
Condition: Unknown
Due 29 May 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
REPLACE #2 AND #3 TURBOGENERATOR TURBINE TACHOMETERS.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Electrical
Issued 19 April 1999
Resolved
PROPERLY SECURE ELECTRICAL OUTLET BOX ON STANCHION WITH PORTABLE # 27, 2ND DECK AFT.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Engineering
Issued 19 April 1999
Resolved
MAKE PROPER REPAIRS TO OUTBOARD FEED WATER PIPING INSULATION.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Construction/Loadline
Issued 19 April 1999
Resolved
PROPERLY STENCIL FIRE/BILGE/BALLAST PUMP MOTOR CONTROLLERS.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
REPLACE CONTROL AIR TANK SAFETY VALVE. UNIT SHALL BE TAGGED OUT AND INLET VALVE SECURED AND TAGGED UNTIL THIS DEFICIENCY IS CLEARED.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Navigation
Issued 19 April 1999
Resolved
MAKE PROPER REPAIRS TO STEERING GEAR HYDRAULIC PUMPS IN STEERING SPACE.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Electrical
Issued 19 April 1999
Resolved
AT STANCHION WITH PORTABLE #45, REPLACE WASTED ELECTRICAL STANDPIPE.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Fire Fighting
Issued 19 April 1999
Resolved
REPAIR WASTED BRACKETS FOR SPRINKLER DRAINS ON MAIN DECK.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Fire Fighting
Issued 19 April 1999
Resolved
PROVE PROPER OPERATION OF FIRE DAMPER, DECK AFT OF REEFER FLAT.
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Fire Fighting
Issued 19 April 1999
Resolved
REPAIR OR REPLACE HANDLE ON REEFER SPACE FIRE DAMPER
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
REPAIR FRACTURED RAIL ALONG HOUSE ADJACENT TO STBD NAV LIGHT.
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
REPAIR LOOSE LADDER BASE, 2ND DECK INTERIOR STAIRWELL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
PROPERLY REPAIR ELECTRICAL STANDPIPES AT BASE OF FWD MAST.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Lifesaving
Issued 19 April 1999
Resolved
REPAIR BROKEN RING BUOYBRACKET ON FOC'S'LE.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Fire Fighting
Issued 19 April 1999
Resolved
PROVE PROPER OPERATION OF ZONE 1 SPRINKLERS.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
PROPERLY REPAIR RAILS AND STANCHIONS ALONG RAMP TO SPAR DECK AND ON SPAR DECK.
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Lifesaving
Issued 19 April 1999
Resolved
RENEW PORT DAVIT LADDER UPPER ATTACHMENT POINT.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Construction/Loadline
Issued 19 April 1999
Resolved
PROVE PORPER OPERATION OF THE STBD BILGE/BALLAST PUMP.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Construction/Loadline
Issued 19 April 1999
Resolved
PROVE PROPER OPERATION OF THE BILGE SYSTEM FOR #2A PORT ROSE BOX.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Navigation
Issued 19 April 1999
Resolved
PROVIDE ADEQUATE COMMUNICATION VIA SPP BETWEEN AFT STEERING AND THE PILOT HOUSE.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
REMOUNT PORT AND STBD LIFEBOAT WINCH CONTROLLERS.
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Fire Fighting
Issued 19 April 1999
Resolved
PROVE PROPER OPERATION OF CO2 TIME DELAY FOR #3CH.
Condition: Unknown
Due 19 April 1999
Resolved 17 June 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
REPLACE WASTED LOWER COURSE RAILS OD P/S BOAT DECKS, AFT OF DAVITS.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
REPAIR OR REPLACE WASTED STANDPIPES ON BKHD ADJACENT TO WTD#2 HINGES.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Lifesaving
Issued 19 April 1999
Resolved
PROPERLY BRACE AND BLOCKALL COMPRESSED GAS CYLINDERS AROUND THE SHIP.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
RENEW BRACKETS FOR INVERTED U SHAPED PIPING ADJACENT TO #5 CH ESCAPE TRUNK ON AFT MAIN DECK.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Fire Fighting
Issued 19 April 1999
Resolved
REPLACE MISSING CO2 HORN IN #5CH.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Lifesaving
Issued 19 April 1999
Resolved
REMOVE EXPIRED MEDICATIONS AND BRING ALL MEDS UP TO ALLOWED AMOUNTS.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Electrical
Issued 19 April 1999
Resolved
PROPERLY SECURE CABLES AND FIXTURE, ELECTRICAL JUNCTION BOX ON STANCHION ATBASE OF RAMP TO #1 CARGO HOLD.
Condition: Unknown
Due 28 May 1999
Resolved 17 June 1999
Accommodation/Occupational Safety
Issued 19 April 1999
Resolved
REPAIR OR REPLACE HANDLE FOR FIRE CONTROL ROOM VENT.
Condition: Unknown
Due 11 July 1999
Resolved 22 July 1999
Engineering
Issued 1 July 1998
Resolved
MAKE PROPER REPAIRS TO FEED WATER PIPING, STBD BOILER AT FLANGE.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
PROPERLY SECURE DUAL MARINE ELECTRICAL OUTLET IN CREW PANTRY ABOVE SINK ANDCOUNTER.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Deck/Cargo
Issued 1 July 1998
Resolved
REPLACE CHANNEL IRON CROSSBAR ON FORWARD SIDE OF PORT AND STBD TENSIONING WINCHES ON FOCSLE.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM FOR #5 CARGO HOLD STBD BILGE WELL.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Engineering
Issued 1 July 1998
Resolved
REPLACE CONTROL AIR DRYER RECIEVER. UNIT NOT TO BE USED UNTIL PROPERLY REPAIRED.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Electrical
Issued 1 July 1998
Resolved
CLEAN EMERGENCY BATTERIES AND BATTERY ROOM.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REMOUNT EMERGENCY LIGHTING FIXTURE IN STORES ACCESS TRUNK, 2ND DECK STBD AFT.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
ON CARGO HOLD WTD #9, REPLACE BROKEN STRIKE PLATE ON LOWER EDGE.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
ON CARGO HOLD WTD #1, REWIRE POWER LEADS TO DOOR MOUNTED HYDRAULIC PUMPS. NEW CABLES TO BE RUN AS PER ALL OTHER CARGO HOLD WTDS.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REPLACE FACEPLATE SCREWS AND SAFETY LATCH ON LIGHTING PANEL L100.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
REWORK MISALIGNED DOORS ON TWO WTD, 2ND DECK AFT. DOORS ACCESS LADDER TO STEERING FLAT AND LADDER TO STORES.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Construction/Loadline
Issued 1 July 1998
Resolved
REWORK DOOR FOR WTD ON 2ND DECK LEADING TO CARGO HOLD #5 ESCAPE TRUNK.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Engineering
Issued 1 July 1998
Resolved
REPLACE MISSING SCREEN AND COVER FOR #2 STBD DOUBLE BOTTOM F.O. VENT.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Deck/Cargo
Issued 1 July 1998
Resolved
REPLACE IN KIND THE WASTED PEDESTAL FOR THE ANCHOR WINDLASS CONTROL STAND ON THE FOCSLE.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Engineering
Issued 1 July 1998
Resolved
PROVIDE APPROXIMATELY 06 FEET OF MISSING INSULATION FOR SUPERHEATER PIPING BELOW BOILERS.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Engineering
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF BOILER AUTOMATION SYSTEMS FOR MIDPERIOD REINSPECTION.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF ELEVATOR INDICATOR BEACON.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Engineering
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF PURGE TIMER FUNCTION OF BOILER AUTOMATION PROCEDURES.
Condition: Unknown
Due 28 August 1998
Resolved 28 August 1998
Lifesaving
Issued 1 July 1998
Resolved
INSTALL GASKET ON ENGINE ROOM ESCAPE SCUTTLE TO 2ND DECK.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Fire Fighting
Issued 1 July 1998
Resolved
REPAIR WASTED BOX AND PROVIDE DOOR FOR FIRE STATION #3.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Lifesaving
Issued 1 July 1998
Resolved
PROPERLY SECURE HP AIR LINE ALONG BULKHEAD, BOAT DECK STBD SIDE.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REPAIR OR REPLACE BROKEN FIXTURE, STBD LIFEBOAT ILLUMINATION LAMP.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REPLACE MISSING COVER FOR LOWER PORTION OF DISHWASHER IN OFFICER PANTRY, WHERE WIRING IS VISIBLE.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Electrical
Issued 1 July 1998
Resolved
PROPERLY WIRE GARBAGE DISPOSAL IN GALLEY, AND PROVIDE SUITABLE COVER FOR EXPOSED JUNCTION BOX ADJACENT TO DISPOSAL.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Electrical
Issued 1 July 1998
Resolved
SECURE LOOSE COVER ON PANEL L12 IN CREW PANTRY.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Accommodation/Occupational Safety
Issued 1 July 1998
Resolved
REPAIR BROKEN DECK SURFACE AT ENTRANCE TO REEFER FLAT (TRIPPING HAZARD).
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Electrical
Issued 1 July 1998
Resolved
PROVIDE PROTECTIVE COVERS (BLANKS) FOR OPEN CIRCUITS IN PANEL L-13 NEAR WALK-IN REEFERS.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 1 July 1998
Resolved
PROVIDE NEW HANDLE AT FIRE STATION #9.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Accommodation/Occupational Safety
Issued 1 July 1998
Resolved
ADJUST HINGES ON ENTRANCE DOOR TO EMERGENCY GENERATOR SPACE SO DOOR OPENS OUTWARD VICE INWARD, OR ADD KICKOUT PANEL ON EXISTING DOOR. SPACE PROTECTED BY FIXED CO2 SYSTEM.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Electrical
Issued 1 July 1998
Resolved
PROVIDE PROPER PLUG FOR FLAGSTAFF LIGHT ON STERN.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Electrical
Issued 1 July 1998
Resolved
REPLACE MISSING HINGED COVERS ON ELECTRIC OUTLET NEAR PORTABLE EXTINGUISHER#41 IN CARGO HOLDS.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Fire Fighting
Issued 1 July 1998
Resolved
PROVIDE 2.5" HOSE FOR FIRE STATION #14 PRIOR TO DEPARTURE FROM THE PORT OF WILMINGTON.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Fire Fighting
Issued 1 July 1998
Resolved
REPLACE MISSING CO2 NOZZLES IN #2A LOWER CARGO HOLD.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REPAIR INOPERATIVE LIGHT IN #5 HOLD ESCAPE TRUNK.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
ON CARGO WTD BETWEEN HOLDS #1 AND #2, REPLACE 2 MISSING DOGS ON INBOARD EDGE AND PROPERLY REPAIR FRACTURE IN FRAME IN SAME AREA.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Electrical
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF PANEL LIGHTS AND SAFETY INTERLOCKS ON ALL BLOWER CONTROL BOXES.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
PROPERLY REWIRE HEAT STRIP FOR EMERGENCY FIRE PUMP ELECTRIC MOTOR.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Electrical
Issued 1 July 1998
Resolved
REPLACE MISSING GLOBE AND GUARD FOR INCANDESCANT LIGHT IN PIPE STORES, #5 CARGO HOLD STBD SIDE.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Electrical
Issued 1 July 1998
Resolved
PROPERLY SEAL OPEN JUNCTION BOX AT BASE OF RAMP TO #1 CARGO HOLD.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
REPLACE MISSING DOG AND BROKEN STRIKE PLATE ON PORT EDGE OF #1 WTD IN CARGOHOLD.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
ON CARGO HOLD WTD #10, REPLACE MISSING DOGS ON PORT EDGE AND REPLACE STRIKER PLATES AS NEEDED ALL AROUND.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Navigation
Issued 1 July 1998
Resolved
DETERMINE SOURCE OF HYDRAULIC OIL LEAK ON STEERING GEAR, PROPERLY REPAIR AND CLEAN EXCESS OIL.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Electrical
Issued 1 July 1998
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY DIESEL GENERATOR UNDER LOAD. TEMP E-GEN INSTALLED AND TESTED 4/29/98.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Accommodation/Occupational Safety
Issued 1 July 1998
Resolved
REPAIR FRACTURED RAILS ON THE SPAR DECK PORT SIDE CENTER AND STBD SIDE FORWARD.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 1 July 1998
Resolved
PROVIDE VERIFICATION OF REQUIRED TESTS OF THE FIXED CO2 SYSTEM ABOARD THE SHIP.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Accommodation/Occupational Safety
Issued 1 July 1998
Resolved
REPAIR FRACTURED RAIL AT SECOND DECK MOORING STATION, STBD SIDE FORWARD.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Lifesaving
Issued 1 July 1998
Resolved
RENEW BROKEN HINGE ON STBD LIFEBOAT CENTER PROVISION LOCKER.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Construction/Loadline
Issued 1 July 1998
Resolved
ON CARGO HOLD WTD #11, REPLACE MISSING STRIKER PLATE ON LOWER EDGE.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Electrical
Issued 1 July 1998
Resolved
REBUILD DOOR AND LOWER WATERTIGHT COVER FOR SHORETIE BOX, STBD SIDE 2ND DECK FRAME 178.
Condition: Unknown
Due 24 August 1998
Resolved 28 August 1998
Electrical
Issued 1 May 1998
Resolved
EMERGENCY GENERATOR INOPERATIVE.
Condition: Unknown
Due 1 May 1998
Resolved 12 May 1998
Engineering
Issued 27 February 1998
Resolved
PROVIDE NEW DATA PLATES FOR P/S BOILERS AS PER 46 CFR 52.01-140.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Engineering
Issued 28 October 1997
Resolved
REPLACE MISSING INTERMIDIATE SHAFT, CONDUCT A POST CASUALTY INSPECTION IN_x001C_ THE PRESENTS OF A CG INSPECTOR, TO INCLUDE BUT NOT LIMITED TO U/W BODY AND INTERNAL STRUCTURE AT AFT BALLAST TANK, SHAFT ALIGNMENT, BEARINGS AND REDUCTION GEAR
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Engineering
Issued 17 September 1997
Resolved
Provide new data plates for P/S boilers as per 46 CFR 52.01-140.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 17 September 1997
Resolved
Verify that the CO2 siren is audible in the engineroom upper port side spare parts/workshop space.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997
Resolved
Renew electrical enclosure aft of frame 164, 2nd deck, stbd side.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Electrical
Issued 17 September 1997
Resolved
Rehang loose wiring in overhead throughout 2nd deck including at frame 117.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 17 September 1997
Resolved
Correct new Fire Control Plan to reflect actual onboard configuration. Schedule a Coast Guard Marine Inspector to verify compliance.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 14 June 1997
Resolved
Install additional fire stations (hose) at all levels of the engineroom as determined by class society to ensure an adequate number of stations for safely fighting a fire.
Condition: Unknown
Due 14 June 1997
Resolved 14 June 1997
Lifesaving
Issued 9 May 1997
Resolved
Conduct full load test on lifeboat #1 to the satisfaction of a U.S. Coast Guard Marine Inspector
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Unknown
Issued 3 May 1997
Resolved
Conduct full load test on lifeboat #1 to the satisfaction of a U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 3 May 1997
Resolved
Make permanent repairs to WTD between hold #5 and enginerrom so that it works manually or weld permanently closed
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Lifesaving
Issued 3 May 1997
Resolved
Repair all items on worklist to satisfaction of attending U.S.C.G Marine Inspector, that was issued by MSO Tampa.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Lifesaving
Issued 3 May 1997
Resolved
Repair port lifeboat aft davit limit switch.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Navigation
Issued 3 May 1997
Resolved
Provide compass deviation card.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Fire Fighting
Issued 3 May 1997
Resolved
Install additional fire stations (hose) at all levels of the engineroom. _x001C_ An inadequate number of stations for safely fighting a fire presently installed.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Documentation
Issued 3 May 1997
Resolved
Provide evidence of compliance with the Chemical Testing Program IAW 46 CFRPart 16_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Lifesaving
Issued 3 May 1997
Resolved
Make permanent repairs to gunwales on P/S lifeboats and conduct a full loadtest on same in the presence of a CG Marine Inspector
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Fire Fighting
Issued 3 May 1997
Resolved
Provide legible Fire Safety Plans for vessel and submit to OCMI for approval_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Fire Fighting
Issued 3 May 1997
Resolved
Reposition CO2 hose reel in engineroom to provide protection for ships service generators and main switchboard.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Construction/Loadline
Issued 23 January 1997
Resolved
REPAIR WATERTIGHT DOORS, ESCAPE HATCHES, AND WATERTIGHT VENT COVERS IAW ITEMS #222 AND #223 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Deck/Cargo
Issued 23 January 1997
Resolved
REPAIR ANCHOR WINDLESS IAW ITEM #302 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
REPAIR/PROVE OPERATION OF FORWARD BILGE/CHAIN LOCKER PUMP.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
REPAIR FIRE STATIONS IAW ITEM #500 OF S.S. OSPREY REPAIR ITEMS. OUTFIT AND PROVE OPERATION OF ALL FIRE STATIONS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
REPAIR DENTED FIRE MAIN IN CARGO HOLD.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
REPAIR ALL DAMAGED GOOSENECK VENTS IAW ITEM #207 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
REPAIR HOLE IN BULKHEAD BENEATH EXHAUST VENT ON 02 LEVEL NEAR MIDSHIPS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
TEST ALL FIRE DAMPERS IAW ITEM #300 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
REPAIR HOLE IN BATTERY ROOM FOR RADIO. HOLE IS ON AFT BULKHEAD OUTBOARD.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
CLEAN DECK AND LOWER BULKHEADS TO ENSURE ATTENDING [name withheld] ASSESS STRUCTURAL INTEGRITY WITHIN BATTERY ROOM.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
REPAIR/TEST SPRINKLER SYSTEM.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
PROVIDE ON STATION ALL LIFE BUOYS, FIRE EXTINGUISHERS, LIFERAFTS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
CALIBRATE ALL VITAL INSTRUMENT GAUGES IN ENGINE ROOM.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
REPAIR/RENEW OILYWATER SEPERATOR.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 23 January 1997
Resolved
PROVIDE CG APPROVED FIRE PLANS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 23 January 1997
Resolved
PROVIDE PLANS APPROVED BY MSC FOR ENGINE ROOM EXPANSION/MODIFICATION.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 23 January 1997
Resolved
SUBMIT PROPOSAL TO COGNIZANT OCMI FOR EITHER 100% WELDING OF OR REPLACEMENTOF HYDRAULIC COMPONENTS ON WTD LOCATED AFT OF S/S GENERATOR.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 23 January 1997
Resolved
SUBMIT GAUGING REPORTS FOR THE FOLLOWING TANKS: #1 B PORT DEEP TANK, #1 B STBD DEEP TANK, #1 A DEEP TANK. REPORTS TO BE SUBMITTED TO CG PORT ARTHUR OCMI.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 23 January 1997
Resolved
SUBMIT ABS REPORTS COVERING CONDITION OF FOLLOWING TANKS: #4 DB PORT FEED WATER, #4 DB STBD FEED WATER, MAIN SUMP, COFFERDAM, #2 ADB PORT OTBD TREATED FRESH, #2 ADB PORT OTBD TREATED FRESH. REPORTS TO BE SUBMITTED TO CG PORT ARTHUR OCMI.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
REPAIR PORT AND STARBOARD LIFEBOAT DAVITS IAW ITEM #503 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 23 January 1997
Resolved
REPAIR PORT AND STARBOARD LIFEBOAT GUNNELS IAW ITEM #502 OF S.S. OSPREY REPAIR ITEMS.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Deck/Cargo
Issued 16 June 1992
Resolved
PROVIDE APPROVED TEST PROCEDURE FOR BECKMAN GAS ANALYZERS
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992
Resolved
REPAIR OR REPLACE SPOTLIGHT ON FLYING BRIDGE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Documentation
Issued 16 June 1992
Resolved
PROVIDE OIL TRANSFER PROCEDURES ORGANIZED IN ACCORDANCE WITH 33 CFR 155.750(A)
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 16 June 1992
Resolved
PROVIDE AND INSTALL REMOTE SOUNDING DEVICES FOR OIL WATER SEPERATOR AND BILGE AND BALLAST OILY MONITOR IN ENGINEROOM CONSOLE SPACE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 20 November 1990
Resolved
REPAIR OR REPLACE 42 INCH GATE VALVE IN WAY OF THE MAIN OVERBOARD DISCHARGE
Condition: Unknown
Due 20 November 1990
Resolved 20 November 1990
Engineering
Issued 10 August 1990
Resolved
PRIOR TO USE OF PORT ECONOMIZER BUT NO LATER THAN 21AUG90 EFFECT PERMANENT REPAIRS TO PORT ECONOMIZER.
Condition: Unknown
Due 10 August 1990
Resolved 10 August 1990
Engineering
Issued 1 July 1988
Resolved
BYPASS AND SEAL SHUT STARBOARD SECONDARY ECONOMIZER. EFFECT PERMANENT REPAIRS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 July 1988
Resolved 1 July 1988
Fire Fighting
Issued 13 June 1988
Resolved
PRIVIDE TWO COAST GUARD APPROVED FIREMAN'S SUITS.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Fire Fighting
Issued 13 June 1988
Resolved
PROVIDE ONE ADDITIONAL SELF CONTAINED BREATHING APPARATUS WITH SPARE CANNISTER OR BOTTLE.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Unknown
Issued 13 June 1988
Resolved
PERFORM FIRE DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR AFTER RECEIVING ITEMS LISTED IN ITEMS D-1 AND D-2 ISSUED THIS DATE (TWO FIREMAN'SSUITS AND ADDITIONAL SELF CONTAINED BREATHING APPARATUS).
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Lifesaving
Issued 13 June 1988
Resolved
WEIGHT TEST BOTH LIFE BOATS AND DAVITS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Engineering
Issued 13 June 1988
Resolved
SHOW PROPER OPERATION OF THE LIGHT-OFF SEQUENCE OF BOTH PROPULSION BOILERS WHILE THE BASE BURNER IS ON THE NUMBER TWO BURNER.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Construction/Loadline
Issued 13 January 1988
Resolved
MAKE PERMANENT REPAIRS TO THE STERN FLAGSTAFF MOUNTING. REMOUNT STERN ;LIGHT AND ASSOCIATED WIRING AND HAND RAILING SUPPORT.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Deck/Cargo
Issued 1 December 1987
Resolved
MAKE PERMANENT REPAIRS TO ANCHOR WINDLASS MOTOR. INSTALL ANCHOR WINDLASS MOTOR AND INSURE PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Construction/Loadline
Issued 30 September 1987
Resolved
MAKE PERMANENT REPAIRS TO NUMBER 9 WATERTIGHT DOOR.
Condition: Unknown
Due 30 September 1987
Resolved 30 September 1987
Deck/Cargo
Issued 5 May 1987
Resolved
MAKE PERMANENT REPAIRS TO THE NO.3 STARBOARD AFT OUTRIGGER LIFTING SUPPORT ARM. MAKE TEMPORARY REPAIRS PRIOR TO DEPARTING SAN JUAN HARBOR.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
TEST RUN AND CHECK ALARMS EMERGENCY GENERATOR.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
S/S GENERATORS WILL NOT PARALLEL. CORRECT PROBLEM
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Engineering
Issued 5 May 1987
Resolved
POP TEST ALL BOILER SAFETY VALVES
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Engineering
Issued 5 May 1987
Resolved
BOILER ALARM PANEL-ATOM STEAM LOW PRESSURE ALARM-SOUNDS, BUT NO LIGHT.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Lifesaving
Issued 5 May 1987
Resolved
HOLD BOAT DRILL.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Lifesaving
Issued 5 May 1987
Resolved
WEIGHT TEST BOTH LIFE BOATS.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Electrical
Issued 5 May 1987
Resolved
ADJUST #2 S/S GENERATOR OVERSPEED TRIP. (ADJUSTMENT TOO HIGH AT PRESENT TIME-17 & 1/2 PERCENT) LOWER TO NMT 15 PERCENT.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Unknown
Issued 5 May 1987
Resolved
ENSURE PROPER OPERATION OF CO2 ALRMS.
Condition: Unknown
Due 5 May 1987
Resolved 5 May 1987
Engineering
Issued 6 May 1985
Resolved
OPEN MOUNTINGS ON PORT AND STBD BOILERS FOR INSPECTION.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Engineering
Issued 6 May 1985
Resolved
CONDUCT FIRE AND WATERSIDE EXAM OF PORT AND STBD BOILERS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Engineering
Issued 6 May 1985
Resolved
HYDROSTATICALLY TEST PORT AND STBD BOILERS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Engineering
Issued 6 May 1985
Resolved
SET AND SEAL SAFETY VALVES ON PORT AND STBD BOILERS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Navigation
Issued 5 April 1985
Resolved
USCG LIGHT LIST NOT UPDATED UC COAST PILOT NOT UPDATED
Condition: Unknown
Due 28 February 1986
Resolved 5 April 1985
Documentation
Issued 5 April 1985
Resolved
OIL RECORD BOOK NOT AVAILABLE
Condition: Unknown
Due 28 February 1986
Resolved 5 April 1985